首页 | 本学科首页   官方微博 | 高级检索  
     

倾角及冷却工况对多通路并联回路板式脉动热管传热性能的影响
引用本文:史维秀,潘利生,李惟毅. 倾角及冷却工况对多通路并联回路板式脉动热管传热性能的影响[J]. 化工学报, 2014, 65(2): 532-537. DOI: 10.3969/j.issn.0438-1157.2014.02.023
作者姓名:史维秀  潘利生  李惟毅
作者单位:1.北京建筑大学环境与能源工程学院, 北京 100044;2.北京建筑大学供热供燃气通风及空调工程北京市重点实验室, 北京 100044;3.中国科学院力学研究所, 高温气体动力学国家重点实验室, 北京 100190;4.天津大学机械工程学院, 天津 300072
基金项目:供热供燃气通风及空调工程北京市重点实验室研究基金项目(NR2013K07);2013年热能动力工程专业建设项目(04720413003);北京建筑大学科学研究基金项目。
摘    要:针对多通路并联回路板式脉动热管建立实验台,采用铜质模块加热和水浴冷却方式作为热工条件,着重考察脉动热管在不同倾角(90°,75°,60°)及冷却工况(4.5 g·s-1和9.0 g·s-1)下的传热性能,通过壁面温度的振荡和传热热阻来评价其传热效果。实验结果表明,重力对多通路并联回路板式脉动热管传热性能的影响较大,随着倾角的减少,工质的回流变弱,传热热阻变大,传热极限变低;脉动热管的加热功率与冷却能力是相互匹配的,匹配度越高,脉动热管越不易干烧,传热极限越高,在有倾角的工况下提高传热极限表现得更为明显;脉动热管运行时存在一个最佳水流量,在最佳冷却工况下,脉动热管的运行热阻最低。

关 键 词:多通路并联回路  板式脉动热管  倾角  冷却工况  传热性能  
收稿时间:2013-04-22
修稿时间:2013-08-05

Influences of inclination and cooling condition on heat transfer performance of closed loop plate pulsating heat pipe with parallel channels
SHI Weixiu,PAN Lisheng,LI Weiyi. Influences of inclination and cooling condition on heat transfer performance of closed loop plate pulsating heat pipe with parallel channels[J]. Journal of Chemical Industry and Engineering(China), 2014, 65(2): 532-537. DOI: 10.3969/j.issn.0438-1157.2014.02.023
Authors:SHI Weixiu  PAN Lisheng  LI Weiyi
Affiliation:1.School of Environment and Energy Engineering, Beijing University of Civil Engineering and Architecture, Beijing 100044, China;2.Beijing Key Laboratory of Heating, Gas Supply, Ventilating and Air Conditioning Engineering, Beijing 100044, China;3.State Key Laboratory of High-temperature Gas Dynamics, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190, China;4.School of Mechanical Engineering, Tianjin University, Tianjin 300072, China
Abstract:An experimental setup was established based on a closed loop plate pulsating heat pipe with parallel channels and a series of experiments were conducted to study its operational performance with acetone and ethanol. Heating copper block and cold water bath were adopted as thermal conditions in the experiments. The characteristics were investigated for different inclinations (90°, 75°, and 60°) and cooling conditions (4.5 and 9.0 g·s-1). The heat-transfer performance of the pulsating heat pipe was mainly evaluated by thermal resistance and wall temperature. The results show that gravity has great influence on the heat transfer. At smaller inclination, thermal resistance is larger and heat transfer limit is lower. Heating power and cooling capacity need to be matched each other, and heat transfer limit will be higher with higher matching degree, especially with inclination. There is a best mass flow rate during the operation, and the thermal resistance is the lowest under the best cooling condition.
Keywords:closed loop with parallel channels  plate pulsating heat pipe  inclination  cooling condition  heat transfer performance
本文献已被 CNKI 等数据库收录!
点击此处可从《化工学报》浏览原始摘要信息
点击此处可从《化工学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏