首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Large scale heat-driven absorption cooling systems are available in the marketplace for industrial applications but the concept of a solar driven absorption chiller for air-conditioning applications is relatively new. Absorption chillers have a lower efficiency than compression refrigeration systems, when used for small scale applications and this restrains the absorption cooling system from air conditioning applications in residential buildings. The potential of a solar driven ammonia–water absorption chiller for residential air conditioning application is discussed and analyzed in this paper. A thermodynamic model has been developed based on a 10 kW air cooled ammonia–water absorption chiller driven by solar thermal energy. Both energy and exergy analyses have been conducted to evaluate the performance of this residential scale cooling system. The analyses uncovered that the absorber is where the most exergy loss occurs (63%) followed by the generator (13%) and the condenser (11%). Furthermore, the exergy loss of the condenser and absorber greatly increase with temperature, the generator less so, and the exergy loss in the evaporator is the least sensitive to increasing temperature.  相似文献   

2.
The objective of this paper is to experimentally determine the efficiency and viability of the performance of an advanced trigeneration system that consists of a micro gas turbine in which the exhaust gases heat hot thermal oil to produce cooling with an air cooled absorption chiller and hot water for heating and DHW. The micro gas turbine with a net power of 28 kW produces around 60 kW of heat to drive an ammonia/water air-cooled absorption chiller with a rated capacity of 17 kW. The trigeneration system was tested in different operating conditions by varying the output power of the micro gas turbine, the ambient temperature for the absorption unit, the chilled water outlet temperature and the thermal oil inlet temperature. The modelling performance of the trigeneration system and the electrical modelling of the micro gas turbine are presented and compared with experimental results. Finally, the primary energy saving and the economic analysis show the advantages and drawbacks of this trigeneration configuration.  相似文献   

3.
A silica gel–water adsorption chiller integrated with a closed wet cooling tower is proposed. This adsorption chiller consists of two vacuum chambers, each with one adsorber, one condenser and one evaporator. Vacuum valves were not adopted in this chiller in order to enhance the reliability. A novel heat recovery process was carried out after a mass recovery-like process to improve the coefficient of performance (COP). Integration of the closed wet cooling tower into the chiller could ensure the cleanliness of cooling water circulating in the chiller and also promote the convenient setup of the chiller. A transient one-dimensional mathematical model was adopted to study this adsorption chiller. The simulated results showed that the cooling power and COP were 10.76 kW and 0.51 respectively when the hot water inlet temperature, the chilled water inlet temperature, the air inlet wet bulb temperature and dry bulb temperature were 85, 15, 28 and 30 °C respectively.  相似文献   

4.
Z. Wang  Z. Duan  X. Zhao  M. Chen 《Solar Energy》2012,86(5):1632-1647
This paper reported a dedicated study of a novel façade-based solar loop heat pipe (LHP) water heating system using both theoretical and experimental methods. This system employs a modular panel incorporating a unique loop heat pipe that is able to serve as part of the building façade or a decoration layer of the façade, thus creating a façade integrated, low cost, highly efficient and aesthetically appealing solar water heating structure. Taking into account heat balances occurring in different parts of the system, e.g., solar absorber, heat pipes loop, heat exchanger and storage tank, a dedicated computer model was developed to investigate the dynamic performance of the system. An experimental rig was also established to evaluate the performance of such a prototype system through measurement of various operational parameters, e.g., solar radiation, temperatures and flow rates of the heat pipe fluid and water. Through comparison between the testing and modelling results, the model has been approved to be able to give a reasonable accuracy for predicting the performance of the LHP system. Two types of glass covers, i.e., double glazed/evacuated tubes and single-glazing plate, were applied to the prototype. It was found that for both covers, the heat pipe fluid temperature rose dramatically at the start-up operation and afterwards remained a slow but steady growth; while the water temperature remained a steadily growing trend throughout the operational day. The temperature rise of the circulated water at 1.6 l/min of flow rate was around 13.5 °C in the double-glazed/evacuated tubes based system and 10 °C in the single-glazing based system; correspondingly, their average solar conversion efficiencies were 48.8% and 36%, and the COPs were 14 and 10.5 respectively. In overall, the double-glazed/evacuated tubes based system presented a better performance than the single glazing based one.  相似文献   

5.
This paper presents an optimization study of a single stage absorption machine operating with an ammonia–water mixture under steady state conditions. The power in the evaporator, the temperatures of the external fluids entering the four external heat exchangers as well as the effectiveness of these heat exchangers and the efficiency of the pump are assumed fixed. The results include the minimum value of the total thermal conductance UAtot as well as the corresponding mean internal temperatures, overall irreversibility and exergetic efficiency for a range of values of the coefficient of performance (COP). They show the existence of three optimum values of the COP: the first minimises UAtot, the second minimises the overall irreversibility and the third maximises the exergetic efficiency. They also show that these three COP values are lower than the maximum COP which corresponds to the convergence of the internal and external temperatures towards a common value. The influence of various parameters on the minimum thermal conductance of the heat exchangers and on the corresponding exergy efficiency has also been evaluated. From an exergetic viewpoint it is interesting to reduce the temperature at the desorber and at the evaporator and to raise the values of that parameter at the condenser and the absorber. However these changes must be accompanied by an important increase in the total UA if it is desired to conserve a constant COP. The internal heat exchangers between the working fluid and the solution improve both the overall exergy efficiency and the coefficient of performance of the absorption apparatus.  相似文献   

6.
7.
Experimental investigation of heat transfer, friction factor and thermal performance of thermosyphon solar water heater system fitted with helical and Left–Right twist of twist ratio 3 has been performed and presented. The helical twisted tape induces swirl flow inside the riser tubes unidirectional over the length. But, in Left–Right system the swirl flow is bidirectional which increases the heat transfer and pressure drop when compared to the helical system. The experimental heat transfer and friction factors characteristics are validated with theoretical equations and the deviation falls with in the acceptable limits. The results show that heat transfer enhancement in twisted tape collector is higher than the plain tube collector. Compared to helical and Left–Right twisted tape system of same twist ratio 3, maximum thermal performance is obtained for Left–Right twisted tape collector with increase in solar intensity.  相似文献   

8.
This paper presents a study on the NH3–H2O distillation process using a packed column with liquid reflux from the condenser in an absorption refrigeration system. A differential mathematical model has been developed on the basis of mass and energy balances and the heat and mass transfer equations. A net molar flux between the liquid and vapour phases has been considered in the mass transfer equation, which obviates the need to assume equimolar counter-diffusion. The model equations have been solved using the finite-difference method. Results obtained for a specific application are shown, including parameter distributions along the column length. The influence of rectifying and stripping lengths, mass and heat transfer coefficients and volumetric heat rejection from the column, on the distillate ammonia concentration has been analysed.  相似文献   

9.
《Applied Thermal Engineering》2005,25(2-3):359-375
A newly developed adsorption water chiller is described and tested. In this adsorption refrigeration cycle system, there is no refrigerant valve. Thus, the problem of mass transfer resistance occurring in the conventional systems when methanol or water is used as refrigerant and resulting in pressure drop during the flow of refrigerant inside the tubing is eliminated. To make the utilization of low heat source with temperature ranging from 70 to 95 °C possible, silica gel–water was selected as working pair. The experimental results proved that it is able to produce a cooling power of 6.3 kW with a COP of about 0.4. The test results demonstrate that, through the heat recovery, the COP can be increased by 34.4% while mass recovery has the effect of increasing the cooling power by 13.7% and the COP by 18.3%. The performances of the system were analyzed for varied condensation temperature and for varied evaporation temperature. Based on the first prototype, the second prototype is designed and manufactured to improve the performance. Primary test results demonstrate that the performance is highly improved. It has a COP of about 0.5 and cooling power 9 kW for 13 °C evaporation temperature.  相似文献   

10.
A dynamic model has been developed to simulate dynamic operation of a real double-effect absorption chiller. Dynamic behavior of working fluids in main components was modeled in first-order nonlinear differential equations based on heat and mass balances. Mass transport mechanisms among the main components were modeled by valve throttling, ‘U’ tube overflow and solution sub-cooling. The nonlinear dynamic equations coupled with the subroutines to calculate thermodynamic properties of working fluids were solved by a numerical method. The dynamic performance of the model was compared with the test data of a commercial medium chiller. The model showed a good agreement with the test data except for the first 83 min during which different flow rates of the weak solution caused some discrepancy. It was found that the chiller dynamics is governed by the inlet temperatures of the cooling water and the chilled water when the heat input to the chiller is relatively constant. For a step change of load at constant inlet temperatures of the cooling water and the chilled water, the response time of the chilled water exit temperature was about 15 min and it was due to the thermal capacities of the chiller. The dilution cycle was found to be an essential means for improvement of control performance as well as anti-crystallization.  相似文献   

11.
《Applied Thermal Engineering》2002,22(9):1027-1036
The comparisons of coefficient of performance and the cyclic characteristics between the three-pressure absorption–ejector hybrid refrigeration system (AEHRS) and small double-effect absorption refrigeration system are carried out. The thermo-economical analysis models of the two systems in two cases of high-temperature heat resources: waste heat resources and natural gas fuel are presented. The thermo-economical performances of the two systems in two modes of the running hours per year (600 and 1000 h) are calculated and discussed to show the commercial perspective of the AEHRS.  相似文献   

12.
13.
A one-dimensional, steady state model for absorption of ammonia vapor into a constrained microscale film is presented. A weak solution of ammonia–water flows in a microchannel into which ammonia vapor bubbles are injected in cross flow from a porous wall. A counter flowing coolant solution removes the heat generated due to absorption from the opposite wall. The 1-D, steady state species and energy transport equations are solved to yield, along the length of the channel, concentration and temperature profiles of the solution stream and the temperature profile of the coolant fluid stream. The model is validated from experimental measurements of global parameters. A parametric study of fluid and geometrical parameters based on the validated model is presented. Results show that a balance between the residence time within the absorber and the absorption time scales, by way of adjusting the mass flow rates of the vapor and weak solution, is needed to ensure complete absorption. A lower coolant inlet temperature significantly enhances absorption rate by increasing the local concentration difference between the saturation and bulk values. The absorption rate is more sensitive to the liquid–vapor interfacial area than to the heat transfer area between the solution and the coolant.  相似文献   

14.
15.
《Energy》1998,23(5):347-353
Solar-powered adsorption cooling is an attractive solar energy application. Metallic solar collectors with fins have been used to increase the thermal conductivity in solar collectors. This approach has a negative effect due to solar energy loss by reflection and heat loss resulting from the sensible heat of the metal. For these reasons, a direct-radiation absorption collector is proposed here. The effects of the wavelength of the absorbed light, types of silica gel used and additives to improve the absorptivity have been investigated. We have verified that blue silica gel has a better absorptivity in the near-infrared region than white silica gel. The addition of activated carbon to the silica gel improves the desorption rate and regeneration temperature of the packed bed.  相似文献   

16.
In this study, a lumped parameter simulation model has been developed for analysis of the thermal performance of a single-stage two-bed adsorption chiller. Since silica gel has low regeneration temperature and water has high latent heat of vaporisation, silica gel–water pair has been chosen as the working pair of the adsorption chiller. Low-grade waste heat or solar heat at around 70–80°C can be used to run this adsorption chiller. In this model, the effects of operating parameters on the performance of the chiller have been studied. The simulated results show that the cooling capacity of the chiller has an optimum value of 5.95?kW for a cycle time of 1600?s with the hot, cooling, and chilled water inlet temperatures at 85°C, 25°C, and 14°C, respectively. The present model can be utilised to investigate and optimise adsorption chillers.  相似文献   

17.
The development of absorption chillers activated by renewable heat sources has increased due mainly to the increase in primary energy consumption that causes problems such as greenhouse gases and air pollution among others. These machines, which could be a good substitute for compression systems, could be used in the residential and food sectors which require a great variety of refrigeration conditions. Nevertheless, the low efficiency of these machines makes it necessary to enhance heat and mass transfer processes in the critical components, mainly the absorber, in order to reduce their large size.This study used ammonia–water as the working fluid to look at how absorption takes place in a plate heat exchanger operating under typical conditions of absorption chillers, driven by low temperature heat sources. Experiments were carried out using a corrugated plate heat exchanger model NB51, with three channels, where ammonia vapor was injected in bubble mode into the solution in the central channel. The results achieved for the absorption flux were in the range of 0.0025–0.0063 kg m?2 s?1, the solution heat transfer coefficient varied between 2.7 and 5.4 kW m?2 K?1, the absorber thermal load from 0.5 to 1.3 kW. In addition, the effect of the absorber operating conditions on the most significant efficiency parameters was analyzed. The increase in pressure, solution and cooling flow rates positively affect the absorber performance, on the other hand an increase in the concentration, cooling, and solution temperature negatively affects the absorber performance.  相似文献   

18.
Performance of the absorption cooling system is still a challenge due to the coefficient of performance (COP) that is generally poor when compared with the conventional vapor compression cycle. High solar radiation in hot climates is usually associated with high ambient temperature and consequently peak cooling demand. Absorption cooling cycles can be powered by solar but the performance is limited by heat source temperature (solar collector) and high ambient temperature that can affect the condensation process. Efficiency enhancement of the system components is essential to increase the COP of the system. A modification in the combined absorption–ejector cooling system is adopted. Adding a removable flash tank between the condenser and evaporator could improve entrainment ratio of the ejector, along with improving the cooling effect inside the evaporator. A computer simulation program is developed to evaluate the performance of the modified combined cycle using aqua-ammonia (NH3–H2O) refrigerant. The performance of the proposed combined cooling cycle is compared with basic absorption, and combined absorption–ejector cooling cycles. Results showed a significant improvement in the COP of the modified cycle at different operating conditions. Cooling effect and capacity of the evaporator is enhanced due to the reduction of flash gas delivered to the evaporator. Furthermore, the flash tank optimized the ejector entertainment ratio and consequently increasing the condenser pressure. This optimization will enable the system to perform well in hot climates where the condenser efficiency is limited by ambient temperature.  相似文献   

19.
《Applied Energy》2002,71(3):147-160
We present an assessment of installing a regional heating and cooling system in the Nishi(West)-Shinjuku area of Tokyo, Japan. In this assessment, we estimate the CO2 payback–time, when air source heat–pumps (ASHP) are replaced with a ground–source heat–pump (GSHP) system. We calculate CO2 emissions from transportation of the cooling tower, materials for the underground heat exchanger, and the digging loads and transportation loads incurred when the GSHP system is installed to replace the air source cooling system. The total CO2 emission from the installation of the GSHP system was estimated to be 67,701t-CO2, with 87% of the CO2 emissions resulting from the digging process. CO2 emissions from the operation of the GSHP system were estimated from the total energy-efficiency of the system and the heating and cooling demand in Nishi-Shinjuku area. Using the GSHP system, 33,935t-CO2 would be emitted per year. We estimate that using the GSHP system would result in a reduction of 54% of the CO2 emissions, or 39,519t-CO2 per year. From these results, the CO2 payback–time for replacing the conventional ASHP in the 1 km2 studied region with the GSHP system is assessed to be 1.7 years.  相似文献   

20.
In this study, a thermally driven adsorption cooling unit using natural zeolite–water as the adsorbent–refrigerant pair has been built and its performance investigated experimentally at various evaporator temperatures. The primary components of the cooling unit are a shell and tube adsorbent bed, an evaporator, a condenser, heating and cooling baths, measurement instruments and supplementary system components. The adsorbent bed is considered to enhance the bed’s heat and mass transfer characteristics; the bed consists of an inner vacuum tube filled with zeolite (zeolite tube) inserted into a larger tubular shell. Under the experimental conditions of 45 °C adsorption, 150 °C desorption, 30 °C condenser and 22.5 °C, 15 °C and 10 °C evaporator temperatures, the COP of the adsorption cooling unit is approximately 0.25 and the maximum average volumetric cooling power density (SCPv) and mass specific cooling power density per kg adsorbent (SCP) of the cooling unit are 5.2 kW/m3 and 7 W/kg, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号