摘    要:控制棒导向筒开口销是核电厂堆内构件的关键连接部件,长期运行后应力腐蚀裂纹是影响开口销质量的重要隐患。为实现控制棒导向筒开口销的高效精确检查,设计了一种多晶片集成的插片状超声探头,并搭建了一套适用于水下自动无损检测的系统,并进行了系统测试和验证,结果表明开口销检测系统具有较高检测效率和任务适应性,为现场的应用检查提供了基础。

关 键 词:超声检测  堆内构件  控制棒导向筒开口销

Development of Ultrasonic Inspection System for Control Rod Guide Split Pins in Nuclear Power Plants
Ma Guanbing,Ding Hui,Wang Weiqiang,Yan Jingli,Ma Chao,Wang Bin. Development of Ultrasonic Inspection System for Control Rod Guide Split Pins in Nuclear Power Plants[J]. Nuclear Power Engineering, 2021, 42(2): 144-147. DOI: 10.13832/j.jnpe.2021.02.0144
Authors:Ma Guanbing  Ding Hui  Wang Weiqiang  Yan Jingli  Ma Chao  Wang Bin
Affiliation:(School of Materials Science and Engineering,Southeast University,Nanjing,211189,China;CGN Inspection Technology Co.,Ltd.,Suzhou,Jiangsu,215026,China)
Abstract:The control rod guide split pin is a key connecting part of the nuclear power plant reactor internals. Stress corrosion cracking is an important potential danger that affects the quality of the split pin after long-term operation. In order to achieve an efficient and accurate inspection of the control rod guide split pin, a multi-chip integrated card-shaped ultrasonic probe is designed in this paper, and a system suitable for automatic underwater non-destructive testing is established. The results show that the split pin inspection system is with high detection efficiency and task adaptability, which provides a basis for field application inspection.
Keywords:Ultrasonic testing  Reactor internals  Control rod guide split pin