首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 359 毫秒
1.
We introduce two-photon image correlation spectroscopy (ICS) using a video rate capable multiphoton microscope. We demonstrate how video rate two-photon microscopic imaging and image correlation analysis may be combined to measure molecular transport properties over ranges typical of biomolecules in membrane environments. Using two-photon ICS, we measured diffusion coefficients as large as 10−8 cm2 s−1 that matched theoretical predictions for samples of fluorescent microspheres suspended in aqueous sucrose solutions. We also show the sensitivity of the method for measuring microscopic flow using analogous test samples. We demonstrate explicitly the advantages of the image correlation approach for measurement of correlation functions with high signal-to-noise in relatively short time periods and discuss situations when these methods represent improvements over non-imaging fluorescence correlation spectroscopy. We present the first demonstration of two-photon image cross-correlation spectroscopy where we simultaneously excite (via two-photon absorption) non-identical fluorophores with a single pulsed laser. We also demonstrate cellular application of two-photon ICS for measurements of slow diffusion of green fluorescent protein/adhesion receptor constructs within the basal membrane of live CHO fibroblast cells.  相似文献   

2.
We present combined epi-coherent anti-Stokes Raman scattering (CARS) and multiphoton imaging with both chemical discrimination and subcellular resolution on human skin in vivo. The combination of both image modalities enables label-free imaging of the autofluorescence of endogenous fluorophores by two-photon excited fluorescence, as well as imaging of the distribution of intercellular lipids, topically applied substances and water by CARS. As an example for medical imaging, we investigated healthy and psoriasis-affected human skin with both image modalities in vivo and found indications for different lipid distributions on the cellular level.  相似文献   

3.
We demonstrate the potential of fluorescence lifetime imaging by time-correlated single-photon counting as a method for monitoring the transdermal diffusion pathway and diffusion rate of pharmaceuticals in human skin. The current application relies on observing subtle changes in the fluorescence lifetime of the intrinsic fluorophores present in the intracellular region between corneocytes of the stratum corneum. We have comprehensively characterized the measured fluorescence lifetimes from intracorneocyte junctions in three skin section types (dermatomed skin, epidermal membranes and stratum corneum) revealing statistically significant differences of the short lifetime component between each of the types, which we attribute to the sample preparation and imaging method. We show using epidermal membrane sections that application of a drug/solvent formulation consisting of ethinyl estradiol and spectroscopic grade ethanol to the surface gives rise to a slight but statistically significant shortening of the fluorescence lifetime of the long-lived emitting species present in the sample, from approximately 2.8 ns to 2.5 ns. The method may be useful for future studies where the kinetics and pathways of a variety of applied formulations could be investigated.  相似文献   

4.
In the femtoliter observation volume of a two-photon microscope, multiple fluorophores can be present and complex photophysics can take place. Combined detection of the fluorescence emission spectra and lifetimes can provide deeper insight into specimen properties than these two imaging modalities taken separately. Therefore, we have developed a detection scheme based on a frequency-modulated multichannel photomultiplier, which measures simultaneously the spectrum and the lifetime of the emitted fluorescence. Experimentally, the efficiency of the frequency domain lifetime measurement was compared to a time domain set-up. The performance of this spectrally and lifetime-resolved microscope was evaluated on reference specimens and living cells labeled with three different stains targeting the membrane, the mitochondria, and the nucleus.  相似文献   

5.
Studies of proteins' interaction in cells by FRET can take benefit from two important photo-physical properties describing fluorescent proteins: fluorescence emission spectrum and fluorescence lifetime. These properties provide specific and complementary information about the tagged proteins and their environment. However, none of them taken individually can completely quantify the involved fluorophore characteristics due to their multiparametric dependency with molecular environment, experimental conditions, and interpretation complexity. A solution to get a better understanding of the biological process implied at the cellular level is to combine the spectral and temporal fluorescence data acquired simultaneously at every cell region under investigation. We present the SLiM-SPRC160, an original temporal/spectral acquisition system for simultaneous lifetime measurements in 16 spectral channels directly attached to the descanned port of a confocal microscope with two-photon excitation. It features improved light throughput, enabling low-level excitation and minimum invasivity in living cells studies. To guarantee a fairly good level of accuracy and reproducibility in the measurements of fluorescence lifetime and spectra on living cells, we propose a rigorous protocol for running experiments with this new equipment that preserves cell viability. The usefulness of SLiM approach for the precise determination of overlapping fluorophores is illustrated with the study of known solutions of rhodamine. Then, we describe reliable FRET experiments in imaging mode realized in living cells using this protocol. We also demonstrate the benefit of localized fluorescence spectrum-lifetime acquisitions for the dynamic study of fluorescent proteins. proteins.  相似文献   

6.
Fluorescence correlation spectroscopy (FCS) is a very sensitive technique that can be used, e.g., for the measurement of low concentrations and for the investigation of transport of fluorescent molecules. Fluorescence lifetime imaging (FLIM) provides spatially resolved information about molecular fluorescence lifetimes reflecting the interactions of the molecules with their environment. We have applied simultaneous two-photon FCS and FLIM to probe the behavior of fluorescent molecules diffusing in submicrometer silicon oxide channels. Our measurements reveal differences in fluorescence lifetimes compared to bulk solution that result from the effects of confinement and the presence of interfaces. Confinement also affects diffusional characteristics of fluorophores as reflected in fluorescence autocorrelation functions. These possible consequences of both spatial confinement and the presence of interfaces between media with different refractive indices on the diffusion and fluorescence lifetime of molecules in nanostructures are discussed in general.  相似文献   

7.
Fluorescence lifetime imaging (FLIM) provides a complementary contrast mechanism to fluorescence intensity and ratio imaging in intact tissue. With FLIM the time-resolved decay in fluorescence intensity of (interacting) fluorophores can be quantified by means of time correlated single photon counting (TCSPC). Here we focus on fluorescence lifetime imaging in intact blood vessels. Requisites for imaging in intact tissue are good penetration depth and limited tissue damage. Therefore, in this pilot-study, we performed TCSPC-FLIM using two-photon laser scanning microscopy to determine, with sub-cellular resolution, the fluorescence lifetime of two fluorescent probes. First, we focused on the nucleic acid dye SYTO41 in the various compartments of cells in vitro and in situ in the wall of intact mouse carotid arteries. Second, it was assessed whether the interaction of the lectin WGA-FITC with the endothelial glycocalyx affects its fluorescence lifetime. Results showed comparable mono-exponential fluorescence lifetimes of SYTO41 in the nuclei of cells in vitro and in situ. The slightly shorter fluorescence lifetime observed in the cytoplasm allowed discrimination of the nuclei. SYTO41 displayed strong mitochondrial staining, as was verified by the mitochondrion-specific probe CMXRos. In addition, mitochondrial staining by SYTO41 was accompanied by a green shift in emission. In the mitochondrial region, SYTO41 showed a highly bi-exponential and relatively fast decay, with two distinct lifetime components. It is hypothesized that the fitted bi-exponential decay can either be contributed to (1) the mathematical approximation of the fluorescence intensity decay or (2) the presence of free and DNA-bound SYTO41 in the mitochondrial compartment, leading to two lifetime components. The fluorescence lifetime of WGA-FITC decreased by approximately 25% upon binding to the endothelial glycocalyx. From this study, we conclude that FLIM offers an additional contrast mechanism in imaging intact tissue and provides information on binding status between a probe and its ligand.  相似文献   

8.
Two-photon activation of photoactivatable green fluorescent protein (PA-GFP) provides a unique tool for probing cellular transport processes, because activation is strictly limited to the sub-femtoliter optical volume of the two-photon spot. We demonstrate two-photon activation of PA-GFP immobilized in a gel and freely diffusing within cells and recover a quadratic power dependence. Illumination at 820 nm allows simultaneous activation and fluorescence monitoring by two-photon excitation. Alternatively, we activate PA-GFP using two-photon excitation and monitor the fluorescence of the photoconverted product with one-photon excitation. We probe nucleocytoplasmic transport through the nuclear pore complex of COS-1 cells, by observing the time-dependent fluorescence at various locations within the cell after two-photon activation of PA-GFP in the nucleus and in the cytoplasm. Two-photon activation of a tandem construct of two PA-GFPs showed a markedly slower rate of crossing through the nuclear pore. Analysis based on a restricted diffusion model yields a nuclear pore radius of 4.5 nm, which is in good agreement with previously reported values. This application demonstrates the attractive features of two-photon photoactivation over traditional techniques, such as photobleaching, for studying transport processes in cells.  相似文献   

9.
Two‐photon absorption and emission spectra for fluorophores relevant in cell imaging were measured using a 45 fs Ti:sapphire laser, a continuously tuneable optical parametric amplifier for the excitation range 580–1150 nm and an optical multichannel analyser. The measurements included DNA stains, fluorescent dyes coupled to antibodies as well as organelle trackers, e.g. Alexa and Bodipy dyes, Cy2, Cy3, DAPI, Hoechst 33342, propidium iodide, FITC and rhodamine. In accordance with the two‐photon excitation theory, the majority of the investigated fluorochromes did not reveal significant discrepancies between the two‐photon and the one‐photon emission spectra. However, a blue‐shift of the absorption maxima ranging from a few nanometres up to considerably differing courses of the spectrum was found for most fluorochromes. The potential of non‐linear laser scanning fluorescence microscopy is demonstrated here by visualizing multiple intracellular structures in living cells. Combined with 3D reconstruction techniques, this approach gives a deeper insight into the spatial relationships of subcellular organelles.  相似文献   

10.
Three-dimensional confocal imaging of polymer samples was achieved by the use of two-photon excited fluorescence in both positive and negative contrast modes. The fluorophore was a new and highly efficient two-photon induced upconverter, resulting in improved signal strength at low pumping power. Because of the relatively long wavelength of the excitation source (798 nm from a mode-locked Ti:Sap-phire laser), this technique shows a larger penetration depth into the samples than provided by conventional single-photon fluorescence confocal microscopy. Single-photon and two-photon images of the same area of each sample show significant differences. The results suggest the possibility of using two-photon confocal microscopy, in conjunction with highly efficient fluorophores, as a tool to study the surface, interface, and fracture in material science applications.  相似文献   

11.
We discuss the use of fluorescence correlation spectroscopy for the measurement of relatively slow rotations of large macromolecules in solution or attached to other macromolecular structures. We present simulations and experimental results to illustrate the range of rotational correlation times and diffusion times that the technique can analyze. In particular, we examine various methods to analyze the polarization fluctuation data. We have found that by first constructing the polarization function and then calculating the autocorrelation function, we can obtain the rotational motion of the molecule with very little interference from the lateral diffusion of the macromolecule, as long as the rotational diffusion is significantly faster than the lateral diffusion. Surprisingly, for common fluorophores the autocorrelation of the polarization function is relatively unaffected by the photon statistics. In our instrument, two-photon excitation is used to define a small volume of illumination where a few molecules are present at any instant of time. The measurements of long DNA molecules labeled with the fluorescent probe DAPI show local rotational motions of the polymers in addition to translation motions of the entire polymer. For smaller molecules such as EGFP, the viscosity of the solution must be increased to bring the relaxation due to rotational motion into the measurable range. Overall, our results show that polarized fluorescence correlation spectroscopy can be used to detect fast and slow rotational motion in the time scale from microsecond to second, a range that cannot be easily reached by conventional fluorescence anisotropy decay methods.  相似文献   

12.
We show the viability of high-resolution two-photon fluorescence imaging of fixed and live cells by exciting the fluorophores with a train of near-infrared pulses with duration in the picosecond range. This is exemplified with a compact, diode-pumped Nd:YVO4 laser, emitting trains of 7-ps pulses at a wavelength of 1064 nm, with a repetition rate of 200 MHz at two separate outputs. Incoherent combination of the outputs enabled two-photon excitation with a repetition rate of 400 MHz. For a numerical aperture of 1.4 (oil), we used an average illumination power of up to 20–40 mW at the sample. The pulses were coupled into a beam scanning microscope, either directly or through a single mode glass fibre. Compared with standard femtosecond titanium–sapphire excitation conditions, our experiments were performed with a 2.5 or 5 times higher repetition rate, 30–70 times longer pulses and 10–35 times lower pulse peak intensity. The experiments indicate the possibility of significantly relaxing the temporal pulse width constraints for a series of applications.  相似文献   

13.
Multiphoton microscopy in life sciences   总被引:13,自引:1,他引:12  
Near infrared (NIR) multiphoton microscopy is becoming a novel optical tool of choice for fluorescence imaging with high spatial and temporal resolution, diagnostics, photochemistry and nanoprocessing within living cells and tissues. Three‐dimensional fluorescence imaging based on non‐resonant two‐photon or three‐photon fluorophor excitation requires light intensities in the range of MW cm?2 to GW cm?2, which can be derived by diffraction limited focusing of continuous wave and pulsed NIR laser radiation. NIR lasers can be employed as the excitation source for multifluorophor multiphoton excitation and hence multicolour imaging. In combination with fluorescence in situ hybridization (FISH), this novel approach can be used for multi‐gene detection (multiphoton multicolour FISH). Owing to the high NIR penetration depth, non‐invasive optical biopsies can be obtained from patients and ex vivo tissue by morphological and functional fluorescence imaging of endogenous fluorophores such as NAD(P)H, flavin, lipofuscin, porphyrins, collagen and elastin. Recent botanical applications of multiphoton microscopy include depth‐resolved imaging of pigments (chlorophyll) and green fluorescent proteins as well as non‐invasive fluorophore loading into single living plant cells. Non‐destructive fluorescence imaging with multiphoton microscopes is limited to an optical window. Above certain intensities, multiphoton laser microscopy leads to impaired cellular reproduction, formation of giant cells, oxidative stress and apoptosis‐like cell death. Major intracellular targets of photodamage in animal cells are mitochondria as well as the Golgi apparatus. The damage is most likely based on a two‐photon excitation process rather than a one‐photon or three‐photon event. Picosecond and femtosecond laser microscopes therefore provide approximately the same safe relative optical window for two‐photon vital cell studies. In labelled cells, additional phototoxic effects may occur via photodynamic action. This has been demonstrated for aminolevulinic acid‐induced protoporphyrin IX and other porphyrin sensitizers in cells. When the light intensity in NIR microscopes is increased to TW cm?2 levels, highly localized optical breakdown and plasma formation do occur. These femtosecond NIR laser microscopes can also be used as novel ultraprecise nanosurgical tools with cut sizes between 100 nm and 300 nm. Using the versatile nanoscalpel, intracellular dissection of chromosomes within living cells can be performed without perturbing the outer cell membrane. Moreover, cells remain alive. Non‐invasive NIR laser surgery within a living cell or within an organelle is therefore possible.  相似文献   

14.
Three-dimensional (3-D) imaging of fluorescence resonance energy transfer (FRET) in human cells under two-photon excitation was demonstrated in this study. A sample was prepared by expressing a donor and an acceptor in living cells and using an antibody to secure the proximity of contact between the donor and the acceptor. The quenching of fluorescence emission of a donor in the double-labelled cells indicates the presence of FRET that occurred in these living cells. Because of the quadratic relation of the excitation power, 3-D localisation of FRET becomes possible.  相似文献   

15.
Confocal laser scanning microscopy of calcium dynamics in living cells.   总被引:4,自引:0,他引:4  
Confocal laser scanning microscopy (CLSM) is widely used to monitor intracellular calcium levels in living cells loaded with calcium-sensitive fluorophores. This review examines the basic advantages and limitations of CLSM in in vivo imaging analyses of calcium dynamics. The benefits of utilizing ratioed images and dextran-conjugated fluorophores are addressed, and practical aspects of handling confocal datasets are outlined. After considering some relatively new microscopical methods that can be used in conjunction with conventional CLSM, possible future applications of confocal techniques in analyses of intracellular calcium dynamics are discussed.  相似文献   

16.
Two-photon fluorescence lifetime imaging microscopy was used noninvasively to monitor a fluorescent antigen during macrophage-mediated endocytosis, intracellular vacuolar encapsulation, and protease-dependent processing. Fluorescein-conjugated bovine serum albumin (FITC–BSA) served as the soluble exogenous antigen. As a relatively nonfluorescent probe in the native state, the antigen was designed to reflect sequential intracellular antigen processing events through time-dependent changes in fluorescence properties. Using two-photon lifetime imaging microscopy, antigen processing events were monitored continuously for several hours. During this time, the initial fluorescein fluorescence lifetime of 0.5 ns increased to α 3.0 ns. Control experiments using fluorescein conjugated poly- l -lysine and poly- d -lysine demonstrated that the increase in fluorescence parameters observed with FITC–BSA were due to intracellular proteolysis since addition of the inert d -isomer did not promote an increase in fluorescence lifetime or intensity. Comparisons of intravacuolar and extracellular FITC–dextran concentration suggested active localization of dextran in the vacuoles by the macrophage. In addition, the kinetics of degradation observed using two-photon microscopy were similar to results obtained on the flow cytometer, thus validating the use of flow cytometry for future studies.  相似文献   

17.
The amphiphilic dye FM4–64 is used to investigate endocytosis and vesicle trafficking in living eukaryotic cells. The standing hypothesis is that it is inserted into the outer leaflet of the plasma membrane and, from there, is passed on to intracellular membrane compartments by endocytosis. We tested this hypothesis by microinjecting FM4–64 into the cytoplasm and vacuole of Nicotiana tabacum BY-2 suspension culture cells and Tradescantia virginiana stamen hair cells. We found that the dye did not label any membranes when injected into the cytoplasm, but clearly labelled the tonoplast when injected directly into the vacuole. However, because the dye is pH-sensitive, the fluorescence intensity between the plasma membrane and tonoplast varied. We conclude that FM4–64 is a specific marker for the endocytic pathway. Nevertheless, little is known about the molecular interactions of FM4–64 with these particular phospholipid membrane leaflets. We, therefore, appeal for biochemical research to determine which membrane lipids FM4–64 interacts with.  相似文献   

18.
Scanning near-field optical microscopy (SNOM) has been employed to simultaneously acquire high-resolution fluorescence images along with shear-force atomic force microscopy from cell membranes. Implementing such a technique overcomes the limits of optical diffraction found in standard fluorescence microscopy and also yields vital topographic information. The application of the technique to investigate cell-cell adhesion has revealed the interactions of filopodia and their functional relationship in establishing adherens junctions. This has been achieved via the selective tagging of the cell adhesion protein, E-cadherin, by immunofluorescence labelling. Two labelling routes were explored; Alexa Fluor 488 and semiconductor quantum dots. The quantum dots demonstrated significantly enhanced photostability and high quantum yield making them a versatile alternative to the conventional organic fluorophores often used in such a study. Analysis of individual cells revealed that E-cadherin is predominantly located along the cell periphery but is also found to extend throughout their filopodia. We have demonstrated that with a fully optimised sample preparation methodology, quantum dot labelling in conjunction with SNOM imaging can be successfully applied to interrogate biomolecular localisation within delicate cellular membranes.  相似文献   

19.
Huang Z  Chen R  Li Y  Zhuang H  Chen J  Wang L 《Scanning》2008,30(6):443-447
Autofluorescence spectra and optical imaging of Platymonas subcordiformis after irradiation of diode laser were observed via laser scanning confocal microscopy (LSCM). With 488 nm Ar(+) laser excitation, the horizontal and vertical dimensions of a cup-shaped chloroplast of the irradiation group increased about 10% compared with the control group. The fluorescence spectra were similar between irradiation group and control group with a maximum fluorescence band around 682 nm, whereas the former has a higher intensity. Image of a small circular substance with stronger two-photon autofluorescence (TPA) was obtained when using two-photon excitation wavelength of 800 nm in single-channel mode. Further analysis by the 800 nm excitation based on two independent-channels mode showed an emission band of the small circular substance around 376-505 nm, which corresponded to the eyespot of P. subcordiformis. In lambda scanning mode, with two-photon wavelength of 800 nm excitation, six fluorescence peaks that are located at 465, 520, 560, 617, 660 and 680 nm were observed; the fluorescence intensity of the irradiation group was higher than that of the control group, especially at 520, 560 and 617 nm. As a conclusion, diode laser irradiation can promote chloroplast growth of P. subcordiformis cells in the form of expanding area and the increasing content of protein, phospholipids and chlorophyll. LSCM, especially TPA imaging based on femtosecond laser excitation, provides a nondestructive, real-time and accurate method to study changes of living algal cells under laser irradiation and other environmental factors.  相似文献   

20.
We report the development of a system combining the capabilities of fluorescence imaging spectroscopy ( x , λ, I ), fluorescence lifetime (τ) and static and dynamic fluorescence anisotropy ( r ), enabling the wide-field measurement of the spectroscopic parameters of fluorophores: ( x , λ, I , τ, r ). The system employs a frequency domain data collection strategy with a modulated light emitting diode as the light source. A polarization rotator placed in the excitation path after a polarizer allows alternating parallel and perpendicular images to be collected without moving parts. A second polarizer on the emission side serves as the analyzer, leading to estimations of the wavelength-dependent dynamic anisotropies. The spectrograph has a nominal range of 365–920 nm; however, the light-emitting diodes and filter sets used in this study restricted the usable range from about 510 to 700 nm. The system was tested on rhodamine 6G (R6G) solutions containing 0, 15, 37, 45, 59, 74 and 91 glycerol. These experiments gave rotational diffusion results comparing favourably with literature values while also demonstrating a trend towards shorter measured lifetimes at high refractive index. The ability of the system to resolve mixtures was tested on mixtures of anti-human IgG-FITC (γ-chain-specific) and R6G. These fluorophores have similar lifetimes but could be separated using anisotropy parameters. The imaging capabilities of the system were tested on mixtures of fluorescent beads with glycerol solutions of R6G.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号