首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The Energy Tower concept is a renewable energy source suitable for dry and hot climates. It consists in cooling air by spraying water at the top of a tower approximately 1000 m high and thus creating a downdraft with a velocity of approximately 15 m/s. At the bottom of the tower the air goes through turbines and is subsequently exhausted through diffusers to the environment. In this work the influence of heat transfer from the droplets to the air is analyzed, the effect of coalescence being described using the O’Rourque model. It is shown that coalescence is substantial inside the tower and results in the droplets being an order of magnitude larger at the tower bottom and that there is a slight adverse effect on the energy performance, since evaporation from larger droplets is substantially less than from smaller droplets. In the case however that the water spray is a saline solution – which is the only possibility in view of unsalted water being as scarce a resource as energy – it makes it possible to keep the deposited salt inside the tower and the diffuser and in the immediate vicinity of the construction.  相似文献   

2.
A numerical model for studying the evaporative cooling processes that take place in a new type of cooling tower has been developed. In contrast to conventional cooling towers, this new device called Hydrosolar Roof presents lower droplet fall and uses renewable energy instead of fans to generate the air mass flow within the tower. The numerical model developed to analyse its performance is based on computational flow dynamics for the two-phase flow of humid air and water droplets. The Eulerian approach is used for the gas flow phase and the Lagrangian approach for the water droplet flow phase, with two-way coupling between both phases. Experimental results from a full-scale prototype in real conditions have been used for validation. The main results of this study show the strong influence of the average water drop size on efficiency of the system and reveal the effect of other variables like wet bulb temperature, water mass flow to air mass flow ratio and temperature gap between water inlet temperature and wet bulb temperature. Nondimensional numerical correlation of efficiency as a function of these significant parameters has been calculated.  相似文献   

3.
Waste heat is generally dissipated from process water to atmospheric air in cooling towers. In the present study, a novel design is used to extract more amount of heat without any additional energy input by incorporating secondary ambient air in an induced draft wet cooling tower. In addition, more fresh air is induced in the tower from the rain zone, which increases the effectiveness at any value of the water to air flow rate (L/G ratio). Moreover, tower characteristics, range, and evaporation loss were also increased due to the novel design. It is noteworthy that secondary fresh air increases effectiveness, heat rejection, and tower characteristics by 10.12%, 19.65%, and 26.11%, respectively, and decreases approach by 16.32% at 0.55 L/G ratio, 44°C inlet water temperature, 29.7°C dry bulb temperature, and 18.4°C inlet air wet bulb temperature.  相似文献   

4.
《Applied Thermal Engineering》2007,27(5-6):910-917
Cooling towers are used to extract waste heat from water to atmospheric air. An energy analysis is usually used to investigate the performance characteristics of cooling tower. However, the energy concept alone is insufficient to describe some important viewpoints on energy utilization. In this study, an exergy analysis is used to indicate exergy and exergy destruction of water and air flowing through the cooling tower. Mathematical model based on heat and mass transfer principle is developed to find the properties of water and air, which will be further used in exergy analysis. The model is validated against experimental data. It is noted from the results that the amount of exergy supplied by water is larger than that absorbed by air, because the system produces entropy. To depict the utilizable exergy between water and air, exergy of each working fluid along the tower are presented. The results show that water exergy decreases continuously from top to bottom. On the other hand, air exergy is expressed in terms of convective and evaporative heat transfer. Exergy of air via convective heat transfer initially loses at inlet and slightly recovers along the flow before leaving the tower. However, exergy of air via evaporative heat transfer is generally high and able to consume exergy supplied by water. Exergy destruction is defined as the difference between water exergy change and air exergy change. It reveals that the cooling processes due to thermodynamics irreversibility perform poorly at bottom and gradually improve along the height of the tower. The results show that the lowest exergy destruction is located at the top of the tower.  相似文献   

5.
何辉 《南方能源建设》2015,2(3):101-107
基于Fluent软件,采用标准k-ε湍流模型进行应力封闭,对某工程塔内传热传质过程进行三维数值计算。计算分析了塔内外空气的速度场、温度场,建立了相关方程及气水两相间传热传质理论模型。结合工程实际情况,对冷却塔进风流场进行深入分析:1)导风板的存在降低了塔侧空气绕流流速,增大了冷却塔进风口流场的对称性,使塔内空气动力场的均匀程度增加;导风板安装高度和长度对冷却塔进风流场产生较大影响,以高11 m、长8 m导风板对# 1、# 2冷却塔性能的改善作用最大;2)导风板安装角度和块数对冷却塔进风流场产生一定影响,在导风板安装角度由0°至20°变化、在导风板安装块数由60块至90块变化时,两塔冷却性能变化影响较小。  相似文献   

6.
An analytical model was developed to describe thermodynamically the water evaporation process inside a counter‐flow wet cooling tower, where the air stream is in direct contact with the falling water, based on the implementation of the energy and mass balance between air and water stream describing thus, the rate of change of air temperature, humidity ratio, water temperature and evaporated water mass along tower height. The reliability of model predictions was ensured by comparisons made with pertinent experimental data, which were obtained from the literature. The paper elaborated the effect of atmospheric conditions, water mass flow rate and water inlet temperature on the variation of the thermodynamic properties of moist air inside the cooling tower and on its thermal performance characteristics. The analysis of the theoretical results revealed that the thermal performance of the cooling tower is sensitive to the degree of saturation of inlet air. Hence, the cooling capacity of the cooling tower increases with decreasing inlet air wet bulb temperature whereas the overall water temperature fall is curtailed with increasing water to air mass ratio. The change of inlet water temperature does not affect seriously the thermal behaviour of the cooling tower. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

7.
Based on the heat and mass transfer theory and the characteristics of general-purpose software FLUENT, a three-dimensional numerical simulation platform, composed of lots of user defined functions(UDF), has been developed to simulate the thermal performance of natural draft wet cooling towers(NDWCTs). After validation, this platform is used to analyse thermal performances of a 220m high super large cooling tower designed for inland nuclear plant under different operational conditions. Variations of outlet temperature of the cooling tower caused by changes of water flow rates, inlet water temperatures are investigated. Effects of optimization through non-uniform water distributions on outlet water temperature are discussed, and the influences on the flow field inside the cooling tower are analyzed in detail. It is found that the outlet water temperature will increase as the water flow rate increases, but the air flow rate will decrease. The outlet water temperature will decrease 0.095K and 0.205K, respectively, if two non-uniform water distribution approaches are applied.  相似文献   

8.
Abstract

A prototype cooling tower was used to explore the potential of using cooling towers compared with radiator cooling systems with 3 MW diesel engines. The working parameters were the water mass flow rate, water inlet temperature, air mass flow rate, and humidity ratio. The water mass flow rate was relatively the most effective. Three methods of calculation were used to evaluate performance—namely, heat and mass balance, psychrometric chart, and the heat and mass transfer method. The first was the best in comparison with experiments. The economic analysis of both the cooling tower and radiator systems showed that it would be more economical in the long run to use cooling towers for diesel engines.  相似文献   

9.
为了分析不同风量和喷淋水量对填料逆流闭式冷却塔热力性能的影响,建立和验证了带填料逆流闭式冷却塔热质交换的数学模型,基于焓差理论对模型计算的结果进行分析。结果表明:加入填料相当于对盘管区进口的喷淋水进行预冷,降低了喷淋水的平均温度,使带填料闭式冷却塔的冷却性能优于纯盘管闭式冷却塔;风量的增加可以提高带填料逆流闭式冷却塔和纯盘管逆流闭式冷却塔的热力性能,两种塔的冷却性能随风量增加的提升速率相同;喷淋水量的增加对纯盘管逆流闭式冷却塔的热力性能的影响较小,却可以较大幅度提高带填料逆流闭式冷却塔的热力性能。  相似文献   

10.
A three-dimensional (3D) numerical model is established and validated for cooling performance optimization between a high-level water collecting natural draft wet cooling tower (HNDWCT) and a usual natural draft wet cooling tower (UNDWCT) under the actual operation condition at Wanzhou power plant, Chongqing, China. User defined functions (UDFs) of source terms are composed and loaded into the spray, fill and rain zones. Considering the conditions of impact on three kinds of corrugated fills (Double-oblique wave, Two-way wave and S wave) and four kinds of fill height (1.25 m, 1.5 m, 1.75 m and 2 m), numerical simulation of cooling performance are analysed. The results demonstrate that the S wave has the highest cooling efficiency in three fills for both towers, indicating that fill characteristics are crucial to cooling performance. Moreover, the cooling performance of the HNDWCT is far superior to that of the UNDWCT with fill height increases of 1.75 m and above, because the air mass flow rate in the fill zone of the HNDWCT improves more than that in the UNDWCT, as a result of the rain zone resistance declining sharply for the HNDWCT. In addition, the mass and heat transfer capacity of the HNDWCT is better in the tower centre zone than in the outer zone near the tower wall under a uniform fill layout. This behaviour is inverted for the UNDWCT, perhaps because the high-level collection devices play the role of flow guiding in the inner zone. Therefore, when non-uniform fill layout optimization is applied to the HNDWCT, the inner zone increases in height from 1.75 m to 2 m, the outer zone reduces in height from 1.75 m to 1.5 m, and the outlet water temperature declines approximately 0.4 K compared to that of the uniform layout.  相似文献   

11.
Daniël Roux 《传热工程》2017,38(11-12):1044-1053
ABSTRACT

The performance of wet cooling towers can be improved by installing sprayers that distribute the cooling water uniformly onto the fill while operating at a low pressure head. This paper presents the methodology that was followed to design a new cooling tower spray nozzle. The fluid dynamics of an orifice nozzle, such as the effect of a change in pressure head, spray angle, spray height, orifice diameter, and wall thickness on drop diameter and spray distance, is experimentally investigated, and ultimately a model with which a spray nozzle can be designed is presented. The manufacture and testing of a prototype spray nozzle show that it is possible to enhance the performance of sprayers and thus wet cooling towers by means of the methods presented.  相似文献   

12.
The aim of this paper is to optimize the energy performance of cylindrical cross section evaporative wind towers as passive systems for thermal conditioning of urban spaces. Two theoretical models, a thermal model and a fluid model, have been developed to characterize the evaporative system and the tower design respectively. The thermal model evaluates the tower operation when the fan and the nozzles are working, giving as result the difference between the outlet temperature and inlet temperature. This model has been used to analyze the thermal response of the system to fluctuations in design parameters (water flow, air flow and absorption coefficient of the plastic). To that effect, three one-parametric and one multi-parametric optimization have been done. The fluid model describes the tower operation when the fan and the nozzles are not working, giving as result the wind behavior through the tower. Additional configurations of the wind tower have been evaluated: changing the number of the wind catcher openings, varying the height of the internal walls of the tower and modifying the geometry of the lower ventilation apertures.  相似文献   

13.
The use of water droplet evaporation in shower towers and passive downdraft evaporative cooling needs the estimation of the time needed to completely evaporate the drops. To solve this problem, a cellular approach is proposed in which the spray is considered as a pile of rigid spheres of equal size; each sphere has multiple layers and contains a drop in its center. The evaporation takes place gradually from the superficial layer towards the internal layers. Parametric studies show the influence of each variable on the evaporation time of the droplets. The model may be used for sizing passive evaporative cooling systems and towers for buildings using the passive evaporative down draught effect. A building equipped with a shower tower has been tested in the framework of the European project PDEC/JOULE in Catania (Italy). The spraying system was successfully sized by using the model proposed in this paper.  相似文献   

14.
为了降低火电厂烟气含湿量,以新型的上喷淋上进气喷淋塔为研究对象,采用FLUENT模型模拟喷淋塔内两相流体的运动,并与实验验证,采用单变量分析方法研究烟气流速、喷淋液滴直径、喷淋速度、喷淋流量四种因素对出口液滴逃逸率的影响。研究表明:操作条件对出口液滴逃逸率的影响程度液滴直径>进气速度>喷淋流量>喷淋速度;出口液滴逃逸率随着进气速度的增长而线性增长,喷淋流量和喷淋速度则反之;在进气速度3.5 m/s下,当液滴直径小于1.00 mm时,逃逸率随液滴直径减小而迅速上升;当直径大于1.00 mm时,液滴逃逸率几乎为0.0%,不受喷淋流量影响。  相似文献   

15.
由于具有巨大的节水优势,间接空冷机组在我国富煤少水区域得到广泛应用。研究环境风对间接空冷系统的影响机理对指导电厂运行具有重要意义。以某电厂间接空冷机组为基础,构建水平布置散热器的空冷塔群物理和数学模型,通过数值模拟方法分析环境风对塔内空气流场及空冷散热器换热性能的影响。结果表明:环境风对空冷系统塔内空气流场影响较大,进而影响空冷散热器的散热性能。随着风速的增加,空冷塔的换热性能不断恶化。在临界风速时额定负荷下,下游空冷塔换热量比上游空冷塔减少2.5%。  相似文献   

16.
A theoretical model is developed to establish an indepth understanding of the performance of a three-stage wind tower with a bypass system for indoor cooling in rural dry and hot climates. Model simulations are presented for a wide range of ambient conditions that include inlet wind speed, inlet temperature and relative humidity. Simulation results provide an insight into the desirable water flow rates and air-to-water loadings for comfort zone tem-peratures and relative humidity levels at the exit of the wind tower. Simulations show wind towers with variable cross-sections provide an increase in the cooling power for the same inlet wind speed, inlet air temperature and relative humidity when compared to wind towers with a constant cross-section. The study shall lead to a better understanding to designing wind towers that are both environmentally friendly and energy efficient.  相似文献   

17.
大流量单混合孔Y型喷嘴的雾化特性   总被引:2,自引:0,他引:2  
对大流量单混合孔Y型喷嘴的雾化性能进行了实验研究,分析了其流量特性以及气耗率对雾化粒径的影响.结果表明,单混合孔Y型喷嘴设计流量能够达到1000kg/h以上,且具有较细的雾化粒径;在气压一定时,随着水压的增大其水流量增大,气耗率减小;气耗率对雾化粒径的影响较明显,但当粒径减小到一定程度后,继续增大气耗率对雾化粒径的影响不明显;单水孔与多水孔Y型喷嘴的雾化性能无明显差别;改进的Y型喷嘴液膜随机破碎模型可较好地用于大流量单混合孔Y型喷嘴雾化粒径的预报.  相似文献   

18.
《Energy》1998,23(11):943-947
Results are presented in terms of tower characteristics, water-outlet temperature, water to air flow rate ratio (L/G ratio) and efficiency. Tower performance decreases with an increase in the L/G ratio as is also observed in other types of cooling towers.  相似文献   

19.
This paper presents a new concept of hybrid cooling, named solar enhanced natural draft dry cooling tower (SENDDCT), in which solar collectors are added to traditional natural draft dry cooling towers to increase their performance. The purpose of using solar energy in this new cooling system is to increase the suction through the tower so that more air flow is achieved through the compact heat exchangers that cool condensers of a geothermal power plant. For the same size of the cooling tower, more air flow across the heat exchangers means more heat can be rejected by the system. The governing equations for the SENDDCT are similar to those of a conventional natural draft dry cooling tower except that solar heating is added after the heat exchanger bundles. Performance comparisons show that SENDDCT has substantial advantages over conventional natural draft dry cooling towers for geothermal power plants as well as standalone solar chimney power plants.  相似文献   

20.
燃料性质的改变会导致雾化特性的变化,针对乙醇掺混航空煤油在离心式压力雾化喷嘴内的流动与雾化特性开展了研究。通过耦合流体体积法(VOF)和离散相模型(DPM),研究了不同乙醇掺混体积分数下掺混燃油在离心式喷嘴中的内部流动和外部雾化过程。研究结果表明:在压差不变时,喷嘴内空气芯直径随着掺混燃油内乙醇体积分数的增加而增大;而液膜厚度则与空气芯直径成反比,随着乙醇体积分数的增加而减小。喷嘴出口的速度随着乙醇体积分数的增加而增大;在油膜表面的波动及气动力的共同作用下,油膜失稳形成液滴,获得了不同比例下掺混燃油在喷雾外流场内的喷雾粒径分布特征,随着掺混乙醇体积分数的增加,液滴的平均直径逐渐减小。  相似文献   