In this study, performance assessment of an integrated cooling plant having both free cooling system and solar powered single-effect lithium bromide–water absorption chiller in operation since August 2002 in Oberhausen, Germany, was performed. A floor space of 270 m2 is air-conditioned by the plant. The plant includes 35.17 kW cooling (10-RT) absorption chiller, vacuum tube collectors’ aperture area of 108 m2, hot water storage capacity of 6.8 m3, cold water storage capacity of 1.5 m3 and a 134 kW cooling tower. The results show that free cooling in some cooling months can be up to 70% while it is about 25% during the 5 years period of the plant operation. For sunny clear sky days with equal incident solar radiation, the daily solar heat fraction ranged from 0.33 to 0.41, collectors’ field efficiency ranged from 0.352 to 0.492 and chiller COP varies from 0.37 to 0.81, respectively. The monthly average value of solar heat fraction varies from 31.1% up to 100% and the five years average value of about 60%. The monthly average collectors’ field efficiency value varies from 34.1% up 41.8% and the five-year average value amounts about 28.3%. Based on the obtained results, the specific collector area is 4.23 (m2/kWcold) and the solar energy system support of the institute heating system for the duration from August 2002 to November 2007 is 8124 kWh.  相似文献   

2.
A solar-powered adsorption chiller with heat and mass recovery cycle was designed and constructed. It consists of a solar water heating unit, a silica gel-water adsorption chiller, a cooling tower and a fan coil unit. The adsorption chiller includes two identical adsorption units and a second stage evaporator with methanol working fluid. The effects of operation parameter on system performance were tested successfully. Test results indicated that the COP (coefficient of performance) and cooling power of the solar-powered adsorption chiller could be improved greatly by optimizing the key operation parameters, such as solar hot water temperature, heating/cooling time, mass recovery time, and chilled water temperature. Under the climatic conditions of daily solar radiation being about 16–21 MJ/m2, this solar-powered adsorption chiller can produce a cooling capacity about 66–90 W per m2 collector area, its daily solar cooling COP is about 0.1–0.13.  相似文献   

3.
《Energy Conversion and Management》2005,46(13-14):2032-2041
A solar adsorption ice maker with activated carbon–methanol adsorption pair was developed for a practical application. Its main features include utilization of a water cooled condenser and removing all valves in the refrigerant circuit except the one that is necessary for refrigerant charging. Year round performance tests of the solar ice maker were performed in Kunming, Yunnan Province, China. Test results show that the COP (coefficient of performance) of the solar ice maker is about 0.083–0.127, and its daily ice production varies within the range of 3.2–6.5 kg/m2 under the climatic conditions of daily solar radiation on the surface of the adsorbent bed being about 15–23 MJ/m2 and the daily average ambient temperature being within 7.7–21.1 °C. The suitable daily solar radiation under which the solar ice maker can run effectively in Kunming is above 16 MJ/m2.  相似文献   

4.
Despite its attractiveness, solar cooling technology is still in an early stage of development. Most installations currently in operation show differences in the collector area per kilowatt of cooling capacity that cannot be explained only by project-specific circumstances. The purpose of this paper was twofold. First, to answer some questions that came up during the design process of the plant by using a TRNSYS system model and statistical tools. Second, to gain knowledge about the plant operation and validate the TRNSYS model through measured data. The system was equipped with a flat-plate collector field of 38.4 m2. A lithium bromide-water single-effect absorption chiller (17.6 kW) was selected in order to provide chilled water to fan-coils. Performance data were registered at the solar plant working with a 1000-l heat storage tank and a required temperature of 80 °C to drive the absorption machine. An average of 29% of the solar energy incident on the solar collectors’ surface was transferred to the hot water storage. The registered average COP of the absorption chiller was 0.691. The performance data were compared with the values predicted by the TRNSYS plant model and a high level of agreement was obtained.  相似文献   

5.
Viability of solar photovoltaics as an electricity generation source for Jordan was assessed utilizing a proposed 5 MW grid-connected solar photovoltaic power plant. Long-term (1994–2003) monthly average daily global solar radiation and sunshine duration data for 24 locations – distributed all over the country – were studied and analyzed to assess the distribution of radiation and sunshine duration over Jordan, and formed an input data for evaluation and analysis of the proposed plant's electricity production and economic feasibility. It was found that – depending on the geographical location – the global solar radiation on horizontal surface varied between 1.51 and 2.46 MWh/m2/year with an overall mean value of 2.01 MWh/m2/year for Jordan. The sunshine duration was found to vary – according to the location – between 8.47 and 9.68 h/day, with a mean value of 9.07 h/day and about 3311 sunshine hours annually for Jordan. The annual electricity production of the proposed plant varied depending on the location between 6.886 and 11.919 GWh/year, with a mean value of 9.46 GWh/year. The specific yield varied between 340.9 and 196.9 kWh/m2, while the mean value was 270.59 kWh/m2. Analysis of the annual electricity production of the plant, the specific yield, besides the economic indicators i.e., internal rate of return, simple payback period, years– to- positive cash flow, net present value, annual life cycle saving, benefit–cost ratio, and cost of energy – for all sites – showed that Tafila and Karak are the most suitable sites for the solar photovoltaic power plant's development and Wadi Yabis is the worst. The results also showed that an average of 7414.9 tons of greenhouse gases can be avoided annually utilizing the proposed plant for electricity generation at any part of Jordan.  相似文献   

6.
Solar water disinfection using the solar water disinfection (SODIS) method is not a well-known technique in Brazil. The objective of the study was to investigate the effectiveness of a solar energy concentrator made of cardboard and covered with aluminium foil in heating water in transparent and black-backed PET reactors and to compare the efficiency of these reactors with those that are used on asbestos roofing. The efficiency of the method was evaluated for a year with monthly in loco readings and through analysis of the local weather where the study was performed. The black-backed PET reactors in the solar concentrator were better at heating water than any of the other treatments, both on strong and moderate weather days. On weak weather days, however, these reactors did not heat the water enough for solar disinfection to take place. Disinfection of polluted river water samples was evaluated in black-backed solar reactors. The most probable number (MPN) of thermotolerant coliform bacteria and Escherichia coli in water collected from the river were measured using the multiple tube fermentation technique before and after solar treatment. River water samples exposed to 3 h of solar radiation on moderate weather days had 99.9% inactivation of faecal coliforms (E. coli) when the water reached more than 50 °C (average 6 h peaks of radiation – 685.6 W/m2). However, inactivation of faecal coliforms was not observed in reactors exposed to solar radiation in the same weather conditions on asbestos roofing. A computer simulation of water heating was carried out using a dynamic fluid model based on the diffusion equation. The computational model produced temperature values similar to the experimental curves (r2 = 0.99). The results suggest that using a specific radiation data set, the behaviour of water temperature in the PET reactors can be accurately predicted. Therefore, it may be possible to make predictions about water purification by the SODIS method in southeastern Brazil, where there are similar weather conditions.  相似文献   

7.
An analytical investigation has been performed to study the possibility of application of solar cooling for the climatic condition of Tokyo, Japan. Silica gel–water adsorption cooling system has been taken into consideration for the present study and lumped parameter model is used to investigate the performance of the system. Based on the solar radiation data it is found that at least 15 collector (each of 2.415 m2) is required to achieve the required heat source temperature (around 85 °C) to run the cooling unit. It is also observed that the solar powered adsorption cooling unit provides cooling capacity around 10 kW at noon with base run conditions, while the system provides solar COP around 0.3, however, the solar collector size can be reduced by optimizing the cycle time.  相似文献   

8.
A solar adsorption cooling system was constructed in the green building of Shanghai Institute of Building Science. The system consisted of evacuated tube solar collector arrays of area 150 m2, two adsorption chillers with nominal cooling capacity of 8.5 kW for each and a hot water storage tank of 2.5 m3 in volume. A mathematical model of the system was established. According to experimental results under typical weather condition of Shanghai, the average cooling capacity of the system was 15.3 kW during continuous operation for 8 h. The theoretical analysis of the system was verified and found to agree well with the experimental results. The performance analysis showed that solar radiant intensity had a more distinct influence on the performance of solar adsorption cooling system as compared with ambient temperature. It was observed that the cooling capacity increased with the increase of solar collector area, whereas, solar collecting efficiency varied quite contrary. With the increase of water tank volume, cooling capacity decreased, while, the solar collecting efficiency increased. The system performances can be enhanced by increasing the height-to-diameter ratio of water tank. Additionally, it was observed that solar collecting efficiency decreased with the increase of the initial temperature of water in the tank; however, cooling capacity varied on the contrary. Also can be seen is that optimum nondimensional mass flow rate is 0.7 when the specific mass flow rate exceeds 0.012 kg/m2 s.  相似文献   

9.
Accurate measurement of solar radiation heat flux is important in characterizing the performance of CSP plants. Thermopile type Heat Flux Sensors (HFSs) are usually used for this purpose. These sensors are typically reasonably accurate at high heat fluxes. However measurement accuracy drops significantly as the measured radiation is below 1 kW/m2, this often leads to underestimation of the actual flux. At the Masdar Institute Beam Down Solar Thermal Concentrator (BDSTC), measurement of fluxes ranging from 0 kW/m2 to more than 100 kW/m2 is required. To improve the accuracy of the sensors in the lower range around 1 kW/m2, we have performed a test under ambient (not-concentrated) sunlight. Such low irradiation levels are experienced in characterizing the concentration quality of individual heliostats. It was found during the test that the measurement at this low range is significantly affected by ambient conditions and transients in the HFS cooling water temperature. A Root Mean Square Error (RMSE) of more than 100 W/m2 was observed even though we kept the transients in water temperature to a minimum. Hence we devised a model to account for this measurement error at this flux range. Using the proposed model decreased the RMSE to less than 10 W/m2. The application of the model on existing heat flux measurement installations is facilitated by the fact that it only employs easily measurable variables. This model was checked by using a test data set and the results were in good agreement with the training data set.  相似文献   

10.
An extensive indoor experimental characterisation program to investigate the heat loss from a point focus Fresnel lens PV Concentrator (FPVC) with a concentration ratio of 100× was performed for a range of simulated solar radiation intensities between 200 and 1000 W/m2, different ambient air temperatures, and natural and forced convection. From the experimental program it was found that the solar cell temperature increased proportionally with the increase in simulated solar radiation for all experimental tests, indicating that conductive and convective heat transfer were significantly larger than the long wave radiative heat transfer within and from the FPVC system. For the simulated worst case scenario, in which the FPVC system was tested under a simulated solar radiation intensity of 1000 W/m2 and ambient air temperature of 50 °C with no forced convection, the predicted silicon solar cell efficiency in the FPVC system was reduced to approximately half that at standard test conditions.  相似文献   

11.
Solar thermal driven cooling systems for residential applications are a promising alternative to electric compression chillers, although its market introduction still represents a challenge, mainly due to the higher investment costs. The most common system configuration is an absorption chiller driven by a solar thermal system, backed up by a secondary heating source, normally a gas boiler. Heat storage in the primary (solar) circuit is mandatory to stabilize and extend the operation of the chiller, whereas a cold storage tank is not so common.This paper deals with the selection of the most suitable configuration for residential cooling systems with solar energy. In Spain, where cooling needs are usually higher than heating needs, the interest of a reversible heat pump as auxiliary system and a secondary cooling storage are analyzed.A complete TRNSYS model has been developed to compare a configuration with just hot storage (of typical capacity 40 L/m2 of solar collector surface) and a configuration with both, hot and cool storages. The most suitable configuration is very sensible to the solar collector area. As the collector area increases, the advantages of a cool storage vanish. Increasing the collector area tends to increase the temperature of the hot storage, leading to higher thermal losses in both the collector and the tank. When the storage volume is concentrated in one tank, these effects are mitigated. The effect of other variables on the optimal configuration are also analyzed: collector efficiency curve, COP of the absorption chiller, storage size, and temperature set-points of the chillers.  相似文献   

12.
Ahmed A.A. Attia 《Solar Energy》2012,86(9):2486-2493
As Natural resources are becoming limited and energy price dramatically increased, energy utilization with efficient systems is essentially required to be used in desalination technologies. The use of solar energy in desalination processes is one of the most promising applications of renewable energies. The primary focus on desalination by solar energy is suitable for use in remote areas. A proposed desalination system uses solar radiation, which concentrated by parabolic dish to heat up the working fluid in a closed space. Then the generated pressure in this space used to push salt water into RO module.Daily production rate of fresh water quantity for suggested system compared with other solar techniques is a promising rate for each m2 of solar radiation collecting surface. The production rate for one operation cycle could reach to 1800 L/cycle of fresh water at low water salinity (Brackish water with 5000 ppm) and 55 L/cycle at highest water salinity (sea water salinity with 42,000 ppm). The required energy needed to produce 1 kg of fresh water is also promising even when in case of using another type of energy, also operating cycle has ability of repetition according to salinity concentration through sunny hours.  相似文献   

13.
Institutional buildings contain different types of functional spaces which require different types of heating, ventilating and air conditioning (HVAC) systems. In addition, institutional buildings should be designed to maintain an optimal indoor comfort condition with minimal energy consumption and minimal negative environmental impact. Recently there has been a significant interest in implementing desiccant cooling technologies within institutional buildings. Solar desiccant cooling systems are reliable in performance, environmentally friendly and capable of improving indoor air quality at a lower cost. In this study, a solar desiccant cooling system for an institutional building in subtropical Queensland (Australia) is assessed using TRNSYS 16 software. This system has been designed and installed at the Rockhampton campus of Central Queensland University. The system's technical performance, economic analysis, energy savings, and avoided gas emission are quantified in reference to a conventional HVAC system under the influence of Rockhampton's typical meteorological year. The technical and economic parameters that are used to assess the system's viability are: coefficient of performance (COP), solar fraction, life cycle analysis, payback period, present worth factor and the avoided gas emission. Results showed that, the installed cooling system at Central Queensland University which consists of 10 m2 of solar collectors and a 0.400 m3 of hot water storage tank, achieved a 0.7 COP and 22% of solar fraction during the cooling season. These values can be boosted to 1.2 COP and 69% respectively if 20 m2 of evacuated tube collector's area and 1.5 m3 of solar hot water storage volume are installed.  相似文献   

14.
《Energy》2005,30(7):933-951
We present the energy use situation in Hong Kong from 1979 to 2001. The primary energy requirement (PER) nearly tripled during the 23-year period, rising from 195,405 TJ to 572,684 TJ. Most of the PER was used for electricity generation, and the electricity use in residential buildings rose from 7556 TJ (2099 GWh) to 32,799 TJ (9111 GWh), an increase of 334%. Air-conditioning accounted for about 40% of the total residential sector electricity consumption. A total of 144 buildings completed in the month of June during 1992–2001 were surveyed. Energy performance of the building envelopes was investigated in terms of the overall thermal transfer value (OTTV). To develop the appropriated parameters used in OTTV calculation, long-term measured weather data such as ambient temperature (1960–2001), horizontal global solar radiation (1992–2001) and global solar radiation on vertical surfaces (1996–2001) were examined. The OTTV found varied from 27 to 44 W/m2 with a mean value of 37.7  W/m2. Building energy simulation technique using DOE-2.1E was employed to determine the cooling requirements and hence electricity use for building envelope designs with different OTTVs. It was found that cooling loads and electricity use could be expressed in terms of a simple two-parameter linear regression equation involving OTTV.  相似文献   

15.
This paper discusses solar power prospects in Wilayat Duqum in Oman. First, the geographic and topographic information about the selected region is presented. The methodology of producing solar radiation map for Duqum using GIS tools is then presented. The results obtained show very high potential of solar radiation over Wilayat Duqum during the whole year. A slope analysis has allowed calculating the yearly electricity generation potential for different concentrated solar power (CSP) technologies such as the parabolic trough, parabolic dish, tower, and concentrated PV. Based on the development plan of the Duqum region, and the topologies of the land areas in the region, it is suggested that, for the CSP technologies requiring large amount of water for washing the mirrors, the selected area is a flat land (slope < 1%) located proximity to the sea (~2 km) inside a total industrial area of around 50 km2, hence, allowing easy future expansion of the plant. It was proposed to start with a 100 MW power plant which is expected to consume about 2.4 km2 of flat land for the parabolic trough CSP technology. The total calculated potential of yearly electricity generation would be about 2.3 TWh. If half of the selected land (0.5 × 50 km2) is reserved for future expansion of the plant, the total future capacity can attain 1 GW of electric power. The selected area can also accommodate in the future different types of CSP technologies as they mature with time.  相似文献   

16.
Solar photovoltaic (PV) hybrid system technology is a hot topic for R&D since it promises lot of challenges and opportunities for developed and developing countries. The Kingdom of Saudi Arabia (KSA) being endowed with fairly high degree of solar radiation is a potential candidate for deployment of PV systems for power generation. Literature indicates that commercial/residential buildings in KSA consume an estimated 10–45% of the total electric energy generated. In the present study, solar radiation data of Dhahran (East-Coast, KSA) have been analyzed to assess the techno-economic viability of utilizing hybrid PV–diesel–battery power systems to meet the load requirements of a typical commercial building (with annual electrical energy demand of 620,000 kW h). The monthly average daily solar global radiation ranges from 3.61 to 7.96 kW h/m2. NREL's HOMER software has been used to carry out the techno-economic viability. The simulation results indicate that for a hybrid system comprising of 80 kWp PV system together with 175 kW diesel system and a battery storage of 3 h of autonomy (equivalent to 3 h of average load), the PV penetration is 26%. The cost of generating energy (COE, US$/kW h) from the above hybrid system has been found to be 0.149 $/kW h (assuming diesel fuel price of 0.1 $/L). The study exhibits that for a given hybrid configuration, the operational hours of diesel generators decrease with increase in PV capacity. The investigation also examines the effect of PV/battery penetration on COE, operational hours of diesel gensets for a given hybrid system. Emphasis has also been placed on unmet load, excess electricity generation, percentage fuel savings and reduction in carbon emissions (for different scenarios such as PV–diesel without storage, PV–diesel with storage, as compared to diesel-only situation), cost of PV–diesel–battery systems, COE of different hybrid systems, etc.  相似文献   

17.
Investigating the complicated thermal physics mechanisms of the parabolic trough solar collector systems plays a vital role in efficiently utilizing the solar energy. In this paper, the least squares support vector machine (LSSVM) method is developed to model and optimize the parabolic trough solar collector system. Numerical simulations are implemented to evaluate the feasibility and efficiency of the LSSVM method, where the sample data derived from the experiment and the simulation results of two solar collector systems with 30 m2 and 600 m2 solar fields, and the complicated relationship between the solar collector efficiency and the solar flux, the flow rate and the inlet temperature of the heat transfer fluid (HTF) is extracted. Some basic rules, such as the solar collector efficiency increases with the increase of the solar flux and the flow rate of the heat transfer fluid, and decreases with the increase of the inlet temperature of the HTF, are obtained, which indicates the LSSVM method is competent to optimize the solar collector systems. As a result, the new approach will provide meaningful data for developing the parabolic trough solar thermal power plant in China.  相似文献   

18.
Australia is a country with a vast amount of natural resources including sun and wind. Australia lies between latitude of 10–45°S and longitude of 112–152°E, with a daily solar exposure of between less than 3 MJ/(m2 day) in winter and more than 30 MJ/(m2 day) in summer.Global solar radiation in Australia varies between minimum of 3285 MJ/(m2 year) in Hobart to 8760 MJ/(m2 year) in Northern Territory. As a result of this wide range of radiation level there will be a big difference between costs of solar PV electricity in different locations.A study we have recently conducted on the solar PV electricity price in all states of Australia. For this purpose we have developed an economical model and a computer simulation to determine the accurate unit price of grid-connected roof-top solar photovoltaic (PV) electricity in A$/kWh for all state of Australia. The benefit of this computer simulation is that we can accurately determine the most appropriate feed-in tariff of grid-connected solar PV energy system. The main objective of this paper is to present the results of this study.A further objective of this paper is to present the details of the unit price of solar PV electricity in the state of Victoria in each month and then to compare with electricity price from conventional power systems, which is currently applied to this state. The state Victoria is located south of Australia and in terms of sun radiation is second lowest compared with the other Australian states.The computer simulation developed for this study makes it possible to determine the cost of grid-connected solar PV electricity at any location in any country based on availability of average daily solar exposure of each month as well as economical factors of the country.  相似文献   

19.
Photovoltaic technology provides the direct method to convert solar energy into electricity. Modeling and simulation plays a very important role in the development of PV devices as well as in the design of PV systems. The objective of the current work was to develop a novel thermal model to simulate the thermal performance of PV modules with and without cooling. The model was sequentially coupled with a radiation model and an electrical model to calculate the electrical performance of the PV panels. Using the developed model, various studies were performed to evaluate the electrical and thermal performance of the module under different environmental and operating conditions with and without cooling. Results show that the performance of the PV panel with cooling had very little influence of increasing absorbed radiation (200–1000 W/m2) at a constant ambient temperature (25 °C) and increasing ambient temperature (0–50 °C) at an absorbed radiation of 800 W/m2. For the same variation in conditions, the performance of the panel without any cooling reduced significantly.  相似文献   

20.
When using passive solar heating systems, it is necessary to have available an Equator-facing facade on which to install them. Rooms without such a facade are not the best option for conventional passive solar heating systems. SIRASOL is a passive solar radiant system that captures solar energy and is to be installed in the ceiling of the room. This room must not necessarily have an Equator-facing facade. Solar energy heats up a metal sheet, which is the radiant panel, which transfers heat by long-wave radiation to the room below it. This paper presents a mathematical model and a sensitivity analysis. The mathematical model was used to analyze radiant panel temperature, radiant mean temperature, operative temperature and panel surface area. Results of the sensitivity study showed that when solar radiation rises (from 200 to 800 W) panel temperature increases from 36 °C to 92 °C, whereas variations in outside and inside air temperature have a negligible impact on the panel temperature. Thus, the use of SIRASOL is possible in locations with clear skies. Moreover, from panel temperature values we calculated mean radiant temperature and thereby the room’s operative temperature, which is proportional to the radiant panel area. When this area is 50% of the room’s floor area, operative temperature grows 3.1 °C higher than inside air temperature when solar radiation is 500 W/m2. The analysis shows that a thermal asymmetry appears only when SIRASOL’s surface area to floor area ratio is higher than 32%.  相似文献   