首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The innovative configuration of low temperature solar thermal electric generation with regenerative Organic Rankine Cycle (ORC) is designed, mainly consisting of small concentration ratio compound parabolic concentrators (CPC) and the regenerative ORC. Advantages of the innovative configuration such as effectively reducing heat transfer irreversibility and permitting the use of thermal storage with phase change materials (PCMs) are outlined. The numerical simulation of the heat transfer and power conversion processes are carried out based on distributed parameters. The effects of regenerative cycle on the collector, ORC, and overall electricity efficiency are then analyzed. The results indicate that the regenerative cycle has positive effects on the ORC efficiency but negative ones on the collector efficiency due to increment of the average working temperature of the first-stage collectors. Thus, it is necessary to evaluate the overall electricity efficiency when regenerative cycle is adopted. Further investigation shows that there are maximum efficiencies for both the ORC and the system electric generation on conditions of constant irradiance, evaporation temperature, and environment temperature. And the regenerative temperature at which the system electricity efficiency reaches its maximum is smaller than that at which the ORC efficiency reaches its maximum by 12–21 °C. Thus, the regenerative cycle optimization of the solar thermal electric generation differs from that of a solo ORC. The system electricity efficiency with regenerative ORC is about 8.6% for irradiance 750 W/m2 and is relatively higher than that without the regenerative cycle by 4.9%.  相似文献   

2.
A solar-powered adsorption chiller with heat and mass recovery cycle was designed and constructed. It consists of a solar water heating unit, a silica gel-water adsorption chiller, a cooling tower and a fan coil unit. The adsorption chiller includes two identical adsorption units and a second stage evaporator with methanol working fluid. The effects of operation parameter on system performance were tested successfully. Test results indicated that the COP (coefficient of performance) and cooling power of the solar-powered adsorption chiller could be improved greatly by optimizing the key operation parameters, such as solar hot water temperature, heating/cooling time, mass recovery time, and chilled water temperature. Under the climatic conditions of daily solar radiation being about 16–21 MJ/m2, this solar-powered adsorption chiller can produce a cooling capacity about 66–90 W per m2 collector area, its daily solar cooling COP is about 0.1–0.13.  相似文献   

3.
Current in solar chimney power plant that drives turbine generators to generate electricity is driven by buoyancy resulting from higher temperature than the surroundings at different heights. In this paper, the maximum chimney height for convection avoiding negative buoyancy at the latter chimney and the optimal chimney height for maximum power output are presented and analyzed using a theoretical model validated with the measurements of the only one prototype in Manzanares. The results based on the Manzanares prototype show that as standard lapse rate of atmospheric temperature is used, the maximum power output of 102.2 kW is obtained for the optimal chimney height of 615 m, which is lower than the maximum chimney height with a power output of 92.3 kW. Sensitivity analyses are also performed to examine the influence of various lapse rates of atmospheric temperatures and collector radii on maximum height of chimney. The results show that maximum height gradually increases with the lapse rate increasing and go to infinity at a value of around 0.0098 K m?1, and that the maximum height for convection and optimal height for maximum power output increase with larger collector radius.  相似文献   

4.
In this paper, a novel composite sorbent “lithium chloride in silica gel pores” is proposed for application in solar-powered adsorptive ice makers. A mathematical model was used in order to calculate the performance of an ice-maker using this material as adsorbent and methanol as adsorbate. The results of the model showed that a maximum solar coefficient of performance (COPs) of 0.33 and a maximum daily ice production (DIP) of 20 kg m?2 can be obtained for an ice-maker equipped with a solar collector area of 1.5 m2 and 36 kg of adsorbent material. Such performance are noticeably higher than those obtained using commercial activated carbon, that is the adsorbent mostly proposed till now.  相似文献   

5.
In the green building of Shanghai Research Institute of Building Science, the evacuated tubular solar collectors with a total area of 150 m2 were installed to provide heating for the covered area of 460 m2. The floor heating coil pipes were made of high-quality pure copper with the dimension of Φ 12 × 0.7 mm. Under typical weather condition of Shanghai, the average heating capacity was 25.04 kW during the working hours from 9:00 to 17:00, which was sufficient to keep indoor thermal environment. The average electric COP of the floor heating system was 19.76 during the system operation. Compared with the widely used air-source heat pump heating systems with the electric COP of 3.5 in Shanghai, the solar-powered floor heating system shows great potential in energy conservation in winter. With respect to the whole heating period, the solar fraction was 56%. According to the performance analysis of the system with ambient parameters, it was observed that the system performance could be greatly enhanced with the increase of daily solar insolation. However, the system performance varied slightly with average ambient temperature. Compared with average ambient temperature, daily solar insolation had a more distinct influence on the performance of the solar-powered floor heating system.  相似文献   

6.
《Applied Energy》2007,84(9):971-983
Performance variations of a solar-powered ejector cooling-system (SECS) using an evacuated-tube collector are presented for Antalya, Aydin, Konya and Urfa cities located in the southern region of Turkey by means of hourly and monthly average ambient temperature and solar radiation meteorological data. A SECS, based on a constant-area ejector flow model and using R-123, was considered. The cooling season and period were taken into account for the 6 months (May–October) and the hours 8:00–17:00, respectively. It was found that the evacuated-tube collector efficiency depending upon the ambient temperature and solar radiation within the day was remarkably varied. However, for all the cities, the cooling capacities of the SECS were very similar. When generator, condenser, and evaporator temperatures were taken, namely, 85 °C, 30 °C and 12 °C, the maximum overall coefficient of performance and the cooling capacity were obtained as 0.197 and 178.26 W/m2, respectively, at 12:00 in August for Aydin. The evacuated-tube collector area per ton cooling was found to be around 21 m2 at noontime in August for all the cities. Furthermore, at the off-design conditions, a performance map of the system was derived and discussed. It was determined that the SECS could be used for office-cooling purposes during the hours (8:00–15:00) in the southern region of Turkey.  相似文献   

7.
In this paper, a solar-powered compound system for heating and cooling was designed and constructed in a golf course in Taiwan. An integrated, two-bed, closed-type adsorption chiller was developed in the Industrial Technology Research Institute in Taiwan. Plate fin and tube heat exchangers were adopted as an adsorber and evaporator/condenser. Some test runs have been conducted in the laboratory. Under the test conditions of 80 °C hot water, 30 °C cooling water, and 14 °C chilled water inlet temperatures, a cooling power of 9 kW and a COP (coefficient of performance for cooling) of 0.37 can be achieved. It has provided a SCP (specific cooling power) of about 72 W/(kg adsorbent). Some field tests have been performed from July to October 2006 for providing air-conditioning and hot water. The efficiency of the collector field lies in 18.5–32.4%, with an average value of 27.3%. The daily average COP of the adsorption chiller lies in 33.8–49.7%, with an average COP of 40.3% and an average cooling power of 7.79 kW. A typical daily operation shows that the efficiency of the solar heating system, the adsorption cooling and the entirely solar cooling system is 28.4%, 45.2%, and 12.8%, respectively.  相似文献   

8.
This paper discusses solar power prospects in Wilayat Duqum in Oman. First, the geographic and topographic information about the selected region is presented. The methodology of producing solar radiation map for Duqum using GIS tools is then presented. The results obtained show very high potential of solar radiation over Wilayat Duqum during the whole year. A slope analysis has allowed calculating the yearly electricity generation potential for different concentrated solar power (CSP) technologies such as the parabolic trough, parabolic dish, tower, and concentrated PV. Based on the development plan of the Duqum region, and the topologies of the land areas in the region, it is suggested that, for the CSP technologies requiring large amount of water for washing the mirrors, the selected area is a flat land (slope < 1%) located proximity to the sea (~2 km) inside a total industrial area of around 50 km2, hence, allowing easy future expansion of the plant. It was proposed to start with a 100 MW power plant which is expected to consume about 2.4 km2 of flat land for the parabolic trough CSP technology. The total calculated potential of yearly electricity generation would be about 2.3 TWh. If half of the selected land (0.5 × 50 km2) is reserved for future expansion of the plant, the total future capacity can attain 1 GW of electric power. The selected area can also accommodate in the future different types of CSP technologies as they mature with time.  相似文献   

9.
A comprehensive improvement of the mathematical model for the so called transfer function method is presented in this study. This improved transfer function method can estimate the traditional solar collector parameters such as zero loss coefficient and heat loss coefficient. Two new collector parameters t and mfCf are obtained. t is a time scale parameter which can indicate the heat transfer ability of the solar collector. mfCf can be used to calculate the fluid volume content in the solar collector or to validate the regression process by comparing it to the physical fluid volume content if known. Experiments were carried out under dynamic test conditions and then test data were processed using multi-linear regression method to get collector parameters with statistic analysis. A comparison of the collector parameters obtained from the improved transfer function (ITF) method and the quasi-dynamic test (QDT) method is carried out. The results show that the improved transfer function method can accurately obtain reasonable collector parameters. The influence of different averaging time intervals is investigated. Based on the investigation it is recommended to use on line calculation if applicable for the second-order differential term with 6–9 min as the best averaging time interval. The measured and predicted collector power output of the solar collector are compared during a test of 13 days continuously both for the ITF method and the QDT method. The maximum and averaging error is 53.87 W/m2 and 5.22 W/m2 respectively of the ITF method while 64.13 W/m2 and 6.22 W/m2 of the QDT method. Scatter and relative error distribution of the measured power output versus the predicted power output is also plotted for the two methods. No matter in either error analysis or scatter distribution, the ITF method is more accurate than the QDT method in predicting the power output of a solar collector.In conclusion, all the results show that the improved transfer function method can accurately and robustly estimate solar collector parameters and predict solar collector thermal performance under dynamic test conditions.  相似文献   

10.
《Renewable Energy》2007,32(8):1259-1272
Parabolic collectors of commercial solar thermal power plants are subject to variable convection heat transfer from the receiver tube. In the present study heat transfer from a receiver tube of the parabolic trough collector of the 250 kW solar power plants in Shiraz, Iran, is studied taking into account the effects of variation of collector angel of attack, wind velocity and its distribution with respect to height from the ground.The governing equations for the two-dimensional steady state wind flow include continuity, momentum and energy equations and RNG-based kε model for turbulence scheme. Finite volume discretization method is used to solve the governing equations with wall function boundary condition and the SIMPLE approach is employed to iterate for the pressure correction and convergence of the velocity field. The momentum equation contains buoyancy force when the buoyancy effect is high and force convection effect is low.Computation is carried out for various wind velocities and different collector orientations with respect to wind direction. For solution of the energy equation, temperature of the receiver tube is taken as 350 K and ambient temperature is assumed to be 300 K. Various recirculation and temperature fields were observed around the receiver tube for different flow conditions. Effect of collector orientation on the average Nu number for the receiver tube was found negligible when the wind speed is low (Re⩽4.5×105 based on the collector aperture). But when the wind velocity is high (Re>4.5×105), the collector effect on the variation of Nu around the glass cover of the absorber tube is considerable.  相似文献   

11.
The optical efficacy of light emitting diode (LED) has exceeded 72 lm/W in 2006. This implies that energy can be saved about 75%, as compared to mercury lamps widely used in roadway lighting. In some remote areas where the grid power cannot reach, independent solar-powered lighting using high-power LED provides a promising solution. However, the cost of solar photovoltaic device may cause the application of solar-powered LED roadway lighting to be not economically feasible.The present study investigates the design of the solar-powered LED roadway lighting using high-power LED luminaire (100 W) and estimates the installation cost for a 10 km highway with 2 lanes. LED luminaries are installed on both side of the road with staggered arrangement. The pole distance is 30 m. The cost comparison of LED lighting using grid and solar power with the conventional mercury lamps was carried out. It shows that the installation cost is 22 million USD for LED powered by grid power and 26 million USD for solar-powered. The total installation cost of conventional mercury lighting is 18 million USD. The excess cost of LED mainly comes from the cost of LED lamp and solar PV. But, the cost of power generation and electrical transmission line can be greatly reduced since about 75% energy was saved for LED. This permits the use of smaller copper wire and shorter line length for solar-powered system which in turn saves installation cost. The payback time for the excess investment of LED is 2.2 years for LED using grid power and 3.3 years for LED using solar power.  相似文献   

12.
Selection of an appropriate HTF is important for minimising the cost of the solar receiver, thermal storage and heat exchangers, and for achieving high receiver and cycle efficiencies. Current molten salt HTFs have high melting points (142–240 °C) and degrade above 600 °C. Sodium’s low melting point (97.7 °C) and high boiling point (873 °C) allow for a much larger range of operational temperatures. Most importantly, the high temperatures of sodium allow the use of advanced cycles (e.g. combined Brayton/Rankine cycles). In this study, a comparison between the thermophysical properties of two heat transfer fluids (HTFs), Hitec (a ternary molten salt 53% KNO3 + 40% NaNO2 + 7% NaNO3) and liquid sodium (Na), has been carried out to determine their suitability for use in high-temperature concentrated solar thermal central-receiver systems for power generation. To do this, a simple receiver model was developed to determine the influences of the fluids’ characteristics on receiver design and efficiency. While liquid sodium shows potential for solar thermal power systems due to its wide range of operation temperatures, it also has two other important differences – a high heat transfer coefficient (~an order of magnitude greater than Hitec) and a low heat capacity (30–50% lower than Hitec salt). These issues are studied in depth in this model. Overall, we found that liquid sodium is potentially a very attractive alternative to molten salts in next generation solar thermal power generation if its limitations can be overcome.  相似文献   

13.
The performance of a parabolic trough collector (PTC)-based steam generation system depends significantly on the heat losses of the solar receiver. This paper presents an experimental study of the heat losses of a double glazing vacuum U-type solar receiver mounted in a PTC natural circulation system for generating medium-temperature steam. Field experiments were performed to determine the overall heat losses of the receiver. Effects of wind, vacuum glass tube, radiation, and structural characteristics on the heat losses were analyzed. The thermal efficiency of the receiver was found to be 0.791 and 0.472 in calm and windy days, respectively, at a test temperature of about 100 °C, whereas the thermal efficiencies became 0.792 and 0.663, respectively, while taking the receiver element into consideration. The heat losses were increased from 0.183 to 0.255 kW per receiver for the two cases tested. It was shown that neither convection nor radiation heat losses may be negligible in the analysis of such U-type solar receivers.  相似文献   

14.
W.T. Xie  Y.J. Dai  R.Z. Wang 《Solar Energy》2012,86(9):2458-2471
The efficiency and heat removal factors are useful parameters for evaluating the thermal performance of concentrating solar collectors. In this work, the efficiency factors and heat removal factors of Fresnel lens solar collectors using different kinds of point-focus cavity receivers were obtained both theoretically and experimentally. An experimental unit was built, whereby eight kinds of cavity receivers, namely: conical, spherical, cylindrical, hemispherical, positive cone frustum, reverse cone frustum, heteroconical and domical, were tested and analyzed. It is found that the theoretical results agree well with the test results. For the point-focus Fresnel lens solar collector, the conical cavity receiver showed the best thermal performance, with a highest theoretical heat removal factor of 0.868. Effect of conical cavity parameters on the efficiency and heat removal factors were studied. Results showed that under given operation conditions, the optimum aperture diameter of the cavity, the optimum inside diameter of the receiver tube and the optimum vertex angle of the cross section through the symmetric axis of the receiver are 80 mm, 15 mm and 60°, respectively. For better thermal performance, the geometrical concentration ratio of the studied Fresnel lens solar collector should be more than 500.  相似文献   

15.
A small combined cold and power (SCCP) system is presented. An experimental study of the performance of the SCCP system is described. The gas fuelled SCCP system uses a micro gas turbine generator set and an absorption chiller. The test facility designed and built is also described. The rated electricity power of the micro gas turbine generator is about 24.5 kW at the experimental conditions. When exhaust gas from the micro gas turbine is used to drive the absorption chiller, the rated cooling capacity is 52.7 kW without supplying fuel to burn in the absorption chiller and 136.2 kW with supplying about 78.9 kW LPG fuel to burn in the absorption chiller, respectively. Primary energy rate (PER) and comparative saving of primary energy demand are used to evaluate the performance of the SCCP system. PER of the SCCP system decreases rapidly with the decrease of electric power output when the electric power output is less than 10 kW. The calculated results also show that comparative saving of primary energy demand of the SCCP system decreases with the decrease of electric power output and the SCCP system do not save primary energy comparing to conventional energy system when the electric power output is less than 10 kW.  相似文献   

16.
Y.B. Tao  Y.L. He  Z.G. Qu 《Solar Energy》2012,86(5):1155-1163
Based on enthalpy method, numerical studies were performed for high temperature molten salt phase change thermal energy storage (PCTES) unit used in a dish solar thermal power generation system. Firstly, the effects of the heat transfer fluid (HTF) inlet temperature and velocity on the PCTES performance were examined. The results show that although increasing the HTF inlet velocity or temperature can enhance the melting rate of the phase change material (PCM) and improve the performance of the PCTES unit, the two parameters will restrict each other for the fixed solar collector heat output. Then three enhanced tubes were adopted to improve the PCTES performance, which are dimpled tube, cone-finned tube and helically-finned tube respectively. The effects of the enhanced tubes on the PCM melting rate, solid–liquid interface, TES capacity, TES efficiency and HTF outlet temperature were discussed. The results show that compared with the smooth tube, all of the three enhanced tubes could improve the PCM melting rate. At the same working conditions, the melting time is 437.92 min for the smooth tube, 350.75 min for dimpled tube which is reduced about 19.9% and 320.25 min for cone-finned tube which is reduced about 26.9% and 302.75 min for helically-finned tube reduced about 30.7%. As a conclusion, the thermal performance of PCTES unit can be effectively enhanced by using enhanced tube instead of smooth tube. Although, the HTF pressure drops for the enhanced tubes are also larger than that of the smooth tube, the largest pressure drop (1476.2 Pa) is still very lower compared with the working pressure (MPa magnitude) of the dish solar generation system. So, the pressure drops caused by the enhanced tubes could almost be neglected.  相似文献   

17.
18.
《Applied Thermal Engineering》2007,27(11-12):1978-1985
An experimental flat plate solar collector operating in conjunction with a closed-end oscillating heat pipe (CEOHP) offers a reasonably efficient and cost effective alternative to conventional solar collector system that use heat pipes. The CEOHP system described in this study relies on the natural forces of gravity and capillary action and dose not require an external power source. The flat plate collector consisted of a 1 mm thick sheet of black zinc covered by a glass enclosure with a collecting area of 2.00 × 0.97 m2 , an evaporator located on the collecting plate, and a condenser inserted into a water tank. A length of 0.003 ID copper tubing was bent into multiple turns at critical points along its path and used to channel the working fluid throughout the system. R134a was used as the working fluid. Efficiency evaluations were conducted during daylight hours over a two month period and included extensive monitoring and recording of temperatures with type-K thermocouples placed at key locations throughout the system. The results confirmed the anticipated fluctuation in collector efficiency dependant on the time of day, solar energy irradiation, ambient temperature and flat plate mean temperature. An efficiency of approximately 62% was achieved, which correlates with the efficiency of the more expensive heat pipe system. The CEOHP system offers the additional benefits of corrosion free operation and absence of freezing during winter months.  相似文献   

19.
The advantage of PV–thermal hybrid systems is their high total efficiency. By using concentrating hybrid systems, the cost per energy produced is reduced due to simultaneous heat and electricity production and a reduced PV cell area. In this article, the optical efficiency of a water-cooled PV–thermal hybrid system with low concentrating aluminium compound parabolic concentrators is discussed. The system was built in 1999 in Älvkarleby, Sweden (60.5° N, 17.4° E) with a geometric concentration ratio of C=4 and 0.5 kWp electric power. The yearly output is 250 kWh of electricity per square metre solar cell area and 800 kWh of heat at low temperatures per square metre solar cell area. By using numerical data from optical measurements of the components (glazing, reflectors, and PV cells) the optical efficiency, ηopt, of the PV–CPC system has been determined to be 0.71, which is in agreement with the optical efficiency as determined from thermal and electrical measurements. Calculations show that optimised antireflection-treated glazing and reflectors could further increase the electric power yield.  相似文献   

20.
Since the 80s power production with solar thermal power plants has been a way to substitute fossil fuels. By concentrating direct solar radiation from heliostats very high temperatures of a thermal fluid can be reached. The resulting heat is converted to mechanical energy in a steam cycle which generates electricity.High efficiencies and fast start-up are reached by using air as a heat medium, as well as using porous ceramic materials as solar receiver of the concentrated sunlight.In Germany the construction of a 1.5 MWe solar tower power plant began in 2008. It is operational since December 2008 and started production of electricity in the spring of 2009.In Greece and Cyprus, countries with high solar potential, the development of this competitive solar thermal technology is imperative, since it has already been implemented in other Mediterranean countries.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号