首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This study reported the efficiency of a free water surface flow constructed wetland (CW) system that receives runoff impacted stream water from a forested and agricultural watershed. Investigations were conducted to examine the potential effect of hydraulic fluctuations on the CW as a result of storm events and the changes in water quality along the flow path of the CW. Based on the results, the incoming pollutant concentrations were increased during storm events and greater at the near end of the storm than at the initial time of storm. A similar trend was observed to the concentrations exiting the CW due to the wetland being a relatively small percentage of the watershed (<0.1%) that allowed delays in runoff time during storm events. The concentrations of most pollutants were significantly reduced (p < 0.05) except for nitrate (p = 0.5). Overall, this study suggests that the design of the system could feasibly function for the retention of most pollutants during storm events as the actual water quality of the outflow was significantly better by 21-71% than the inflow and the levels of pollutants were reduced to appreciable levels.  相似文献   

2.
The study was constructed to monitor representative inflow and outflow from infiltration and non-infiltration type best management practice (BMP) sites developed at a university campus, allowing the determination of overall performance efficiency in terms of runoff reduction and pollutant removal. Based on the monitored storm events, the runoff and discharged volume and flow rates exhibited high positive correlations with total rainfall depth (p<0.001). Findings revealed that as the total rainfall increases, the amount of volume reduction and pollutant removal decreases for both types of BMP. Infiltration BMP showed a higher ability in treatment performance especially during small storm events than non-infiltration type; however, the differences were not significant. Pollutant removal rates of infiltration type were in the range of 70-90% while between 35 and 80% for the non-infiltration type for storm events with less than 10 mm rainfall depth. Average volume reductions were 71 ± 33% and 32 ± 32% for the infiltration and non-infiltration type, respectively. The ratio of the discharge volume was significantly greater than the ratio of discharge pollutant load indicating a high potential for water quality improvement. Design recommendations were provided considering sizing and cost for on-site application of similar BMP designs in the future.  相似文献   

3.
This research was conducted to investigate the phosphorus forms present in water, soil and sediment and to estimate the phosphorus mass balance in a surface flow constructed wetland (CW). Water quality and sediment samples were collected from each cell along the hydrologic path in the CW from October 2008 to December 2010. At the same time, three dominant plant species (e.g. common reed and cattails) were observed through the measurement of the weight, height and phosphorus content. Based on the results, the orthophosphate constituted 24-34% of total phosphorus in water for each cell. The overall average phosphorus removal efficiency of the CW was approximately 38%. The average inflow and outflow phosphorus loads during the monitoring period were 1,167 kg/yr and 408 kg/yr, respectively. The average phosphorus retention rate was 65%, was mainly contributed by the settling of TP into the bottom sediments (30%). The phosphorus uptake of plants was less than 1%. The estimated phosphorus mass balance was effective in predicting the phosphorus retention and release in the CW treating wastewater. Continuous monitoring is underway to support further assessment of the CW system and design.  相似文献   

4.
Data from 18 sampling wells in Kodij?rve horizontal subsurface flow (HSSF) constructed wetland (CW) (South Estonia) is presented and differences in purification efficiencies inside the HSSF CW are calculated. Temporarily anaerobic conditions in the Kodij?rve HSSF system did not allow efficient removal of BOD7, NH4-N, Ntot and Ptot. In 2002 a vertical subsurface flow filter was constructed to enhance aeration. The design of the system was based simply on the oxygen demand of the wastewater and on the aeration potential of vertical flow wetlands. The vertical flow system has shown satisfactory results. The purification efficiency of BOD7 in the Kodij?rve CW has improved significantly and there has been a slight increase in purification efficiencies of NH4-N and Ntot. On the ohther hand, the removal efficiency of Ptot has decreased significantly. Although, the mass loading rates have increased, mass removal rates of all four parameters have improved significantly. Nevertheless, optimization of the constructed wetland system is essential in order to meet effluent standards during wintertime.  相似文献   

5.
Vegetated drainage ditches (VDD) as a type of constructed wetland primarily serve to remove and store excess water associated with irrigation and storm events. Current research suggests using a VDD as an additional practice in the mitigation of surface water pollution. The VDD for water treatment of the Glinscica River was constructed in 2006. The efficiency of the system was evaluated in 2008 and 2009 regarding the reduction of SS, COD, BOD5, NH4-N, NO3-N, NO2-N, TN, ON and TP. The microbiological association developed in the VDD was analyzed with a focus on the identification and quantification of the narG gene as a denitrification indicator. This paper discusses the efficiency of pollution removal and the distribution of the narG gene within the VDD. The results showed that the highly fluctuating water regime was the main reason for the even distribution and abundance of the narG gene throughout the system, regardless of oxygen saturation or the nutrient status of the wastewater. With the exception of SS, pollutant concentrations met the permitted outflow levels.  相似文献   

6.
By using a two-stage constructed wetland (CW) system operated with an organic load of 40 gCOD.m(-2).d(-1) (2 m2 per person equivalent) average nitrogen removal efficiencies of about 50% and average nitrogen elimination rates of 980 g N.m(-2).yr(-1) could be achieved. Two vertical flow beds with intermittent loading have been operated in series. The first stage uses sand with a grain size of 2-3.2 mm for the main layer and has a drainage layer that is impounded; the second stage sand with a grain size of 0.06-4 mm and a drainage layer with free drainage. The high nitrogen removal can be achieved without recirculation thus it is possible to operate the two-stage CW system without energy input. The paper shows performance data for the two-stage CW system regarding removal of organic matter and nitrogen for the two year operating period of the system. Additionally, its efficiency is compared with the efficiency of a single-stage vertical flow CW system designed and operated according to the Austrian design standards with 4 m2 per person equivalent. The comparison shows that a higher effluent quality could be reached with the two-stage system although the two-stage CW system is operated with the double organic load or half the specific surface area requirement, respectively. Another advantage is that the specific investment costs of the two-stage CW system amount to 1,200 EUR per person (without mechanical pre-treatment) and are only about 60% of the specific investment costs of the singe-stage CW system.  相似文献   

7.
唐双成  罗纨  贾忠华  李山  仵艳 《水利学报》2015,46(8):943-950
雨水花园作为一种生物滞留系统,能够有效降低城市化进程对城市水文和水质带来的负面影响,但其效果与雨水径流中污染物的赋存形态以及花园内部的水力特性等因素有关。通过一项在黄土地区开展的雨水花园对路面雨水径流水文过程及污染物降解的试验研究,分析了雨水花园对不同赋存形态氮磷污染物的去除效果;同时根据雨水花园入流和出流的水文过程监测数据,分析了土壤优先流的存在及其对污染物去除效果的影响。结果显示,雨水花园入流中颗粒态磷和溶解态磷的浓度比例约为4∶1,颗粒态氮和溶解态氮的浓度比例接近1∶1;颗粒态总磷的浓度去除率和负荷去除率分别为40.1%和69.9%,颗粒态总氮的浓度去除率和负荷去除率分别为44.8%和73.8%;系统对于溶解态的氮、磷几乎没有去除能力。雨水花园土壤中存在的优先流现象导致出流速度较快,雨水径流在花园内的水力停留时间较短,结果表明:系统能够拦截颗粒态污染物,但对溶解态污染物去除效果较差;雨水花园对入流中总磷和总氮的浓度去除率很低,平均值仅为6.3%和-2.7%,但因截留了很大比例的入流(平均为51.5%),其对氮、磷污染物总负荷的削减分别达到52.5%和51.5%。所以,利用城市雨水花园来滞留雨水径流,净化雨水水质在研究区具有良好的应用前景。  相似文献   

8.
A new type of hybrid constructed wetland (CW), consisting of both vertical-baffled flow wetland (VBFW) and horizontal subsurface flow wetland (HSFW), has been deployed in Southern China to naturally accelerate the removal of organic matter and nitrogen. The hybrid CW system is characterised by a combination of continuous baffled flow vertical wetland and 'S' pattern horizontal subsurface flow wetland with natural aeration ditches to increase the concentration of dissolved oxygen in the HSFW bed. An internal circulatory system from the HSFW effluent back to the VBFW may optionally be operated to enhance the biological denitrification effect. Cyperus alternifolius is the main macrophyte in the wetland bed. The performance of the hybrid CW was studied with a pilot-scale system and three full-scale systems for municipal sewage treatment in Southern China. The results suggest that this new hybrid CW can achieve removal efficiencies of chemical oxygen demand, suspended solids, ammonia nitrogen, total nitrogen, and total phosphorus of better than 83.6, 95.0, 71.7, 64.5 and 68.1% respectively, with a specific wetland bed area of 0.70-0.93 m(2) PE(-1). The mean effluent concentrations of these parameters would meet the regulatory discharge limits for wastewater treatment systems (GB18918, 2002) and reuse in the context of agricultural irrigation solutions in China.  相似文献   

9.
The paper presents the detailed design and some preliminary results obtained from a study regarding a wastewater treatment pilot plant (WWTPP), serving as a multistage constructed wetland (CW) located at the rural settlement of 'Chorfech 24' (Tunisia). The WWTPP implemented at Chorfech 24 is mainly designed as a demonstration of sustainable water management solutions (low-cost wastewater treatment), in order to prove the efficiency of these solutions working under real Tunisian conditions and ultimately allow the further spreading of the demonstrated techniques. The pilot activity also aims to help gain experience with the implemented techniques and to improve them when necessary to be recommended for wide application in rural settlements in Tunisia and similar situations worldwide. The selected WWTPP at Chorfech 24 (rural settlement of 50 houses counting 350 inhabitants) consists of one Imhoff tank for pre-treatment, and three stages in series: as first stage a horizontal subsurface flow CW system, as second stage a subsurface vertical flow CW system, and a third horizontal flow CW. The sludge of the Imhoff tank is treated in a sludge composting bed. The performances of the different components as well as the whole treatment system were presented based on 3 months monitoring. The results shown in this paper are related to carbon, nitrogen and phosphorus removal as well as to reduction of micro-organisms. The mean overall removal rates of the Chorfech WWTPP during the monitored period have been, respectively, equal to 97% for total suspended solids and biochemical oxygen demand (BOD5), 95% for chemical oxygen demand, 71% for total nitrogen and 82% for P-PO4. The removal of E. coli by the whole system is 2.5 log units.  相似文献   

10.
This study examined a novel reuse of alum sludge, an inescapable by-product of drinking water treatment process when aluminium salt is added as a coagulant, as the main medium in a laboratory-scale multi-stage constructed wetland (CW) system for reject water treatment. Such reject water is a main concern in municipal wastewater treatment plant (MWWTP) for increasing the organic and nutrient loading. A 'tidal flow' strategy was employed to enhance the wetland aeration to stimulate organic matters (OM) and ammoniacal-nitrogen (N) oxidation while the 'step feed' operation was adopted to supply the necessary amount of carbon source for denitrification. The results reveal that alum sludge acting as P adsorbent can secure the P removal. Meanwhile, high removals of N and OM can also be obtained due to the active bacteria growth on the alum sludge surface. The results show that average removal efficiencies of 65.4 +/- 12.3% for chemical oxygen demand (COD), 67.8 +/- 9.2% for five-day biochemical oxygen demand (BOD5), 33.6 +/- 17.0% for N and 99.5 +/- 0.49% for P can be achieved over a period of 190 days. This indicates that novel reuse of alum sludge as medium in CW system can provide a promising approach for reject water treatment. Therefore, it will significantly reduce the amount of pollutant feedback through reject water recycling in a MWWTP.  相似文献   

11.
The performance of a constructed wetland (CW) and wastewater stabilisation pond (WSP) system for sewage reclamation and paddy rice irrigation in a decentralised rural area was examined using a feasibility study. The CW was satisfactory for sewage treatment, with good removal efficiency even in the winter period, but the effluent concentration was relatively high in the winter period owing to the high influent concentration. The CW effluent was further treated in a WSP and the WSP effluent was considered safe for crop irrigation with respect to sewage-borne pathogens. Reclaimed water irrigation did not adversely affect the yield of rice; on the contrary, it resulted in an approximately 50% greater yield than in controls. The chemical characteristics of the soil did not change significantly during the experimental period of irrigation with reclaimed water. In the winter, CW effluent could be stored and treated in a WSP until the spring; the water could then be discharged or reused for supplemental irrigation during the typical Korean spring drought. Overall, sewage treatment and agronomic reuse using a CW-WSP system could be a practical integrated sewage management measure for protecting receiving water bodies and overcoming water shortages in decentralised rural areas.  相似文献   

12.
北方某人工湿地净化能力分析   总被引:1,自引:1,他引:0  
在对北方某人工湿地长期观测取得的大量详尽数据的基础上,分析了人工湿地系统总体净化能力和潜流人工湿地水质动态变化特征。结果表明:该人工湿地示范工程对水质净化效果较为明显,对各类污染物的去除率平均可达40%;潜流人工湿地可对污水进行深度处理,对BOD5、NH4-N的去除效果最好,去除率为80%~90%,对NO3-N、TN的去除效果较好,去除率为65%~75%,对CODMn和SS的去除效果一般,去除率为40%~60%,对TP的去除效果随着时间推移逐渐减弱,碎石吸附对TP去除起主要作用。  相似文献   

13.
潜流人工湿地对污染物去除率的正交实验研究   总被引:1,自引:1,他引:0  
以湿地污染物去除率为考察指标,通过正交实验分析了植物、流量和水位对去除率的影响。结果表明:3种因素对BOD5、CODMn和TN去除率的影响一致,均为植物〉流量〉水位;植物是BOD5、CODMn和TN去除率的显著性影响因素,其中大薸对3种污染物的去除率显著高于凤眼莲,但其在9月底易发生二次污染,需要及早收割,流量是TN和CODMn去除率的显著性因素,水位为不显著因素;BOD5、CODMn和TN浓度在系统的前端下降速率较大,随后逐渐减小并趋于平稳,表明大部分污染物在湿地的前端被去除,湿地整体截污能力尚有较大提升空间。应用中可选择大薸在北方推广,并充分利用湿地后端潜能,最大化处理污染源水体。  相似文献   

14.
温度和基质对人工湿地脱氮除磷效果的影响   总被引:1,自引:0,他引:1  
构建由潜流人工湿地和表流人工湿地串联而成的复合人工湿地系统,研究了复合人工湿地脱氮除磷效果以及温度和基质对人工湿地脱氮除磷效果的影响。结果表明,复合人工湿地TP、氨氮平均去除率为33.64%、57.24%;水温降低会导致人工湿地氮磷去除率下降;基质为粗砂的潜流人工湿地脱氮除磷能力大于基质为砾石的潜流人工湿地。  相似文献   

15.
Constructed wetlands (CWs) are well recognized as having low construction and maintenance cost and low energy requirement. However, CW design has been mainly based on rule-of-thumb approaches. In this study, the efficiency of a modular horizontal subsurface flow (HSSF) CW using four different design schemes was investigated. Based on the results, the four systems have attained more than 90% removal of total suspended solids and more than 50% removal efficiency for total phosphorus, PO(4)-P and Zn. The planted system achieved higher pollutant removal rates than the unplanted system. In terms of media, bottom ash was more effective than woodchip in reducing the pollutants. Considering the flow length, optimum removal efficiency was achieved after passing the sedimentation tank and vertical media layer; with respect to depth, more pollutants were removed in the upper sand layer than in the lower gravel layer. This study recommended a surface area of 0.25 to 0.8% of catchment area for planted CW and 0.26 to 0.9% for unplanted CW using the 7.5 to 10 mm design rainfall.  相似文献   

16.
Pervious pavements are an effective stormwater treatment technology. However, their performance under variable drying and wetting conditions have yet to be tested, particularly under a continuous time scale. This paper reports on the clogging behaviour and pollutant removal efficiency of three pervious pavement types over 26 accelerated years. These pavements were monolithic porous asphalt (PA), Permapave (PP) and modular Hydrapave (HP). Over a cycle of 13 days, the period of which was equivalent to the average annual Brisbane, Australia rainfall (1,200 mm), the pavements were randomly dosed with four different flows. Drying events of 3 h duration were simulated during each flow. Inflow and outflow samples were collected and analysed for Total Suspended Solids (TSS), Total Phosphorus (TP) and Total Nitrogen (TN). To evaluate the rate of clogging, a 1 in 5 year Brisbane storm event was simulated in the 6th, 8th, 12th, 16th, 20th and 24th week. Under normal dosing conditions, none of the pavements showed signs of clogging even after 15 years. However, under storm conditions, both PA and HP started to clog after 12 years, while PP showed no signs of clogging after 26 years. The drying and various flow events showed no effects in TSS removal, with all systems achieving a removal of approximately 100%. The average TP removal was 20% for all flows except for low flow, which had a significant amount of leaching over time. Leaching from TN was also observed during all flows except high flow. The TSS, TP and TN results observed during storm events were similar to that of high flow.  相似文献   

17.
Low-cost household technologies, as horizontal subsurface flow constructed wetlands, are important to address water and sanitation needs in the Asia-Pacific region in a more integrated and sustainable manner, and a better understanding of these technologies would benefit their engineering design. Computational Fluid Dynamics (CFD) simulations of a modified constructed wetland system (EvaTAC) were undertaken to determine empirical effects of geometric and flow parameters on the hydraulic performance and the effluent pollutant fraction. The CFD model was validated by comparing the computed residence time distribution (RTD) with experimental results. RTD functions were then used to quantify hydraulic indexes: short-circuiting, mixing, and moment. The EvaTAC is composed of an evapotranspiration and treatment chamber (CEvaT) and a horizontal subsurface flow constructed wetland (HSSF-CW). For the CEvaT, length and the interaction between length and flow rate were the most important factors for the hydraulic efficiency. For the effluent pollutant fraction, the most important factor was flow rate. For the HSSF-CW, the strongest influence on the hydraulic efficiency was the length. Baffles and the interaction between length and baffles also had significant statistical influence on the hydraulic efficiency. Furthermore, the results showed that flow rate, length, and the interaction between flow rate and length influenced the effluent pollutant fraction significantly. Finally, a poor correlation between hydraulic indexes and effluent pollutant fraction was obtained, indicating that the hydraulic indexes are not good predictors of the effluent pollutant fraction.  相似文献   

18.
城市湖泊污水处理的实验分析   总被引:1,自引:1,他引:0  
以西安市兴庆湖为研究对象,对湖泊的水质进行了水平潜流和自由表面流净化的实验研究,比较了两种湿地的净化效果。在相同的水力负荷、水力停留时间、水深等条件下,分析了两种人工湿地对城市湖泊中的有机物、氮、磷等主要污染物的净化效果,及不同影响因素对系统处理效果的影响,比较了两种人工湿地的优缺点。  相似文献   

19.
In 2003, a subsurface flow constructed wetlands (SSF-CW) system was built at the University of Vermont (UVM) Paul Miller Dairy Farm as an alternative nutrient management approach for treating barnyard runoff and milk parlour waste. Given the increasing problem of phosphorus (P) pollution in the Lake Champlain region, a slag based P-removal filter technology (PFT) was established (2004) at the CW with two objectives: (i) to test the filters' efficiency as an upgrade unit for improving P removal performance via SSF-CW (ii) to investigate the capacity of filters technology to remove P as a "stand alone" unit. Six individual filters (F1-F6) were filled with electric arc furnace (EAF) steel slag, each containing 112.5 kg of material with a pore volume of 21 L. F1-F4, fed with CW treated water, received approximately 2.17 g DRP kg(-1) EAF steel slag (0.25 kg DRP total) during the 259 day feeding period. F1-F4 retained 1.7 g DRP kg(-1) EAF steel slag, resulting in an average P removal efficiency of 75%. The addition of filters improved CW DRP removal efficiency by 74%. F5 and F6, fed non-treated water, received 1.9 g DRP kg(-1) EAF steel slag (0.22 kg DRP in total) and retained 1.5 g DRP kg(-1) resulting in a P removal efficiency of 72%. The establishment of the EAF slag based PFT is the first in-field evaluation of this technology to reduce P from dairy farm effluent in Vermont.  相似文献   

20.
强降雨过程中入库面源污染对库区水质的影响   总被引:1,自引:0,他引:1  
为分析强降雨导致面源污染入库对库区水质的影响,以大伙房水库为例,构建库区三维水动力及水质模型,分析了强降雨过程中库区三维水动力及污染物浓度空间变化特征。结果表明:当入库流量较大时,库区水流场主要受吞吐流影响。污染团在水流输移作用下向下游迁移扩散,最大浓度及影响范围随时间先增加后逐步减小。当入库流量逐步减小时,吞吐流的影响逐步减弱,水流场变化受吞吐流和风生流共同支配。污染团在迁移过程中受此影响,浓度在三维方向呈现相应变化特征。研究结果可为制定更为切实可行的面源污染治理措施提供技术参考。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号