首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
The 4.4 MeV photon reference field described in ISO 4037 is produced by the (12)C(p,p')(12)C (E(x) = 4.4389 MeV) reaction using a thick elemental carbon target and a proton beam with an energy of 5.7 MeV. The relative abundance of the isotope (13)C in elemental carbon is 1.10%. Therefore, the 4.4 MeV photon field is contaminated by neutrons produced by the (13)C(p,n) (13)N reaction (Q = -3.003 MeV). The ambient dose equivalent H*(10) produced by these neutrons is of the same order of magnitude as the ambient dose equivalent produced by the 4.4 MeV photons. For the calibration of dosemeters, especially those also sensitive to neutrons, the spectral fluence distribution of these neutrons has to be known in detail. On the other hand, a mixed photon/neutron field is very useful for the calibration of tissue-equivalent proportional counters (TEPC), if this field combines a high-linear energy transfer (LET) component produced by low-energy neutrons and a low-LET component resulting from photons with about the same ambient dose equivalent and energies up to 7 MeV. Such a mixed field was produced at the PTB accelerator facility using a thin CaF(2) + (nat)C target and a 5.7 MeV proton beam.  相似文献   

3.
A nonuniform sampling scheme is described for measuring the mutual intensity of the wave field produced in a plane a distance z from a spatially incoherent, three-dimensional source object. Both uniform and nonuniform sampling are analyzed and discussed in detail, and comparisons of the two schemes are made. It is shown that nonuniform sampling requires fewer measurements than uniform sampling to specify the coherence function. Additionally, the smallest separation required between measurement points is larger for the nonuniform case.  相似文献   

4.
A novel neutron microbeam is being developed at the Radiological Research Accelerator Facility (RARAF) of Columbia University. The RARAF microbeam facility has been used for studies of radiation bystander effects in mammalian cells for many years. Now a prototype neutron microbeam is being developed that can be used for bystander effect studies. The neutron microbeam design here is based on the existing charged particle microbeam technology at the RARAF. The principle of the neutron microbeam is to use the proton beam with a micrometre-sized diameter impinging on a very thin lithium fluoride target system. From the kinematics of the ?Li(p,n)?Be reaction near the threshold of 1.881 MeV, the neutron beam is confined within a narrow, forward solid angle. Calculations show that the neutron spot using a target with a 17-μm thick gold backing foil will be <20 μm in diameter for cells attached to a 3.8-μm thick propylene-bottomed cell dish in contact with the target backing. The neutron flux will roughly be 2000 per second based on the current beam setup at the RARAF singleton accelerator. The dose rate will be about 200 mGy min?1. The principle of this neutron microbeam system has been preliminarily tested at the RARAF using a collimated proton beam. The imaging of the neutron beam was performed using novel fluorescent nuclear track detector technology based on Mg-doped luminescent aluminum oxide single crystals and confocal laser scanning fluorescent microscopy.  相似文献   

5.
A pilot accelerator-based source of epithermal neutrons, which is intended for wide application in clinics for boron neutron capture therapy, has been constructed at the Budker Institute of Nuclear Physics (Novosibirsk). A stationary proton beam has been obtained and near-threshold neutron generation regime has been realized. Results of the first experiments on neutron generation using the proposed source are described.  相似文献   

6.
A device based on a single silicon detector of special converter/detector design optimised for the determination of the neutron dose equivalent is also used for the determination of the photon dose equivalent. While the neutron dose is determined on the basis of signals corresponding to energy depositions above 1.5 MeV, depositions between 80 keV and 150 keV are used for the photon dose equivalent. In this way, a photon response is achieved which varies by less than 30% in the energy region from 80 keV to 7 MeV for irradiation at normal incidence and at 60 degrees to the normal. The lower limit of detection is of the order of 1 microSv. Neutrons contribute to the photon reading by less than 2% in mixed fields with a comparable dose equivalent from neutrons and photons.  相似文献   

7.
Within the EU Project EVIDOS, a spectrometer with 24 silicon detectors mounted on the surface of a polyethylene sphere is used for the determination of the energy and direction distribution of neutrons and photons. It has been characterized with respect to neutron radiation with energies from thermal up to 15 MeV and to photon radiation with energies from 65 keV to 6 MeV. The first measurements described here were performed in the simulated workplace field, CANEL, at Cadarache, with the purpose of checking the instrument and the unfolding procedures.  相似文献   

8.
The accelerator-based in vivo neutron activation facility at McMaster University has been used successfully for the measurement of several minor and trace elements in human hand bones due to their importance to health. Most of these in vivo measurements have been conducted at a proton beam energy (E(p)) of 2.00 MeV to optimise the activation of the selected element of interest with an effective dose of the same order as that received in chest X rays. However, measurement of other elements at the same facility requires beam energies other than 2.00 MeV. The range of energy of neutrons produced at these proton beam energies comes under the region where tissue-equivalent proportional counters (TEPCs) are known to experience difficulty in assessing the quality factor and dose equivalent. In this study, the response of TEPCs was investigated to determine the quality factor of neutron fields generated via the (7)Li(p, n)(7)Be reaction as a function of E(p) in the range 1.884-2.56 MeV at the position of hand irradiation in the facility. An interesting trend has been observed in the quality factor based on ICRP 60, Q(ICRP60), such that the maximum value was observed at E(p)=1.884 MeV (E(n)=33±16 keV) and then continued to decline with increasing E(p) until achieving a minimum value at E(p)=2.0 MeV despite a continuous increase in the mean neutron energy with E(p). This observation is contrary to what has been observed with direct fast neutrons where the quality factor was found to increase continuously with an increase in E(p) (i.e. increasing E(n)). The series of measurements conducted with thermal and fast neutron fields demonstrate that the (14)N(n, p)(14)C produced 580 keV protons in the detector play an important role in the response of the counter under 2.0 MeV proton energy (E(n) ≤ 250 keV). In contrast to the lower response of TEPCs to low-energy neutrons, the quality factor is overestimated in the range 1-2 depending on beam energy <2.0 MeV. This study provides an insight to understanding the response of TEPCs in low-energy neutron fields where the neutrons are moderated using a polyethylene moderator.  相似文献   

9.
EVIDOS is an EC sponsored project that aims at an evaluation and improvement of radiation protection dosimetry in mixed neutron/photon fields. This is performed through spectrometric and dosimetric investigations during different measurement campaigns in representative workplaces of the nuclear industry. The performance of routine and, in particular, novel personal dosemeters and survey instruments is tested in selected workplace fields. Reference values for the dose equivalent quantities, H(*)(10) and H(p)(10) and the effective dose E, are determined using different spectrometers that provide the energy distribution of the neutron fluence and using newly developed devices that determine the energy and directional distribution of the neutron fluence. The EVIDOS project has passed the mid-term, and three measurement campaigns have been performed. This paper will give an overview and some new results from the third campaign that was held in Mol (Belgium), around the research reactor VENUS and in the MOX producing plant of Belgonucléaire.  相似文献   

10.
EVIDOS ('evaluation of individual dosimetry in mixed neutron and photon radiation fields') is an European Commission (EC)-sponsored project that aims at a significant improvement of radiation protection dosimetry in mixed neutron/photon fields via spectrometric and dosimetric investigations in representative workplaces of the nuclear industry. In particular, new spectrometry methods are developed that provide the energy and direction distribution of the neutron fluence from which the reference dosimetric quantities are derived and compared to the readings of dosemeters. The final results of the project will be a comprehensive set of spectrometric and dosimetric data for the workplaces and an analysis of the performance of dosemeters, including novel electronic dosemeters. This paper gives an overview of the project and focuses on the results from measurements performed in calibration fields with broad energy distributions (simulated workplace fields) and on the first results from workplaces in the nuclear industry, inside a boiling water reactor and around a spent fuel transport cask.  相似文献   

11.
High pressure gas spheres have been designed and successfully used in several nuclear physics experiments on noble gases. The pros and cons of this solution are the simple design and the high reliability versus the fact that the density is limited to 40–60% of liquid or solid gas samples. Originally produced for neutron capture studies at keV energies, the comparably small mass of the gas spheres were an important advantage, which turned out to be of relevance for other applications as well. The construction, performance, and operation of the spheres are described and examples for their use are presented.  相似文献   

12.
The beam shaping assembly design has been investigated in order to improve the epithermal neutron beam for accelerator-based boron neutron capture therapy in intensity and quality, and dosimetric evaluation for the beams has been performed using both mathematical and voxel head phantoms with MCNP runs. The neutron source was assumed to be produced from a conventional 2.5 MeV proton accelerator with a thick (7)Li target. The results indicate that it is possible to enhance epithermal neutron flux remarkably as well as to embody a good spectrum shaping to epithermal neutrons only with the proper combination of moderator and reflector. It is also found that a larger number of thermal neutrons can reach deeply into the brain and, therefore, can reduce considerably the treatment time for brain tumours. Consequently, the epithermal neutron beams designed in this study can treat more effectively deep-seated brain tumours.  相似文献   

13.
Experiments were performed in Cave C of GSI (Gesellschaft für Schwerionenforschung) using the LAND (Large Area Neutron Detector) in combination with the deflection magnet ALADIN (A LArge DIpol magNet) in front of the LAND where charged particles and neutrons can be separated. This arrangement is used to create high-energetic neutron fields by irradiation of a thick lead target (5 cm) with deuteron beams with the energies of 500 or 800 MeV per nucleon. In break-up reactions the neutron is separated from the proton which is deflected in the magnetic field of the ALADIN. The produced neutron radiation, which has a pronounced peak at the nucleon energy, is used to measure the fluence response of the GSI neutron ball. A thermoluminescence (TL) based spherical neutron dosemeter was developed for the area monitoring for the quantity H(10) at high-energy accelerators. In the same experiment, the spectral neutron fluence Phi(E) is measured with the LAND in the energy range from 100 MeV to 1 GeV. The measured fluence responses are compared with results of FLUKA calculations and the corresponding fluence-to-dose conversion coefficients. The measured dosemeter responses are too high in comparison to the calculated ones (up to approximately 50%), the dosemeter reading gives dose values which are too high by a factor of 1.1-2.2 related to the corresponding fluence-to-dose conversion factors.  相似文献   

14.
15.
16.
17.
18.
The paper presents the main conclusions and recommendations derived from the EVIDOS project, which is supported by the European Commission within the 5(th) Framework Programme. EVIDOS aims at evaluating state of the art neutron dosimetry techniques in representative workplaces of the nuclear industry with complex mixed neutron-photon radiation fields. This analysis complements a series of individual papers which present detailed results and it summarises the main findings from a practical point of view. Conclusions and recommendations are given concerning characterisation of radiation fields, methods to derive radiation protection quantities and dosemeter results.  相似文献   

19.
A compact fast neutron detector based on beryllium activation has been developed to perform accurate neutron fluence measurements on pulsed DD fusion sources. It is especially well suited to moderate repetition-rate (<0.2 Hz) devices, such as the plasma focus or Z-pinch. The detector comprises a beryllium metal sheet sandwiched between two large-area xenon-filled proportional counters. A methodology for calculating the absolute response function of the detector using a “first principles” approach is described. This calibration methodology is based on the 9Be(n,α)6He cross-section, energy calibration of the proportional counters, and numerical simulations of neutron interactions and beta-particle paths using MCNP5. The response function R(En) is determined over the neutron energy range 2-4 MeV. The count rate capability of the detector has been studied and the corrections required for high neutron fluence measurements are discussed. For pulsed DD neutron fluencies >3×104 cm−2, the statistical uncertainty in the fluence measurement is better than 1%. A small plasma focus device has been employed as a pulsed neutron source to test two of these new detectors, and their responses are found to be practically identical. Also the level of interfering activation is found to be sufficiently low as to be negligible.  相似文献   

20.
Multiexciton generation by a single photon in nanocrystals   总被引:1,自引:0,他引:1  
Shabaev A  Efros AL  Nozik AJ 《Nano letters》2006,6(12):2856-2863
We have theoretically shown that efficient generation of multi-electron-hole pairs by a single photon observed recently in semiconductor nanocrystals1-4 is caused by breaking the single electron approximation for carriers with kinetic energy above the effective energy gap. Due to strong Coulomb interaction, these states form a coherent superposition with charged excitons of the same energy. This concept allows us to define the conditions for dominant two-exciton generations by a single photon: the thermalization rate of a single exciton, initiated by light, should be lower than both the two-exciton state thermalization rate and the rate of Coulomb coupling between single and two exciton states. Possible experimental manifestations of our model are discussed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号