首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
A new, completely automated gas chromatography technique has been developed to separate the different gaseous compounds produced during underground coal gasification for their (13)C/(12)C and D/H isotope ratio measurements. The technique was designed for separation and collection of H(2), CO, CO(2), H(2)O, H(2)S, CH(4), and heavier hydrocarbons. These gaseous compounds are perfectly separated by the gas-phase chromatograph and quantitatively sent to seven combustion and collection lines. H(2), CO, CH(4), and heavier hydrocarbons are quantitatively oxidized to CO(2) and/or H(2)O. The isotopic analyses are performed by the sealed-tube method. The zinc method is used for reduction of both water and H(2)S to hydrogen for D/H analysis. Including all preparation steps, the reproducibility of isotope abundance values, for a quantity higher than or equal to 0.1 mL of individual components in a mixture (5 mL of gases being initially injected in the gas chromatograph), is ±0.1‰ for δ(13)C(PDB) and ±6‰ for δD(SMOW).  相似文献   

2.
A liquid-nitrogen-cooled CO laser and an intracavity resonant photoacoustic cell are employed to monitor trace gases. The setup was designed to monitor trace gas emissions of biological samples on line. The arrangement offers the possibility to measure gases at the 10(9) by volume (ppbv) level (e.g., CH(4), H(2) O) and to detect rapid changes in trace gas emission. A detection limit of 1 ppbv for CH(4) in N(2) equivalent to a minimal detectable absorption of 3 × 10(-9) cm(-1) can be achieved. Because of the kinetic cooling effect we lowered the detection limit for CH(4) in air is decreased to 10 ppbv. We used the instrument in a first application to measure the CH(4) and H(2) O emission of individual cockroaches and scarab beetles. These emissions could be correlated with CO(2) emissions that were recorded simultaneously with an infrared gas analyzer. Characteristic breathing patterns of the insects could be observed; unexpectedly methane was also found to be released.  相似文献   

3.
Atmospheric pressure ionization mass spectrometry (APIMS) is being routinely used to quantify trace impurities in bulk gases used in the manufacture of semiconductor devices. APIMS has been successfully applied for the quantification of ppt levels of O(2), H(2)O, CO(2), and CH(4) in Ar, N(2), and He. However, it has not been successfully used to quantify trace impurities in bulk O(2) due to the low ionization potential of O(2). APIMS relies on charge-transfer reaction between the ions of the bulk gas molecules and impurity molecules. Since all the relevant impurity molecules have ionization potentials higher than that of O(2), APIMS has not been used to analyze for impurities in O(2). We report here the detection of sub-ppb levels of H(2)O in O(2) by making use of the clustering reaction between O(2)(+) and H(2)O. The declustering region in an APIMS, which is normally used to break apart unwanted and interfering clusters, has to be carefully adjusted to keep intact the weakly bound cluster O(2)(+)·H(2)O. Our results indicate a statistical detection limit of less than 300 ppt for the detection of H(2)O in O(2).  相似文献   

4.
This paper presents the development of a static headspace capillary gas chromatographic method (HS-GC) for simultaneously determining dissolved gases (H2, O2, N2, CO, CO2, CH4, C2H6, C2H4, C2H2, C3H8) and moisture from a unique 15-mL mineral oil sample. A headspace sampler device is used to equilibrate the sample species in a two-phase system under controlled temperature and agitation conditions. A portion of the equilibrated species is then automatically split-injected into two chromatographic channels mounted on the same GC for their separation. The hydrocarbons and the lighter gases are separated on the first channel by a GS-Q column coupled with a MolSieve 5-A column via a bypass valve, while the moisture is separated on the second channel using a Stabilwax column. The analytes are detected by using two universal pulsed-discharge helium ionization detectors (PDHID). The performance of the method was established using equilibrated vials containing known amounts of gas mixture, water, and blank oil. The signal is linear over the concentration ranges normally found for samples collected from open-breathing power transformers. Determination sensitivity varies with the nature of the species considered with values as high as 21 500 A x 10(-9) s (microg/ g)(-1) for H2O, 46-216 A x 10(-9) s (microL/L)(-1) for the hydrocarbons and carbon oxides, and as low as 8-21 A x 10(-9) s (microL/L)(-1) for the O2 and N2 permanent gases. The detection limit of the method is between 0.08 and 6 microL/L for the dissolved gases, except for O2, N2, and CO2, where higher values are observed due to air intrusion during sampler operations, and 0.1 microg/g for the dissolved water. Ten consecutive measurements in the low and high levels of the calibration curves have shown a precision better than 12% and 6%, respectively, in all cases. A comparison study between the HS-GC method and the ASTM standard procedures on 31 field samples showed a very good agreement of the results. The advantages of configuring the arrangement with two PDHID over the conventional flame ionization and thermal conductivity detectors were clearly demonstrated.  相似文献   

5.
We have developed a new technique in which a solid reagent, cobalt(III) fluoride, is used to prepare oxygen gas for isotope ratio measurement from water derived either from direct injection or from the pyrolysis of solid samples. The technique uses continuous flow, isotope ratio monitoring, gas chromatography/mass spectrometry (irmGC/MS) to measure the delta18O and delta17O of the oxygen gas. Water from appropriate samples is evolved by a procedure of stepped pyrolysis (0-1000 degrees C, typically in 50 degrees C increments) under a flowing stream of helium carrier gas. The method has considerable advantages over others used for water analysis in that it is quick; requires only small samples, typically 1-50 mg of whole rock samples (corresponding to approximately 0.2 micromol of H2O); and the reagent is easy and safe to handle. Reproducibility in isotope ratio measurement obtained from pyrolysis of samples of a terrestrial solid standard are delta18O +/- 0.54, delta17O +/- 0.33, and delta17O +/- 0.10/1000, 1sigma in all cases. The technique was developed primarily for the analysis of meteorites, and the efficiency of the method is illustrated herein by results from water standards, solid reference materials, and a sample of the Murchison CM2 meteorite.  相似文献   

6.
Ultrasmooth nanostructured diamond (USND) films were synthesized on Ti-6Al-4V medical grade substrates by adding helium in H(2)/CH(4)/N(2) plasma and changing the N(2)/CH(4) gas flow from 0 to 0.6. We were able to deposit diamond films as smooth as 6 nm (root-mean-square), as measured by an atomic force microscopy (AFM) scan area of 2 μm(2). Grain size was 4-5 nm at 71% He in (H(2) + He) and N(2)/CH(4) gas flow ratio of 0.4 without deteriorating the hardness (~50-60 GPa). The characterization of the films was performed with AFM, scanning electron microscopy, x-ray diffraction (XRD), Raman spectroscopy, and nanoindentation techniques. XRD and Raman results showed the nanocrystalline nature of the diamond films. The plasma species during deposition were monitored by optical emission spectroscopy. With increasing N(2)/CH(4) feedgas ratio (CH(4) was fixed) in He/H(2)/CH(4)/N(2) plasma, a substantial increase of CN radical (normalized by Balmer H(α) line) was observed along with a drop in surface roughness up to a critical N(2)/CH(4) ratio of 0.4. The CN radical concentration in the plasma was thus correlated to the formation of ultrasmooth nanostructured diamond films.  相似文献   

7.
Davis WE  Li Y 《Analytical chemistry》2008,80(14):5449-5453
A new isotope dilution gas chromatography/chemical ionization/tandem mass spectrometric method was developed for the analysis of carcinogenic hydrazine in drinking water. The sample preparation was performed by using the optimized derivatization and multiple liquid-liquid extraction techniques. Using the direct aqueous-phase derivatization with acetone, hydrazine and isotopically labeled hydrazine-(15)N2 used as the surrogate standard formed acetone azine and acetone azine-(15)N2, respectively. These derivatives were then extracted with dichloromethane. Prior to analysis using methanol as the chemical ionization reagent gas, the extract was dried with anhydrous sodium sulfate, concentrated through evaporation, and then fortified with isotopically labeled N-nitrosodimethylamine-d6 used as the internal standard to quantify the extracted acetone azine-(15)N2. The extracted acetone azine was quantified against the extracted acetone azine-(15)N2. The isotope dilution standard calibration curve resulted in a linear regression correlation coefficient (R) of 0.999. The obtained method detection limit was 0.70 ng/L for hydrazine in reagent water samples, fortified at a concentration of 1.0 ng/L. For reagent water samples fortified at a concentration of 20.0 ng/L, the mean recoveries were 102% with a relative standard deviation of 13.7% for hydrazine and 106% with a relative standard deviation of 12.5% for hydrazine-(15)N2. Hydrazine at 0.5-2.6 ng/L was detected in 7 out of 13 chloraminated drinking water samples but was not detected in the rest of the chloraminated drinking water samples and the studied chlorinated drinking water sample.  相似文献   

8.
One of the key challenges in reforming military fuels for use with fuel cells is their high sulfur content, which can poison the fuel cell anodes. Sulfur-tolerant fuel reformers can convert this sulfur into H(2)S and then use a desulfurizing bed to remove it prior to the fuel cell. In order to optimize and verify this desulfurization process, a gas-phase sulfur analyzer is required to measure H(2)S at low concentrations (<1 ppm(v)) in the presence of other reforming gases (e.g., 25-30% H(2), 10-15% H(2)O, 15% CO, 5% CO(2), 35-40% N(2), and trace amounts of light hydrocarbons). In this work, we utilize near-infrared cavity-enhanced optical absorption spectroscopy (off-axis ICOS) to quantify H(2)S in a JP-8 fuel reformer product stream. The sensor provides rapid (2 s), highly precise (±0.1 ppm(v)) measurements of H(2)S in reformate gases over a wide dynamic range (0-1000 ppm(v)) with a low detection limit (3σ = ±0.09 ppm(v) in 1 s) and minimal cross-interferences from other present species. It simultaneously quantifies CO(2) (±0.2%), CH(4) (±150 ppm(v)), C(2)H(4) (±30 ppm(v)), and H(2)O (±300 ppm(v)) in the reformed gas for a better characterization of the fuel reforming process. Other potential applications of this technology include measurement of coal syngas and H(2)S in natural gas. By including additional near-infrared, distributive feedback diode lasers, the instrument can also be extended to other reformate species, including CO and H(2).  相似文献   

9.
High-quality nanometer thick ultramicroporous membranes were prepared from silica sol-gel processes and tested for the permeation of binary gas mixtures of He, H2, CO2, and CH4 across different temperature and partial pressure regimens. Pore size distribution by molecular probing showed that the majority of pore sizes had dimensions below 2.9 A. In 50:50 binary mixtures, the fluxes of gases increased as a function of temperature, indicating an activated transport mechanism. The ultramicroporous membranes showed high selectivities at 150 degrees C for He/CO2 (30), He/CH4 (93), H2/CO2 (10), and H2/CH4 (9) with lower selectivities for CO2/CH4 (5). High activation energies (Ea) were observed for the permeance of 50:50 binary mixtures containing He and H2 of 22.1-27.5 and 17.6-23.1 kJ.mol-1, respectively. The Ea for the permeance of the total mixture approached the Ea for the permeance of the molecule with the smaller kinetic diameter (He or H2).  相似文献   

10.
Laser ablation of FOX-7: proposed mechanism of decomposition   总被引:1,自引:0,他引:1  
A novel high-energy explosive material, FOX-7 (1,1-diamino-2,2-dinitroethylene), was studied using a combination of laser-induced breakdown spectroscopy (LIBS) and selected ion flow tube mass spectrometry (SIFT-MS). The LIBS technique uses short laser pulses (an ArF excimer laser) as the energy source to convert small quantities of a sample into plasma and to induce the emission of its molecular fragments or atoms. SIFT-MS is a novel method for absolute quantification based on chemical ionization using three reagent ions, with the ability to determine concentrations of trace gases and vapors of volatile organic compounds in real time. SIFT-MS was used to study the release of NO, NO(2), HCN, HONO, HCHO, CH(3)CH(2)OH, and C(2)H(2) after laser ablation of the explosive compound FOX-7 in solid crystalline form. The radiation emitted after excitation was analyzed using a time-resolved UV-vis spectrometer with an ICCD detector. The electronic bands of CN (388 nm), OH (308.4 nm), and NO (237.1 nm) radicals and the atomic lines of C, N, and H were identified.  相似文献   

11.
Lin JM  Yamada M 《Analytical chemistry》1999,71(9):1760-1766
The oxidation reaction between periodate and polyhydroxyl compounds was studied. A strong chemiluminescent (CL) emission was observed when the reaction took place in a strong alkaline solution without any special CL reagent. However, in acidic or neutral solution, it was hard to record the CL with our instrument. It was interesting to find that in the presence of carbonate the CL signal was enhanced significantly. When O(2) gas and N(2) gas were blown into the reagent solutions, both background and CL signals of the sample were enhanced by O(2) and decreased by N(2). The spectral distribution of the CL emission showed two main bands (λ = 436-446 and 471-478 nm). Based on the studies of the spectra of CL, fluorescence and UV-visible, a possible CL mechanism was proposed. In strongly alkaline solution, periodate reacts with the dissolved oxygen to produce superoxide radical ions. A microamount of singlet oxygen ((1)O(2)*) could be produced from the superoxide radicals. A part of the superoxide radicals acts on carbonates and/or bicarbonates leading to the generation of carbonate radicals. Recombination of carbonate radicals may generate excited triplet dimers of two CO(2) molecules ((CO(2))(2)*). Mixing of periodate with carbonate generated were very few (1)O(2)* and (CO(2))(2)*. These two emitters contribute to the CL background. The addition of polyhydroxyl compounds or H(2)O(2) caused enhancement of the CL signal. It may be due to the production of (1)O(2)* during the oxidized decomposition of the analytes in periodate solution. This reaction system has been established as a flow injection analysis for H(2)O(2), pyrogallol, and α-thioglycerol and their detection limits were 5 × 10(-)(9), 5 × 10(-)(9), and 1 × 10(-)(8) M, respectively. Considering the effective reaction ions, IO(4)(-), CO(3)(2)(-), and OH(-) could be immobilized on a strongly basic anion-exchange resin. A highly sensitive flow CL sensor for H(2)O(2), pyrogallol, and α-thioglycerol was also prepared.  相似文献   

12.
Field asymmetric waveform ion mobility spectrometry (FAIMS) has significant potential for post-ionization separations in conjunction with MS analyses. FAIMS fractionates ion mixtures by exploiting the fact that ion mobilities in gases depend on the electric field in a manner specific to each ion. Nearly all previous work has used pure gases, for which FAIMS fundamentals are understood reasonably well; however, unexpected phenomena observed in some gas mixtures (e.g., N(2)/CO(2)) but not in others (N(2)/O(2)) remain unexplained. Here, we introduce and experimentally test a universal model for FAIMS separations in mixtures, derived from formalisms that determine high-field mobilities in heteromolecular gases. Overall, the theoretical findings are consistent with data for N(2)/CO(2) (although quantitative discrepancies remain), while results for N(2)/O(2) fit Blanc's law, in agreement with measurements. Calculations for He/N(2) and He/CO(2) are also consistent with observations and suggest why adding He to the working gas generally enhances FAIMS performance. As predicted, mixtures of gases with extremely disparate molecular masses and collision cross sections, such as He/SF(6), exhibit spectacular non-Blanc effects, which greatly improve the resolution and peak capacity of technique. Understanding FAIMS operation in gas mixtures is expected to enable the rational design of media for both targeted and global analyses.  相似文献   

13.
Biological volatilization of selenium, Se, in a contaminated area is an economical and environmentally friendly approach to phytoremediation techniques, but analytical methods for monitoring and studying volatile compounds released in the process of phytovolatilization are currently limited in their performance. Thus, a new method for real time quantification of trace amounts of the vapors of hydrogen selenide (H(2)Se), methylselenol (CH(3)SeH), dimethylselenide ((CH(3))(2)Se), and dimethyldiselenide ((CH(3))(2)Se(2)) present in ambient air adjacent to living plants has been developed. This involves the characterization of the mechanism and kinetics of the reaction of H(3)O(+), NO(+), and O(2)(+?) reagent ions with molecules of these compounds and then use of the rate constants so obtained to determine their absolute concentrations in air by selected ion flow tube mass spectrometry, SIFT-MS. The results of experiments demonstrating this method on emissions from maize (Zea mays) seedlings cultivated in Se rich medium are also presented.  相似文献   

14.
The H3 factor, K, is a parameter required in high-precision, mass spectrometric analyses of hydrogen isotopic abundances. When H2 is used as the sample gas, R* = R - Ki2, where R* is the true HD/H2 ratio, R is the observed (mass 3)/(mass 2) ion-current ratio, and i2 is the ion current at mass 2. Four different methods for the determination of K were defined and tested under conditions characteristic of isotope ratio monitoring systems. Three of these were peak-based. The fourth employed steady flows of H2 from a conventional inlet system. Results obtained using the latter method were more precise (standard deviation of K = 0.1 versus approximately 0.6 ppm mV(-1) for the peak-based methods). However, use of the resulting values of K for correction of isotope ratio monitoring GC/MS results led to systematic errors as large as 9 per thousand, whereas use of the peak-based values led to no systematic errors. Values of K were only weakly dependent on the pressure of He, declining approximately 5% for each 10-fold increase in P(He). Small variations in partial pressures of H2O and CH4, potential contaminants under isotope ratio monitoring conditions, had no significant effect on values of K.  相似文献   

15.
GM592 DID型气相色谱仪是一款专门检测高纯气体的分析仪器,该仪器采用双柱气体切割转换分析方法,同时检测出高纯氩、高纯氮等气体中的氢气、氧气、氮气、甲烷、一氧化碳、二氧化碳等杂质的含量,其检测下限达到H2≤20×10-9,Ar/O2≤10×10-9,N2≤10×10-9,CH4≤10×10-9,CO≤20×10-9,CO2≤20×10-9,且色谱峰分离效果较好,分析结果准确度较高,但分析时间达到32 min,为了提高工作效率,缩短分析时间,对该仪器进行了改进,改进后分析时间缩短了8.5 min,经多次实验对照,使用效果较好。  相似文献   

16.
We report on the development and performance of a gas sensor based on a distributed feedback quantum cascade laser operating in continuous wave at room temperature for simultaneous measurement of nitrous oxide (N(2)O) and methane (CH(4)) concentrations at ground level. The concentrations of the gases are determined by a long path infrared diode laser absorption spectroscopy. The long-term stability of the instrument is evaluated using the Allan variance technique. A preliminary evaluation of the instrument performance is realized by in situ measurements of N(2)O and CH(4) concentrations at ground level during 1 day. The sensor has also been applied to study the time response of N(2)O concentrations to a fertilizer addition in a soil sample and for the comparison between various types of soils.  相似文献   

17.
Design and operation of a compact, portable, room-temperature mid-infrared gas sensor is reported. The sensor is based on continuous-wave difference-frequency generation (DFG) in bulk periodically poled lithium niobate at 4.6 mum, pumped by a solitary GaAlAs diode laser at 865 nm and a diode-pumped monolithic ring Nd:YAG laser at 1064.5 nm. The instrument was used for detection of CO in air at atmospheric pressure with 1 ppb precision (parts in 10(9), by mole fraction) and 0.6% accuracy for a signal averaging time of 10 s. It employed a compact multipass absorption cell with a 18-m path length and a thermoelectrically cooled HgCdTe detector. Precision was limited by residual interference fringes arising from scattering in the multipass cell. This is the first demonstration of a portable high-precision gas sensor based on diode-pumped DFG at room temperature. The use of an external-cavity diode laser can provide a tuning range of 700 cm(-1) and allow the detection of several trace gases, including N(2) O, CO(2), SO(2), H(2) CO, and CH(4).  相似文献   

18.
High-resolution absorption spectra of gas-phase monomethylamine (MMA, CH(3)NH(2)) and dimethylamine [DMA, (CH(3))(2)NH] in the region of the first overtone of the NH stretch vibration are reported. Measurements were performed with a near-infrared laser spectrometer based on the cavity-ringdown (CRD) detection technique. The minimum detectable absorption coefficient for the CRD detection setup is alpha(min)=1.55 x 10(-8) cm(-1) (for SNR = 1). This corresponds to detection limits of 350 parts in 10(9) (ppb) for MMA and 1.6 parts in 10(6) (ppm) for DMA in synthetic gas mixtures under interference-free conditions, or 10 ppm and 60 ppm for MMA and DMA, respectively, in the case of gas mixtures such as exhaled human breath containing H(2)O, CO(2), and other absorbing gases in this range.  相似文献   

19.
Two-photon laser-induced fluorescence (TP-LIF) line imaging of atomic hydrogen was investigated in a series of premixed CH4/O2/N2, H2/O2, and H2/O2/N2 flames using excitation with either picosecond or nanosecond pulsed lasers operating at 205 nm. Radial TP-LIF profiles were measured for a range of pulse fluences to determine the maximum interference-free signal levels and the corresponding picosecond and nanosecond laser fluences in each of 12 flames. For an interference-free measurement, the shape of the TP-LIF profile is independent of laser fluence. For larger fluences, distortions in the profile are attributed to photodissociation of H2O, CH3, and/or other combustion intermediates, and stimulated emission. In comparison with the nanosecond laser, excitation with the picosecond laser can effectively reduce the photolytic interference and produces approximately an order of magnitude larger interference-free signal in CH4/O2/N2 flames with equivalence ratios in the range of 0.5< or =Phi< or =1.4, and in H2/O2 flames with 0.3< or =Phi< or =1.2. Although photolytic interference limits the nanosecond laser fluence in all flames, stimulated emission, occurring between the laser-excited level, H(n=3), and H(n=2), is the limiting factor for picosecond excitation in the flames with the highest H atom concentration. Nanosecond excitation is advantageous in the richest (Phi=1.64) CH4/O2/N2 flame and in H2/O2/N2 flames. The optimal excitation pulse width for interference-free H atom detection depends on the relative concentrations of hydrogen atoms and photolytic precursors, the flame temperature, and the laser path length within the flame.  相似文献   

20.
Fourier transform infrared spectroscopy is an efficient technique for the detection and quantification of molecules in gas mixtures. Measurement results from a mobile laboratory for ambient air analysis and for remote sensing of plume emission with the commercially available K300 spectrometer are reported. CO, CO(2), NO, NO(2), N(2)O, NH(3), CH(4), SO(2), H(2)O, HCl, and HCHO concentrations have been determined with good agreement with in situ results. The on-line multicomponent analysis software is based on line-by-line retrieval and least-squares fitting procedures, including the effects of multiple aerosol scattering and cloud and rain influences.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号