混凝土空间框剪结构的抗震试验与分析
引用本文:吴波,黄仕香,赵新宇. 混凝土空间框剪结构的抗震试验与分析[J]. 土木建筑与环境工程, 2011, 33(6): 44-50
作者姓名:吴波  黄仕香  赵新宇
作者单位:华南理工大学 亚热带建筑科学国家重点实验室,广州 510641;华南理工大学 亚热带建筑科学国家重点实验室,广州 510641;重庆大学 土木工程学院,重庆 400044;华南理工大学 亚热带建筑科学国家重点实验室,广州 510641;重庆大学 土木工程学院,重庆 400044
基金项目:国家自然科学基金资助项目(90815012、51025829);亚热带建筑科学国家重点实验室重点研究项目(2009ZA04);全国博士生国内访学项目(F-0920)
摘    要:开展了3个混凝土单层空间框剪结构模型的拟静力试验,考察了它们在楼板参与作用下的破坏过程,并与弹塑性分析结果进行了对比,探讨了楼板对抗侧力构件剪力分配的影响.试验和分析结果表明:1)框架梁总体上破坏较晚且破坏程度明显小于剪力墙和框架柱;2)水平荷载作用下剪力墙附近楼板损伤较大,该处楼板钢筋承受较大拉应力;3)考虑实际楼板...

关 键 词:钢筋混凝土  框剪结构  抗震试验  弹塑性分析

Seismic Tests and Pushover Analysis of Spatial RC Frame-Shear Wall Structures
WU Bo,HUANG Shi xiang and ZHAO Xin yu. Seismic Tests and Pushover Analysis of Spatial RC Frame-Shear Wall Structures[J]. Journal of Civil,Architectrual & Environment Engineering, 2011, 33(6): 44-50
Authors:WU Bo  HUANG Shi xiang  ZHAO Xin yu
Affiliation:State Key Laboratory of Subtropical Building Science, South China University of Technology, Guangzhou 510641, P. R. China;State Key Laboratory of Subtropical Building Science, South China University of Technology, Guangzhou 510641, P. R. China;College of Civil Engineering, Chongqing University, Chongqing 400044, P. R .China;State Key Laboratory of Subtropical Building Science, South China University of Technology, Guangzhou 510641, P. R. China;College of Civil Engineering, Chongqing University, Chongqing 400044, P. R .China
Abstract:Pseudo-static tests of three one-storey spatial RC frame-shear wall structures with floor slabs were conducted to investigate their failure modes and hysteretic behaviors. The test results were compared with those of pushover analysis. It is shown that: 1) damage of the frame beams occurs later and is less than that of the shear wall and the frame columns; 2) damage of the floor slabs under lateral loading is significant in regions close to the shear wall, and tensile stresses of slabs' steel bars in these regions are much larger; 3) in comparison with the case that the floor slabs are neglected, the maximum lateral load that a frame-shear wall structure can bear is larger in the case that the floor slabs are taken into account, and the contribution ratio of the shear wall also increases; 4) shear forces carried by the frame columns with identical cross sections and reinforcement details but located at different positions are close to each other on the whole.
Keywords:reinforced concrete   frame-shear wall structure   seismic test   elastoplastic analysis