1.
The ozonation of wastewater supplied from a treatment plant (Samples A and B) and dye‐bath effluent (Sample C) from a dyeing and finishing mill and acid dye solutions in a semi‐batch reactor has been examined to explore the impact of ozone dose, pH, and initial dye concentration. Results revealed that the apparent rate constants were raised with increases in applied ozone dose and pH, and decreases in initial dye concentration. While the color removal efficiencies of both wastewater Samples A and C for 15 min ozonation at high ozone dosage were 95 and 97%, respectively, these were 81 and 87%, respectively at low ozone dosage. The chemical oxygen demand (COD) and dissolved organic carbon (DOC) removal efficiencies at several ozone dose applications for a 15 min ozonation time were in the ranges of 15–46% and 10–20%, respectively for Sample A and 15–33% and 9–19% respectively for Sample C. Ozone consumption per unit color, COD and DOC removal at any time was found to be almost the same while the applied ozone dose was different. Ozonation could improve the BOD5 (biological oxygen demand) COD ratio of Sample A by 1.6 times with 300 mg dm?3 ozone consumption. Ozonation of acid dyes was a pseudo‐first order reaction with respect to dye. Increases in dye concentration increased specific ozone consumption. Specific ozone consumption for Acid Red 183 (AR‐183) dye solution with a concentration of 50 mg dm?3 rose from 0.32 to 0.72 mg‐O3 per mg dye decomposed as the dye concentration was increased to 500 mg dm?3. © 2002 Society of Chemical Industry  相似文献   

2.
The aim of this study was to investigate the effectiveness of chemical oxidation by applying ozonation, combination of ozone and hydrogen peroxide and Fenton's processes for decolorization and residual chemical oxygen demand (COD) removal of biologically pretreated pulp and paper industry effluents. The batch tests were performed to determine the optimum operating conditions including pH, O3, H2O2, and Fe2+ dosages. H2O2 addition reduced the reaction times for the same ozone dosages; however combinations of ozone/hydrogen peroxide were only faintly more effective than ozone alone for COD and color removals. In the Fenton‘s oxidation studies, the removal efficiencies of COD, color and ultraviolet absorbance at 254 nm (UV254) for biologically treated pulp and paper industry effluents were found to be about 83, 95, and 89%, respectively. Experimental studies indicated that Fenton oxidation was a more effective process for the reduction of COD, color, and UV254when compared to ozonation and ozone/hydrogen peroxide combination. Fenton oxidation was found to have less operating cost for color removal from wastewater per cubic meter than the cost for ozone and ozone/hydrogen peroxide applications.  相似文献   

3.
This work aims to analyze the contribution of H2O2 on ozonation of Sulfamethoxazole (SMX). A single ozonation was able to totally remove SMX. TOC and COD depletion rates after a transferred ozone dose of 60 mg/L was related to the formation and decomposition of H2O2. An increase on O3 gas inlet concentration from 10 g/m3 to 20 g/m3 improved COD abatement from 11% to 36%. When the presence of H2O2 at the beginning of ozonation was tested, it was verified that COD and TOC degradation were enhanced, attaining maximum values of 76% and 32%, respectively, when compared with 35% and 15% reached in a single ozonation.  相似文献   

4.
Wastewaters derived from a textile factory and an industrial park were subjected to treatment with ferric chloride coagulation; ozonation; ferric chloride pre-coagulation/Fenton-based process/lime post-coagulation; Fenton-based process/lime post-coagulation; and ferric chloride pre-coagulation/ozonation. Schemes with the Fenton-based process proved the most efficient for treatment of both wastewater samples. The characteristics of wastewater samples treated by a Fenton-based process at H2O2/COD weight ratio 0.5:1 complied with the discharge limits stated by regulations for wastewater directed to local sewerage. The Fenton-based process/lime post-coagulation scheme proved more efficient than ferric chloride pre-coagulation/Fenton-based process/lime post-coagulation system. The increase of H2O2/COD weight ratio to 2:1 resulted in 5 and 10% of residual COD and DOC, respectively. All studied processes and combined physicochemical treatment schemes, except single ozonation, resulted in toxicity reduction and biodegradability improvement in both wastewater samples. The operational costs of applied treatment schemes were calculated and indicated the Fenton-based process schemes as the most feasible and cost-effective.  相似文献   

5.
The chemical treatment of cork‐processing wastewater by ozonation, alone and in combination with hydrogen peroxide and UV radiation was investigated. A reduction of the chemical oxygen demand (COD) ranging from 42% to 76% was obtained during ozonation after 3 h of reaction, depending on the experimental conditions. The additional presence of hydrogen peroxide and UV radiation enhanced the efficiency of the ozonation treatment due to the contribution of the OH radicals formed in the decomposition of ozone. Thus, final reductions of the COD higher than 90% and a complete elimination of phenolic compounds and absorbance at 254 nm were achieved in both Advanced Oxidation Processes (AOPs), O3/H2O2 and O3/UV. Therefore the effluent resulting from the ozonation treatments can be reused in the cork‐processing industry. In a second step, the chemical treatment was conducted by means of UV radiation alone and by the action of hydroxyl radicals, which were generated by the following AOPs: UV/H2O2, Fenton's reagent, and photo‐Fenton system. The single photochemical process resulted in 9% of the organic matter present being removed, while the AOPs significantly enhanced this reduction with values in the range 20–75%. Kinetic studies for both groups of treatments were performed, and apparent kinetic rate constants were evaluated. In the ozone‐based experiments, the rate constants ranged from 1846 to 10922 dm3 mol?1 O3 h?1, depending on the operating conditions. In the oxidation experiments using oxidants other than ozone, the rate constants varied between 0.06 and 1.19 h?1. Copyright © 2004 Society of Chemical Industry  相似文献   

6.
An economical method was proposed to develop an efficient alumina-supported manganese (Mn) and copper (Cu) oxides (Mn-Cu-O/Al2O3) catalyst with a high surface area, 184.06 cm2 g?1. The catalyst was utilized for degradation refinery wastewater by heterogeneous catalytic ozonation. The effects of various operating variables including pH, ozone and catalyst dosages, and temperature were systematically investigated in detail to obtain the optimized conditions for accelerated degradation of refinery wastewater. The optimum values were as follows: ozone dose 50.0 mg L?1, catalyst dose 3.0 g L?1, initial pH = 6.8, T = 17 °C. Refinery wastewater samples were analyzed by chemical oxygen demand (COD) and the results indicated that kinetics of COD followed a pseudo–first-order degradation. Moreover, hydroxyl radical mechanism rather than absorption was proposed, indicating that the surface hydroxyl groups were the active sites that played a significant role in catalytic ozonation.  相似文献   

7.
Effluent from the Pa?aköy Wastewater Treatment Plant was oxidized by using O3 and O3/H2O2. DOC, COD, UV254, total coliform, dissolved ozone and some endocrine disrupting compounds were monitored during oxidation. Results showed that O3 provided superior disinfection, however, lower reductions in DOC, COD and endocrine disrupting compounds were exhibited compared to O3/H2O2. The highest removal efficiency of DOC, COD and endocrine disrupting compounds were achieved at 0.5 molar ratio of O3/H2O2. The benefit of H2O2 addition for advanced oxidation reduced significantly when the mole ratio was increased to 2. Therefore, the mole ratio of H2O2 to O3 is a critical parameter for the design of wastewater oxidation by O3/H2O2.  相似文献   

8.
The combination of ozonation with UV irradiation can remove Tropaeolin O (AO6) and its by-products effectively and completely. The ozone dose affects the rate of decolorization, AO6 species removal, and dissolved organic carbon (DOC) reduction significantly. After 240 minutes of ozonation, the average DOC removal efficiency (ηDOC) for O3 alone was about 0.79, while ηDOC for O3/UV was 1.0. The average DOC removal rate was low at early stage of ozonation due to decolorization and low DOC. At later stage of ozonation, average DOC removal rate decreases because of the formation of persistent intermediates. The ozone consumption was consistent with ηDOC. The ratio of ozone consumption to ozone applied decreased from 14 to 12% when ηDOC < 40% because the decolorization in the early stage of the ozonation of AO6 may consume a relatively large amount of ozone. It was found that NO2, NO, CO2, and small amount of SO2 was detected in the off-gas. The effective concentration (EC50) increased from 23.48% to 100%, suggesting that the toxic reduction was achieved, and O3/UV system was superior to O3 alone system  相似文献   

9.
The advanced chemical oxidation of raw and biologically pretreated textile wastewater by (1) ozonation, (2) H2O2 /UV − C oxidation and (3) sequential application of ozonation followed by H2O2 /UV − C oxidation was investigated at the natural pH values (8 and 11) of the textile effluents for 1 h. Analysis of the reduction in the pollution load was followed by total environmental parameters such as TOC, COD, UV–VIS absorption kinetics and the biodegradability factor, fB. The successive treatment combination, where a preliminary ozonation step was carried out prior to H2O2 /UV − C oxidation without changing the total treatment time, enhanced the COD and TOC removal efficiency of the H2O2 /UV − C oxidation by a factor of 13 and 4, respectively, for the raw wastewater. In the case of biotreated textile effluent, a preliminary ozonation step increased COD removal of the H2O2 /UV − C treatment system from 15% to 62%, and TOC removal from 0% to 34%. However, the sequential process did not appear to be more effective than applying a single ozonation step in terms of TOC abatement rates. Enhancement of the biodegradability factor (fB) was more pronounced for the biologically pretreated wastewater with an almost two‐fold increase for the optimized Advanced Oxidation Technologies (AOTs). For H2O2 /UV − C oxidation of raw textile wastewater, apparent zero order COD removal rate constants (kapp), and the second order OH· formation rates (ri) have been calculated. © 2001 Society of Chemical Industry  相似文献   

10.
The efficiency and cost‐effectiveness of H2O2/UV for the complete decolorization and mineralization of wastewater containing high concentrations of the textile dye Reactive Black 5 was examined. Oxidation until decolorization removed 200–300 mg g?1 of the dissolved organic carbon (DOC). The specific energy consumption was dependent on the initial dye concentration: the higher concentration required a lower specific energy input on a weight basis (160 W h g?1 RB5 for 2.1 g L?1 versus 354 W h g?1 RB5 for 0.5 g L?1). Biodegradable compounds were formed, so that DOC removal could be increased by 30% in a following biological stage. However, in order to attain 800 mg g?1 overall mineralization, 500 mg g?1 of the DOC had to be oxidized in the H2O2/UV stage. A cost analysis showed that although the capital costs are much less for a H2O2/UV stage compared to ozonation, the operating costs are almost double those of ozonation. Thus, while H2O2/UV can compete with ozonation when the treatment goal only requires decolorization, ozonation is more cost‐effective in this case when mineralization is desired. Copyright © 2006 Society of Chemical Industry  相似文献   

11.
The continuous treatment of domestic wastewater by an activated sludge process and by an integrated biological–chemical (ozone) oxidation process were studied in this work. Chemical oxygen demand (COD), biochemical oxygen demand (BOD), absorbance at 254 nm (UV254) and nitrogenous compound content were the parameters followed in order to evaluate the performance of the two processes. Experimental data showed that both UV254 and COD reductions are improved in the combined biological–chemical oxidation procedure. Thus, reductions of 59.1% and 37.2% corresponding to COD and UV254, respectively were observed after the biological process (hydraulic retention time = 5 h; mixed liquor volatile suspended solids concentration = 3142 g m−3) compared with 71.0% and 78.4% obtained when a post‐ozonation step ( D O3 = 41.7 g m−3) was included. During conventional activated sludge treatment, appropriate nitrification levels are only achieved with high hydraulic retention time and/or biomass concentration. Ozonation after the secondary treatment, however, allows improved nitrogen content reduction with total nitrite elimination. Post‐ozonation also leads to a higher biodegradability of the treated wastewater. Thus, the ultimate BOD/COD ratio goes from 0.16 after biological oxidation to 0.34 after post‐ozonation with 41.7 g O3 m−3. © 1999 Society of Chemical Industry  相似文献   

12.
Several advanced oxidation processes for the destruction of cyanide contained in waste waters from thermoelectric power stations of combined‐cycle were studied. Thus, oxidation processes involving ozonation at basic pH, ozone/hydrogen peroxide, ozone/ultraviolet radiation and ozone/hydrogen peroxide/ultraviolet radiation have been carried out in a semi‐batch reactor. All these methods showed that total cyanide can be successfully degraded but with different reaction rates, and the decrease in the total cyanide concentration can be described by pseudo‐first order kinetics. The influence of pH and initial concentration of hydrogen peroxide was studied to find the optimal conditions of the oxidation process. Experimental results of the single ozone treatment indicated that total cyanide is destroyed more rapidly at higher pH (12), while ozonation combined with H2O2 and/or UV is faster at pH 9.5. The optimum concentration of H2O2 was 20.58 × 10?2 M because an excess of peroxide decreases the reaction rate, acting as a radical scavenger. The total cyanide degradation rate in the O3/H2O2(20.58 × 10?2 M ) treatment was the highest among all the combinations studied. However, COD reduction, in the processes using UV radiation such as O3/UV or O3/H2O2/UV was about 75%, while in the processes with H2O2 and/or O3/H2O2 was lower than 57% and was insignificant, when using ozone alone. Copyright © 2003 Society of Chemical Industry  相似文献   

13.
The post-treatment of composting leachate via an ozonation process in laboratory scale was studied in batch mode. According to the experiments, the COD removal was 47% after 30 min of ozonation via 0.4 g/h ozone (equivalent to 2.8 mg O3/mg COD removed) at pH 9. In this circumstance, the removal of color and turbidity was also 86% and 89%, respectively. Increasing the ozone mass flow rate higher than 0.4 g/h had no considerable effect on the process variables. However, increasing the reaction time had a significant effect on both the removal of color and on COD of the leachate. Experimental data indicated that complete removal of color and 51% removal of COD were achieved after about 40 min of ozonation via 0.4 g/h ozone (equivalent to 3.3 mg O3/mg COD removed). The ozone consumption rate increased as the reaction progressed and reached 4.1 mg O3/mg COD removed after 60 min.  相似文献   

14.
The current study focused on treatment of phenolic wastewater using an integrated process – dosing of ozone directly to activated sludge. The main goal was to analyze the effect of ozonation on viability of activated sludge in different systems – activated sludge in distilled water and activated sludge in wastewater. Two viability detection methods, oxygen uptake (OUR) rate and adenosine-5'-triphosphate measurement (ATP), were compared. The linear correlation between ATP and OUR measurements in studied range was found to be good (r2 = 0.90). In case of ozonation of activated sludge in wastewater, ozone doses up to 42 mgO3·gMLVSS?1 did not influence the viability of sludge. In addition, contrary to ozonation of sludge in distilled water, soluble COD was reduced by 15.6% (at ozone dose of 42 mgO3·gMLVSS?1).  相似文献   

15.
The present study investigates the decomposition of N-Methyl-2-Pyrolidone (NMP) using conventional ozonation (O3), ozonation in the presence of UV light (UV/O3), hydrogen peroxide (O3/H2O2), and UV/H2O2 processes under various experimental conditions. The influence of solution pH, ozone gas flow dosage, and H2O2 dosage on the degradation of NMP was studied. All ozone-based advanced oxidation processes (AOPs) were efficient in alkaline medium, whereas the UV/H2O2 process was efficient in acidic medium. Increasing ozone gas flow dosage would accelerate the degradation of NMP up to certain level beyond which no positive effect was observed in ozonation as well as UV light enhanced ozonation processes. Hydrogen peroxide dosage strongly influenced the degradation of NMP and a hydrogen peroxide dosage of 0.75 g/L and 0.5 g/L was found to be the optimum dosage in UV/H2O2 and O3/H2O2 processes, respectively. The UV/O3 process was most efficient in TOC removal. Overall it can be concluded that ozonation and ozone-based AOPs are promising processes for an efficient removal of NMP in wastewater.  相似文献   

16.
This research deals with the decolorization of synthetic wastewater, prepared with the acid 1:2 metal-complex textile dye C.I. Acid Blue 193, using the ozonation (O3) and H2O2/O3 processes. To minimize the number of experiments, they were performed using the 2k factorial design. Five influential parameters were examined: initial dye concentration, ozone flow rate, initial pH value, decolorization time and H2O2 addition. The decolorization efficiency was 95% in 20 minutes (pH = 7; O3 flow rate of 2 g/L.h) and a higher increase in the toxicity after the ozonation process (39%) indicates the formation of carcinogenic by-products. According to the variance test analysis, the initial dye concentration, the ozone flow rate, the initial pH value and the decolorization time and their first- and second-order interactions are significant, while the H2O2 addition was not important with respect to the discussed range. With the help of these significant factors a regression model was constructed and the adequacy of the model was checked. The obtained regression polynomial was used to model the relation between the absorbance and the influential parameters by fitting the response surface. This response surface may be used to predict the absorbance result from a set of influential parameters, or it can be rearranged in such a way as to predict the set of process decolorization parameters necessary to reduce the absorbance of wastewater with the given initial dye concentration, below the prescribed limit. It is also shown that the 2k factorial design can be suitable for predicting the operating expenses of the ozonation.  相似文献   

17.
The treatment of a segregated textile wastewater containing reactive dyes was investigated in two continuous‐flow process trains using ozonation and biological processes. The degree of decolorization and dissolved organic carbon (DOC) removal achieved by ozonation followed by aerobic treatment (two‐stage) was compared with that found when an anaerobic and aerobic pretreatment was added (four‐stage). Although the biological pretreatment reduced color by ~70%, similar amounts of ozone were required in both trains to achieve high degrees of overall removal of color and DOC. In both trains, ozonation increased biodegradability in the following aerobic reactor, however, in order to reach ~80% overall DOC removal, a specific ozone absorption (A*) of ~6 gO3 gDOCo?1 was required and >50% of the DOC was mineralized in the ozone reactor. A comparison of cost estimates based on investment and operating costs for the process alternatives showed that a four‐stage train would reduce costs only if it enabled a decrease in A* to less than 2 gO3 gDOCo?1. Difficulties in comparing treatment processes for segregated vs full‐stream wastewaters are discussed. Copyright © 2003 Society of Chemical Industry  相似文献   

18.
Hydroxyl radical (HO?) production during ozonation of municipal wastewater was investigated with and without liquid or solid-phase promoters. For liquid-phase promoters, an “ozone dose threshold” was observed, below which addition of H2O2 yielded no discernible increase in the rate of HO? production. This threshold occurs because ozonation of bulk organics in wastewater promotes HO? due to the presence of ambient promoters. Although solid-phase catalysts are reported to promote oxidation of contaminants, ozonation of effluent over TiO2 or GAC was no more effective on trace organic removal than over inert surfaces.  相似文献   

19.
Properties of activated sludge during ozonation were analyzed. The structure and surface characteristics altered with the increase of ozone dosage. At low ozone dosage, the floc structure was completely dismantled. Floc fragments reformed through reflocculation at an ozone dosage greater than 0.20 g O3·g?1 mixed liquor suspended solids (MLSS). Inactivation of microorganisms in the activated sludge mixture was caused by ozonation. Microbial growth decreased by up to 65% compared to the control. Simultaneously, 92.5% of nucleotide and 97.4% of protein in microbial cells of the sludge were released. Organic substance, nitrogen and phosphorus were released from the sludge during the ozonation process. The initial value of soluble chemical oxygen demand (SCOD) was 72 mg·L?1. When the ozone dosage was 0.12 g O3·g?1 MLSS, the value of SCOD rapidly reached 925 mg·L?1, increased by almost 12-fold. Simultaneously, 54.7% of MLSS was reduced. The composition of MLSS was changed, indicating that the inner water of cells and volatile organic substance decreased during the ozonation process.  相似文献   

20.
The objective of this study was to compare the efficiency of O3/granular activated carbon (GAC) to enhance ozone transformation into ·OH radicals, with the common advanced oxidation processes (O3/OH?, O3/H2O2). The results obtained with model systems under the given experimental conditions showed that the system O3/OH? (pH 9) and O3/H2O2 (pH 7, [H2O2] = 1·10?5 M) are more efficient than O3/GAC (pH 7, [GAC] = 0.5 g/L) to enhance ozone transformation into ·OH radicals. However, in Lake Zurich water the O3/GAC process has a similar efficiency as O3/H2O2 for ozone transformation into ·OH radicals. The results also show that the presence of GAC during Lake Zurich water ozonation leads to (i) removal of hydrophilic and hydrophobic micropollutants, (ii) reduction of the concentration of CO3 2?/HCO3 ?, and (iii) decrease of the concentration of dissolved organic carbon (DOC) present in the system.  相似文献   