Produktschonende Betriebs‐ und Designparameter von Wärmeübertragern für temperaturempfindliche Prozessströme
Authors:Moritz Dippel  Marcus Grünewald
Affiliation:1. Ruhr‐Universit?t Bochum, Lehrstuhl für Fluidverfahrenstechnik, Universit?tsstra?e 150, 44801 Bochum, Deutschland.Ruhr‐Universit?t Bochum, Lehrstuhl für Fluidverfahrenstechnik, Universit?tsstra?e 150, 44801 Bochum, Deutschland.;2. Ruhr‐Universit?t Bochum, Lehrstuhl für Fluidverfahrenstechnik, Universit?tsstra?e 150, 44801 Bochum, Deutschland.
Abstract:To allow the calculation of product degradation rates as extension to the currently used thermotechnical design calculations for heat exchangers, a volume‐related, reaction‐kinetic approach was developed. Therefore, a model system was selected and the product protection design parameters were determined for a lab‐scale heat exchanger with the help of simulations. The validation was demonstrated in an experiment. Additionally, the product‐protecting operating parameters for the heat exchanger were calculated with a technically relevant set of compounds.
Keywords:CFD‐Simulation  Produktschä  digung  Produktschonung    rmeü  bergang    rmeü  bertrager  CFD Simulation  Heat exchange  Heat exchanger  Product degradation  Product protection