首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Bubble growth behavior and heat transfer characteristics during subcooled flow boiling in segmented finned microchannels have been numerically investigated. Simulations have been performed for a single row of segmented finned microchannel and predicted results are compared with experimental investigations. Onset of nucleation, formation of bubbles, their growth and movements have been investigated for different values of applied heat flux. Mechanism of bubble expansion without clogging resulting in enhanced heat transfer in segmented finned microchannels has been explained. Temperature and pressure fluctuations during subcooled flow boiling condition have been investigated. It is observed that at high heat flux, thin liquid film trapped between the bubble and channel wall is evaporated leading to localized heating effect. Predicted flow patterns are similar to experimental results. However, simulations over predict the bubble growth rate and heat transfer coefficient.  相似文献   

2.
Yuying Yan  Yingqing Zu 《传热工程》2013,34(13-14):1182-1190
This paper reports the results of numerical study on bubbles deformation, flow, and coalescence under pseudo-nucleate boiling conditions in horizontal mini-/microchannels. The numerical simulation, which is based on the multiphase model of volume of fluid method, aims to study the corresponding flow behaviors of nucleate bubbles generated from the tube walls in mini-/microchannels so as to understand the effect of confined surfaces/walls on nucleate bubbles and heat transfer. Under the pseudo- or quasi-nucleate boiling condition, superheated small vapor bubbles are injected at the wall to ensure that the bubbles generation is under a similar condition of real nucleation. The numerical study examined the fluid mechanics of bubble motion with heat transfer, but the mass transfer across the bubble–liquid interface is not simulated in the present work.  相似文献   

3.
Subcooled flow boiling heat transfer characteristics of refrigerant R-134a in a vertical plate heat exchanger (PHE) are investigated experimentally in this study. Besides, the associated bubble characteristics are also inspected by visualizing the boiling flow in the vertical PHE. In the experiment two vertical counterflow channels are formed in the exchanger by three plates of commercial geometry with a corrugated sinusoidal shape of a chevron angle of 60°. Upflow boiling of subcooled refrigerant R-134a in one channel receives heat from the downflow of hot water in the other channel. The effects of the boiling heat flux, refrigerant mass flux, system pressure and inlet subcooling of R-134a on the subcooled boiling heat transfer are explored in detail. The results are presented in terms of the boiling curves and heat transfer coefficients. The measured data showed that the slopes of the boiling curves change significantly during the onset of nucleate boiling (ONB) especially at low mass flux and high saturation temperature. Besides, the boiling hysteresis is significant at a low refrigerant mass flux. The subcooled boiling heat transfer coefficient is affected noticeably by the mass flux of the refrigerant. However, increases in the inlet subcooling and saturation temperature only show slight improvement on the boiling heat transfer coefficient.The photos from the flow visualization reveal that at higher imposed heat flux the plate surface is covered with more bubbles and the bubble generation frequency is substantially higher, and the bubbles tend to coalesce to form big bubbles. But these big bubbles are prone to breaking up into small bubbles as they move over the corrugated plate, producing strong agitating flow motion and hence enhancing the boiling heat transfer. We also note that the bubbles nucleated from the plate are suppressed to a larger degree for higher inlet subcooling and mass flux. Finally, empirical correlations are proposed to correlate the present data for the heat transfer coefficient and the bubble departure diameter in terms of boiling, Froude, Reynolds and Jakob numbers.  相似文献   

4.
Recent literature indicates that under certain conditions the heat transfer coefficient during flow boiling in microchannels is quite similar to that under pool boiling conditions. This is rather unexpected, as microchannels are believed to provide significant heat transfer enhancement under single-phase as well as flow boiling conditions. This article explores the underlying heat transfer mechanisms and illustrates the similarities and differences between the two processes. Formation of elongated bubbles and their passage over the microchannel walls have similarities to the bubble ebullition cycle in pool boiling. During the passage of elongated bubbles, the longer duration between two successive liquid slugs leads to wall dryout and a critical heat flux that may be lower than that under pool boiling conditions. A clear understanding of these phenomena will help in overcoming these limiting factors and in developing strategies for enhancing heat transfer during flow boiling in microchannels.  相似文献   

5.
A simultaneous visualization and measurement study has been carried out to investigate effects of inlet/outlet configurations on flow boiling instabilities in parallel microchannels, having a length of 30 mm and a hydraulic diameter of 186 μm. Three types of inlet/outlet configurations were investigated. Fluid flow entering to and exiting from the microchannels with the Type-A connection was restricted because the inlet and outlet conduits were perpendicular to the microchannels. The fluid flow had no restriction in entering to and existing from the microchannels with the Type-B connection. In the Type-C connection, fluid flow was restricted in entering each microchannel but was not restricted in exiting from the microchannels. It is found that amplitudes of temperature and pressure oscillations in the Type-B connection are much smaller than those in the Type-A connection under the same heat flux and mass flux conditions. On the other hand, nearly steady flow boiling exists in the parallel microchannels with the Type-C connection under the experimental conditions. Therefore, this configuration is recommended for high-heat-flux microchannel applications. As predicted, the stability threshold is determined by the minimum in the pressure-drop-versus-flow-rate curve. The pressure drop and heat transfer coefficient versus vapor quality for flow boiling in microchannels with the Type-C connection are presented. It is found that experimental data of pressure drop are higher and heat transfer coefficients are lower for boiling flow at high vapor quality in microchannels than those predicted from correlation equations for boiling flow in macrochannels, due to local dryout.  相似文献   

6.
An experiment is conducted here to investigate the effects of the imposed time periodic refrigerant flow rate oscillation in the form of nearly a triangular wave on refrigeriant R-134a flow boiling heat transfer and associated bubble characteristics in a horizontal narrow annular duct with the duct gap fixed at 2.0 mm. The results indicate that when the imposed heat flux is close to that for the onset of stable flow boiling, intermittent flow boiling appears in which nucleate boiling on the heated surface does not exist in an entire periodic cycle. At somewhat higher heat flux persistent boiling prevails. Besides, the refrigerant flow rate oscillation only slightly affects the time-average boiling curves and heat transfer coefficients. Moreover, the heated wall temperature, bubble departure diameter and frequency, and active nucleation site density are found to oscillate periodically in time as well and at the same frequency as the imposed mass flux oscillation. Furthermore, in the persistent boiling the resulting heated wall temperature oscillation is stronger for a longer period and a larger amplitude of the mass flux oscillation. And for a larger amplitude of the mass flux oscillation, stronger temporal oscillations in the bubble characteristics are noted. The effects of the mass flux oscillation on the size of the departing bubble and active nucleation site density dominate over the bubble departure frequency, causing the heated wall temperature to decrease and heat transfer coefficient to increase at reducing mass flux in the flow boiling, opposing to that in the single-phase flow. But they are only mildly affected by the period of the mass flux oscillation. However, a short time lag in the wall temperature oscillation is also noted. Finally, a flow regime map is provided to delineate the boundaries separating different boiling regimes for the R-134a flow boiling in the annular duct.  相似文献   

7.
Experiments on transition and flow boiling heat transfer with refrigerant R114 inside a horizontal tube were performed at bubble flow, critical heat flux and in the transition region between bubble flow and film boiling at mass fluxes between 1200 and 4000 kg/m2 s and in the pressure range between 5 and 15 bar. In comparison with pool boiling bubble flow heat transfer depends essentially on the mass flow rates and on the vapor quality. The critical heat flux depends less on the temperature difference than in pool boiling heat transfer and exhibits a maximal and a minimal value as a function of the pressure. The critical heat flux increases with mass flow rate as already shown by Collier. In the region of transition boiling the heat flux over the difference between wall and saturation temperature approaches a horizontal curve. Therefore in this region an evaporator may always be operated under stable conditions and burn out does not occur.  相似文献   

8.
A simultaneous visualization and measurement study have been carried out to investigate flow boiling instabilities of water in microchannels at various heat fluxes and mass fluxes. Two separate flow boiling experiments were conducted in eight parallel silicon microchannels (with flow interaction from neighboring channels at headers) and in a single microchannel (without flow interaction), respectively. These microchannels, at a length of 30 mm, had an identical trapezoidal cross-section with a hydraulic diameter of 186 μm. At a given heat flux and inlet water temperature, it was found that stable and unstable flow boiling regimes existed, depending on the mass flux. A flow boiling map, in terms of heat flux vs mass flux, showing stable flow boiling regime and unstable flow boiling regime is presented for parallel microchannels as well as for a single microchannel, respectively, at an inlet water temperature of 35 °C. In the stable flow boiling regime, isolated bubbles were generated and were pushed away by the incoming subcooled liquid. Two unstable flow boiling regimes, with long-period oscillation (more than 1 s) and short-period oscillation (less than 0.1 s) in temperature and pressure, were identified. The former was due to the expansion of vapor bubble from downstream while the latter was owing to the flow pattern transition from annular to mist flow. A comparison of results of flow boiling in parallel microchannels and in a single microchannel shows that flow interaction effects from neighboring channels at the headers are significant.  相似文献   

9.
The interfacial heat transfer coefficient is an important parameter for the analysis of multi-phase flow. In subcooled boiling flow, bubbles condense through the interface of phases and the interfacial heat transfer determines the condensation rate which affects the two-phase parameters such as void fraction and local liquid temperature. Thus, the present experiments are conducted to correlate the interfacial heat transfer coefficient at low pressure in the subcooled boiling flow. The local liquid temperature is measured by microthermocouple and the bubble condensation rate is estimated by orthogonal, two-image processing. The condensate Nusselt number, which is a function of bubble Reynolds number, local liquid Prandtl number, and local Jacob number, is obtained from the experimental results. The bubble history is derived from the newly proposed correlation and the condensate Nusselt number is compared with the previous models.  相似文献   

10.
An experiment is conducted here to investigate the saturated flow boiling heat transfer characteristics of ozone friendly refrigerant R-410A in a horizontal annular finned duct. Meanwhile the associated bubble characteristics in the duct are also inspected from the flow visualization. The experimental data are presented in terms of saturated flow boiling curves, boiling heat transfer coefficients and flow photos. In addition, empirical correlation equations for the saturated flow boiling heat transfer coefficient and mean bubble departure diameter are proposed. The saturated flow boiling curves show that boiling hysteresis is insignificant in the flow and the wall superheat needed for the onset of nucleate boiling is slightly affected by the refrigerant mass flux. Besides, the boiling curves are mainly affected by the imposed heat flux and refrigerant mass flux. Moreover, the measured saturated flow boiling heat transfer coefficient increases with the imposed heat flux and refrigerant mass flux. Furthermore, at a higher refrigerant mass flux the departing bubbles are smaller.  相似文献   

11.
Experiments are conducted here to investigate how the channel size affects the saturated flow boiling heat transfer and associated bubble characteristics of refrigerant R-134a in a horizontal narrow annular duct. The gap of the duct is fixed at 1.0 and 2.0 mm in this study. The measured heat transfer data indicate that the saturated flow boiling heat transfer coefficient increases with a decrease in the gap of the duct. Besides, raising the imposed heat flux can cause a significant increase in the boiling heat transfer coefficients. However, the effects of the refrigerant mass flux and saturated temperature on the boiling heat transfer coefficient are milder. The results from the flow visualization show that the mean diameter of the bubbles departing from the heating surface decreases slightly at increasing R-134a mass flux. Moreover, the bubble departure frequency increases at reducing duct size mainly due to the rising shear stress of the liquid flow, and at a high imposed heat flux many bubbles generated from the cavities in the heating surface tend to merge together to form big bubbles. Correlation for the present saturated flow boiling heat transfer data of R-134a in the narrow annular duct is proposed. Additionally, data for some quantitative bubble characteristics such as the mean bubble departure diameter and frequency and the active nucleation site density are also correlated.  相似文献   

12.
An experiment is conducted here to investigate how the channel size affects the subcooled flow boiling heat transfer and the associated bubble characteristics of refrigerant R-407C in a horizontal narrow annular duct with the gap of the duct fixed at 1.0 and 2.0 mm. The measured boiling curves indicate that the temperature overshoot at ONB is relatively significant for the subcooled flow boiling of R-407C in the duct. Besides, the subcooled flow boiling heat transfer coefficient increases with a reduction in the duct gap, but decreases with an increase in the inlet liquid subcooling. Moreover, raising the heat flux imposed on the duct can cause a significant increase in the boiling heat transfer coefficients. However, the effects of the refrigerant mass flux and saturated temperature on the boiling heat transfer coefficient are slighter. Visualization of the subcooled flow boiling processes in the duct reveals that the bubbles are suppressed to become smaller and less dense by raising the refrigerant mass flux and inlet subcooling. Raising the imposed heat flux, however, produces positive effects on the bubble population, coalescence and departure frequency. Meanwhile, the present heat transfer data for R-407C are compared with the R-134a data measured in the same duct and with some existing correlations. We also propose empirical correlations for the present data for the R-407C subcooled flow boiling heat transfer and some quantitative bubble characteristics such as the mean bubble departure diameter and frequency and the active nucleation site density.  相似文献   

13.
Experiments are conducted here to investigate how the channel size affects the subcooled flow boiling heat transfer and associated bubble characteristics of refrigerant R-134a in a horizontal narrow annular duct. The gap of the duct is fixed at 1.0 and 2.0 mm in this study. From the measured boiling curves, the temperature undershoot at ONB is found to be relatively significant for the subcooled flow boiling of R-134a in the duct. The R-134a subcooled flow boiling heat transfer coefficient increases with a reduction in the gap size, but decreases with an increase in the inlet liquid subcooling. Besides, raising the imposed heat flux can cause a substantial increase in the subcooled boiling heat transfer coefficient. However, the effects of the refrigerant mass flux and saturated temperature on the boiling heat transfer coefficient are small in the narrow duct. Visualization of the subcooled flow boiling processes reveals that the bubbles are suppressed to become smaller and less dense by raising the refrigerant mass flux and inlet subcooling. Moreover, raising the imposed heat flux significantly increases the bubble population, coalescence and departure frequency. The increase in the bubble departure frequency by reducing the duct size is due to the rising wall shear stress of the liquid flow, and at a high imposed heat flux many bubbles generated from the cavities on the heating surface tend to merge together to form big bubbles. Correlation for the present subcooled flow boiling heat transfer data of R-134a in the narrow annular duct is proposed. Additionally, the present data for some quantitative bubble characteristics such as the mean bubble departure diameter and frequency and the active nucleation site density are also correlated.  相似文献   

14.
本文对CO_2在水平微细管内流动沸腾特性进行实验研究。实验结果表明:热流密度增加对强化核态沸腾换热和高干度区域流型转变具有显著影响,随着热流密度的增加换热系数增加,对摩擦压降影响很小;质量流率对于换热系数的影响较小,但随着质量流率的增加摩擦压降大幅增加,质量流率的大小直接决定了换热过程所经历流态;饱和温度升高换热系数相应升高,摩擦压降减小,且对流态转变特性有重要影响。在同样工况下摩擦压降最大值先于换热系数最大值出现,理论分析采用的流态形式与实际CO_2管内流动流动沸腾换热流态基本一致。  相似文献   

15.
Nucleate boiling heat transfer and bubble dynamics in a thin liquid film on a horizontal rotating disk were studied. A series of experiments were conducted to determine the heat transfer coefficient on the disk. At low rotation and flow rates, vigorous boiling increased the heat transfer coefficients above those without boiling. Higher rotational speeds and higher flow rates increased the heat transfer coefficient and suppressed boiling by decreasing the superheat in the liquid film. The flow field on the disk, which included supercritical (thin film) flow upstream of a hydraulic jump, and subcritical (thick film) flow downstream of a hydraulic jump, affected the type of bubble growth. Three types of bubble growth were identified. Vigorous boiling with large, stationary bubbles were observed in the subcritical flow. Supercritical flow produced small bubbles that remained attached to the disk and acted as local obstacles to the flow. At low rotational rates, the hydraulic jump that separated the supercritical and subcritical regions produced hemispherical bubbles that protruded out of the water film surface and detached from the disk, allowing them to slide radially outward. A model of the velocity and temperature of the microlayer of water underneath these sliding bubbles indicated that the microlayer thickness was approximately 1/25th of that of the surrounding water film. This microlayer is believed to greatly enhance the heat transfer rate underneath the sliding bubbles.  相似文献   

16.
At this time, a widely accepted model that can predict flow boiling heat transfer in microchannels with different fluids, geometries, and operative conditions is still missing. Depending on the working fluid, a predicting correlation can lead to accurate estimation or give rise to errors up to 50% and higher. The situation is further complicated when the working fluid is a zeotropic mixture of two components, due to the additional mass transfer resistance that must be estimated. In the recent years much attention has been paid to the possible use of fluorinated propene isomers in substitution for high-global-warming-potential refrigerants. The available hydrofluoroolefins cannot cover all the air-conditioning, heat pump, and refrigeration applications when used as pure fluids because their thermodynamic properties are not suitable for all the operating conditions, and therefore some solutions may be found using blends of refrigerants, to satisfy the demand for a wide range of working conditions. The adoption of new mixtures poses the problem of how to extend the correlations developed for pure fluids to the case of flow boiling of mixtures in microchannels. In this work, a mixture of R1234ze(E) and R32 (0.5/0.5 by mass) has been considered: The local heat transfer coefficient during flow boiling of this mixture in a single microchannel with 0.96 mm diameter has been measured at a pressure of 14 bar, which corresponds to a bubble temperature of around 26°C. This flow boiling database, encompassing more than 300 experimental points at different values of mass velocity, heat flux, and vapor quality, is compared with available correlations in the literature. The introduction of a correction to account for the additional mass transfer resistance is discussed, and such correction is found to be necessary and proper to provide a correct sizing of the evaporator.  相似文献   

17.
Experiments are conducted here to investigate how the channel size affects the R-407C saturated flow boiling heat transfer and associated bubble characteristics in a horizontal narrow annular duct. The gap of the duct is fixed at 1.0 and 2.0 mm in this study. The measured data indicate that the saturated flow boiling heat transfer coefficient increases with a decrease in the duct gap. Besides, raising the imposed heat flux can cause a significant increase in the boiling heat transfer coefficients. However, the effects of the refrigerant mass flux and saturated temperature on the boiling heat transfer coefficient are milder. The results from the flow visualization show that the mean diameter of the bubbles departing from the heating surface decreases noticeably at increasing R-407C mass flux. Moreover, the bubble departure frequency increases at reducing duct size and at a high imposed heat flux many bubbles generated from the cavities in the heating surface tend to merge together to form big bubbles. Meanwhile comparison of the present heat transfer data for R-407C with R-134a in the same duct and with some existing correlations is conducted. Furthermore, correlation for the present R-407C saturated flow boiling heat transfer data is proposed. Additionally, the present data for some quantitative bubble characteristics such as the mean bubble departure diameter and frequency and the active nucleation site density are also correlated.  相似文献   

18.
A four-zone flow boiling model is presented to describe saturated flow boiling heat transfer mechanisms in a microchannel of rectangular cross-section. The boiling process in the microchannel is assumed to be a cyclic passage of four zones: (i) liquid-slug zone, (ii) elongated bubble zone, (iii) partially-dryout zone, and (iv) fully-dryout zone. The existence of the partially-dryout zone in this model is proposed to take into consideration of corner effects on boiling heat transfer in the microchannel. To verify this new model, an experimental study was carried out to investigate flow boiling heat transfer of water in a microchannel having a rectangular cross-section with a hydraulic diameter of 137 μm (202 μm in width and 104 μm in depth) with a length of 30 mm under three-side heating condition. The data for bubble nucleation frequency was correlated in terms of the Boiling number, which was used to determine the heat transfer coefficient. It is found that the present four-zone flow boiling model successfully predicts trends of boiling heat transfer data in a microchannel with a rectangular cross-section, having a sharp peak at low vapor quality depending on the mass flow rate. The predictions of flow boiling heat transfer coefficient in the microchannel are found in good agreement with experimental data with a MAE of 13.9%.  相似文献   

19.
Movable Electrical Conducting Probe (MECP), a kind of simple and reliable measuring transducer, used for predicting full-flow-path flow pattern in a boiling vapor/liquid two-phase flow is introduced in this paper. When the test pipe is set at different inclination angles, several kinds of flow patterns, such as bubble, slug, churn, intermittent, and annular flows, may be observed in accordance with the locations of MECP. By means of flow pattern analysis, flow field numerical calculations have been carried out, and heat transfer coefficient correlations along full-flow-path derived. The results show that heat transfer performance of boiling two-phase flow could be significantly augmented as expected in some flow pattern zones.The results of the investigation, measuring techniques and conclusions contained in this paper would be a useful reference in foundational research for prediction of flow pattern and heat transfer behavior in boiling two-phase flow, as well as for turbine vane liquid-cooling design.  相似文献   

20.
A simultaneous visualization and measurement investigation has been carried out on flow boiling of water in parallel silicon microchannels of trapezoidal cross-section. Two sets of parallel microchannels, having hydraulic diameters of 158.8 and 82.8 μm, respectively, were used. The visualization study shows that once boiling heat transfer is established, two-phase flow and single-phase liquid flow appear alternatively with time in the microchannels. Large-amplitude/long-period fluctuations with time in wall temperatures, fluid temperatures, fluid pressures, and fluid mass flux, are measured for the first time during flow boiling in the microchannels. The fluctuation periods are found to be dependent on channel size, heat flux, and mass flux. The mechanism of the periodic boiling fluctuations in this experiment as well as their comparisons with other boiling fluctuations phenomena reported previously, are also discussed. The experimental results confirm that large-amplitude/long-period boiling fluctuations can be sustained when the fluctuations of pressure drop and mass flux have phase differences.With the aid of a microscope and high-speed video recording system, bubbly flow, slug flow, churn flow, and other peculiar flow patterns, are observed during two-phase flow periods in the microchannels.  相似文献   