首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Volatile organic compounds (VOC) in office buildings originate from multiple sources, such as outdoor air, building materials., occupants, office supplies, and office equipment. Many of the VOC found in office buildings are also present in environmental tobacco smoke (ETS), e.g., benzene, toluene, formaldehyde. Measurements made to date in office buildings have been interpreted by some to imply that the contributions of ETS to VOC exposures in office buildings are small. We have made a first order estimate of the contributions of ETS to VOC concentrations based on the VOC content of ETS and a time-dependent mass-balance model. Four different ventilation-infiltration scenarios were modelled for a typical office building. The results indicate that ETS can contribute significantly to total indoor levels of VOC in office buildings, even under moderate ventilation conditions. Ranges of concentrations for three of the four modelled scenarios substantially overlapped measured ranges of the compounds in office buildings. Average daytime concentrations of benzene from ETS, for example, for three of the four modelled scenarios, ranged from 2.7 to 6.2 μg m?3, compared to reported measurements of 1.4 to 8.1 μg m?3 for four office buildings. Under a “worst reasonable” case scenario, the average modelled ETS-contributed concentration of benzene was 33.9 μg m?3 for a 40-hour work week.  相似文献   

2.
A review is presented of investigations of volatile organic compound (VOC) concentrations in indoor air of buildings of different classifications (dwellings, offices, schools, hospitals) and categories (established, new and complaint buildings). Measured concentrations obtained from the published literature and from research in progress overseas were pooled so that VOC concentration profiles could be derived for each building classification/category. Mean concentrations of individual compounds in established buildings were found to be generally below 50 μg/m3, with most below 5 μg/m3. Concentrations in new buildings were much greater, often by an order of magnitude or more, and appeared to arise from construction materials and building contents. The nature of these sources and approaches to reduce indoor air concentrations by limiting source VOC emissions is discussed. Total VOC (TVOC) concentrations were substantially higher than concentrations of any individual VOCs in all situations, reflecting the large number of compounds present, but interpretation of such measurements was limited by the lack of a common definition for TVOC relevant to occupant exposure.  相似文献   

3.
Exposure to elevated levels of certain volatile organic compounds (VOCs) in households has been linked to deleterious health effects. This study presents the first large-scale investigation of VOC levels in 169 energy-efficient dwellings in Switzerland. Through a combination of physical measurements and questionnaire surveys, we investigated the influence of diverse building characteristics on indoor VOCs. Among 74 detected compounds, carbonyls, alkanes, and alkenes were the most abundant. Median concentration levels of formaldehyde (14 μg/m3), TVOC (212 μg/m3), benzene (<0.1 μg/m3), and toluene (22 μg/m3) were below the upper exposure limits. Nonetheless, 90% and 50% of dwellings exceeded the chronic exposure limits for formaldehyde (9 μg/m3) and TVOC (200 μg/m3), respectively. There was a strong positive correlation among VOCs that likely originated from common sources. Dwellings built between 1950s and 1990s, and especially, those with attached garages had higher TVOC concentrations. Interior thermal retrofit of dwellings and absence of mechanical ventilation system were associated with elevated levels of formaldehyde, aromatics, and alkanes. Overall, energy-renovated homes had higher levels of certain VOCs compared with newly built homes. The results suggest that energy efficiency measures in dwellings should be accompanied by actions to mitigate VOC exposures as to avoid adverse health outcomes.  相似文献   

4.
本文对上海市20户毛坯房(23个自然间)和95户精装房(133个自然间)进行了甲醛、氨、苯、TVOC和氡浓度测定,结果显示毛坯房5项指标均未出现超标,精装房室内空气污染较为严重,除氨和氡外,甲醛、苯和TVOC均出现超标,超标率分别为33.4%、2.6%和53.2%。通过对TVOC的组分浓度占比分析,乙酸丁酯、二甲苯和乙苯的浓度之和占约23%,未识别物质平均浓度占比超过8种标准物质成分总和,达到了74.49%。  相似文献   

5.
李文迪 《住宅科技》2011,31(12):30-33
选取上海地区82间办公室和48户住宅,以《室内空气质量标准》为检测和评价依据,以室内空气中的甲醛、TVOC和苯作为代表污染物,对其浓度水平进行了分析.从中发现目前民用建筑室内空气质量超标情况普遍,除客厅污染物超标率偏低外,厨房和书房中甲醛的超标率较高,书房中TVOC的超标率最高,卧室中苯的超标率最高.同时根据目前检测指标的选取情况发现大多数居民对于室内空气污染整体认识还需加强.  相似文献   

6.
Secondhand electronic cigarette (e-cigarette) aerosol (SHA) might impair indoor air quality and expose bystanders. This study aims to investigate exposure to SHA in controlled conditions of enclosed settings simulating real-world scenario. An experiment was performed in a car and in a room, in which SHA was generated during a 30-minute ad libitum use of an e-cigarette. The experiment was replicated on five consecutive days in each setting. We measured PM2.5, airborne nicotine concentrations, and biomarkers of exposure to SHA, such as nicotine metabolites, tobacco-specific nitrosamines, propylene glycol, and glycerol in bystanders’ saliva samples before, during, and after the exposure period. Self-reported health symptoms related to exposure to SHA were also recorded. The results showed that the highest median PM2.5 concentration was recorded during the exposure period, being 21 µg/m3 in the room setting and 16 µg/m3 in the car setting—about twofold increase compared to the baseline. Most concentrations of the airborne nicotine and all biomarkers were below the limit of quantification in both settings. Bystanders in both settings experienced some short-term irritation symptoms, expressed as dry throat, nose, eyes, and phlegm. In conclusion, short-term use of an e-cigarette in confined spaces increased indoor PM2.5 level and caused some irritation symptoms in bystanders.  相似文献   

7.
Monitoring of human reactions to the emission of formaldehyde and volatile organic compounds (VOC) from four commonly used building materials was carried out. The building materials were: a painted gypsum board, a rubber floor, a nylon carpet, and a particle board with an acid-curing paint. The exposures were performed in climate chambers. The air quality was quantified on the decipol scale by a trained panel, measurements of formaldehyde and VOC being performed simultaneously. The irritating potency of the materials was measured by a mouse bioassay. The VOC measurements showed several malodorants and irritants. Some abundant VOC identified in the head-space analyses were absent in the climate chamber air. The rubber floor and the nylon carpet exhibited a marked increase in decipols compatible with a number of odorous VOC identified in the air. A high formaldehyde concentration (minimum 743μg/m3) was measured for the particle board coated with an acid-curing paint. This was not reflected by a corresponding relatively high decipol value but a long-lasting irritating potency was observed in the mouse bioassay. TVOC sampled on Tenax and expressed in mass per volume as well as in molar concentration, and decipol evaluation both have limitations and should be used with caution as indicators of (perceived) indoor air quality. Eye irritation expressed by means of the eye index reflecting the tear film quality index (comprised of break-up time, foam formation, thickness of the precorneal lipid layer of the tear film, and epithelial damage) was found to be insensitive to formaldehyde and a VOC mixture but sensitive to TVOC concentrations of 1–2 mg/m3. Lipophilic VOC may be the cause of reduced tear film quality by destabilization of the lipid multilayer of the tear film.  相似文献   

8.
In retail stores, workers are constantly exposed to new manufactured goods. The issue of the exposure of retail workers to volatile organic compounds (VOCs) should clearly be considered. Therefore, this study provides data regarding VOC concentrations in ten French retail stores. The stores were chosen to represent various products: sports goods, shoes and leather, furniture, car equipment, bazaars, online-sales storage, clothes, books, DIY (do-it-yourself), and household appliances. VOCs and aldehydes were actively sampled on the same day in five to seven locations per building and outdoors. Toluene and formaldehyde were omnipresent with indoor concentrations reaching 252 and 53 µg/m3, respectively. The car equipment store, followed by clothing, shoes, and leather, and DIY stores showed the worst indoor air quality. High concentrations were measured, for example, the maximum α-pinene concentration in the furniture and DIY stores was 364 and 141 µg/m3, respectively, and the heptane concentration in the car equipment store reached 1,316 µg/m3. Two VOCs classified as toxic to reproduction were measured: hexane in the car equipment store and the bazaar, and dimethylformamide in the sports goods store. This study shows some disparities in the indoor concentrations among different locations in the same store, particularly between sales and storage areas.  相似文献   

9.
Concentrations of total volatile organic compounds (TVOC) exceeding 1 mg/m3 have been implicated in the Sick Building Syndrome. Very few measurements of TVOC have been made in homes and buildings in the United States. However, stored gas chromatography-mass spectrometry (GC-MS) data on 12-hour average values of individual VOCs from 750 homes and 10 buildings were available from EPA's Total Exposure Assessment Methodology (TEAM) Studies (1981-88). An initial study to determine the feasibility of obtaining a TVOC value from stored GC/MS data showed that TVOC estimates could be obtained with adequate precision. Therefore TVOC values were calculated for about 2700 personal, indoor, and outdoor air samples collected in the TEAM Studies. More than half of the personal and indoor air samples had TVOC levels exceeding 1 mg/m3, compared to only about 10% of the outdoor air samples. However, these calculated values may not be directly comparable with values determined using different sampling and analytical techniques. Nonetheless, since all samples were collected on Tenax cartridges, which (like all sorbents) adsorb only a portion of the organic chemicals in the air, these values are likely to be underestimates of the total volatile organic loading.  相似文献   

10.
Nail technicians are exposed to volatile organic compounds (VOCs) from nail products, but no studies have previously measured VOC biomarkers for these workers. This study of 10 nail technicians aimed to identify VOCs in nail salons and explore relationships between air concentrations and biomarkers. Personal and area air samples were collected using thermal desorption tubes during a work shift and analyzed using gas chromatography/mass spectrometry (GC/MS) for 71 VOCs. Whole blood samples were collected pre‐shift and post‐shift, and analyzed using GC/MS for 43 VOCs. Ventilation rates were determined using continuous CO2 measurements. Predominant air VOC levels were ethyl methacrylate (median 240 µg/m3), methyl methacrylate (median 205 µg/m3), toluene (median 100 µg/m3), and ethyl acetate (median 639 µg/m3). Blood levels were significantly higher post‐shift than pre‐shift for toluene (median pre‐shift 0.158 µg/L and post‐shift 0.360 µg/L) and ethyl acetate (median pre‐shift <0.158 µg/L and post‐shift 0.510 µg/L); methacrylates were not measured in blood because of their instability. Based on VOCs measured in these seven nail salons, we estimated that emissions from Greater Boston area nail salons may contribute to ambient VOCs. Ventilation rates did not always meet the ASHRAE guideline for nail salons. There is a need for changes in nail product formulation and better ventilation to reduce VOC occupational exposures.  相似文献   

11.
《Building and Environment》1999,34(4):479-503
The main function of a mechanically ventilated office building is to provide a healthy and comfortable working environment for occupants, while maintaining minimum energy consumption. Twelve mechanically ventilated buildings were selected. They varied greatly in surface area, number of floors, occupant density, and building use. The indoor air quality, thermal comfort, energy consumption, and perception of occupants were investigated in these buildings. A total of 877 subjects participated in the questionnaire survey during the hot summer months of June, July, and August, and during the cold winter months of January, February, and March. The questions included in the questionnaire dealt with health, environmental sensitivity, work area satisfaction, personal control of the workstations environment, and job satisfaction. Measured parameters concerning the quality of indoor air included ventilation rate, concentration of TVOC, CO2, CO, RH, and formaldehyde. The thermal comfort parameters included room air, mean radiant, plane radiant asymmetry, and dew point temperatures, as well as air velocity and turbulence intensity. Monthly energy consumption data was also gathered for each building. Ventilation performance, in terms of air flow rate and indoor air quality, was compared with the ASHRAE Standard 62-89R (Ventilation for Acceptable Indoor Air Quality. Atlanta: American Society of Heating, Refrigerating, and Air Conditioning Engineers, Inc. U.S.A. [1]). The measured and calculated thermal environmental results were also compared with the ASHRAE Standard 55-92 (Thermal Environmental Conditions for Human Occupancy. Atlanta: American Society of Heating, Refrigerating, and Air Conditioning Engineers, Inc. U.S.A. [2]). CO2 and CO levels satisfied the recommended limits. The outdoor airflow rate was half that recommended in only one building. The formaldehyde and TVOC levels were moderately higher than suggested comfort levels. However, more than 56% of the occupants rated dissatisfaction with the indoor air quality. Only 63% of the indoor climatic observations fell within the ASHRAE Standard 55-92 summer comfort zone; 27% in the winter. However, only 69% of those surveyed agreed with the comfort zones. More symptoms were reported by workers who perceived IAQ to be poor. Positive relationships were observed between the job satisfaction and satisfaction with office air quality, ventilation, work area temperature, and ratings of work area environment. However, job dissatisfaction did not correlate with symptom reports. The occupants were more dissatisfied with IAQ when they preferred more air movement. In other words, the higher the perceived air movement, the greater the satisfaction with IAQ.  相似文献   

12.
Hotel housekeepers represent a large, low-income, predominantly minority, and high-risk workforce. Little is known about their exposure to chemicals, including volatile organic compounds (VOCs). This study evaluates VOC exposures of housekeepers, sources and factors affecting VOC levels, and provides preliminary estimates of VOC-related health risks. We utilized indoor and personal sampling at two hotels, assessed ventilation, and characterized the VOC composition of cleaning agents. Personal sampling of hotel staff showed a total target VOC concentration of 57 ± 36 µg/m3 (mean ± SD), about twice that of indoor samples. VOCs of greatest health significance included chloroform and formaldehyde. Several workers had exposure to alkanes that could cause non-cancer effects. VOC levels were negatively correlated with estimated air change rates. The composition and concentrations of the tested products and air samples helped identify possible emission sources, which included building sources (for formaldehyde), disinfection by-products in the laundry room, and cleaning products. VOC levels and the derived health risks in this study were at the lower range found in the US buildings. The excess lifetime cancer risk (average of 4.1 × 10−5) still indicates a need to lower exposure by reducing or removing toxic constituents, especially formaldehyde, or by increasing ventilation rates.  相似文献   

13.
Abstract Birch and grass pollen grains as well as pollen-derived small particles appear as potent allergens in the outdoor air during spring and summer. The occurrence of pollen allergens in indoor air, however, has not been studied in depth due to lack of suitable sampling and analytical methods. Herein, a recently reported “direct on sampling filter estimation” (DOSAFE) technique ( Acevedo et al., 1998 ) has been validated for quantification of pollen allergens in indoor air using two school rooms and two office rooms as experimental models. Using DOSAFE and polyclonal antibodies against water extracts of pollen from Betula pendula and Phleum pratense L, we found that indoor air of school and office rooms carried substantial amounts of pollen allergens, expressed as SQ units, predominantly occurring as particles with smaller diameters than the pollen grains. In one school room the indoor air birch pollen allergen concentrations increased from 242 to 403 SQ units/m3 over the sampling period although the corresponding outdoor air concentrations decreased from 350 to 90 SQ units/m3. Electrostatic air cleaning in one office room reduced its grass pollen allergen concentrations by more than 95% to 0.02–0.34 SQ units/m3 as compared to the control room.  相似文献   

14.
Measurements were taken in new US residences to assess the extent to which ventilation and source control can mitigate formaldehyde exposure. Increasing ventilation consistently lowered indoor formaldehyde concentrations. However, at a reference air exchange rate of 0.35 h?1, increasing ventilation was up to 60% less effective than would be predicted if the emission rate were constant. This is consistent with formaldehyde emission rates decreasing as air concentrations increase, as observed in chamber studies. In contrast, measurements suggest acetaldehyde emission was independent of ventilation rate. To evaluate the effectiveness of source control, formaldehyde concentrations were measured in Leadership in Energy and Environmental Design (LEED)‐certified/Indoor airPLUS homes constructed with materials certified to have low emission rates of volatile organic compounds (VOC). At a reference air exchange rate of 0.35 h?1, and adjusting for home age, temperature and relative humidity, formaldehyde concentrations in homes built with low‐VOC materials were 42% lower on average than in reference new homes with conventional building materials. Without adjustment, concentrations were 27% lower in the low‐VOC homes. The mean and standard deviation of formaldehyde concentration was 33 μg/m3 and 22 μg/m3 for low‐VOC homes and 45 μg/m3 and 30 μg/m3 for conventional.  相似文献   

15.
In indoor environments with high levels of air pollution, it is desirable to remove major sources of emissions to improve air quality. In order to identify the emission sources that contribute most to the concentrations of indoor air pollutants, we used passive flux samplers (PFSs) to measure emission rates of carbonyl compounds and volatile organic compounds (VOCs) from many of the building materials and furnishings present in a room in a reinforced concrete building in Tokyo, Japan. The emission flux of formaldehyde from a desk was high (125 μg/m2/h), whereas fluxes from a door and flooring were low (21.5 and 16.5 μg/m2/h, respectively). The emission fluxes of toluene from the ceiling and the carpet were high (80.0 and 72.3 μg/m2/h, respectively), whereas that from the flooring was low (9.09 μg/m2/h). The indoor and outdoor concentrations of formaldehyde were 61.5 and 8.64 μg/m3, respectively, and those of toluene were 43.2 and 17.5 μg/m3, respectively. The air exchange rate of the room as measured by the perfluorocarbon tracer (PFT) method was 1.84/h. Taking into consideration the area of the emission sources, the carpet, ceiling, and walls were identified as the principal emission sources, contributing 24%, 20%, and 22% of the formaldehyde, respectively, and 22%, 27%, and 14% of the toluene, respectively, assuming that the emission rate from every major emission sources could be measured. In contrast, the door, the flooring, and the desk contributed little to the indoor levels of formaldehyde (1.0%, 0.54%, and 4.1%, respectively) and toluene (2.2%, 0.31%, and 0.85%, respectively).  相似文献   

16.
In order to develop an early-warning biosensor system for predicting the impact on health of long-term and low-level exposure to indoor chemical compounds, e.g. volatile organic compounds (VOCs), we evaluated the potential for assessing indoor air quality using the biosensor system based on the swimming behavior of Japanese medaka (oryzias latipes) as an indicator of indoor air quality in the beginning. As a technology to dissolve chemical compounds into water efficiently, a micro bubble generator was introduced. The test chemical was formaldehyde which is a representative of chemical compounds existing indoors. The result of the measuring solubility of formaldehyde was that formaldehyde concentration in water was raised to 0.12 mg/L when 1.0 mg/m3 of formaldehyde in air was bubbled for approximately 44 h. The correlation between the 0.1 mg/L of formaldehyde in water, which is roughly equivalent to 0.83 mg/m3 of formaldehyde in air, and the swimming activities of medaka was investigated. The fish showed abnormal behavior compared to one under a control treatment, e.g. the body movement distance decreased and the duration time near the upper water column increased significantly. It was verified that it is possible to detect concentrations of formaldehyde of 0.83 mg/m3 in indoor air using this proposed biosensor system.  相似文献   

17.
Volatile organic compounds (VOCs) as a non-negligible aircraft cabin air quality (CAQ) factor influence the health and comfort of passengers and crew members. On-board measurements of carbonyls (short-chain (C1-C6)) and other volatile organic compounds (VOCs, long-chain (C6-C16)) with a total of 350 samples were conducted in 56 commercial airliner cabins covering 8 aircraft models in this study. The mean concentration for each individual carbonyl compound was between 0.3 and 8.3 μg/m3 (except for acrolein & acetone, average = 20.7 μg/m3) similar to the mean concentrations of other highly detected VOCs (long-chain (C6-C16), 97% of which ranged in 0–10 μg/m3) in aircraft cabins. Formaldehyde concentrations in flights were significantly lower than in residential buildings, where construction materials are known formaldehyde sources. Acetone is a VOC emitted by humans, and its concentration in flights was similar to that in other high-occupant density transportation vehicles. The variation of VOC concentrations in different flight phases of long-haul flights was the same as that of CO2 concentration except for the meal phase, which indicates the importance of cabin ventilation in diluting the gaseous contaminants, while the sustained and slow growth of the VOC concentrations during the cruising phase in short-haul flights indicated that the ventilation could not adequately dilute the emission of VOCs. For the different categories of VOCs, the mean concentration during the cruising phase of benzene series, aldehydes, alkanes, other VOCs (detection rate > 50%), and carbonyls in long-haul flights was 44.2 µg/m3, 17.9 µg/m3, 18.6 µg/m3, 31.5 µg/m3, and 20.4 µg/m3 lower than those in short-haul flights, respectively. Carbonyls and d-limonene showed a significant correlation with meal service (< 0.05). Unlike the newly decorated rooms or new vehicles, the inner materials were not the major emission sources in aircraft cabins. Practical Implications.
  • The on-board measurements of 56 flights enrich the VOC database of cabin environment, especially for carbonyls. The literature review of carbonyls in the past 20 years contributes to the understanding the current status of cabin air quality (CAQ).
  • The analysis of VOC concentration variation for different flight phases, flight duration, and aircraft age lays a foundation for exploring effective control methods, including ventilation and purification for cabin VOC pollution.
  • The enriched VOC data is helpful to explore the key VOCs of aircraft cabin environment and to evaluate the acute/chronic health exposure risk of pollutants for passengers and crew members.
  相似文献   

18.
This paper presents pollutant concentrations and performance data for code-required mechanical ventilation equipment in 23 low-income apartments at 4 properties constructed or renovated 2013-2017. All apartments had natural gas cooking burners. Occupants pledged to not use windows for ventilation during the study but several did. Measured airflows of range hoods and bathroom exhaust fans were lower than product specifications. Only eight apartments operationally met all ventilation code requirements. Pollutants measured over one week in each apartment included time-resolved fine particulate matter (PM2.5), nitrogen dioxide (NO2), formaldehyde and carbon dioxide (CO2) and time-integrated formaldehyde, NO2 and nitrogen oxides (NOX). Compared to a recent study of California houses with code-compliant ventilation, apartments were smaller, had fewer occupants, higher densities, and higher mechanical ventilation rates. Mean PM2.5, formaldehyde, NO2, and CO2 were 7.7 µg/m3, 14.1, 18.8, and 741 ppm in apartments; these are 4% lower, 25% lower, 165% higher, and 18% higher compared to houses with similar cooking frequency. Four apartments had weekly PM2.5 above the California annual outdoor standard of 12 µg/m3 and also discrete days above the World Health Organization 24-hour guideline of 25 µg/m3. Two apartments had weekly NO2 above the California annual outdoor standard of 30 ppb.  相似文献   

19.
Hairdressers are exposed to particulate matter (PM), a known air pollutant linked to adverse health effects. Still, studies on occupational PM exposures in hair salons are sparse. We characterized indoor air PM concentrations in three salons primarily serving an African/African American (AA) clientele, and three Dominican salons primarily serving a Latino clientele. We also assessed the performance of low-cost sensors (uRAD, Flow, AirVisual) by comparing them to high-end sensors (DustTrak) to conduct air monitoring in each salon over 3 days to quantify work shift concentrations of PM2.5, respirable PM (RPM), and PM10. We observed high spatial and temporal variability in 30-min time-weighted average (TWA) RPM concentrations (0.18–5518 μg/m3). Readings for the uRAD and AirVisual sensors were highly correlated with the DustTrak (R2 = 0.90–0.99). RPM 8-hour TWAs ranged from 18 to 383 µg/m3 for AA salons, and 9–2115 µg/m3 for Dominican salons. Upper 95th percentiles of daily RPM exposures ranged from 439 to 2669 µg/m3. The overall range of 30-min TWA PM2.5 and PM10 concentrations was 0.13–5497 and 0.36-,541 μg/m3, respectively. Findings suggest that hairdressers could be overexposed to RPM during an 8-hour shift. Additional comprehensive monitoring studies are warranted to further characterize temporal and spatial variability of PM exposures in this understudied occupational population.  相似文献   

20.
An alternative method of maintaining indoor air quality may be through the biofiltration of air recirculating within the structure rather than the traditional approach of ventilation. This approach is currently being investigated. Prior to its acceptance for dealing with volatile organic compounds (VOCs) and CO2, efforts were made to determine whether the incorporation of this amount of biomass into the indoor space can have an (negative) impact on indoor air quality. A relatively large ecologically complex biofilter composed of a ca. 10 m2 bioscrubber, 30 m2 of plantings and a 3,500 litre aquarium were established in a 160 m2 'airtight' room in a recently constructed office building in downtown Toronto. This space maintained ca. 0.2 air changes per hour (ACH) compared to the 15 to 20 ACH (with a 30% refresh rate) of other spaces in the same building. Air quality parameters of concern were total VOCs (TVOCs), formaldehyde and aerial spore counts. TVOC and formaldehyde levels in the biofilter room were the same or significantly less than other spaces in the building despite a much slower refresh rate. Aerial spore levels were slightly higher than other indoor spaces but were well within reported values for 'healthy' indoor spaces. Levels appeared to be dependent on horticultural management practices within the space. Most genera of fungal spores present were common indoors and the other genera were associated with living or dead plant material or soil. From these results, the incorporation of a large amount of biomass associated with indoor biofilters does not in itself lower indoor air quality.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号