首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Proton exchange membrane fuel cell (PEMFC) gas diffusion layers (GDLs) play important parts in diffusing gas, discharging liquid water, and conducting electricity, etc. When liquid water is discharged through GDL to gas channel, there will be some pores of GDLs occupied by liquid water. In this study, based on a one-dimensional model, the distribution of liquid water phase saturation is analyzed for different GDL structures including GDL with uniform porosity, GDL with sudden change porosity (GDL with microporous layer (MPL)) and GDL with gradient porosity distribution. The effect on gas diffusion of the changes of porosity and liquid saturation due to water remaining in GDL pores is calculated. The conclusions are that for uniform porosity GDL, the gas diffusion increases with the increase of porosity and contact angle and increases with the decrease of the thickness of GDL; for GDL with MPL, the larger the MPL porosity and the thinner the MPL thickness are, the stronger the gas diffusion is; for gradient change porosity GDL with the same average equivalent porosity, the larger the porosity gradient is, the more easily the gas diffuses. The optimization for GDL gradient structure shows that the GDL with a linear porosity distribution of 0.4x+0.40.4x+0.4 is the best of the computed cases.  相似文献   

2.
In this work, advanced x-ray radiographic techniques available at the Canadian Light Source (CLS) were utilized to study water droplet dynamics in a serpentine flow channel mimicking a proton exchange membrane fuel cell (PEMFC). High spatial and temporal resolution coupled with high energy photons of an x-ray beam provided high-resolution images of water droplets. This technique solved the problem caused by the opaqueness of fuel cell materials including the gas diffusion layer by providing a unique way to study water droplet dynamics at different operating conditions. From the captured images, droplet emergence and formation on porous gas diffusion layers (GDLs) were analyzed. Three commercially available GDLs (Sigracet AA, Sigracet BA, and Sigracet BC) were used and droplet detachment height was found to decrease in the following order AA < BA < BC under the same flow condition. Increasing the superficial gas velocity was found to decrease the droplet detachment height for all GDLs tested. Average droplet cycle for various operating conditions was obtained. It was found that humidified air did not show a difference in droplet dimensions at detachment compared to dry air used at the inlet gas. However, it did show an impact on droplet cycle time, which might be due to condensation.  相似文献   

3.
Synchrotron X-ray micro-computed tomography (X-ray μCT) is employed to measure the volume variation of gas diffusion layer (GDL) of a polymer electrolyte fuel cell (PEFC). In the present study, 3D structures are reconstructed by merging orthogonal-plane images. Using the 3D reconstruction, the variation of structural parameters such as the porosity in GDL is investigated under freeze-thaw cycles. The freez-thaw cycles are established using cryo system and light source, respectively. As a result, a structural transformation is observed at the interface between GDL and micro porous layer (MPL). In addition, the porosity is critically changed with irreversible transition under freeze-thaw cycles.  相似文献   

4.
In order to investigate the effect of capillary pressure on the transport of liquid water in the cathode gas diffusion layer (GDL) of a polymer electrolyte fuel cell, a one-dimensional steady-state mathematical model was developed, including the effect of temperature on the capillary pressure. Numerical results indicate that the liquid water saturation significantly increases with increases in the operating temperature of the fuel cell. An elevated operating temperature has an undesirable influence on the removal of liquid water inside the GDL. A reported peculiar phenomenon in which the flooding of the fuel cell under a high operating temperature and an over-saturated environment is more serious in a GDL combined with a micro-porous layer (MPL) than in a GDL without an MPL [Lim and Wang, Electrochim. Acta 49 (2004), 4149–4156] is explained based on the present analysis.  相似文献   

5.
The effects of gas diffusion layer’s (GDL’s) anisotropic bending stiffness on the electrochemical performances of polymer electrolyte membrane fuel cells have been investigated for carbon fiber-felt and -paper GDLs. The bending stiffness values of all GDLs in the machine direction are higher than those in the cross-machine direction. We have prepared GDL sheet samples such that the machine direction of GDL roll is aligned with the major flow field direction of a metallic bipolar plate at angles of 0° (parallel: ‘0° GDL’) and 90° (perpendicular: ‘90° GDL’). The I–V performances of all the 5-cell stacks with 90° GDLs are higher than those with 0° GDLs. All the 5-cell stacks with 90° GDLs show lower values of high-frequency resistance (HFR) than those with 0° GDLs. However, the gas pressure differences at both anode and cathode of 5-cell stacks with 90° GDLs appear to be similar to or slightly lower than those with 0° GDLs, making the lower HFR as a dominant factor for the improved I–V performances. This may result from the reduced intrusion of 90° GDLs into gas channels than 0° GDLs as observed by less thickness reduction under compression of 90° GDLs. A 45° GDL (skew alignment) also shows better performances than the 0° GDL.  相似文献   

6.
A three-dimensional, two-phase, non-isothermal model has been developed to explore the interaction between heat and water transport in proton exchange membrane fuel cells (PEMFCs). Water condensate produced from the electrochemical reaction may accumulate in the open pores of the gas diffusion layer (GDL) and retard the oxygen transport to the catalyst sites. This study predicts the enhancement of the water transport for linear porosity gradient in the cathode GDL of a PEMFC. An optimal porosity distribution was found based on a parametric study. Results show that a optimal linear porosity gradient with ?1 = 0.7 and ?2 = 0.3 for the parallel and z-serpentine channel design leads to a maximum increase in the limiting current density from 10,696 Am−2 to 13,136 Am−2 and 14,053 Am−2 to 16,616 Am−2 at 0.49 V, respectively. On the other hand, the oxygen usage also increases from 36% to 46% for the parallel channel design and from 55% to 67% for the z-serpentine channel design. The formation of a porosity gradient in the GDL enhances the capillary diffusivity, increases the electrical conductivity, and hence, benefits the oxygen transport throughout the GDL. The present study provides a theoretical support for existing reports that a GDL with a gradient porosity improves cell performance.  相似文献   

7.
The gas diffusion layer (GDL) is important for maintaining the performance of polymer electrolyte membrane (PEM) fuel cells, as its main function is to provide the cells with a path for fuel and water. In this study, the mechanical degradation process of the GDL was investigated using a leaching test to observe the effect of water dissolution. The amount of GDL degradation was measured using various methods, such as static contact angle measurements and scanning electron microscopy. After 2000 h of testing, the GDL showed structural damage and a loss of hydrophobicity. The carbon-paper-type GDL showed weaker characteristics than the carbon-felt-type GDL after dissolution because of the structural differences, and the fuel cell performance of the leached GDL showed a greater voltage drop than that of the fresh GDL. Contrary to what is generally believed, the hydrophobicity loss of GDL was not caused by the decomposition of polytetrafluoroethylene (PTFE).  相似文献   

8.
Water management in cathode gas diffusion electrode (GDE) of polymer electrolyte fuel cell (PEFC) is essential for high performance operation, because liquid water condensed in porous gas diffusion layer (GDL) and catalyst layer (CL) blocks oxygen transport to active reaction sites. In this study, the average liquid water content inside the cathode GDE of a low-temperature PEFC is experimentally and quantitatively estimated by the weight measurement, and the relationship between the water accumulation rate in the cathode GDE and the cell voltage is investigated. The liquid water behavior at the cathode is also visualized using an optical diagnostic, and the effects of operating conditions and GDL structures on the water transport in the cathode GDE are discussed. It is found that the liquid water content in the cathode GDE increases remarkably after starting the fuel cell operation due to the water production at the CL. At a high current density, the cell voltage drops suddenly after starting the operation in spite of a low water content in the cathode GDE. When the GDL thickness is increased, much water accumulates near the cathode CL and the fuel cell shuts down immediately after the operation. In the final section of this paper, the structure of cathode GDL that has several grooves for water removal is proposed to prevent water flooding and improve fuel cell performance. This groove structure is effective to promote the removal of the liquid water accumulated near the active catalyst sites.  相似文献   

9.
The influence of microporous layer (MPL) design parameters for gas diffusion layers (GDLs) on the performance of polymer electrolyte fuel cells (PEFCs) was clarified. Appropriate MPL design parameters vary depending on the humidification of the supplied gas. Under low humidification, decreasing both the MPL pore diameter and the content of polytetrafluoroethylene (PTFE) in the MPL is effective to prevent drying-up of the membrane electrode assembly (MEA) and enhance PEFC performance. Increasing the MPL thickness is also effective for maintaining the humidity of the MEA. However, when the MPL thickness becomes too large, oxygen transport to the electrode through the MPL is reduced, which lowers PEFC performance. Under high humidification, decreasing the MPL mean flow pore diameter to 3 μm is effective for the prevention of flooding and enhancement of PEFC performance. However, when the pore diameter becomes too small, the PEFC performance tends to decrease. Both reduction of the MPL thickness penetrated into the substrate and increase in the PTFE content to 20 mass% enhance the ability of the MPL to prevent flooding.  相似文献   

10.
For hydrogen-based polymer electrolyte fuel cells (PEFCs), water transport control in gas diffusion layers (GDLs) by wettability distribution is useful to suppress the flooding problem. In this study, the water transport of a novel GDL with hydrophilic-hydrophobic patterns was investigated. First, we clarified that the water motion in the hydrophilic GDL with microstructures could be reproduced by the enlarged scale model. The scale model experiment also showed that the same water behavior in hydrophilic GDL can be obtained from Capillary numbers (Ca) in a range of Ca ~ 10?5 to 10?3. As the computational load is inversely proportional to Ca, the computational load could be reduced by 1/100th by using Ca ~ 10?3, which is 100 times higher than PEFC operation (Ca ~ 10?5). Finally, the simulation with Ca ~ 10?3 was performed, and we showed that the GDL with straight region of contact angle 50° minimized the water accumulation.  相似文献   

11.
Generally, the GDL of a PEM fuel cell experiences three external attacks: dissolution of water, erosion of gas flow, and corrosion of electric potential. Of these degradation factors, this study focuses on the carbon corrosion of electric potential and investigates its impact through the accelerated carbon corrosion test. This study confirms that carbon corrosion occurs at the GDL, which decreases the operating fuel cell’s performance. To discover the effects of carbon corrosion, the GDL property changes are measured through various devices, including a scanning electron microscopy, a thermo gravimetric analyzer, and a tensile stress test. Carbon corrosion causes not only loss of weight and thickness but also degradation of mechanical strength in the GDL. In addition, the GDL shows serious damage in its center.  相似文献   

12.
The lattice Boltzmann method is used to simulate the three-dimensional dynamic process of liquid water breaking through the gas diffusion layer (GDL) in the polymer electrolyte membrane fuel cell. An accurate method is introduced to analyze asymmetric droplet shape. Ten micro-structures of Toray GDL were built based on a stochastic geometry model. It was found that asymmetric droplets are produced on the GDL surfaces. Their local apparent contact angles vary with different view angles and geometries. They are different to the idealized contact angles by symmetric simplification. It was concluded that the apparent contact angles are influenced by GDL structures and view angles. This information can help to bridge the gap between mesoscale and cell-scale simulations in the field of fuel cell simulation.  相似文献   

13.
This work explores how the degradation of the gas diffusion layer (GDL) under compression contributes to the formation of preferential pathways for water transport. Fluorescence microscopy is used to provide ex situ visualization of liquid water transport through the GDL placed beneath an optically transparent clamping plate. Transient image data obtained with a CCD camera indicates that areas of compression in the GDL coincide with preferential pathways for water transport and break-through. Preferential flow of water through the smaller pores resulting from GDL compression is contrary to the expected behaviour in a hydrophobic medium, and this suggests a loss of hydrophobicity. Scanning electron microscopy (SEM) is used to investigate the effect of compression on the morphology of the GDL. These SEM images show that compressing the GDL causes the breakup of fibers and, indeed, deterioration of the hydrophobic coating.  相似文献   

14.
The effects of gas diffusion layer’s (GDL’s) anisotropic bending stiffness on the degradation behavior of polymer electrolyte membrane fuel cells have been investigated under freezing conditions. We have prepared GDL sheet samples such that the higher stiffness direction of GDL roll is aligned with the major flow field direction of a metallic bipolar plate at angles of 0° (parallel: ‘0° GDL’) and 90° (perpendicular: ‘90° GDL’). The I-V performances before and after 1000 temperature cycles between −10 and 1 °C of 90° GDL stack are higher than those of 0° GDL stack, and the voltages of 90° GDL stack are decreased slower than those of 0° GDL stack, indicating a higher durability of 90° GDL stack. Furthermore, the values and increasing rates of high-frequency resistance of 90° GDL stack are lower than those of 0° GDL stack. However, the H2 and air pressure differences before and after 1000 temperature cycles of 90° GDL stack are very similar to those of 0° GDL stack. The surface of anode catalyst layer (CL) of membrane-electrode assembly (MEA) with catalyst-coated membrane type in 0° GDL stack appears to be more severely damaged than that in 90° GDL stack, especially under the channels, whereas the surfaces of cathode CLs of MEAs in both 0° and 90° GDL stacks are slightly damaged after 1000 temperature cycles.  相似文献   

15.
A mathematical model is developed to investigate the influence of porosity configurations in the gas diffusion layer (GDL) of the cathode on the electrochemical performance characteristics of a 3-D high-temperature proton exchange membrane (PEM) fuel cell. Four different non-uniform porosity configurations are defined through step functions and analyzed with uniform porosity case. The results are presented in terms of the cell performance characteristics viz. Current density, power density, vorticity magnitude, oxygen molar concentration, overpotential, and total power dissipation density. Our study reveals that oxygen molar concentration, current density, power density are found to be maximum when the stepwise porosity in GDL decreases in the streamwise direction. However, these parameters observed to be the least when the stepwise porosity in GDL increases along the streamwise direction. Additionally, the highest total power dissipation density is observed when the porosity in GDL varies across cross-stream wise direction among other configurations considered. However, it is found to be the least when porosity varies in a streamwise direction. The overpotential becomes the least when stepwise porosity decreases in the streamwise direction although the same is found to be maximum when the porosity in GDL increases along the streamwise direction. The performance is found to be optimal when porosity is maximum at cathode gas channel inlet and GDL-cathode gas channel interface.  相似文献   

16.
The transport of liquid water through an idealized 2-D reconstructed gas diffusion layer (GDL) of a polymer electrolyte membrane (PEM) fuel cell is computed subject to hydrophobic boundary condition at the fibre–fluid interface. The effect of air flow, as would occur in parallel/serpentine/interdigitated type of flow fields, on the liquid water transport through the GDL, ejection into the channel in the form of water droplets and subsequent removal of the droplets has been simulated. Results show that typically water flow through the fibrous GDL occurs through a fingering and channelling type of mechanism. The presence of cross-flow of air has an effect both on the path created within the GDL and on the ejection of water into the channel in the form of droplets. A faster rate of liquid water evacuation through the GDL (i.e., more frequent ejection of water droplets) as well as less flooding of the void space results from the presence of cross-flow. These results agree qualitatively with experimental observations reported in the literature.  相似文献   

17.
The presence of liquid water in a polymer electrolyte membrane fuel cell hinders gas diffusion to the active sites, which results in large concentration overpotentials and instability of the fuel cell performance. In this paper, a new customized gas diffusion layer (GDL) is presented that enhances liquid water transport from the electrode to the gas channels and therefore lowers mass transport losses of oxygen through the porous media. The GDL is systematically modified by laser-perforation with respect to the flow field design. The holes are characterized by SEM images. The performance of the laser-treated GDL was investigated in a small test fuel cell with a reference electrode by voltammetry and chronoamperometry measurements and compared to corresponding data with a non-modified GDL. Voltammetry experiments with different humidification levels of the inlet gases were conducted. In all cases, the cathode overpotential with the perforated GDL clearly shows reduced saturation which can be seen in a lower overpotential in the region limited by mass transport resulting in a higher limiting current density. The investigated current response of the chronoamperometry measurements clearly shows a better dynamic and overall performance of the test cell with the perforated GDL.  相似文献   

18.
Using the multiphase lattice Boltzmann method (LBM), the liquid water transport dynamics is simulated in a gas diffusion layer (GDL) of polymer electrolyte membrane fuel cells (PEMFCs). The effect of rib structure on the water invasion process in the micro-porous GDL is explored by comparing the two cases, i.e., with rib and without rib structures. The liquid water distribution and water saturation profile are presented to determine the wetting mechanism in the GDL. The results show that the liquid water transport in the GDL is strongly governed by capillary force and the rib structure plays a significant role on water distribution and water transport behavior in the GDL. Comparison of two cases confirms that the rib structure influences on the location of water breakthrough. The liquid water distribution and water saturation profile indicate that the high resistance force underneath the rib suppresses the growth of water cluster, resulting in the change of flow path. After water breakthrough, the liquid water distribution under the channel has little variation, whereas that under the rib continues to change. The predicted value of effective permeability is in good agreement with Carman-Kozeny correlation and experimental results in the literature. The results suggest that the LBM approach is an effective tool to investigate the water transport behavior in the GDL.  相似文献   

19.
The clamping pressure of polymer electrolyte membrane fuel cells for vehicle applications should be typically high enough to minimize contact resistance. However, an excessive compression pressure may cause a durability problem. In this study, the effects of gas diffusion layer (GDL) structure on the open circuit voltage (OCV) and hydrogen crossover have been closely examined. Results show that the performances of fuel cells with GDL-1 (a carbon fiber felt substrate with MPL having rough surface) and GDL-3 (a carbon fiber paper substrate with MPL having smooth surface) are higher than that with GDL-2 (a carbon fiber felt substrate with MPL having smooth surface) under low clamping torque conditions, whereas when clamping torque is high, the GDL-1 sample shows the largest decrease in cell performance. Hydrogen crossover for all GDL samples increases with the increase of clamping torque, especially the degree of increase of GDL-1 is much greater than that of the other two GDL samples. The OCV reduction of GDL-1 is much greater than that of GDL-2 and GDL-3. It is concluded that the GDL-3 is better than the other two GDLs in terms of fuel cell durability, because the GDL-3 shows the minimum OCV reduction.  相似文献   

20.
Water transport through gas diffusion layer of proton exchange membrane fuels cells is investigated experimentally. A filtration cell is designed and the permeation threshold and the apparent water permeability of several carbon papers are investigated. Similar carbon paper with different thicknesses and different Teflon loadings are tested to study the effects of geometrical and surface properties on the water transport. Permeation threshold increases with both GDL thickness and Teflon loading. In addition, a hysteresis effect exists in GDLs and the permeation threshold reduces as the samples are retested. Moreover, several compressed GDLs are tested and the results show that compression does not affect the breakthrough pressure significantly. The measured values of apparent permeability indicate that the majority of pores in GDLs are not filled with water and the reactant access to the catalyst layer is not hindered.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号