摘    要:提出一种能够应用于铁磁性与非铁磁性材料缺陷检测的弱磁检测技术,并以多晶硅和7A09铝合金两种非铁磁性材料为例,阐述了该技术检测非铁磁性材料的一般过程,即测试材料磁导率、设计实验、采集信号及信号分析。多晶硅自然缺陷检测实验表明,弱磁检测技术能够检测直径为10 μm的夹杂缺陷;铝合金人工缺陷检测实验表明,对于Φ0.4 mm的孔型缺陷和深度为1~2 mm的槽型缺陷,弱磁检测技术都具有很好的检测效果;验证了这种检测方法在非铁磁性材料检测中的可行性。

关 键 词:弱磁检测  磁导率  多晶硅  7A09铝合金
收稿时间:2015-11-08
修稿时间:2016-01-07

Research on the Application of Weak Magnetic Technology in the Detection of Non-ferromagnetic Materials
LIAO Jun, XIA Gui-suo, LI Lang, ZOU Heng-cai, HU Bo, CHENG Qiang-qiang. Research on the Application of Weak Magnetic Technology in the Detection of Non-ferromagnetic Materials[J]. Failure Analysis and Prevention, 2016, 11(1): 13-16. DOI: 10.3969/j.issn.1673-6214.2016.01.003
Authors:LIAO Jun  XIA Gui-suo  LI Lang  ZOU Heng-cai  HU Bo  CHENG Qiang-qiang
Affiliation:1.1. Key Laboratory of Nondestructive Testing (Ministry of Education), Nanchang Hangkong University, Nanchang 330063, China
Abstract:Magnetic detection technology had generally used in the defect detection of ferromagnetic materials. In current study, a kind of weak magnetic detection technology which can be applied to the defect detection of ferromagnetic and non-ferromagnetic materials is presented. The basic principle of the technology of weak magnetic detection is introduced. Taking two kinds of non-ferromagnetic materials, polysilicon and 7A09 aluminum alloy as an example, in this paper, the general process of detecting non ferromagnetic materials by using weak magnetic detection technology has been described. Having tested material permeability, designed experiment, collected and analyzed signals. The experiments on natural defect detection of polysilicon shows that the weak magnetic detection technology can detect the inclusion defects of 10 μm diameter, and the experiments of artificial defect detection of aluminum alloy shows that the weak magnetic detection technology has a good detection effect onφ0. 4mm hole defect and groove type defect in 1 mm to 2 mm depth. The feasibility of this method in the detection of non ferromagnetic materials has been verified.
Keywords:weak magnetic detection  permeability  polysilicon  7A09 aluminum alloy