首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
BACKGROUND AND PURPOSE: Echo contrast agents have been shown to provide conclusive examinations in most patients with insufficient ultrasound penetration through the temporal bone. We investigated the diagnostic value of contrast-enhanced (CE) transcranial color-coded duplex sonography (TCCD) in patients with ischemic cerebrovascular disease and insufficient temporal windows and evaluated TCCD criteria that predict whether CE-TCCD studies may become conclusive. METHODS: Thirty-three patients presenting with ischemic strokes (n = 21) and transient ischemic attacks (n = 12) were investigated. Extracranial color duplex imaging showed normal findings in 24 patients, eight > or = 70% stenoses and one occlusion of the carotid arteries in 8 patients, and severe occlusive disease of both vertebral arteries in 1 patient. Seven carotid stenoses and vertebral artery obstructions were confirmed by angiography. The galactose/palmitic acid-based echo contrast agent was injected intravenously as bolus of 200, 300, or 400 mg/mL in a dosage of 10, 5, and 5 mL, respectively. RESULTS: Thirty-two of the 33 patients were completely examined because 1 patient who felt pain at the injection site declined further investigations. Twenty-one (66%) of 32 CE studies were conclusive and showed cross-flow through three anterior and two posterior communicating arteries, but no stenoses and occlusions. Precontrast identification of any cerebral artery provided an overall accuracy of 97% in predicting a conclusive CE investigation. Precontrast TCCD identified no arterial Doppler signals in patients with inconclusive CE studies. CONCLUSIONS: CE-TCCD provided conclusive examinations in two thirds of patients with ischemic cerebrovascular disease and ultrasound-refractory temporal windows. Precontrast detection of any cerebral artery reliably predicted a conclusive CE investigation.  相似文献   

2.
BACKGROUND AND PURPOSE: It remains uncertain whether the annual stroke risk of 7% to 8% in middle cerebral artery (MCA) stenosis is of embolic or hemodynamic origin. Preliminary reports provide evidence of emboli exiting from acute MCA stenoses, detected by transcranial Doppler (TCD) sonography. With multirange monitoring before and after the stenosis, TCD monitoring may help for the first time to differentiate microemboli exiting from the MCA stenosis from those with a source proximal to the MCA stenosis. We searched for microembolic signals (MES) using multigated monitoring in patients with chronic MCA stenoses. METHODS: Fifty-eight patients with 78 chronic stenoses of the MCA were enrolled in the study. Additional sources of embolism were ruled out by extensive clinical workup. Twenty-four patients were treated with coumarin, whereas 28 patients received aspirin. The remaining 6 patients discontinued their medication after a few weeks. The sample volume of the multirange probe was placed on either side of the stenotic area of the MCA. RESULTS: Twenty-three (29.5%) of the stenoses were low grade, 18 (23%) were moderate, and 37 (47.5%) were severe. Thirty-seven (47%) of the stenoses were symptomatic and 41 (53%) were asymptomatic before study entry. During follow-up, 2 strokes and 7 transient ischemic attacks occurred. Computer tomography revealed two watershed-type infarcts. Sufficient insonation of the prestenotic and poststenotic segments of the MCA was possible in 70 stenoses (90%). No MES could be detected during a total of 1740 minutes' monitoring time distal to the MCA stenoses, regardless of the patients' medication. MES were also absent in the contralateral MCA. CONCLUSIONS: MES are not detectable in patients with chronic MCA stenoses of different degrees. No MES were found in either symptomatic or asymptomatic stenoses, regardless of the patients' medication. These results indicate that chronic MCA stenoses do not represent a significant embolic source. The absence of MES in the prestenotic Doppler sample volume, the watershed-type infarcts during follow-up, and the absence of small-vessel disease on computed tomography suggests that hemodynamic mechanisms are responsible for recurrent cerebral ischemia.  相似文献   

3.
PURPOSE: Advances in cerebral vascular imaging suggest that patients with critical levels of carotid artery stenosis (> 70%) who have symptoms can be identified accurately and necessary information about the intracranial and extracranial circulation obtained before surgery without conventional angiography. We have used carotid duplex imaging in combination with magnetic resonance angiography (MRA) to evaluate 20 patients with symptomatic ipsilateral high-grade carotid stenosis. METHODS: All patients underwent CT and magnetic resonance imaging brain scans, as well as MRA and conventional arteriography of the cerebral circulation. Magnetic resonance angiograms were obtained with two-dimensional phase contrast and time-of-flight techniques. Phase contrast was used for intracranial vascular imaging and for determining qualitative flow velocities and the direction of blood flow in the circle of Willis. Two-dimensional time of flight was used to assess the carotid bifurcations. RESULTS: Twenty patients with symptoms (six with strokes, 11 with transient ischemic attacks, and three with amaurosis fugax) had duplex evidence of high-grade carotid stenoses. Computed tomographic and magnetic resonance brain scans were positive for cerebral infarction in six patients with clinical strokes. Comparison of MRA with conventional angiography was 91% accurate for high-grade stenoses and occlusions (sensitivity 100% and specificity 90% for stenosis; sensitivity/specificity was 100% for complete occlusion). Comparison of duplex imaging with conventional angiography demonstrated 86% accuracy for detection of severe stenosis or occlusion (sensitivity 94% and specificity 89% for stenosis; sensitivity and specificity were 100% for complete occlusion). CONCLUSIONS: This study suggests that combined use of MRA and duplex imaging is accurate for detection and evaluation of high-grade carotid stenoses in patients with symptoms.  相似文献   

4.
BACKGROUND AND PURPOSE: A favorable risk-benefit ratio for warfarin compared with aspirin has been reported for the prevention of major vascular events in symptomatic >/=50% intracranial stenoses. Transcranial color-coded duplex sonography (TCCS) criteria providing an accurate detection of >/=50% and <50% stenoses of the anterior, middle, and posterior cerebral arteries and basilar and vertebral arteries were evaluated retrospectively with angiography used as the standard of reference. METHODS: Prospectively collected TCCS, extracranial color-coded duplex sonography, and intra-arterial digital subtraction angiography data of 310 patients were reviewed. The patients had angiography for confirmation of symptomatic extracranial >/=70% carotid stenoses, symptomatic stenoses (peak systolic velocity higher than the corresponding mean value +2 SDs of 104 normal subjects), and occlusions of the middle cerebral or basilar artery previously assessed by ultrasound. The sonographer was not aware of angiographic findings. RESULTS: TCCS would have detected all 31 of >/=50% intracranial stenoses with 1 false-positive and 35 of 38 <50% stenoses with 3 false-positives. One of 69 stenoses (1%) and 280 of 2741 normal arteries (10%) were missed because of inadequate insonation windows. The corresponding peak systolic velocity cutoffs for >/=50%/<50% stenoses were >/=155/>/=120 cm/s (anterior cerebral artery), >/=220/>/=155 cm/s (middle cerebral artery), >/=145/>/=100 cm/s (posterior cerebral artery), >/=140/>/=100 cm/s (basilar artery), and >/=120/>/=90 cm/s (vertebral artery). CONCLUSIONS: TCCS may reliably assess >/=50% and <50% basal cerebral artery narrowing and prove useful for noninvasive management of patients with symptomatic intracranial stenoses.  相似文献   

5.
OBJECTIVE: We assessed the feasibility of contrast-enhanced color Doppler, power Doppler, and spectral duplex sonography for visualization and quantification of flow through transjugular intrahepatic portosystemic shunts (TIPS) in patients in whom the baseline sonographic evaluation was unsatisfactory. SUBJECTS AND METHODS: Thirty-three patients underwent color Doppler, power Doppler, and spectral duplex sonography after TIPS insertion or before TIPS revision (mean time interval +/- SD, 1 +/- 1 day). All sonograms were obtained before and after patients received echo-enhancing contrast material. Sonography was evaluated with regard to presence or absence of flow in the mid portion, portal segment, and hepatic segment of the shunt. The maximal peak velocity was measured in the mid portion of the shunt. For identifying and quantifying stenoses, the percentage of luminal diameter reduction was calculated at the tightest part of the shunt. Shunt angiography and measurements of portosystemic pressure gradients were independently evaluated and compared with the sonographic findings. RESULTS: Flow visualization on unenhanced color Doppler sonography was significantly improved through the use of power Doppler sonography and contrast-enhanced color Doppler and power Doppler sonography (p < .01). Between contrast-enhanced power Doppler and contrast-enhanced color Doppler sonography, a significant difference was found in the portal and hepatic segments (p < .05). All shunt stenoses (n = 8) and occlusions (n = 3) were revealed by power Doppler sonography, whereas color Doppler sonography failed to reveal six of eight stenoses. Compared with unenhanced sonography, the quality of spectral duplex sonography was improved in eight patients after contrast enhancement (p < .05). Maximal peak velocity ranged from 54 to 252 cm/sec (mean +/- SD, 132.7 +/- 52.1 cm/sec) in normal shunts and from 24.5 to 70.0 cm/sec (mean +/- SD, 45.0 +/- 18.9 cm/sec) in stenosed shunts. No correlation was found between maximal peak velocity and portosystemic pressure gradients (r = .28). CONCLUSION: Unenhanced power Doppler and contrast-enhanced color and power Doppler sonography can be helpful in the assessment of TIPS status in patients who previously underwent unsatisfactory sonography. These techniques may allow anatomic evaluation and quantification of shunt stenosis in most patients. Contrast enhancement may also considerably improve the quality of spectral duplex sonography.  相似文献   

6.
PURPOSE: To compare blood flow velocity changes within the middle cerebral artery (MCA) during hyperventilation, as measured with by both transcranial Doppler sonography and MR imaging, with the diameter of the MCA as measured with MR imaging alone. METHODS: The studies were performed in six healthy volunteers ranging in age from 22 to 31 years (mean, 27 years). Transcranial Doppler sonography was carried out with a range-gated 2-MHz transducer. MR examinations were done on a 1.5-T imaging unit. MR angiography was performed using the time-of-flight technique. MR flow measurements were carried out by using the phase-mapping technique with an ECG-triggered phase-contrast sequence. RESULTS: During hyperventilation, the mean blood flow velocity of the proximal MCA declined by 49.6% +/- 5.7 (mean +/- standard deviation) as measured with Doppler sonography, and by 47% +/- 4.6 as measured with MR flow calculation. The diameter of the MCA (3.4 +/- 0.3 mm) remained unchanged on MR imaging studies (3.3 +/- 0.3 mm). CONCLUSION: We found a good correlation between relative flow velocity changes measured by transcranial Doppler sonography and MR techniques. MR imaging revealed no significant changes in the diameter of the proximal MCA during normal versus hyperventilation. Relative changes in flow velocity in the MCA would thereby reflect relative changes in cerebral blood flow, at least during hyperventilation.  相似文献   

7.
8.
PURPOSE: The purpose was to determine tumor neovascularisation via colour-coded Doppler (duplex) sonography and the "power mode", both visually and quantitatively, by means of videodensitometry. MATERIAL AND METHODS: 6 VX2 tumours of 4 to 11 mm size were implanted in 4 rabbits at various sites. The colour-coded duplex sonography and the new sonographic power technique were tested before and after having injected a new contrast medium (SH U 616A). RESULTS: If no contrast medium was injected, tumour neovascularisation was identified in only 50% of the cases. Injection of contrast medium increased signal intensity three to fourfold with all examined tumors. Combined use of the sonographic method by the power technique with injection of contrast medium is outstandingly suitable for tumor vessel imaging even of small tumors, as these initial results seem to show. CONCLUSION: If these results are corroborated by further studies, contrast-medium supported sonographic technique may possibly become established as an alternative method to other imaging procedures.  相似文献   

9.
BACKGROUND & PURPOSE: This study was performed to determine the usefulness of transcranial color-coded real-time sonography (TCCS) in detecting stenosis in the horizontal portion of the middle cerebral artery (MCA). METHODS: Using TCCS and the incident angle correction technique, we measured the peak-systolic flow velocity in bilateral MCAs in 45 consecutive patients in whom cerebral angiography was carried out within 1 week before or after TCCS. Three patients had a stenosis of 75% or greater and four had a unilateral occlusion of the extracranial internal carotid artery (ICA) (the ICS and ICO groups, respectively). Eight patients had a stenosis of 50% or greater (one bilateral and seven unilateral) (the M1S group). Four patients had unilateral distal occlusion of the horizontal portion of the MCA (the M1O group). Twenty-six patients had no significant extra- or intracranial stenosis on the ipsilateral or contralateral side (the control group). RESULTS: Mean peak-systolic flow velocity on the affected side was 83.0 +/- 20.8 cm/s in the ICS group, 59.8 +/- 23.2 cm/s in the ICO group, and 62.3 +/- 33.7 cm/s in the M1O group. In the control group, the mean peak-systolic flow velocity was 116.0 +/- 31.5 cm/s. In the M1S group, however, the mean peak-systolic flow velocity (334.2 +/- 35.7 cm/s) on the affected side always exceeded 180 cm/s (mean value +/- 2 SD in the control group), and was significantly higher than that in the other groups. The mean peak-systolic flow velocity in the M1S group increased with the grade of stenosis. CONCLUSION: The M1S group members could easily be distinguished from the other group members by their peak-systolic flow velocity in excess of 180 cm/s. Measurement of the peak-systolic flow velocity of the MCA by TCCS may help to identify a significant stenosis in the horizontal portion of the MCA.  相似文献   

10.
BACKGROUND AND PURPOSE: Two surgical trials established that carotid endarterectomy is beneficial to symptomatic patients who have a severe internal carotid artery (ICA) stenosis on angiograms. Duplex ultrasonography-derived hemodynamic parameters show a good correlation with angiography and are often used for detecting severe ICA stenoses. However, duplex performance is ultrasound machine and operator dependent. Over time both may change, possibly affecting duplex performance. We compared duplex performance of 2 time periods in 1 specific vascular laboratory using angiography as the gold standard. METHODS: Consecutive patients who underwent both angiography and duplex examinations of the ICA were evaluated (first period, 60 patients; second period, 61 patients). Peak systolic velocity and several other hemodynamic parameters and ratios were analyzed by receiver operating characteristic curves in their ability to detect severe ICA stenoses. The optimal parameter and threshold were determined for each period. Subsequently, duplex test characteristics were compared after the optimal thresholds of both the first and the second periods were applied in the second period. RESULTS: In both periods peak systolic velocity of the ICA was the best test parameter; areas under the receiver operating characteristic curve were similar (0.957 and 0.954, respectively). However, the optimal threshold was different. The optimal threshold in the second period was 270 cm/s. When the optimal threshold of 210 cm/s of the first period was applied in the second period, test characteristics changed significantly. Sensitivity increased from 98% to 100%, and specificity decreased from 85% to 71% (P=0.004). CONCLUSIONS: The optimal threshold for detecting severe ICA stenoses with duplex ultrasonography in our laboratory changed over time. Individual laboratories should assess duplex accuracy regularly and adjust adopted criteria if necessary to keep diagnostic performance optimal.  相似文献   

11.
Transcranial color-coded real-time sonography (TCCS) and cranial computed tomography were applied to patients with middle cerebral artery (MCA) stenosis to evaluate whether these techniques may disclose additional aspects of the pathophysiology of the stenotic lesion. In 15 patients with MCA stenosis identified by transcranial Doppler sonography, the echogenicity of the stenotic segment was estimated subjectively by TCCS. The density of the stenotic segment, prior to being detected by TCCS, was quantified by computed tomography. In 5 of the 15 patients, transcranial image-directed Doppler sonography identified a hyperechogenic lesion in association with the stenotic vascular segment; computed tomography demonstrated a "dense" artery (Hounsfield units [HU] > 120) in the corresponding vascular segment. In 10 patients the echogenicity of the stenotic segment was found to be normal, with a computed tomography density of < 100 HU in the corresponding segment. Hyperechogenic and hyperdense stenotic vascular segments in TCCS and computed tomography, respectively, may indicate an arteriosclerotic vascular lesion with calcium deposits. Normal echogenicity and normal to slightly elevated computed tomography-density of a stenotic vascular segment may suggest the presence of a thrombotic/embolic lesion.  相似文献   

12.
The practical application of colour-coded duplex sonography shows that physico-technical artifacts of colour Doppler imaging may not be obvious in all cases and can lead to misinterpretation. Slice-thickness artifacts are due to restricted transversal resolution, as in the B-mode, and may cause false negative results in vascular occlusions. Specific problems in creating and processing the colour flow image interfere with lateral resolution and lead to errors in the quantification of stenoses from the colour Doppler image. Mirror image artifacts produce phantom pictures that can be easily identified as such in some cases, but may resemble recesses in the arterial wall in other cases. Phenomena of sound shadowing resulting from the same reasons as in B-mode may lead to assume vascular occlusions in cases of long-range stenoses. Artifacts of the sonication angle in case of blood vessel tortuosity may lead to misdiagnosis of a non-existent retrograde flow. The artifacts mentioned do restrict the capacity of colour coded duplex sonography for localising flow in the ultrasound image. Users of the method should therefore be familiar with these artifacts.  相似文献   

13.
The effect on the middle cerebral artery blood flow velocity (VMCA) of moderate and hard physical exercise on an ergometer cycle was examined in 10 healthy volunteers using transcranial Doppler sonography (TCD). During exercise, the heart rate increased by 136% and the systolic blood pressure by 37% (mean values). During initial moderate exercise, VMCA increased by 51%; in a following period of maximal physical work, VMCA decreased again by 20% in 9 of 10 volunteers although the heart rate continued to increase by 10% and the systolic blood pressure by 5% (mean values). Constriction of the MCA may explain the initial increase of VMCA, suggesting a role for large cerebral arteries in autoregulation. Our data indicate that the subsequent decrease of VMCA is caused by arteriolar constriction, a likely cause of which was hyperventilation during the excessive work period.  相似文献   

14.
The evidence in support of surveillance has been principally based on the favourable primary-assisted patency of stenosed grafts following revision (60-80% at 5 years) compared with the poor secondary patency of revised occluded grafts (20-40% at 5 years). Both the capital cost and workload generated by surveillance are considerable. More information is needed on the benefits of surveillance compared with clinical follow-up. A retrospective comparison of 50 vein grafts (44 reversed, six in situ) undergoing colour-coded duplex surveillance and 50 vein grafts (46 reversed, four in situ) under clinical follow-up, with duplex scans obtained only when clinically indicated, has been performed. Four (8%) stenoses of > or = 50% were identified in the surveillance group. One 50% proximal anastomotic stenosis failed to progress on sequential scans. Three stenoses were treated (one mid graft, two popliteal) by vein patch angioplasty (two cases) and transluminal angioplasty (one case). Both groups were followed-up for 12 months. Secondary patency at 12 months (88% surveillance; 80% clinical follow-up) was not significantly different (P = 0.3). Similarly, limb salvage at 12 months (94% surveillance; 88% controls) was not significantly different (P = 0.4). A large randomized prospective study comparing duplex surveillance and clinical follow-up is warranted.  相似文献   

15.
BACKGROUND AND PURPOSE: The wide application of embolization in the treatment of aneurysms has created the need for an intraprocedural means to anticipate a poor outcome by monitoring hemodynamic changes in the brain. METHODS: Transcranial Doppler sonography was used to monitor flow velocity in the middle cerebral artery (MCA) in 23 patients undergoing embolization with Guglielmi detachable coils (GDCs) of either incidental or symptomatic intracranial aneurysms. Sonographic values were recorded from the ipsilateral MCA at the beginning, middle, and end of the interventional procedure and 24 hours afterward. RESULTS: No complications occurred in 15 patients. In these cases, sonography showed an average decrease in MCA flow velocity of 2.7% after GDC application, returning to baseline at the end of treatment and then increasing by about 17% 24 hours later. In four patients with vasospasm on posttreatment angiograms, MCA flow velocity increased to values higher than 120 cm/s after GDC application, returning to baseline after 24 hours. In four patients with ischemic complications (two transient ischemic attacks, one stroke, one vascular death), MCA flow velocity decreased more than 30% and did not return to preoperative values within 24 hours. CONCLUSION: The application of transcranial Doppler sonographic monitoring during endovascular treatment may help to identify patients at risk for posttreatment cerebral ischemia.  相似文献   

16.
PURPOSE: We studied the influence of age on the utility of carotid sonography in patients with transient ischemic attacks and strokes. METHODS: The results of Doppler ultrasound examinations of the carotid arteries in 613 consecutive patients with transient ischemic attacks (n = 450) or strokes (n = 163) were analyzed for different age groups. For each patient, the grade of stenosis was scored for the ipsilateral internal carotid artery. The results of the ultrasound examinations were correlated with angiographic findings and findings at endarterectomy. The extent of atherosclerosis for each age group was expressed as the ratio between the number of grade II-IV stenoses (> or = 50%) in the carotid arteries and the number of patients in that group ("atherosclerosis ratio"). RESULTS: Under the age of 40 years, high-grade atherosclerotic stenoses were not found. However, 3 relatively young patients had dissections of the internal carotid arteries. The atherosclerosis ratio exceeded 0.5 for age groups 65-69 years through 80+ years. Among the patients with high-grade stenoses, ischemic heart disease prevented endarterectomy in 63% of patients in age group 80+ years, 44% in age group 75-79 years, and 26% in age group 70-74 years. CONCLUSIONS: Carotid sonography did not detect any significant atherosclerotic changes in young patients but was useful for diagnosing other etiologies of ischemic cerebral disease, eg, carotid dissection. At the other end of the spectrum, the impact of carotid sonography on patient management appears to be limited in patients over the age of 70 years. Carotid sonography seems to be most useful for patients 40-69 years old.  相似文献   

17.
PURPOSE: The purpose of this study was to assess the impact of arteriovenous fistulas combined with varying degrees of stenosis on distal bypass hemodynamics and Doppler spectral parameters. METHODS: In an in vitro flow model bypass stenoses causing 30%, 55%, and 70% diameter reduction were induced 10 cm upstream of a fistula with low outflow resistance. Flow and intraluminal pressure were measured proximal to the stenosis and downstream of the fistula. The waveform parameters peak systolic velocity, end-diastolic velocity, pulsatility index, and pulse rise time were determined from midstream Doppler spectra obtained 10 cm downstream of the fistula. All measurements were carried out with open and clamped fistula. RESULTS: At 30% diameter reducing stenosis opening of the fistula induced a 12% systolic pressure drop across the stenosis but had no adverse effect on the Doppler waveform parameters. At 55% stenosis the pressure drop increased from 16% to 31% after fistula opening. This increased pressure drop was associated with a further reduction in peak systolic velocity, a decrease in pulsatility index, and an enhanced pulse rise time prolongation. Fistula opening at 70% stenosis increased the systolic pressure drop from 31% to 48% and had significant impact on all waveform parameters. CONCLUSIONS: Distal arteriovenous fistulas enhance pressure loss across stenoses and affect downstream velocity waveform configuration. The presence of a combined fistula and a stenosis mimics the distal hemodynamic conditions of a more severe stenosis. Assessment of the hemodynamic impact of fistulas must be undertaken in the evaluation of in situ vein bypass stenoses.  相似文献   

18.
PURPOSE: To assess iliac artery stenosis before and up to 1 year after percutaneous transluminal angioplasty (PTA) with duplex ultrasound (DUS) to determine the incidence of residual and recurrent stenoses and correlate these findings to clinical outcome. PATIENTS AND METHODS: Sixty-one patients with 70 iliac artery segments treated with PTA were examined. The peak systolic velocity (PSV) ratio (PSV ratio = PSV in stenosis divided by PSV proximal or distal to stenosis) was determined by DUS before PTA and 1 day, 3 months and 1 year after PTA. Three categories of results were identified by using PSV ratios at the site of the treated stenosis 1 day and 1 year after PTA (good result, residual stenosis, and recurrent stenosis). The DUS-determined anatomic result was correlated with the clinical outcome at 1 year. Clinical outcome was classified according to Society for Vascular Surgery/International Society for Cardiovascular Surgery (SVS/ISCVS) criteria. RESULTS: Good results with DUS (PSV ratio 1 day and 1 year after PTA > or = to 2.5) were found in 45 of 70 segments (64.3%), residual stenoses (PSV ratio > or .5 1 day after PTA) in 15 of 70 segments (21.4%), and recurrent stenosis (PSV ratio 1 day after PTA < 2.5 and 1 year after PTA > or = 2.5) in 10 of 70 segments (14.3%). PSV ratios of residual stenoses decreased significantly between 1 day and 1 year after PTA because some residual stenoses improved hemodynamically in time. Clinical results were significantly better in patients with a good result compared with other patients. However, the clinical outcome of patients with residual stenoses was not significantly different from the patients with good DUS results. CONCLUSION: Some residual stenoses improved sonographically after PTA. Clinical results at 1 year are highly variable within different groups. Clinical outcome of patients with residual stenoses did not differ from patients with good DUS results, whereas clinical outcome in patients with recurrent stenoses was worse than in the other groups.  相似文献   

19.
PURPOSE: The purpose of this study was to evaluate the stenosis-free patency of open repair (vein-patch angioplasty, interposition, jump grafting) and percutaneous transluminal balloon angioplasty (PTA) of 144 vein graft stenoses that were detected during duplex scan surveillance after infrainguinal vein bypass grafting. METHODS: Patients who underwent revision of an infrainguinal vein bypass graft were analyzed for type of vein conduit, vascular laboratory findings leading to revision, repair techniques, assisted graft patency rate, procedure mortality rate, and restenosis of the repair site. RESULTS: The time of postoperative revision ranged from 1 day to 133 months (mean, 13 months). One hundred eighteen primary and 26 recurrent stenoses (peak systolic velocity, >300 cm/s) in 52 tibial and 35 popliteal vein bypass grafts were identified by means of duplex scanning. The repairs consisted of 77 open procedures (vein-patch angioplasty, 28; vein interposition, 33; jump graft, 9; primary repair, 3) and 67 PTAs. No patient died as a result of intervention. Cumulative assisted graft patency rate (life-table analysis) was 91% at 1 year and 80% at 3 years. At 2 years, cumulative assisted graft patency rate was comparable for saphenous vein grafts (reversed, 94%; in situ, 88%; nonreversed, 63%) and alternative vein grafts (89%). Stenosis-free patency rate at 2 years was identical (P =.55) for surgical intervention (63%) and endovascular intervention (63%) but varied with type of surgical revision (P =.04) and time of intervention (<4 months, 45%; >4 months, 71%; P =.006). The use of duplex scan-monitored PTA to treat focal stenoses (<2 cm) and late-appearing stenoses (>3 months) was associated with a stenosis-free patency rate that was 89% at 1 year. After intervention, the alternative vein bypass grafts necessitated twice the reinterventions per month of graft survival (P =.01). Bypass graft to the popliteal versus infrageniculate arteries, site of graft stenosis (vein conduit, anastomotic region), and repair of a primary versus a recurrent stenosis did not influence the outcome after intervention. CONCLUSION: The revision of duplex scan-detected vein graft stenosis with surgical or endovascular techniques was associated with an excellent patency rate, including when intervention on alternative vein conduits or treatment of restenosis was necessary. When PTA was selected on the basis of clinical and duplex scan selection criteria, the endovascular treatment of focal vein graft stenosis was effective, durable, and comparable with the surgical revision of more extensive lesions.  相似文献   

20.
Three surgeons performed 180 atherectomy procedures in 161 patients using the Transluminal Extraction Catheter in 144 and the Auth Rotablator in 36. The primary patency rate was 55% at 1 year and 46% at 2 years, and failure was caused by stenosis in 28 (15.6%) and occlusion in 61 (33.7%) limbs. Multivariate Cox regression analysis showed significantly better outcome if the indication was claudication, the lesion was short or there was associated stenting. Vascular laboratory surveillance was performed in 93 limbs in 83 patients. Cox regression analysis in this subgroup also showed a significant relationship between outcome and the maximum peak systolic velocity from a duplex scan at the last study performed. Receiver operating characteristics curves showed that a raised maximum peak systolic velocity best predicted late failure (sensitivity 84%, specificity 66% for > 200 cm/s; sensitivity 72%, specificity 84% for > 250 cm/s); the velocity ratio at the stenosis to that in the segment above or the resting ankle/brachial pressure index were less predictive. For 50 procedures studied in the vascular laboratory which remained successful to the end of the study, maximum peak systolic velocities were > 250 cm/s from the first postoperative study, suggesting residual stenosis in 6%, or increased to become > 250 cm/s by the last study, suggesting recurrent stenoses in 12%. For 43 procedures which were studied and later failed, velocities were > 250 cm/s from the first test in 26% or increased to > 250 cm/s by the last test before failure in 40%. Vascular laboratory surveillance helps to predict outcome after atherectomy. Failure may be a result of residual disease from the time of the procedure or from restenosis. The apparent high incidence of clinically manifest or developing stenoses raises doubts as to the benefit of atherectomy over balloon dilatation alone.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号