首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 421 毫秒
1.
A simplified and standardized technique for close correlation between light microscopy (LM), transmission electron microscopy (TEM) and scanning electron microscopy (SEM) is described. Perfusion and immersion fixed tissue specimens were embedded in Epon 812 and cut for conventional LM and TEM. The Epon blocks with remaining tissue were thereafter treated with epoxy solvent (ethanol-NaOH solution) for partial epoxy resin removal only (dissolving rate approx 33μm/h). The blocks with partially blotted tissue specimens were then critically point dried and gold coated for SEM. This method, in an easy way, allows repeated observations with LM, TEM and SEM with preserved fine structure and exact correlation. Since the technique is so simple and there is no need for special equipment the method can easily be adopted in all laboratories with basic SEM standards.  相似文献   

2.
A method for bacterial identification has been developed by means of studying the same histological sections through several types of microscopy. With this method, one section was processed and analyzed respectively for light microscopy (LM), scanning electron microscopy (SEM), and transmission electron microscopy (TEM). Sections of gingival biopsies were Gram stained and bacteria tentatively identified by LM. Photographs of the sections were taken and presketched transparent acetate sheets (PTAS) were made from the photos. The same section was later prepared for SEM, areas previously thought to contain bacteria were localized by placing the PTAS onto the SEM monitoring screen. The SEM specimens were subsequently processed for TEM, bacteria were located, and micrographs obtained. The results showed that out of ten diseased gingival biopsies observed under the LM, bacteria were found to be present in all the specimens and were identified as both Gram positive and Gram negative. By transferring the section from LM to SEM, the bacteria could be relocated and their morphotype (cocci, rods, etc.) clearly identified in most of the cases. Since cocci may resemble other biological granular structures under SEM, they require further analysis under TEM for additional positive identification. This study demonstrated that the method described here is a useful tool for assessing the presence and identifying bacteria within the gingival tissues.  相似文献   

3.
We demonstrate the preparation of samples of streptomycetes (Streptomyces coelicolor, S. aureofaciens) cultured on glass beads (balotina) for scanning electron microscopy. The main trick of the method consists in immobilization of glass beads with low-melting agarose. The samples are then fixed in OsO(4) vapors followed by dehydration in vapors of absolute ethanol. No air-to-liquid transition during the sample preparation occurs. Consequently, whole cell cycle of streptomycetes in the term of mycelial morphology can readily be studied by this method.  相似文献   

4.
Rat liver sinusoidal endothelial cells (LEC) contain fenestrae, which are clustered in sieve plates. Fenestrae control the exchange of fluids, solutes and particles between the sinusoidal blood and the space of Disse, which at its back side is flanked by the microvillous surface of the parenchymal cells. The surface of LEC can optimally be imaged by scanning electron microscopy (SEM), and SEM images can be used to study dynamic changes in fenestrae by comparing fixed specimens subjected to different experimental conditions. Unfortunately, the SEM allows only investigation of fixed, dried and coated specimens. Recently, the use of atomic force microscopy (AFM) was introduced for analysing the cell surface, independent of complicated preparation techniques. We used the AFM for the investigation of cultured LEC surfaces and the study of morphological changes of fenestrae. SEM served as a conventional reference.
AFM images of LEC show structures that correlate well with SEM images. Dried-coated, dried-uncoated and wet-fixed LEC show a central bulging nucleus and flat fenestrated cellular processes. It was also possible to obtain height information which is not available in SEM. After treatment with ethanol or serotonin the diameters of fenestrae increased (+6%) and decreased (−15%), respectively. The same alterations of fenestrae could be distinguished by measuring AFM images of dried-coated, dried-uncoated and wet-fixed LEC. Comparison of dried-coated (SEM) and wet-fixed (AFM) fenestrae indicated a mean shrinkage of 20% in SEM preparations. In conclusion, high-resolution imaging with AFM of the cell surface of cultured LEC can be performed on dried-coated, dried-uncoated and wet-fixed LEC, which was hitherto only possible with fixed, dried and coated preparations in SEM and transmission electron microscopy (TEM).  相似文献   

5.
Common methods for the preparation of cultured cells for concurrent light microscopy (LM), scanning electron microscopy (SEM), and transmission electron microscopy (TEM) are not completely satisfactory. This article describes how we grow mammalian cells on plastic disks made from Aclar film. Aclar is a transparent fluorinated-chlorinated thermoplastic that contains no volatile components and is, for all practical purposes, chemically inert. Cells adhere to it readily and remain attached after fixation, dehydration, and critical-point drying or embedding. The film also accepts heavy metal coating by ionic bombardment and is extremely stable in the vacuum of the SEM. LM observations are unhindered by Aclar, since the film is as transparent as glass. Fluorescence microscopy is possible with this film, since it exhibits no detectable autofluorescence. During SEM observation, the film has great dimensional stability, and the cells and heavy metal coating remain attached to the Aclar even under high-resolution operating conditions. TEM processing of specimens grown on Aclar is simplified by the fact that Aclar does not stick to the epoxy resins used in EM. Furthermore, Aclar is easily sectioned and does not damage knives used in ultramicrotomy. The use of Aclar film considerably simplifies the preparation of cultured cells for all types of microscopy. This method is particularly useful in correlating surface features between SEM and TEM observations.  相似文献   

6.
Thin paraffin sections, mounted on scanning specimen holders previously coated with polyester film tape (Minnesota Mining and MFG Co., Scotch film tape No. 850 gold), were processed for light microscopy (LM) in the conventional way, then covered with celloxin shellac and examined in the LM by using the upper illuminating source. After removal of the shellac from the surface of the sample by immersion in acetone, the sections were air-dried, coated with a copper layer in a vacuum evaporator and examined in a scanning electron microscope (SEM). The method allows: (i) high-quality LM possibilities for establishment of the diagnosis in pathological cases; (ii) SEM examination of the same area as observed in LM; and (iii) EPMA measurements of insoluble precipitates embedded in the tissue. The usefulness of the proposed method is obvious in cases where the composition of a precipitate on LM scale is to be compared with the LM appearance of the surrounding tissue.  相似文献   

7.
When electron microscopy (EM) was introduced in the 1930s it gave scientists their first look into the nanoworld of cells. Over the last 80 years EM has vastly increased our understanding of the complex cellular structures that underlie the diverse functions that cells need to maintain life. One drawback that has been difficult to overcome was the inherent lack of volume information, mainly due to the limit on the thickness of sections that could be viewed in a transmission electron microscope (TEM). For many years scientists struggled to achieve three‐dimensional (3D) EM using serial section reconstructions, TEM tomography, and scanning EM (SEM) techniques such as freeze‐fracture. Although each technique yielded some special information, they required a significant amount of time and specialist expertise to obtain even a very small 3D EM dataset. Almost 20 years ago scientists began to exploit SEMs to image blocks of embedded tissues and perform serial sectioning of these tissues inside the SEM chamber. Using first focused ion beams (FIB) and subsequently robotic ultramicrotomes (serial block‐face, SBF‐SEM) microscopists were able to collect large volumes of 3D EM information at resolutions that could address many important biological questions, and do so in an efficient manner. We present here some examples of 3D EM taken from the many diverse specimens that have been imaged in our core facility. We propose that the next major step forward will be to efficiently correlate functional information obtained using light microscopy (LM) with 3D EM datasets to more completely investigate the important links between cell structures and their functions.  相似文献   

8.
Sample preparation for scanning electron microscopy (SEM) may vary by cellular type, composition and method of cultivation. It has been proposed here that a generalized method of sample preparation may be applied for the visualization of bacteria, fungi, and human cellular tissue without modification of protocol between cell types. The following protocol was developed to incorporate polystyrene disk substrates in the simplification of sample preparation for SEM and reduce the possibility of processing artefacts. The proposed method of preparation may be applied to samples grown in either liquid or solid cultural medium regardless of cell type. With the proposed protocol, centrifugation, isolation and critical point drying are not required, therefore increasing specimen integrity. The incorporation of polystyrene disks showed positive cellular adhesion and applications in SEM for bacterial, fungal and human neuronal tissue. In addition, the simplicity of the proposed protocol is highly adaptable and may be further incorporated to visually analyse the effects of antifungals, antibiotics and disease pathogenesis through pathogen–host interactions. The proposed method of specimen preparation was incorporated in either liquid or solid state growth mediums during the cultivation of the selected cellular samples and revealed great promise in the preservation and visualization under the scanning electron microscope.  相似文献   

9.
This study was undertaken with the aim of identifying the different cell types found in human bone marrow by examining their surface morphology. In an attempt to obtain a homogeneous cell population, cells were both fractionated by discontinuous albumin density gradient centrifugation (DADGC) and selectively grown in nutrient agar. Both cell preparations underwent the critical point drying technique before examination under both the scanning electron microscope (SEM) and subsequently the light microscope (LM). When the SEM image of individual cells was compared with the corresponding LM image, it was not easy to identify the different cell types, because of the shrinkage and distortion that occurred during their preparation. The shrinkage observed under the SEM amounted to a 45% reduction in mean cell diameter. This shrinkage was confirmed by comparing the SEM and LM images of the same cell. Although shrinkage occurred throughout the dehydration sequence, critical point drying was responsible for a 25% reduction in mean cell diameter. Furthermore, direct observation under LM of fixed cells drying in air from ethanol, revealed visible contraction of the cell and distortion of the cell membrane. We assume that a similar morphological change occurred during critical point drying. We conclude that the shrinkage and distortion, caused by the dehydration process involved in SEM preparation, severely limit the value of a study of surface morphology by SEM in the identification of the different cell types found in human bone marrow.  相似文献   

10.
Critical-point drying and freeze drying were compared both quantitatively and qualitatively as preparative procedures for scanning electron microscopy. Isolated hepatocytes were used as model cells. Nomarski differential interference contrast microscopy was used for light microscopic measurements of the hepatocytes in the unfixed, the glutaraldehyde fixed, the glutaraldehyde + OsO4 fixed, the critical-point dried and the freeze dried states. Critical-point dried hepatocytes were found to shrink to 38% of glutaraldehyde + OsO4 fixed volume, whereas optimal freeze dried hepatocytes (frozen in water saturated with chloroform and freeze dried at 183 K for 84 h) were found to shrink to 51% of glutaraldehyde + OsO4 fixed volume. Transmission and scanning electron micrographs of the critical-point dried cells showed well-preserved ultrastructure and surface structure. Micrographs of the freeze dried cells showed ultrastructure destroyed by internal ice crystals and surface structure destroyed by external ice crystals. Double-fixed isolated hepatocytes were shown to swell during storage in buffer and to shrink during storage after critical-point drying. For low magnification scanning electron microscopy (up to about 3000 times) both critical-point drying and freeze drying can be used. However, for high magnification scanning electron microscopy, critical-point drying is superior to freeze drying.  相似文献   

11.
Fluorescence light microscopy (LM) has many advantages for the study of cell organization. Specimen preparation is easy and relatively inexpensive, and the use of appropriate tags gives scientists the ability to visualize specific proteins of interest. LM is, however, limited in resolution, so when one is interested in ultrastructure, one must turn to electron microscopy (EM), even though this method presents problems of its own. The biggest difficulty with cellular EM is its limited utility in localizing macromolecules of interest while retaining good structural preservation. We have built a cryo-light microscope stage that allows us to generate LM images of vitreous samples prepared for cryo-EM. Correlative LM and EM allows one to find areas of particular interest by using fluorescent proteins or vital dyes as markers within vitrified samples. Once located, the sample can be placed in the EM for further study at higher resolution. An additional benefit of the cryo-LM stage is that photobleaching is slower at cryogenic temperatures (−140°C) than at room temperature.  相似文献   

12.
When a new approach in microscopy is introduced, broad interest is attracted only when the sample preparation procedure is elaborated and the results compared with the outcome of the existing methods. In the work presented here we tested different preparation procedures for focused ion beam (FIB) milling and scanning electron microscopy (SEM) of biological samples. The digestive gland epithelium of a terrestrial crustacean was prepared in a parallel for FIB/SEM and transmission electron microscope (TEM). All samples were aldehyde-fixed but followed by different further preparation steps. The results demonstrate that the FIB/SEM samples prepared for conventional scanning electron microscopy (dried) is suited for characterization of those intracellular morphological features, which have membranous/lamellar appearance and structures with composition of different density as the rest of the cell. The FIB/SEM of dried samples did not allow unambiguous recognition of cellular organelles. However, cellular organelles can be recognized by FIB/SEM when samples are embedded in plastic as for TEM and imaged by backscattered electrons. The best results in terms of topographical contrast on FIB milled dried samples were obtained when samples were aldehyde-fixed and conductively stained with the OTOTO method (osmium tetroxide/thiocarbohydrazide/osmium tetroxide/thiocarbohydrazide/osmium tetroxide). In the work presented here we provide evidence that FIB/SEM enables both, detailed recognition of cell ultrastructure, when samples are plastic embedded as for TEM or investigation of sample surface morphology and subcellular composition, when samples are dried as for conventional SEM.  相似文献   

13.
A new sample holder that allows combined microtomy for atomic force microscopy (AFM) and transmission electron microscopy (TEM) is described. The main feature of this sample holder is a small central part holding the sample. This central part fits into the head of an atomic force microscope. AFM measurements can be performed with a sample mounted in this central part of the sample holder. This makes the alignment of a microtomed bulk sample unnecessary, and offers the opportunity of an easy and fast combined sample preparation for AFM and TEM.  相似文献   

14.
The utilization of tannic acid and guanidine hydrochloride as mordants for better osmium binding has been shown to serve as an excellent alternative to metal coating of organ tissue specimens for scanning electron microscopy (SEM). The present report describes the GTGO procedure, a modification of the TAO technique introduced by Murakami et al. (1977, 1978), which we have found successful for the preparation of air dried peripheral blood leucocytes for SEM studies. Air dried, GTGO-treated leucocytes show excellent preservation of surface features with minimal cell shrinkage. When critical point dried, GTGO-treated cells are examined, they also show less shrinkage than cells prepared with standard glutaraldehyde fixation and critical point drying. The potential application of this air drying procedure (GTGO-AD) to other soft biological specimens is currently under investigation. This technique is recommended as a new and effective air drying procedure for the successful preparation of cells for SEM.  相似文献   

15.
A Sbarbati  V Fanos  P Bernardi  L Tatò 《Scanning》2001,23(6):376-378
Intravascular catheters carry a significant risk of becoming colonized with bacteria and fungi and are important risk factors of septicemia in premature neonates. The study was undertaken to evaluate whether scanning electron microscopy (SEM) examination of removed catheters can be useful in early diagnosis of plastic infection by Candida, providing information useful for initiation of an eventual therapy. The evolution of biofilms in 28 catheters (umbilical or central) implanted in 24 newborns for prematurity was studied by SEM and transmission electron microscopy (TEM). In 4 of 24 patients, SEM examination revealed the presence of Candida in form of yeast or hyphae. In one of these patients, TEM confirmed the presence of organisms. In each case, hemoculture and culture of the catheter itself confirmed the diagnosis. The study demonstrates that SEM can identify fungi in the biomaterials covering the catheter surface in a few hours, allowing an early diagnosis of plastic infection.  相似文献   

16.
Critical point drying (CPD) is a common method of drying biological specimens for scanning electron microscopy (SEM). Drying by evaporation of hexamethyldisilazane (HMDS) has been described as a good alternative. This method, however, is infrequently used. Therefore, we reassessed HMDS drying. Cultured rat hepatic sinusoidal endothelial cells (LEC), possessing fragile fenestrae and sieve plates, were subjected to CPD and HMDS drying and evaluated in the scanning electron microscope, atomic force microscope (AFM) and transmission electron microscope (TEM). We observed no differences between the two methods regarding cellular ultrastructure. In contrast with CPD, HMDS drying takes only a few minutes, less effort, low costs for chemicals and requires no equipment. We conclude that HMDS-dried specimens have equal quality to CPD ones. Furthermore, the method also proved useful for drying whole-mount cells for TEM and AFM.  相似文献   

17.
Bacterial sample preparation is crucial for its observation by scanning electron microscopy (SEM). However, the current polylysine (PLL) method leads to bacterial morphological changes. To overcome this problem, we employed chitosan (CS) to coat coverslips to prepare bacteria for SEM and compared it with the PLL method. Coverslips coated with 0.025% (w/v) CS showed satisfactory bacterial binding ability. Within 30 min of binding time, the number of bacteria on CS-coated and PLL-coated coverslips exhibited no differences. Four bacteria strains were employed to compare the differences in SEM images between the two methods. Most of the bacteria showed irregular surface or sticky substances after settling on PLL-coated coverslips, while bacteria with clear surface texture were observed on CS-coated coverslips. Transmission electron microscopy (TEM) images showed deformed bacterial envelope on PLL-coated coverslips; meanwhile, similar intact envelope was observed from the bacteria on CS-coated coverslips and the bacteria without any treatment. The TEM results verified the morphological differences of SEM between the two methods. Except for morphology, the length of the rod-shaped bacteria was longer on CS-coated coverslips than that on PLL-coated coverslips, less shrinkage of the sample was observed, and CS could preserve the length of the rod-shaped bacteria better than PLL in its preparation for SEM. It is demonstrated that the low-cost CS could be utilized in bacterial preparation for SEM to acquire preferable images. Bacterial suspension with optical density at 600 nm of about 0.5, deposited on 0.025% CS-coated coverslips for 30 min, and followed by routine fixation, dehydration, and drying are optimal parameters.  相似文献   

18.
Using a high-intensity synchrotron X-ray source, the structural changes occurring in the corneal stroma were monitored during each stage of several different processing runs for the transmission electron microscope (TEM) and scanning electron microscope (SEM). The parameters studied were interfibrillar spacing, intermolecular spacing, D-periodicity and fibril diameter. The processing schedule that produced the least changes in spacings for TEM specimens involved extended fixation in glutaraldehyde followed by low-temperature embedding in Lowicryl K4M resin. However, interfibrillar material was better preserved after embedding in LR White resin or Nanoplast. Almost every processing stage for electron microscopy produced significant changes in one or more structural parameters in the cornea. Glutaraldehyde fixation significantly increased the intermolecular spacings, while resin infiltration and resin polymerization each resulted in shrinkage of all the spacings monitored. Critical-point drying for SEM specimens resulted in considerable shrinkage in all three spacings, but was still preferable to air drying, which caused reduction in the order of the fibril packing, resulting in loss of the interfibrillar X-ray pattern. Perhaps the most drastic effect was caused by post-fixation in osmium tetroxide, which resulted in loss of the intermolecular pattern, and also increased the amount of shrinkage in the interfibrillar spacings and the D-periodicity which occurred during later stages of processing.  相似文献   

19.
Atomic force microscopy (AFM) has been used to image a wide variety of cells. Fixed and dried-coated, wet-fixed or living cells were investigated. The major advantage of AFM over SEM is the avoidance of vacuum and electrons, whereas imaging can be done at environmental pressure and in aqueous conditions. Evidence of the successful application of AFM in biological imaging is provided by comparing results of AFM with SEM and/or TEM. In this study, we investigated surface and submembranous structures of living and glutaraldehyde-fixed colon carcinoma cells, skin fibroblasts and liver macrophages by AFM. Special attention was paid to the correct conditions for the acquisition of images of the surface of these cells, because quality SEM examinations have already been abundantly presented.
AFM imaging of living cells revealed specific structures, such as the cytoskeleton, which were not observed by SEM. Membrane structures, such as ruffles, lamellipodia, microspikes and microvilli, could only clearly be observed after fixing the cells with 0.1% glutaraldehyde. AFM images of living cells were comparable to SEM images of fixed, dried and coated cells, but contained a number of artefacts due to tip–sample interaction. In addition, AFM imaging allowed the visualization of cytoplasmic submembranous structures without the necessity for further preparative steps, allowing us: (i) to follow cytoskeletal changes in fibroblasts under the influence of the microfilament disrupting agent latrunculin A; (ii) to study particle phagocytosis in macrophages. Therefore, in spite of the slow image acquisition of the AFM, the instrument can be used for high-resolution real-time studies of dynamic changes in submembranous structures.  相似文献   

20.
An instrument for combined scanning electron microscopy (SEM) and light microscopy (LM) to which a photometer unit is attached is described. A special stage in the vacuum chamber of a scanning electron microscope incorporates light microscope optics (objective and condenser) designed for transmission and epi-illumination fluorescence LM. An optical bridge connects these optics to a light microscope, without objective and condenser. The possibility of performing quantitative DNA measurements in this combined microscope (the LM/SEM) was tested using preparations of either chicken erythrocytes, human lymphocytes, or mouse liver cells. The cells were fixed, brought on a cover-glass, quantitatively stained for DNA, dehydrated, and critical point dried (CPD). After mounting the cells were coated with gold. The specimens were brought into the vacuum chamber of the combined microscope and individual cells were studied with SEM and LM. Simultaneously DNA measurements were performed by means of the photometer unit attached to the microscope. It is shown in this study that DNA measurements of cells in the combined microscope give similar results when compared to DNA measurements of embedded cells performed with a conventional fluorescence microscope. Furthermore, it is shown that although the gold layer covering the LM/SEM specimens weakens the fluorescence signal, it does not interfere with the DNA measurements.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号