首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
The objective of this study was to develop an adaptive thermal comfort equation for naturally ventilated buildings in hot-humid climates. The study employed statistical meta-analysis of the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) RP-884 database, which covered several climatic zones. The data were carefully sorted into three climate groups including hot-humid, hot-dry, and moderate and were analyzed separately. The results revealed that the adaptive equations for hot-humid and hot-dry climates were analogous with approximate regression coefficients of 0.6, which were nearly twice those of ASHRAE and European standards 55 and EN15251, respectively. The equation using the daily mean outdoor air temperature had the highest coefficient of determination for hot-humid climate, compared with other mean temperatures that considered acclimatization of previous days. Acceptable comfort ranges showed asymmetry and leaned toward operative temperatures below thermal neutrality for all climates. In the hot-humid climate, a lower comfort limit was not observed for naturally ventilated buildings, and the adaptive equation was influenced by indoor air speed rather than indoor relative humidity. The new equation developed in this study can be applied to tropical climates and hot-humid summer seasons of temperate climates.  相似文献   

2.
This article investigates building thermal mass control of commercial buildings to reduce utility costs with a particular emphasis on the individual impacts of both adaptive comfort criteria and of heat waves. Recent changes in international standards on thermal comfort for indoor environments allow for adaptation to the weather development as manifested in comfort criteria prEN 15251.2005 and NPR-CR 1752.2005 relative to the non-adaptive comfort criterion ISO 7730.2003. Furthermore, since extreme weather patterns tend to occur more frequently, even in moderate climate zones, it is of interest how a building's passive thermal storage inventory responds to prolonged heat waves. The individual and compounded effects of adaptive comfort criteria and heat waves on the conventional and optimal operation of a prototypical office building are investigated for the particularly hot month of August 2003 in Freiburg, Germany. It is found that operating commercial buildings using adaptive comfort criteria strongly reduces total cooling loads and associated building systems energy consumption under conventional and building thermal mass control. In the case of conventional control, total operating cost reductions follow the cooling loads reductions closely. Conversely, the use of adaptive comfort criteria under optimal building thermal mass control leads to both lower and slightly higher absolute operating costs compared to the optimal costs for the non-adaptive ISO 7730. While heat waves strongly affect the peak cooling loads under both conventional and optimal building thermal mass control, total cooling loads, building energy consumption and costs are only weakly affected for both control modes. Passive cooling under cost-optimal control, while achieving significant total cost reductions of up to 13%, is associated with total energy penalties on the order of 1–3% relative to conventional nighttime setup control. Thus, building thermal mass control defends its cost saving potential under optimal control in the presence of adaptive comfort criteria and heat waves.  相似文献   

3.
ABSTRACT

Recent studies in primary schools highlight a need to develop the adaptive comfort model for schoolchildren in classrooms. This study investigates the application of the principal methods underlying the adaptive comfort theory for children relating thermal comfort indoors to the prevailing mean outdoor temperature. Children’s sensitivity to indoor temperature change are examined using data from a field study conducted in Iranian schools. This sensitivity is used to estimate the comfort temperatures in classroom situations with a minimum level of adaptation. Different metrics for the outdoor climate are employed to understand an expression of the climate which best predicts children’s comfort temperature. A sensitivity analysis is performed to derive the relation between indoor comfort and the climate that gives rise to the strongest correlation coefficient. Although the basic adaptive comfort relationships are applicable for children, the exponential method to calculate the prevailing mean with lower decay values leads to higher correlation with children’s comfort temperature. The slope of children’s comfort equation in relation to outdoor temperature is shown to be shallower than those of adults. Results indicate that children are more sensitive to temperature change within a single school day than across the overall survey period of several days.  相似文献   

4.
Based on building energy and indoor environment simulations, this study uses a recently developed method relying on Bayesian Network theory to estimate and compare the consequences for occupant performance and energy consumption of applying temperature criteria set according to the adaptive model of thermal comfort and the more conventional PMV model. Simulations were carried out for an example building with two configurations (with and without mechanical cooling) located in tropical, subtropical, and temperate climate regions. Even though indoor temperatures differed significantly between building configurations, especially in the tropical climate, the estimated performance differed only modestly between configurations. However, energy consumption was always lower in buildings without mechanical cooling, particularly so in the tropical climate.  相似文献   

5.
Sustainable low-energy office buildings attempt to harness the buildings architecture and physics to provide a high quality working environment with the least possible primary energy consumption. A promising approach to condition those buildings in summer employs the utilization of the building's thermal storage activated by natural heat sinks (e.g., ambient air, ground water or soil) through night ventilation or thermally activated building systems (TABS). However, a certain room temperature cannot be guaranteed as occupants may influence the room energy balance by window opening, internal heat gains or sun shading control. Between 2001 and 2005, monitoring campaigns were carried out over 2 or 3 years in 12 low-energy office buildings which are located in three different summer climate zones in Germany. These climate zones are defined as summer-cool, moderate and summer-hot. The weather at the building site and the room temperatures in several office rooms were monitored by different scientific teams. The raw data are processed for data evaluation using a sophisticated method to remove errors and outliers from the database and to identify the time of occupancy. The comfort in all office rooms in each building is evaluated separately. For data presentation, these separate comfort votes per office room are averaged using the median instead of the arithmetic mean in order not to overestimate extremely cold or hot room temperatures. A comfort evaluation in these 12 low-energy office buildings indicates clearly, that buildings which use only natural heat sinks for cooling provide good thermal comfort during typical and warm summer periods in Germany. However, long heat waves such as during the extreme European summer of 2003 overstrain passively cooled buildings with air-driven cooling concepts in terms of thermal comfort.  相似文献   

6.
This paper discusses thermal comfort inside residences of three cities in the hot-humid climate of central southern China. Only a few thermal comfort studies have been performed in hot-humid climates and none in Central Southern China. Field sampling took place in the summers of 2003 and 2004 by obtaining 110 responses to a survey questionnaire and measuring environmental comfort variables in three rooms in each of 26 residences. The objectives are to measure and characterize occupant thermal perceptions in residences, compare observed and predicted percent of dissatisfied and discern differences between this study and similar studies performed in different climate zones. Average clothing insulation for seated subjects was 0.54 clo with 0.15 clo of chairs. Only 48.2% of the measured variables are within the ASHRAE Standard 55-1992 summer comfort zone, but approximately 87.3% of the occupants perceived their thermal conditions acceptable, for subjects adapt to prevailing conditions. The operative temperature denoting the thermal environment accepted by 90% of occupants is 22.0–25.9°. In the ASHRAE seven-point sensation scale, thermal neutral temperature occurs at 28.6°. Preferred temperature, mean temperature requested by respondents, is 22.8°. Results of this study can be used to design low energy consumption systems for occupant thermal comfort in central southern China.  相似文献   

7.
Indoor thermal climate is an important issue affecting the health and productivity of building occupants. In the designing of commercial air-conditioning systems, it is believed that the conventional fixed temperature set point concept is limited because indoor comfort temperature depends on the business culture, such as the nature of activities and dress code of occupants, etc. Researchers have been interested in investigating adaptive temperature control for a realistic in-situ control of comfort. Unfortunately, those studies put great emphasis on energy saving opportunities and sometimes might result in thermal discomfort to individuals. This study argues that complaints of thermal discomfort from individuals, despite representing only a small portion of the population, should not be ignored and can be used to determine the temperature setting for a population in air-conditioned environment. In particular, findings of a new notion of Bayesian adaptive comfort temperature (BACT) in air-conditioned buildings in a humid and subtropical climate like Hong Kong are reported, and the adaptive interface relationship between occupants’ complaints of thermal discomfort and indoor air temperature is determined. This BACT algorithm is intended to optimise the acceptance of thermal comfort, as determined by physical measurements and subjective surveys.  相似文献   

8.
Sheng Zhang  Zhang Lin 《Indoor air》2020,30(5):1052-1062
Thermal adaptations, as feedbacks of occupants to physical stimuli, extend thermal comfort zone thereby reducing building energy consumption effectively. The rational approach models thermal comfort from the perspective of the body's heat balance, but is limited in explaining the thermal adaptations. The adaptive approach of modeling thermal comfort can fully account for the thermal adaptations, but ignores the body's heat balance. To improve thermal comfort prediction, this study proposes an adaptive-rational thermal comfort model, that is, an adaptive predicted mean vote with a variable adaptive coefficient (termed as arPMV). By linearly linking the negative feedback effects of the thermal adaptations to the ambient temperature according to the adaptive approach, the variable adaptive coefficient is linearly related to the reciprocal of the ambient temperature with two constants. The variable adaptive coefficient is determined by explicitly quantifying the two constants as the functions of the predicted mean vote, thermal sensation vote, and ambient temperature. The proposed arPMV is validated for naturally ventilated, air-conditioned, and mixed-mode buildings, with the mean absolute error and the robustness of the thermal sensation prediction reduced by 24.8%-83.5% and improved by 49.7%-83.4%, respectively.  相似文献   

9.
In earlier work [1], NIST developed a climate suitability analysis method to evaluate the potential of a given location for direct ventilative cooling and nighttime ventilative cooling. The direct ventilative cooling may be provided by either a natural ventilation system or a fan-powered economizer system. The climate suitability analysis is based on a general single-zone thermal model of a building configured to make optimal use of direct and/or nighttime ventilative cooling. This paper describes a new tool implementing this climate suitability methodology and its capability to consider an adaptive thermal comfort option and presents results from its application to analyze a variety of U.S. climates. The adaptive thermal comfort option has the potential to substantially increase the effectiveness of natural ventilation cooling for many U.S. cities. However, this impact is very dependent on the acceptable humidity range. If a dewpoint limit is used, the increase is significant for a dry climate such as Phoenix but much smaller for humid climates such as Miami. While ASHRAE Standard 55 does not impose a limit on humidity when using the adaptive thermal comfort option, the necessity of limiting humidity for other reasons needs to be considered.  相似文献   

10.
为研究上海地区人体热感觉和适应性热舒适现状,通过环境参数测量和问卷调查结合的方式来分析和探讨室内外气候条件、服装热阻、热感觉等关系。本文主要涉及自然通风建筑内人体热感觉和热中性温度随季节变化的关系。结果表明:在适应性热舒适研究中,人体中性温度与室外环境温度具有较强的相关性,得到的上海地区适应性热舒适模型可为适合我国自身特点的热舒适研究提供依据。  相似文献   

11.
《Building and Environment》2004,39(2):189-193
Various types of spaces are controlled for maintaining a desired comfort-condition level. Examples include buildings, automobiles, airplanes, and trains. The steady-state or longer-duration HVAC control is well established. However, situations are encountered where a rapid march towards a thermal space comfort level is required such as in the parked automobiles or in buildings where thermal mass is utilized for conserving energy. Many times design changes are proposed to improve the transient pull down in one zone but that could significantly affect the transient pull down in another zone. Further, in addition to the temperature, other parameters such as air velocity, mean radiant temperature, humidity need to be considered for assessing space comfort level. In our work we have developed an experimental technique for the multi-zone or comparative assessment of thermal comfort in a transient pull-down situations. First, the fan and system curves were developed for the competing designs. The predicted mean vote (PMV) methodology was employed for determining perceived comfort level. PMV is an ideal technique since it accounts for all of the above-mentioned parameters that are needed to assess space comfort level. Using an indoor climate analyzer, the transient PMV response at various locations was obtained. Conclusions are drawn to illustrate how this technique can be utilized for the simultaneous assessment of thermal comfort level in multiple zones, especially when transient pull downs are encountered.  相似文献   

12.
Ye XJ  Zhou ZP  Lian ZW  Liu HM  Li CZ  Liu YM 《Indoor air》2006,16(4):320-326
A long-term field investigation was carried out in naturally ventilated residential buildings in Shanghai from April 2003 to November 2004. A total of 1,768 returned questionnaires were collected in the study. This study deals with the thermal sensation of occupants in naturally ventilated buildings and the change in thermal neutral temperature with season. The range of accepted temperature in naturally ventilated buildings is between 14.7 degrees C T(op) and 29.8 degrees C T(op). The results also report the findings of the adaptive comfort model in Shanghai that determines the adaptive relationship of neutral temperature with outdoor air temperature. A long-term field study was carried out in residential buildings in Shanghai to find the relationship between thermal sensation, indoor neutral temperature and outdoor temperature. This paper presents findings of thermal comfort and discusses the more sustainable standard for the indoor climate of residential buildings in Shanghai.  相似文献   

13.
With rapid urbanization, big cities in the south of China are progressively falling short of sustaining outdoor thermal comfort. In this paper, a thermal comfort and energy evaluation model is derived from revisions of previous study, to simulate and predict the interaction of coupled urban building-site climate and then the thermal comfort. The methodology of principal calculations is demonstrated first, then a hypothetical district of office buildings in Shanghai is selected. Dynamic on-site climate parameters, anthropogenic heat and indoor/outdoor SET* values, etc., are simulated and evaluated. The results show the variation of outdoor SET* values influenced by factors including canopy height, building coverage and air-conditioning set-point temperature.  相似文献   

14.
The first guidelines for thermal comfort in buildings in The Netherlands were developed in the late 70s and in the 80s. They were based on the PMV-PPD relationship. In this article new guidelines are presented, based on the international research on adaptive thermal comfort. Two building/climate types are introduced: “Alpha” and “Beta”, analogous to the categories in the field studies on adaptive thermal comfort. For each building/climate type operative indoor temperature limits are given as a function of the running mean outdoor temperature and classified according to NPR-CR 1752. Finally some initial temperature simulations are shown, the results of which are plotted in the new comfort zone.  相似文献   

15.
Recently adaptive thermal-comfort criteria have been introduced in the international indoor-climate standards to reduce the heating/cooling energy requirements. In 2008, the Finnish Society of Indoor Air Quality (FiSIAQ) developed the national adaptive thermal-comfort criteria of Finland. The current study evaluates the impact of the Finnish Criteria on energy performance in an office building. Two fully mechanically air-conditioned single offices are taken as representative zones. A simulation-based optimization scheme (a combination of IDA-ICE 4.0 and a multi-objective genetic-algorithm from MATLAB-2008a) is employed to determine the minimum primary energy use and the minimum room cooling-equipment size required for different thermal comfort levels. The applicability of implementing energy-saving measures such as night ventilation, night set-back temperature, day lighting as well as optimal building envelope and optimal HVAC settings are addressed by investigating 24 design variables. The results show that, on average, an additional 10 kWh/(m2 a) primary energy demand and a larger 10 W/m2 room cooling-equipment size are required to improve the thermal comfort from medium (S2) to high-quality (S1) class; higher thermal comfort levels limit the use of night ventilation and water radiator night-set back options. Compared with the ISO EN 7730-2005 standard, the Finnish criterion could slightly decrease the heating/cooling equipment size. However, it significantly increases both the heating and cooling energy demand; the results show 32.8% increase in the primary energy demand. It is concluded that the Finnish criterion-2008 is strict and does not allow for energy-efficient solutions in standard office buildings.  相似文献   

16.
Thermally Activated Building Systems (TABS) are regarded as top-cooling systems rather than full air-conditioning systems. Therefore, adaptive thermal comfort models (ASHRAE55, ISSO74 or EN15251) are supposed to be applicable to TABS buildings, although the comfort model conditions are not necessarily satisfied. This paper investigates whether, for a moderate climate and with the heating and cooling set points chosen according to the adaptive models, the building’s energy use reduces. After all, applying adaptive models, if appropriate, is thought to lower energy use because higher maximum operative zone temperatures Top,max are allowed, compared to the conventional ISO7730 model. For purpose of generality, a building with an ideal heating and cooling system is considered. Analysis of moderate climate weather data reveals a low energy reducing potential for the ASHRAE55 and ISSO74 model, because high reference outdoor temperatures hardly occur. EN15251 on the other hand, allows very high Top,max and will lower the cooling need.A 2-zone building simulation demonstrates a higher cooling need for ASHRAE55 and ISSO74, compared to ISO7730. Because cooling is needed during the whole year, the lower winter Top,max of these adaptive models causes these unexpected results. With real data of warmer years or varying gains, this conclusion holds.  相似文献   

17.
This second part of the study uses a validated dynamic building thermal model for perimeter zones with glass facades (described in Part I) and combines it with a transient two-node thermal comfort model. The objective is to investigate the impact of varying exterior climatic conditions, glazing properties and shading properties on indoor thermal comfort and heating demand in such spaces under the presence of transmitted solar radiation. It is evident that selecting appropriate fenestration components becomes a trade-off between energy, thermal comfort, and lighting needs. Facades with insulating and low transmittance glass create more comfortable and stable conditions; however, there is a relationship between lower transmittance of the glazing and increased demand of primary heating needed, as well as with lighting energy use. Regardless of glazing type, shading can improve comfort conditions by decreasing radiant temperature asymmetry and extremes in operative temperature. The results show that perimeter building zones with high-performance facades (glazing and shading) can maintain comfortable conditions and even eliminate the need for secondary perimeter heating in cold climates.  相似文献   

18.
Mixed-mode ventilation can effectively reduce energy consumption in buildings, as well as improve thermal comfort and productivity of occupants. This study predicts thermal and energy performance of mixed-mode ventilation by integrating computational fluid dynamics (CFD) with energy simulation. In the simulation of change-over mixed-mode ventilation, it is critical to determine whether outdoor conditions are suitable for natural ventilation at each time step. This study uses CFD simulations to search for the outdoor temperature thresholds when natural ventilation alone is adequate for thermal comfort. The temperature thresholds for wind-driven natural ventilation are identified by a heat balance model, in which air change rate (ACH) is explicitly computed by CFD considering the influence of the surrounding buildings. In buoyancy-driven natural ventilation, the outdoor temperature thresholds are obtained directly from CFD-based parametric analysis. The integrated approach takes advantage of both the CFD algorithm and energy simulation while maintaining low levels of complexity, enabling building designers to utilize this method for early-stage decisionmaking. This paper first describes the workflow of the proposed integrated approach, followed by two case studies, which are presented using a three-floor office building in an urban context. The results are compared with those using an energy simulation program with built-in multizone modules for natural ventilation. Additionally, adaptive thermal comfort models are applied in these case studies, which shows the possibility of further reducing the electricity used for cooling.  相似文献   

19.
A long-term field survey was conducted with six buildings in order to investigate how the occupants adapt to the indoor climate in office buildings in Japan. More than 5000 questionnaires and corresponding indoor temperatures were collected. Clothing adjustment was observed to be related to outdoor temperature and indoor temperature, as well as dress codes. No considerable differences were found on the thermal perceptions between two groups of buildings, which provided different levels of opportunity for controlling indoor climate. With both groups, the preferred SET* was always close to 26 °C. The comfort temperature was estimated from the results of clothing adjustment and the preferred SET*. The gradient of the comfort temperature to outdoor temperature was found to be between the adaptive model for centralized HVAC and for natural ventilation. It could be caused by that the major part of the occupants in the present study had more opportunity to control their thermal conditions than in the centralized HVAC buildings (i.e. operable windows, controllable HVAC or personal fans).  相似文献   

20.
Sleep thermal environments substantially impact sleep quality. To study the sleep thermal environment and thermal comfort in China, this study carried out on-site monitoring of thermal environmental parameters in peoples’ homes, including 166 households in five climate zones, for one year. A questionnaire survey on sleep thermal comfort and adaptive behavior was also conducted. The results showed that the indoor temperature for sleep in northern China was more than 4°C higher than that in southern China in winter, while the indoor temperatures for sleep were similar in summer. Furthermore, 70% of people were satisfied with their sleep thermal environment. Due to the use of air conditioning and window opening in various areas in summer, people were satisfied with their sleep thermal environments. Due to the lack of central heating in the southern region in winter, people feel cold and their sleep thermal environment needs further improvement. The bedding insulation in summer and winter in northern China was 1.83clo and 2.67clo, respectively, and in southern China was 2.21clo and 3.17clo, respectively. Both northern China and southern China used air conditioning only in summer. People in southern China opened their windows all year, while those in northern China opened their windows during the summer and transitional periods.  相似文献   