首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 17 毫秒
1.
Many ways, tools and concepts have been developed to determine performance indicators and criteria for healthy and comfortable buildings, focusing in general on the prevention of health and comfort problems. Perhaps the most important observation in these ways, tools and concepts is the fact that because dose-response relations in general are incomplete, most indicators do not seem to be useful. A second observation is the fact that interactions occurring at different levels (at human level, parameters of the indoor environment and at building level) are not taken into account. Moreover, the timeframe taken is often static (at a certain point in time) and not dynamic. Comparing static performance indicators with a dynamic process (being exposed in a building) will therefore most likely result in a non-valid outcome. And last but not least it is observed that the perception of positive stimuli are in general not considered. There is a need for a different or at least an adapted approach towards evaluation of health and comfort of occupants in the indoor environment: an integrative multi-disciplinary approach taking account of positive and negative stimuli and concerned with “real” needs of people.  相似文献   

2.
This paper reports a study of the subjective preference to daylit indoor environment of a residential room using conjoint analysis, which is a highly reputable method used to analyze the mutual relationships among different attributes. Seven influential attributes were selected in the view of daylight performance assessment. They include ‘general brightness’, ‘desktop brightness’, ‘perceived glare’, ‘sunlight penetration’, ‘quality of view’, ‘user friendliness of shading control’ and ‘impact on energy’. Each of them has two levels. A total of eight combinations (profiles) of attributes with various levels were established by adopting fractional factorial design. Subjects were asked to rank-order the eight profiles according to their preference in terms of daylit environment of a residential room. The study aims at finding out the relative impact of the seven selected attributes to the overall daylight performance and seeking an organized assessment method for a residential daylit environment. Conjoint analysis found that the seven attributes have importance level in the order of ‘quality of view’, ‘general brightness’, ‘impact on energy’, ‘user friendliness of shading control’, ‘perceived glare’, ‘desktop brightness’ and ‘sunlight penetration’.  相似文献   

3.
Kerala is a strip of land on the southwest coast of India lying between Arabian Sea on the west and Western Ghats on the east. The traditional architecture of Kerala is known for its use of natural and passive methods for a comfortable indoor environment. However, it has not been proved by a detailed and quantitative evaluation method so far. A field study was thus conducted in the winter and summer periods to investigate the indoor environmental condition of a typical Kerala traditional residential building. The objective of the investigation was to understand the passive environment control system of Kerala traditional architecture by quantitative analysis of various thermal comfort parameters. It was done by continuously monitoring the indoor and outdoor conditions using a custom made instrument called “Architectural Evaluation System”. The results show that the natural and passive control system of Kerala traditional architecture provides comfortable indoor environment irrespective of the outdoor climatic conditions.  相似文献   

4.
The traditional architecture of Kerala, a state in India lying along its southwest coast, is known for its use of natural and passive methods for a comfortable indoor environment. Although there have been attempts to analyze the traditional architecture of Kerala, they were focused only on qualitative approach. An investigation was thus initiated by the authors to understand the passive environment control system of Kerala traditional architecture in providing better thermal comfort, by continuously monitoring thermal comfort parameters of a typical traditional residential building over a period of time. The inferences of the first phase of the investigation carried out during winter and summer seasons, lasting about half of the year have already been published. This paper illustrates the inferences of the second phase of the investigation that is carried out during the rainy season of the year. A comparative analysis with the results of the winter and summer periods is also incorporated. The investigation has revealed that, when the outside ambient temperature is below normal, the building system tries to maintain the indoor air temperature at a higher but comfortable level and when the outside temperature is above normal, the indoor is kept at a lower but comfortable level. It is found that a continuous gentle wind flow is maintained inside the building irrespective of the wind outside. The required level of thermal comfort is achieved by maintaining a balanced level of temperature and relative humidity along with a continuous and controlled airflow inside the building irrespective of seasons.  相似文献   

5.
Subjective experiments were conducted to evaluate the effects of humidity on human comfort and productivity under transient conditions from hot and humid environment to thermally neutral condition. Two climate chambers, “Chamber 1” and “Chamber 2”, adjoined each other were used for this study. Subjects were exposed to 30 °C/70%RH air in Chamber 1 for 15 min with 2.0 met of metabolic rate. Then they moved into Chamber 2, where 4 humidity conditions, 30, 40, 50 and 70%RH were examined. Air temperature was adjusted to keep SET* constant at 25.2 °C for all conditions. Subjects were exposed in Chamber 2 for 180 min performing 2 kinds of simulated office work.

Positive effects of low humidity on subjective pleasantness were found under transient condition at low humidity due to more evaporation from human body, while no significant difference in thermal sensation and humidity sensation among 4 relative humidity levels was obtained. Subjective performance was found to be at the same level under all conditions. However, subjects reported to be more tired at 70%RH after humidity step change.  相似文献   


6.
This work shows some of the results of a field study about environmental comfort investigations in classrooms. In this project thermal, acoustic, visual and air quality aspects were analysed in a number of classrooms—13 classrooms at four different high schools of the Provincia di Torino and four typical medium-sized university classrooms of the Politecnico di Torino, Italy. The investigations were carried out during the heating period. Both field measurements and subjective surveys were performed at the same time during the regular lesson periods.  相似文献   

7.
Subjective evaluation of Indoor Air Quality (subjective IAQ) reflects both building‐related and psychosocial factors, but their associations have rarely been studied other than on the individual level in occupational settings and their interactions have not been assessed. Therefore, we studied whether schools’ observed indoor air problems and psychosocial factors are associated with subjective IAQ and their potential interactions. The analysis was performed with a nationwide sample (N = 195 schools/26946 students) using multilevel modeling. Two datasets were merged: (i) survey data from students, including information on schools’ psychosocial environment and subjective IAQ, and (ii) data from school principals, including information on observed indoor air problems. On the student level, school‐related stress, poor teacher–student relationship, and whether the student did not easily receive help from school personnel, were significantly associated with poor subjective IAQ. On the school level, observed indoor air problem (standardized β = ?0.43) and poor teacher–student relationship (standardized β = ?0.22) were significant predictors of poor subjective IAQ. In addition, school‐related stress was associated with poor subjective IAQ, but only in schools without observed indoor air problem (standardized β = ?0.44).  相似文献   

8.
A wireless sensor network (WSN) is a group of sensors linked by wireless medium to perform distributed sensing tasks. WSNs have attracted a wide interest from academia and industry alike due to their diversity of applications, including home automation, smart environment, and emergency services, in various buildings. The primary goal of a WSN is to collect data sensed by sensors. These data are characteristic of being heavily noisy, exhibiting temporal and spatial correlation. In order to extract useful information from such data, as this paper will demonstrate, people need to utilise various techniques to analyse the data. Data mining is a process in which a wide spectrum of data analysis methods is used. It is applied in the paper to analyse data collected from WSNs monitoring an indoor environment in a building. A case study is given to demonstrate how data mining can be used to optimise the use of the office space in a building.  相似文献   

9.
The modern day practice does not give due respect to passive and natural environment control measures in buildings. With modern materials and technology, the buildings of present architectural style results in high energy consumption, in an attempt to provide thermal comfort indoors. The vernacular architecture at any place on the other hand has evolved through ages by consistent and continuous effort for more efficient and perfect solutions. The authors have conducted a qualitative analysis of the passive environment control system of vernacular residential architecture of Kerala that is known for ages for its use of natural and passive methods for a comfortable indoor environment. The orientation of building, internal arrangement of spaces, the presence of internal courtyard, use of locally available materials and special methods of construction, etc. have together created the indoor environment. A quantitative analysis was also carried out based on field experiments by recording thermal comfort parameters in a selected building. The study has provided positive results confirming that the passive environment control system employed in Kerala vernacular architecture is highly effective in providing thermal comfort indoors in all seasons.  相似文献   

10.
In the European research project OFFICAIR, a procedure was developed to determine associations between characteristics of European offices and health and comfort of office workers, through a checklist and a self‐administered questionnaire including environmental, physiological, psychological, and social aspects. This procedure was applied in 167 office buildings in eight European countries (Portugal, Spain, Italy, Greece, France, Hungary, the Netherlands, and Finland) during the winter of 2011–2012. About 26 735 survey invitation e‐mails were sent, and 7441 office workers were included in the survey. Among respondents who rated an overall comfort less than 4 (23%), ‘noise (other than from building systems)’, air ‘too dry’, and temperature ‘too variable’ were the main complaints selected. An increase of perceived control over indoor climate was positively associated with the perceived indoor environment quality. Almost one‐third of office workers suffered from dry eyes and headache in the last 4 weeks. Physical building characteristics were associated with occupants’ overall satisfaction (acoustical solutions, mold growth, complaints procedure, cleaning activities) and health (number of occupants, lack of operable windows, presence of carpet and cleaning activities). OFFICAIR project provides a useful database to identify stressors related to indoor environmental quality and office worker's health.  相似文献   

11.
The research presented in this paper shows that moisture transfer between indoor air and hygroscopic building structures can generally improve indoor humidity conditions. This is important because the literature shows that indoor humidity has a significant effect on occupant comfort, perceived air quality (PAQ), occupant health, building durability, material emissions, and energy consumption. Therefore, it appears possible to improve the quality of life of occupants when appropriately applying hygroscopic wood-based materials. The paper concentrates on the numerical investigation of a bedroom in a wooden building located in four European countries (Finland, Belgium, Germany, and Italy). The results show that moisture transfer between indoor air and the hygroscopic structure significantly reduces the peak indoor humidity. Based on correlations from the literature, which quantify the effect of temperature and humidity on comfort and PAQ for sedentary adults, hygroscopic structures can improve indoor comfort and air quality. In all the investigated climates, it is possible to improve the indoor conditions such that, as many as 10 more people of 100 are satisfied with the thermal comfort conditions (warm respiratory comfort) at the end of occupation. Similarly, the percent dissatisfied with PAQ can be 25% lower in the morning when permeable and hygroscopic structures are applied.  相似文献   

12.
Mineral-based turf has been used as a building material in Iceland for centuries. The vernacular Icelandic architecture is characterised by turf walls and sod roofs. This paper describes the historical development of the various archetypes of Icelandic turf farmhouses, researches the building techniques and materials applied, and qualifies the impact of the building properties on comfort and health of the former occupants. The study consisted of desk research, and a field study at the farmhouse of Glaumbær. In the wet and cold Icelandic climate, turf was an appropriate material that required its own building technology. The material was commonly available in settled areas of the island. Thick turf walls protected the residents against the harsh outdoor conditions, but had little effect on indoor air quality.  相似文献   

13.
The effect of filtration and ventilation on reduction of submicrometer particle concentration indoors was investigated in an office building. The air-handling system consisting of dry media filters and an air-conditioning unit, reduced particle concentration levels by 34%. The characteristics of indoor airborne particles were dominated by, and followed the pattern of, outdoor air, with vehicle combustion aerosols as the main pollutant. The ratio indoor/outdoor particle concentration varied between 14 and 26% for different sub-zones. The presence of significant source of particles indoors was not observed. A simple mathematical model predicting evolution of particles indoors is presented. The model, based on a particle number balance equation, was validated with experimental data and showed very good agreement between predicted and measured parameters.  相似文献   

14.
随着对住宅舒适性的要求越来越高,人们越来越关注住宅建筑室内声环境的质量。在影响室内声环境的多个因素中,给排水系统的影响是较大的。本文从给排水系统方面,分析论述了其对住宅室内声环境产生的影响、产生影响的原因以及噪声控制的方法。  相似文献   

15.
A comparative study of the occupant comfort (neutral) in a conventional high-rise office block and a contemporary environmentally-concerned building for Sheffield UK climate conditions was carried out. A questionnaire was designed for occupants to rate their workplace environment in terms of the thermal, visual, acoustic and overall perception and satisfaction level. The basic physical parameters were measured at the same time, e.g. air temperature, humidity, illuminance and sound level. It is inferred that (1) There is a noticeable difference between the conventional building and environmentally-concerned building in terms of their thermal and visual environment. (2) A clear distinction of the occupant sensation and satisfaction level towards their thermal and visual environment is presented between these two buildings. (3) The effect of basic physical variables on the occupants’ perception and satisfaction level becomes less significant when minimal standards are attained. (4) The acoustic satisfaction level however, was not perceived differently by the occupants of the two building types.  相似文献   

16.
Vast quantities of energy are consumed in heating and cooling to provide what are now regarded as acceptable standards of thermal comfort. In the UK as in a number of other countries, there is a real danger that responses in anticipation of global warming and climate change – including growing reliance on air-conditioning – will increase energy demand and CO2 emissions even further. This is an appropriate moment to reflect on the history and future of comfort, both as an idea and as a material reality. Based on interviews and discussions with UK policy makers and building practitioners involved in specifying and constructing what will become the indoor environments of the future, four possible scenarios are identified each with different implications for energy and resource consumption. By actively promoting debate about the indoor environment and associated ways of life, it may yet be possible to avoid becoming locked into social and technical trajectories that are ultimately unsustainable. The aim of this paper is to inspire and initiate just such a discussion through demonstrating that comfort is a highly negotiable socio-cultural construct.  相似文献   

17.
A new method is described in this article for selecting indoor temperature and indoor relative humidity to achieve minimum energy consumption for a required indoor thermal comfort level which is evaluated with indoor effective temperature. This method is derived from a central air-conditioning system and is based on our investigation that under a same indoor effective temperature, the system cooling load and the system energy consumption increase with an increase of indoor temperature. As such, energy consumption cannot be reduced with increasing indoor temperature for a given human thermal comfort level. In order to reduce energy consumption while keeping a same indoor thermal comfort level, indoor temperature and relative humidity may be determined with the proposed method described in this article. With the proposed method, a parameter variation study has also been conducted, which suggests that for a given indoor effective temperature, a combination of high indoor relative humidity and low indoor temperature be generally taken. The proposed method is based on the central air-conditioning system; yet it can be easily extended to other systems.  相似文献   

18.
What are the various ways in which evaluation of the several aspects of the indoor environment might combine to form an occupant's overall assessment of that environment? Data from an environmental survey of 26 offices in Europe (the Smart Controls and Thermal Comfort, or SCATs, project) are used. These show that dissatisfaction with one or more aspects of the indoor environment does not necessarily produce dissatisfaction with the environment overall. Conversely, satisfaction with one or more environmental aspect does not necessarily produce satisfaction with the total environment. Building occupants balance the good features against the bad to reach their overall assessment. Not all aspects are equally important in this subjective averaging process. Satisfaction with warmth and air quality is more important than satisfaction with the level of lighting or humidity. The relative importance of the various aspects differed from country to country, making it impossible to develop an internationally valid index to rate office environments by means of a single number. The best linear index constructed from the data failed to rank the indoor environments of the buildings in the correct order, as defined by the occupants' overall assessments. It is therefore wise to assess each of the several aspects separately rather than rely only on a combined index.  相似文献   

19.
Walk through questionnaires may be feasible tools to obtain data on the indoor environment in community studies. However, limited information is available regarding the reproducibility of the data obtained through these questionnaires. In this pilot study, two construction engineering students inspected ten dwellings twice by means of a standardized walk through questionnaire. The two engineering students inspected the dwellings independent of each other within two months. Time between the two visits varied between 14 and 40 days. The variables presented were based on information from the residents and inspection. The continuous variables recorded included number of rooms in the dwellings, room volume, length of filled shelves and textile area. The inter- and intra-observed variabilities were poorer for number of rooms and shelf factor than for the other variables. For the 3 of the 9 categorical variables based on inspection, the inter-observer comparison showed complete agreement with a kappa statistics of 1.0, these variables being condition of the window frames and construction of outside walls and roof. One of the categorical variables showed a kappa statistics of < 0.5, these variables being presence of basement and presence of condensation at windows. This study indicates a wide variation in observer variability between various items of a walk through questionnaire. Clear definitions of all the parts of the questionnaire are needed, as well as thorough training of observers.  相似文献   

20.
The aim was to develop and validate a standardized questionnaire - the Stockholm Indoor Environment Questionnaire (SIEQ). The validation procedure was based on sociological principles and test procedures for validation. The indicators of indoor environment are air quality, thermal climate, noise, and illumination. The indicators of health are symptoms comprised in the sick building syndrome (SBS). The questionnaire also contains questions about the apartment, individual behavior, and personal factors. The everyday language describing the building and its function was first obtained by qualitative personal interviews, then by standardized questions. The interview questionnaire was transformed into a postal self-administered questionnaire. The reduction of the questionnaire was based on correlation analysis. It was found that to obtain a good validity, general questions are not sufficient, but specific question on perceptions and observations are needed. Good test-retest agreement was found both on an area level, building level, and individually. For each indicator, a set of questions are constructed and validated. SIEQ has been used in several studies, and the results are presented in graphic problem profiles. Reference data has been calculated for the Stockholm area.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号