首页 | 本学科首页   官方微博 | 高级检索  
     


High‐temperature‐resistant polymer gel system with metal–organic mixed cross‐linking agents
Authors:Xiaoyun Zhang  Sisi Zhang  Liang Li  Ruonan Wu  Dongming Liu  Jihui Wu  Wei Wu
Affiliation:1. College of Science, China University of Petroleum (East China), Qingdao, China;2. Department of Petroleum Engineering, Texas Tech University, Lubbock, Texas;3. Binnan oil production plant, Shengli Oil Field, Sinopec, Shandong, China
Abstract:A high‐temperature (200°C)‐resistant polymer gel system was developed from partially hydrolyzed polyacrylamide (HPAM), chromium lactate (CrL), and water‐soluble phenol/formaldehyde resin (WPF) mixed cross‐linkers. Rheological measurements indicated that the gelation process of the gel system could be divided into four successive steps: induction, first cross‐linking with metal cross‐linker, secondary cross‐linking with organic cross‐linker, and stabilization. Effects of various parameters that affect the gelation time and gel strength including polymer concentration, cross‐linker concentration, salinity, pH, and the gelation temperature were evaluated. Gelant formulated with 0.5 wt % HPAM, 0.1 wt % CrL, and 0.9 wt % WPF and treated at 80°C for 48 h showed sufficient gelation time, high rigidity, and good thermal stability. Morphology observation by scanning electron microscopy (SEM) and atomic force microscopy (AFM) revealed that the gel had compact network microstructure. A cross‐linking mechanism for the gel system was proposed based on the gelation process and experimental results. © 2015 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2015 , 132, 42261.
Keywords:cross‐linking  gels  oil and gas
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号