首页 | 本学科首页   官方微博 | 高级检索  
     

某核电厂蒸汽发生器水室内松脱事件诊断
引用本文:胡建荣,刘才学,罗婷,简捷,杨泰波,李翔. 某核电厂蒸汽发生器水室内松脱事件诊断[J]. 核动力工程, 2021, 42(4): 254-258. DOI: 10.13832/j.jnpe.2021.04.0254
作者姓名:胡建荣  刘才学  罗婷  简捷  杨泰波  李翔
作者单位:中国核动力研究设计院,成都,610213
摘    要:某核电厂在热态性能试验(简称热试)期间出现蒸汽发生器松脱部件报警事件,为探究松脱部件报警原因以及评估设备损害程度,需对松脱部件进行及时确认。通过建立松脱部件诊断分析模型,对松脱事件发生时的原始数据进行详细分析,估计了松脱信号的传播速度、松脱部件质量和能量,最后评估了此次松脱报警事件的危害性。结果表明,蒸汽发生器内存在的松脱部件为游动的金属部件,该部件是反应堆内部结构脱落部件,其撞击频率为8700~9300 Hz,碰撞加速度峰值范围为3g~90g,松脱信号传播群速度为3200~3300 m/s,估计松脱部件质量约0.1 kg,撞击能量为0.45~0.89 J;质量和能量诊断结果与实际符合较好,表明本文提出的质量和能量估计方法是有效的。 

关 键 词:蒸汽发生器  松脱事件  诊断  松脱定位  质量估计
收稿时间:2020-07-06

Diagnostic of Loose Parts Event in Water Chamber of Steam Generator
Affiliation:Nuclear Power Institute of China, Chengdu, 610213, China
Abstract:During the hot performance test in a nuclear power plant, the alarm event of the loose parts of the steam generator occurred. In order to explore the alarm cause for the loose parts and evaluate the damage of the equipment, it is necessary to confirm the loose parts in time. By establishing the diagnosis and analysis model of the loose parts, the original data of the loose event is analyzed in detail, and the propagation speed of the loose signal, the quality and energy of the loose parts are estimated. Finally, the harmfulness of the loose alarm event is evaluated. The results show that the loose part in the steam generator is a moving metal part, which is a loose part of the internal structure of the reactor. The impact frequency of the loose part is 8700~9300 Hz, the peak range of impact acceleration is 3g~90g, the propagation group velocity of the loose signal is 3200~3300 m/s, and the mass of the loose part is estimated to be about 0.1 kg. The impact energy is 0.45~0.89 J. The diagnostic results of mass and energy are in good agreement with the actual situation, which shows that the proposed method is effective. 
Keywords:
本文献已被 万方数据 等数据库收录!
点击此处可从《核动力工程》浏览原始摘要信息
点击此处可从《核动力工程》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏