首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Adenosine myocardial perfusion single-photon emission computed tomography (SPECT) is now increasingly used for risk stratification of patients with known or suspected coronary artery disease. However, the incremental prognostic value of this test over clinical and historical information in a large series of women has not been examined. Thus, we studied 923 consecutive women who underwent adenosine technetium (Tc)-99m sestamibi myocardial perfusion SPECT and were followed-up for a mean period of 26+/-8 months. During the follow-up period, 77 hard events (46 cardiac deaths and 31 nonfatal myocardial infarctions) occurred. The results of the perfusion scan significantly risk stratified the population; patients with normal scans had a low rate of nonfatal myocardial infarction and cardiac death (< 1%/year of follow up). Patients with mildly abnormal scans had low cardiac death rates (0.9%/year of follow up); these rates increased as a function of scan abnormality (4.1% and 7.5% mortality per year of follow up in moderate and severely abnormal scans). Cox proportional hazards analysis demonstrated that after adjusting for prior myocardial infarction and diabetes mellitus (the most predictive individual clinical variables [global chi-square=22.5, p <0.001]), as well as heart rate at rest (the most predictive physiologic variable [chi-square=3.8; p=0.05]), the most predictive nuclear variable (summed stress score [chi-square=48.5; p <0.0001]) added significant incremental prognostic information (global chi-square increased from 22.5 to 56.2 [p <0.0001]). In conclusion, adenosine myocardial perfusion SPECT added significant incremental prognostic information to clinical and physiologic variables in women. Normal scans were associated with an excellent prognosis. In contrast, patients with moderately to severely abnormal scans were at a higher risk for future cardiac events.  相似文献   

2.
This blinded, single center study prospectively compares exercise electron beam computed tomography (EBCT) with stress technetium-99m (Tc-99m) sestamibi single-photon emission computed tomography (SPECT) in 33 patients undergoing coronary angiography for evaluation of chest pain. Patients undergoing routine cardiac catheterization for the diagnosis of chest pain were imaged at rest using EBCT. Patients exercised on a semi-supine ergometer, and exercise EBCT was immediately followed by injection of Tc-99m sestamibi for assessment of myocardial ischemia. At peak exercise, Tc-99m SPECT, followed immediately by nonionic contrast material, was injected intravenously to directly compare these 2 imaging techniques. Patients were reimaged with Tc-99m SPECT at rest 24 to 48 hours after stress. Exercise EBCT, which was analyzed using a global ejection fraction measure, had a sensitivity of 81% and a specificity of 76%, compared with angiography. Using the development of a new regional wall motion abnormality as evidence of obstructive coronary artery disease (CAD), EBCT yielded a specificity of 100% and a sensitivity of 88%. Reversible perfusion defects identified by SPECT, as evidence of obstructive CAD, revealed a sensitivity of 75% and a specificity of 71%. The specificity of regional wall motion analysis by EBCT was significantly better than SPECT (p <0.01) in this population. This study demonstrates regional wall motion assessed by EBCT to be as sensitive and more specific than SPECT myocardial perfusion imaging in identifying obstructive CAD as defined by angiography.  相似文献   

3.
BACKGROUND: Shortening the acquisition time for myocardial single-photon emission computed tomographic (SPECT) imaging increases patient comfort and laboratory throughput. The purpose of this study was to compare the diagnostic accuracy for coronary artery disease detection of myocardial SPECT images acquired in 5 to 10 minutes versus 25 minutes using Tc-99m methoxyisobutylisonitrile (Tc-99m sestamibi) and a single-head gamma camera. METHODS AND RESULTS: Forty-one subjects had a standard 1-day rest/stress Tc-99m sestamibi myocardial SPECT study. Two sets of rest and stress images were acquired on the same day for each subject. One set of images was acquired with a 5- to 10-minute fast acquisition protocol; the second set of images was acquired with a 25-minute standard protocol. The accuracies of the fast and standard protocols for identifying individuals with and without coronary artery disease were equivalent. Accuracy was 76% for the fast protocol and 73% for the standard protocol in individuals with at least one coronary stenosis > or = 70%. The accuracies of the two protocols for identifying individual coronary arteries with stenoses > or = 70% also were equivalent. Accuracy was 77% for the fast protocol and 74% for the standard protocol. CONCLUSIONS: SPECT myocardial images may be acquired in as little as 5 to 10 minutes using Tc-99m sestamibi and a 1-day rest/stress protocol. Accuracy is equivalent to that attained in studies with longer imaging times.  相似文献   

4.
In order to quantitatively assess the extent and severity of myocardial ischemia by Tc-99m sestamibi exercise myocardial scintigraphy, we developed a new method of change rate (CR) mapping and examined its efficiency. CR was calculated to divide the counts per pixel in the stress polar map by that in the rest polar map at each corresponding pixel. The CR map showed the CR values at each pixel. To correct the differences between the stress and rest images for the dose of Tc-99m sestamibi administered, the mean counts per pixel in the stress polar map and the rest map were adjusted to the same level. Regarding the regions in which the CR value was less than 1 as ischemia, we compared the abilities of the CR map and the polar map to detect coronary artery stenosis in 5 patients with angina pectoris. The sensitivity for coronary artery stenosis was 80% in the CR map, and 40% in the polar map. The specificity for both was 75%. We concluded that the CR map was effective in assessing the extent and severity of myocardial ischemia in Tc-99m sestamibi exercise myocardial scintigraphy.  相似文献   

5.
CONTEXT: Cardiac imaging has advanced rapidly, providing clinicians with several choices for evaluating patients with suspected coronary artery disease, but few studies compare modalities directly. OBJECTIVES: To review the contemporary literature and to compare the diagnostic performance of exercise echocardiography (ECHO) and exercise single-photon emission computed tomography (SPECT) imaging in the diagnosis of coronary artery disease. DATA SOURCES: Studies published between January 1990 and October 1997 identified from MEDLINE search; bibliographies of reviews and original articles; and suggestions from experts in each area. STUDY SELECTION: Articles were included if they discussed exercise ECHO and/or exercise SPECT imaging with thallous chloride TI 201 (thallium) or technetium Tc 99m sestamibi for detection and/or evaluation of coronary artery disease, if data on coronary angiography were presented as the reference test, and if the absolute numbers of true-positive, false-negative, true-negative, and false-positive observations were available or derivable from the data presented. Studies performed exclusively in patients after myocardial infarction, after percutaneous transluminal coronary angioplasty, after coronary artery bypass grafting, or with recent unstable coronary syndromes were excluded. DATA EXTRACTION: Clinical variables, technical factors, and test performance were independently extracted by 2 reviewers on a standardized spreadsheet. Discrepancies were resolved by consensus. RESULTS: Forty-four articles met inclusion criteria. In pooled data weighted by the sample size of each study, exercise ECHO had a sensitivity of 85% (95% confidence interval [CI], 83%-87%) with a specificity of 77% (95% CI, 74%-80%). Exercise SPECT yielded a similar sensitivity of 87% (95% CI, 86%-88%) but a lower specificity of 64% (95% CI, 60%-68%). In a summary receiver operating characteristic model comparing exercise ECHO performance to exercise SPECT, exercise ECHO was associated with significantly better discriminatory power (parameter estimate, 1.18; 95% CI, 0.71-1.65), when adjusted for age, publication year, and a setting including known coronary artery disease for SPECT studies. In models comparing the discriminatory abilities of exercise ECHO and exercise SPECT vs exercise testing without imaging, both ECHO and SPECT performed significantly better than exercise testing. The incremental improvement in performance was greater for ECHO (3.43; 95% CI, 2.74-4.11) than for SPECT (1.49; 95% CI, 0.91-2.08). CONCLUSIONS: Exercise ECHO and exercise SPECT have similar sensitivities for the detection of coronary artery disease, but exercise ECHO has better specificity and, therefore, higher overall discriminatory capabilities as used in contemporary practice.  相似文献   

6.
Myocardial scintigraphy was performed three times in a 55-year-old woman with left bundle branch block (LBBB). A significant LAD stenosis had been excluded by coronary angiography. The first scintigraphy was performed with Tc-99m sestamibi after submaximal bicycle exercise and revealed a septal perfusion deficit. This deficit could not be reproduced in the following examinations after pharmacological stress testing with dipyridamole using both Tl-201 and Tc-99m sestamibi. Perfusion at rest assessed with Tl-201 was normal in all studies. It is concluded that pharmacological stress testing with dipyridamole is to be preferred in patients with LBBB. With respect to the accuracy of myocardial perfusion imaging the choice of the radiopharmaceutical plays a less important role.  相似文献   

7.
We examined 1,159 consecutive patients who underwent adenosine stress dual isotope single-photon emission computed tomography (SPECT) and had follow-up performed at a mean of 27.5 +/- 9.1 months (94% complete) for hard events (cardiac death and myocardial infarction) and referral to cardiac catheterization after nuclear testing. During follow-up, 120 hard events occurred (11.0% hard event rate; 72 cardiac deaths [6.7% cardiac death rate] and 57 myocardial infarctions [5.3% myocardial infarction rate]). Cox proportional hazards analysis revealed that nuclear testing added incremental value after adjusting for clinical and historical variables (global chi-square increased 13 to 98 for cardiac death as the end point, global chi-square increased 19 to 105 for hard events as the end point; p <0.0001 for both). Kaplan-Meier analysis demonstrated that after clinical risk stratification of the patient population, the results of nuclear testing were further able to significantly stratify both low- and intermediate- to high-risk patients. Patients with both normal and mildly abnormal scans were at low risk of cardiac death (<1% cardiac death per year of follow-up) and the risk of events increased significantly with worsening scan result. Multivariable analysis revealed that the only predictor of referral to catheterization was the extent and severity of reversible defect present on the scan. Referral rates to early catheterization were very low in patients with normal scans and increased significantly as a function of worsening scan results. In patients who underwent myocardial perfusion SPECT using adenosine stress, the results of nuclear testing yielded incremental prognostic information and clinically relevant risk stratification. Referring physicians predominantly utilized nuclear information when referring patients to catheterization after nuclear testing and do so at rates comparable with those after exercise SPECT despite the higher risk of events in patients undergoing pharmacologic stress.  相似文献   

8.
Tc-99m sestamibi has been shown to accumulate in several primary malignant tumors, but data regarding its use in the detection of distant metastases are limited. Despite its physical limitations, Tl-201 now has a definite place in the routine evaluation of certain primary and metastatic tumors. This report describes the value of Tc-99m sestamibi and its superiority to Tl-201 in the visualization of distant metastases in a 2-year-old girl with bilateral retinoblastoma. Three sites of soft tissue and bone metastasis were demonstrated by Tc-99m sestamibi imaging. Of these metastases, the one in the parieto-occipital region showed evident Tl-201 uptake, while the other two in the right arm and chest wall showed only slightly increased uptake, which could hardly be spotted without the confirmation of a later Tc-99m sestamibi scan. The scintigraphic findings were confirmed with histopathologic examination. Tc-99m sestamibi scan is effective and superior to Tl-201 in the detection of distant soft tissue and bone metastases from retinoblastoma.  相似文献   

9.
A retrospective chart review of 43 patients who underwent technetium 99m (Tc-99m) sestamibi scans from June 1995 to January 1997 was performed. Only those who underwent subsequent parathyroid exploration with excision were included in the study. Twenty subjects (13 women and seven men) were included in the study. Ages ranged from 21 to 84 years (mean, 58 years). All patients had laboratory values and clinical findings consistent with primary hyperparathyroidism. Two patients had preoperative magnetic resonance imaging (MRI) scans (one patient with recurrent disease), and one had a preoperative computed tomography (CT) scan. The remaining patients had the sestamibi scan as the only preoperative localization study. There were 18 pathologic diagnoses of parathyroid adenoma and two of parathyroid hyperplasia. Sestamibi failed to correctly identify the location of the parathyroid lesion in two cases. In 18 cases the preoperative sestamibi scan correctly localized the lesion, a predictive value of 90%. We conclude that the Tc-99m sestamibi scan is an accurate preoperative tool that can be used as a single modality to localize parathyroid adenomas.  相似文献   

10.
Stress myocardial perfusion imaging has become a mainstay in the noninvasive assessment of patients with known or suspected coronary artery disease for several compelling reasons. Radionuclide myocardial perfusion imaging can be performed using a variety of stressors, including exercise, pharmacologic stress (including dipyridamole, adenosine, dobutamine, and arbutamine), or a combination of exercise and pharmacologic stress. The combination of exercise and pharmacologic stress allows an assessment of the patient's exercise tolerance, to be performed while adequately stressing him or her pharmacologically. Radiopharmaceutical choice has been expanded to include not only thallium-201 but also technetium-based imaging agents such as sestamibi and tetrofosmin. The use of technetium imaging agents has recently been enhanced by the ability to assess ventricular function using gated single-photon emission computed tomography (SPECT) imaging techniques. Finally, the ability to provide prognostic information in the same patients has led to incremental clinical use.  相似文献   

11.
The validity of dual energy single-photon emission computed tomography (SPECT) with technetium-99m pyrophosphate (Tc-99m PPi) and thallium-201 for the diagnosis of right ventricular (RV) infarction, and the clinical features of RV infarction, were investigated in 190 patients with acute myocardial infarction. Diagnosis of RV infarction was performed by Tc-99m PPi accumulation in the RV myocardium on thallium-201 and Tc-99m PPi over-lay images at the dual SPECT with simultaneous imaging taken 2 to 9 days after the onset of myocardial infarction. Thirty RV infarctions were found among the 190 patients with left ventricular infarction (15.8%): 29 (97%) in association with the inferior and 1 (3%) with the lateral infarction. Tc-99m PPi accumulation was mostly observed in the posterior wall of the right ventricle. A total occlusion or a severe stenosis of the right coronary artery was demonstrated angiographically in 92% of the patients with RV infarction. The prevalence of RV infarctions was significantly lower in patients who achieved successful early reperfusion than in those who did not (26.7 vs 68.4%, respectively, p < 0.01). However, a successful early reperfusion therapy could not significantly decrease the rate of RV involvement in patients without significant collateral flow (p < 0.01). Thus, dual isotope SPECT with Tc-99m PPi and thallium-201 can be used as a reliable method for the diagnosis of RV infarction.  相似文献   

12.
The clinical presentation, electrocardiographic findings, and technetium-99m sestamibi single-photon emission computed tomography (SPECT) imaging results of 134 consecutive patients who underwent nuclear exercise testing within 14 days of an acute myocardial infarction (AMI) were correlated with cardiac events over a 15 +/- 10-month follow-up. Whereas only 23 patients (17%) had chest pain and 31 (23%) had ischemic ST-segment depression during exercise, 94 (70%) had ischemia on SPECT (p < 0.001). On follow-up, 13 patients experienced a cardiac event: 7 were rehospitalized for unstable angina, 3 had recurrent AMI, and 3 died of cardiac causes. Ischemia on the sestamibi images identified 11 of these patients (85%), whereas chest pain identified only 3 (23%, p = 0.006), and electrocardiographic ischemia identified only 4 (31%, p = 0.017). The presence of either ischemia as seen on SPECT or defects in multiple vascular territories identified 12 patients (92%) with an event, including all who had cardiac death. By Cox regression analysis of clinical, stress, and image parameters, the number of ischemic defects on SPECT was the only significant correlate of a future event (chi-square = 4.62, p = 0.03), and patients with > or = 3 reversible sestamibi defects had an event rate of 38%. The extent of ischemia as seen on nuclear imaging remained a strong correlate (p = 0.008) of an event in the 54 patients (40%) who had received thrombolytic therapy. Thus, exercise technetium-99m sestamibi SPECT after AMI frequently reveals residual ischemia, and is better than clinical data, symptoms, and stress electrocardiographic data in identifying patients who will have a subsequent cardiac event.  相似文献   

13.
In recent years, substantial progress has been made in the field of nuclear cardiology. Pharmacologic stress perfusion imaging with intravenous administration of dipyridamole or adenosine provides comparable sensitivity and specificity values for detection of coronary artery disease (CAD) as exercise imaging and has been employed successfully for risk stratification prior to peripheral vascular or aortic surgery and after myocardial infarction. Detection of myocardial viability can be enhanced utilizing reinjection of a second dose of thallium-201 (Tl-201) at rest after acquisition of redistribution images with the single photon emission computerized tomography (SPECT) technique. Imaging solely in the resting state with Tl-201 can also provide information concerning presence of viable myocardium in asynergic regions that are stunned or hibernating. New technetium-99m (Tc-99m) perfusion agents have emerged in the clinical setting and have provided excellent predictive value for detection of CAD in patients with chest pain and permit simultaneous assessment of function and regional blood flow. Tc-99m Sestamibi, one of these agents, is also a valid marker of viability when assessing myocardial salvage after coronary reperfusion in acute myocardial infarction.  相似文献   

14.
The purpose of this study was to determine whether exercise technetium-99m sestamibi gated single-photon emission computed tomography (SPECT) accurately distinguishes between patients with ischemic cardiomyopathy and patients with nonischemic left ventricular systolic dysfunction. Noninvasive tests have previously failed to accurately separate patients with ischemic cardiomyopathy from those with nonischemic cardiomyopathy. Technetium-99m gated SPECT imaging offers advantages that have the potential to overcome the limitations of previous studies. Thirty-seven adults with a left ventricular ejection fraction < or = 35%, including 24 patients with nonischemic cardiomyopathy and 13 patients with ischemic cardiomyopathy, were prospectively evaluated using symptom-limited metabolic exercise treadmill testing with technetium-99m sestamibi gated SPECT imaging. Interpretation of myocardial perfusion and regional wall motion was performed, using a 17-segment model. Summed stress, rest, and reversibility perfusion defect scores were determined, and the variance of segmental wall motion scores was computed. Summed stress, rest, and reversibility perfusion defect scores were significantly lower in nonischemic cardiomyopathy patients, compared with those with ischemic cardiomyopathy (summed stress defect score: 6.9 +/- 3.8 vs 32.9 +/- 7.7, respectively, p <0.001). Variability in segmental wall motion was also significantly lower in patients with nonischemic cardiomyopathy compared with those with ischemic cardiomyopathy (variance: 0.3 +/- 0.3 vs 1.2 +/- 0.8, respectively, p <0.001). Thus, assessment of myocardial perfusion and regional ventricular function with exercise technetium-99m sestamibi gated SPECT imaging can reliably distinguish between patients with ischemic cardiomyopathy and patients with nonischemic dilated cardiomyopathy.  相似文献   

15.
BACKGROUND: We evaluated the prognostic value of exercise 201Tl indexes of myocardial hypoperfusion in patients with suspected or known coronary artery disease. METHODS AND RESULTS: Patients were divided into two groups: group I consisted of 332 patients with diagnostic electrocardiographic stress test results and group II consisted of 144 patients with nondiagnostic (inadequate or uninterpretable) stress electrocardiograms. At the 2-year follow-up, 20 hard events (16 cardiac deaths and 4 nonfatal myocardial infarctions) and 80 soft events (coronary revascularization procedures) occurred in group I. Considering total events, thallium imaging provided significant prognostic information in addition to clinical and exercise stress test data in the total study population (p < 0.001) and in patients with previous myocardial infarction (p < 0.001); in patients without previous infarction, thallium imaging added incremental prognostic value only in those with positive electrocardiographic stress test results (p < 0.01). When only hard events were considered, thallium variables added further information only in patients with previous myocardial infarction (p < 0.05). In group II at the end of follow-up, 15 hard and 39 soft events had occurred. In these patients occurrence of total (p < 0.001), hard (p < 0.05), and soft (p < 0.001) events was higher in those with abnormal thallium scintigraphic results than in those without. Moreover, no clinical and exercise variable, except history of myocardial infarction, was significantly related to outcome, whereas both indexes of extent and severity of hypoperfusion were significant. CONCLUSIONS: The results of this study demonstrate that scintigraphic indexes of myocardial hypoperfusion obtained by qualitative planar thallium imaging give unique prognostic information in patients with nondiagnostic electrocardiographic stress test results. Thallium imaging provides incremental prognostic information even in patients with diagnostic electrocardiographic stress test results but not in the low-risk subset of patients without previous infarction who have negative electrocardiographic stress test results.  相似文献   

16.
JP Wei  GJ Burke 《Canadian Metallurgical Quarterly》1997,63(12):1097-100; discussion 1100-1
Tc-99m-sestamibi has been shown to localize parathyroid adenomas effectively, but controversy continues as to the use of this scan before initial surgery for primary hyperparathyroidism. We analyzed the cost utility of obtaining this study before initial surgery for primary hyperparathyroidism. Twenty-two consecutive patients with primary hyperparathyroidism underwent dual-phase Tc-99m-sestamibi scan before initial bilateral neck exploration. Surgical findings were correlated with the results of sestamibi scan. There were 15 women and 7 men, with a mean age of 50.5 years (range, 22-76). Preoperative mean total calcium was 11.74 mg/dL (range, 10-15), ionized calcium was 6.19 mg/dL (range, 5.2-7.7), and intact parathyroid hormone was 153.5 pg/mL (range, 83.1-551). Postoperative mean ionized calcium was 4.56 mg/dL (range, 4.1-5.57). Twenty sestamibi scans had a positive localization, and 2 scans had no localization. At surgery, 18 solitary adenomas, 3 diffuse hyperplasias, and 1 patient with four normal parathyroid glands were found. Sixteen sestamibi scans were true positive (solitary adenoma), 4 scans were false positive (2 diffuse hyperplasia, 1 wrong side, and 1 lymph node), 1 negative scan was true negative (diffuse hyperplasia), and 1 negative scan was false negative (adenoma). One patient (four normal glands) at the second operation had a supernumerary fifth gland adenoma excised from the mediastinum. Preoperative Tc-99m-sestamibi scan did not offer any advantage when a complete bilateral neck exploration is performed. Sixteen of (84%) adenomas were correctly localized, but 18 of 19 adenomas were in the neck and were easily found. The 1 ectopic adenoma was not found by scanning or with initial surgery. The 4 of 22 (18%) false-positive localizations and the 2 of 22 (9%) negative scans contributed nothing to the surgery. Of the 22 localizing sestamibi scans, surgery was not altered to affect the outcome. At a cost of $550 per sestamibi scan and with the error inherent in the scan, it is not cost effective to obtain Tc-99m-sestamibi scan before initial surgery for primary hyperparathyroidism.  相似文献   

17.
PURPOSE: To assess the role of regional cerebral blood flow measured by technetium-99m hexamethyl propyleneamine oxime (HMPAO) brain single-photon emission CT (SPECT) in viral encephalitis of children. METHODS: Eighteen children diagnosed as having viral encephalitis (12 Epstein-Barr virus, 4 herpes simplex virus, and 2 Japanese B virus) underwent Tc-99m HMPAO brain SPECT and brain MR and/or CT. RESULTS: During the acute episode, 4 (22%) of the 18 patients had localized abnormality on brain MR and/or CT. Tc-99m HMPAO brain SPECT in the acute phase showed that 17 (94%) of the 18 patients had increased regional cerebral blood flow and 1 (6%) of the 18 children had a normal brain SPECT. Follow-up brain SPECT was performed at least 15 days after the acute episode. In 17 patients with abnormal first brain SPECT, 12 (71%) had normal second brain SPECT and 5 (29%) had decreased regional cerebral blood flow. The group of patients with normal regional cerebral blood flow on the follow-up brain SPECT had a better outcome than the group of patients with decreased regional cerebral blood flow. CONCLUSIONS: (a) The Tc-99m HMPAO brain SPECT was abnormal more often than CT or MR in children with acute viral encephalitis and provided better location. (b) In acute episodes of encephalitis, most patients showed locally increased regional cerebral blood flow. (c) After acute episodes, the regional cerebral blood flow returned to normal in most cases. (d) A normal Tc-99m HMPAO brain SPECT in the subacute phase usually indicates a good clinical outcome (no neurologic defect) 1 year after the acute illness in children with viral encephalitis.  相似文献   

18.
Tc-99m sestamibi imaging was performed in two patients with multiple myeloma. Focal areas of increased uptake in one patient and diffuse skeletal uptake in the second patient were found. Tc-99m sestamibi appears to identify bone marrow and osteolytic involvement in multiple myeloma.  相似文献   

19.
Technetium-99m sestamibi (MIBI) is a routinely used myocardial perfusion imaging agent. We have studied groups of patients with differentiated thyroid carcinoma, in order to evaluate the usefulness of this agent in localising regional neck and nodal disease and metastases. There are three groups of patients. Group 1 consisted of patients with known nodal disease or metastases (22 patients) and with raised serum thyroglobulin levels (Tg). Group 2 comprised patients with normal I-131 scans and normal Tg levels (nine patients). Non-thyroid malignancies (six patients) comprised an additional group 3. In group 1, the MIBI scan showed 47 sites of metastases, while the I-131 scan revealed 49 sites. The MIBI scan was positive in two patients where the I-131 scan was negative, while in two other patients, the MIBI study was negative whereas the I-131 scan was positive. In group 2, 6/9 patients had no disease, 2/9 had thyroid remnants, and 1/9 had a fresh primary lung tumour, unrelated to the earlier thyroid cancer. All of them had normal MIBI scans. In group 3, two patients with lung cancer and two with breast cancer and metastases had normal MIBI scans. A further two patients with nasopharyngeal cancer (NPC) had mildly increased MIBI localisation in neck nodes and bone metastases. In summary, Tc-99m sestamibi appears to be as good as I-131 in search for thyroid carcinoma metastatic spread, especially nodal disease and this tracer does not localise well in the primary or metastases of other cancers.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

20.
Single photon emission computed tomography (SPECT) with Technetium-99m hexamethyl propylenamine oxime (Tc-99m-HMPAO) was used in 20 patients with mild to moderate traumatic brain injury (TBI) to evaluate the effects of brain trauma on regional cerebral blood flow (rCBF). SPECT scan was compared with CT scan in 16 patients. SPECT showed intraparenchymal differences in rCBF more often than lesions diagnosed with CT scans (87.5% vs. 37.5%). In five of six patients with lesions in both modalities, the area of involvement was relatively larger on SPECT scans than on CT scans. Contrecoup changes were seen in five patients on SPECT alone, two patients with CT alone and one patient had contrecoup lesions on CT and SPECT. Of the eight patients (50%) with skull fractures, seven (43.7%) had rCBF findings on SPECT scan and five (31.3%) demonstrated decrease in rCBF in brain underlying the fracture. All these patients with fractures had normal brain on CT scans. Conversely, extra-axial lesions and fractures evident on CT did not visualize on SPECT, but SPECT demonstrated associated changes in rCBF. Although there is still lack of clinical and pathological correlation, SPECT appears to be a promising method for a more sensitive evaluation of axial lesions in patients with mild to moderate TBI.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号