首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The cross flow from channel to channel through gas diffusion layer (GDL) under the land could play an important role for water removal in proton exchange membrane (PEM) fuel cells. In this study, characteristics of liquid water removal from GDL have been investigated experimentally, through measuring unsteady pressure drop in a cell which has the GDL initially wet with liquid water. The thickness of GDL is carefully controlled by inserting various thicknesses of metal shims between the plates. It has been found that severe compression of GDL could result in excessive pressure drop from channel inlet to channel outlet. Removing liquid water from GDL by cross flow is difficult for GDL with high compression levels and for low inlet air flow rates. However, effective water removal can still be achieved at high compression levels of GDL if the inlet air flow rate is high. Based on different compressed GDL thicknesses, different GDL porosities and permeabilities were calculated and their effects on the characteristics of liquid water removal from GDL were evaluated. Visualization of liquid water transport has been conducted by using transparent flow channel, and liquid water removal from GDL under the land was observed for all the tested inlet air flow rates, which confirms that cross flow is practically effective to remove the liquid water accumulated in GDL under the land area.  相似文献   

2.
The water management in the air flow channel of a proton exchange membrane (PEM) fuel cell cathode is numerically investigated using the FLUENT software package. By enabling the volume of fraction (VOF) model, the air–water two-phase flow can be simulated under different operating conditions. The effects of channel surface hydrophilicity, channel geometry, and air inlet velocity on water behavior, water content inside the channel, and two-phase pressure drop are discussed in detail. The results of the quasi-steady-state simulations show that: (1) the hydrophilicity of reactant flow channel surface is critical for water management in order to facilitate water transport along channel surfaces or edges; (2) hydrophilic surfaces also increase pressure drop due to liquid water spreading; (3) a sharp corner channel design could benefit water management because it facilitates water accumulation and provides paths for water transport along channel surface opposite to gas diffusion layer; (4) the two-phase pressure drop inside the air flow channel increases almost linearly with increasing air inlet velocity.  相似文献   

3.
It has been reported recently that water flooding in the cathode gas channel has significant effects on the characteristics of a proton exchange membrane fuel cell. A better understanding of this phenomenon with the aid of an accurate model is necessary for improving the water management and performance of fuel cell. However, this phenomenon is often not considered in the previous one-dimensional models where zero or a constant liquid water saturation level is assumed at the interface between gas diffusion layer and gas channel. In view of this, a one-dimensional fuel cell model that includes the effects of two-phase flow in the gas channel is proposed. The liquid water saturation along the cathode gas channel is estimated by adopting Darcy’s law to describe the convective flow of liquid water under various inlet conditions, i.e. air pressure, relative humidity and air stoichiometry. The averaged capillary pressure of gas channel calculated from the liquid water saturation is used as the boundary value at the interface to couple the cathode gas channel model to the membrane electrode assembly model. Through the coupling of the two modeling domains, the water distribution inside the membrane electrode assembly is associated with the inlet conditions. The simulation results, which are verified against experimental data and simulation results from a published computational fluid dynamics model, indicate that the effects of relative humidity and stoichiometry of inlet air are crucial to the overall fuel cell performance. The proposed model gives a more accurate treatment of the water transport in the cathode region, which enables an improved water management through an understanding of the effects of inlet conditions on the fuel cell performance.  相似文献   

4.
Air-delivery is typically the largest parasitic loss in PEM fuel cell systems. We develop a passive water management system that minimizes this loss by enabling stable, flood-free performance in parallel channel architectures, at very low air stoichiometries. Our system employs in situ-polymerized wicks which conform to and coat cathode flow field channel walls, thereby spatially defining regions for water and air transport. We first present the fabrication procedure, which incorporates a flow field plate geometry comparable to many state-of-the-art architectures (e.g., stamped metal or injection molded flow fields). We then experimentally compare water management flow field performance versus a control case with no wick integration. At the very low air stoichiometry of 1.15, our system delivers a peak power density of 0.68 W cm−2. This represents a 62% increase in peak power over the control case. The open channel and manifold geometries are identical for both cases, and we demonstrate near identical inlet-to-outlet cathode pressure drops at all fuel cell operating points. Our water management system therefore achieves significant performance enhancement without introducing additional parasitic losses.  相似文献   

5.
Jixin Chen   《Journal of power sources》2010,195(4):1177-1181
In this work, a transparent assembly was self-designed and manufactured to perform ex situ experimental study on the liquid water removal characteristics in PEM fuel cell parallel flow channels. It was found that the dominant frequency of the pressure drop across the flow channels may be utilized as an effective diagnostic tool for water removal. Peaks higher than 1 Hz in dominant frequency profile indicated water droplet removals at the outlet, whereas relatively lower peaks (between 0.3 and 0.8 Hz) corresponded to water stream removals. The pressure drop signal, although correlated with the water removal at the outlet, was readily influenced by the two phase flow transport in channel, particularly at high air flow rates. The real-time visualization images were presented to show a typical water droplet removal process. The findings suggest that dominant frequency of pressure drop signal may substitute pressure drop as a more effective and reliable diagnostic tool for water removal in PEM fuel cell flow channels.  相似文献   

6.
Effects of active area size on steady-state characteristics of a working PEM fuel cell, including local current densities, local oxygen transport rates, and liquid water transport were studied by applying a three-dimensional, two-phase PEM fuel cell model. The PEM fuel cells were with parallel, interdigitated, and serpentine flow channel design. At high operating voltages, the size effects on cell performance are not noticeable owing to the occurrence of oxygen supply limit. The electrochemical reaction rates are high at low operating voltages, producing large quantity of water, whose removal capability is significantly affected by flow channel design. The cells with long parallel flow field experience easy water accumulation, thereby presenting low oxygen transport rate and low current density. The cells with interdigitated and serpentine flow fields generate forced convection stream to improve reactant transport and liquid water removal, thereby leading to enhanced cell performance and different size effect from the parallel flow cells. Increase in active area significantly improves performance for serpentine cells, but only has limited effect on that of interdigitated cells. Size effects of pressure drop over the PEM cells were also discussed.  相似文献   

7.
A small single-channel fuel cell prototype was built with the objective of monitoring the appearance and transport of water droplets in the gas channels in usual operating conditions. It allows the simultaneous observation of droplets and of their local effects on current density. The first results show that the air flow rate seems to control the transition between two different water removal mechanisms: a plug flow when the air stoichiometry is low, with significant disturbances in the local current density, pressure drop and fuel cell performance, and a more conventional flow with steadier removal of smaller droplets when the stoichiometry is higher.  相似文献   

8.
Water flooding is detrimental to the performance of the proton exchange membrane fuel cell (PEMFC) and therefore it has to be addressed. To better understand how liquid water affects the fuel cell performance, direct visualisation of liquid water in the flow channels of a transparent PEMFC is performed under different operating conditions. Two high-resolution digital cameras were simultaneously used for recording and capturing the images at the anode and cathode flow channels. A new parameter extracted from the captured images, namely the wetted bend ratio, has been introduced as an indicator of the amount of liquid water present at the flow channel. This parameter, along with another previously used parameter (wetted area ratio), has been used to explain the variation in the fuel cell performance as the operating conditions of flow rates, operating pressure and relative humidity change. The results have shown that, except for hydrogen flow rate, the wetted bend ratio strongly linked to the operating condition of the fuel cell; namely: the wetted bend ratio was found to increase with decreasing air flow rate, increasing operating pressure and increasing relative humidity. Also, the status of liquid water at the anode was found to be similar to that at the cathode for most of the cases and therefore the water dynamics at the anode side can also be used to explain the relationships between the fuel cell performance and the investigated operating conditions.  相似文献   

9.
Air delivery is typically the greatest parasitic power loss in polymer electrolyte membrane fuel cell (PEMFC) systems. We here present a detailed study of an active water management system for PEMFCs, which uses a hydrophilic, porous cathode flow field, and an electroosmotic (EO) pump for water removal. This active pumping of liquid water allows for stable operation with relatively low air flow rates and low air pressure and parallel cathode channel architectures. We characterize in-plane transport issues and power distributions using a three by three segmented PEMFC design. Our transient and steady state data provide insight into the dynamics and spatial distribution of flooding and flood-recovery processes. Segment-specific polarization curves reveal that the combination of a wick and an EO pump can effect a steady state, uniform current distribution for a parallel channel cathode flow field, even at low air stoichiometries (αair = 1.5). The segmented cell measurements also reveal the mechanisms and dynamics associated with EO pump based recovery from catastrophic flooding. For most operating regimes, the EO pump requires less than 1% of the fuel cell power to recover from near-catastrophic flooding, prevent flooding, and extend the current density operation range.  相似文献   

10.
The cathode flow-field design of a polymer electrolyte membrane (PEM) fuel cell is crucial to its performance, because it determines the distribution of reactants and the removal of liquid water from the fuel cell. In this study, the cathode flow-field of a parallel flow-field PEM fuel cell was optimized using a sub-channel. The main-channel was fed with moist air, whereas the sub-channel was fed with dry air. The influences of the sub-channel flow rate (SFR, the amount of air from the sub-channel inlet as a percentage of the total cathode flow rate) and the inlet positions (SIP, where the sub-channel inlets were placed along the cathode channel) on fuel cell performance were numerically evaluated using a three-dimensional, two-phase fuel cell model. The results indicated that the SFR and SIP had significant impacts on the distribution of the feed air, removal of liquid water, and fuel cell performance. It was found that when the SIP was located at about 30% along the length of the channel from main-channel inlet and the SFR was about 70%, the PEM fuel cell exhibited much better performance than seen with a conventional design.  相似文献   

11.
Flow maldistribution usually happens in PEM fuel cells when using common inlet and exit headers to supply reactant gases to multiple channels. As a result, some channels are flooded with more water and have less air flow while other channels are filled with less water but have excessive air flow. To investigate the impact of two-phase flow maldistribution on PEM fuel cell performance, a Volume of Fluid (VOF) model coupled with a 1D MEA model was employed to simulate two parallel channels. The slug flow pattern is mainly observed in the flow channels under different flow maldistribution conditions, and it significantly increases the gas diffusion layer (GDL) surface water coverage over the whole range of simulated current densities, which directly leads to poor fuel cell performance. Therefore, it is recommended that liquid and gas flow maldistribution in parallel channels should be avoided if possible over the whole range of operation. Increasing the gas stoichiometric flow ratio is not an effective method to mitigate the gas flow maldistribution, but adding a gas inlet resistance to the flow channel is effective in mitigating maldistribution. With a carefully selected value of the flow resistance coefficient, both the fuel cell performance and the gas flow distribution can be significantly improved without causing too much extra pressure drop.  相似文献   

12.
This paper presents an experimental study and model validation of an external membrane humidifier for PEM fuel cell humidification control. Membrane humidification behavior was investigated with steady-state and dynamic tests. Steady-state test results show that the membrane vapor transfer rate increases significantly with water channel temperature, air channel temperature, and air flow rate. Water channel pressure has little effect on the vapor transfer rate and thus can be neglected in the system modeling. Dynamic test results reveal that the membrane humidifier has a non-minimum phase (NMP) behavior, which presents extra challenges for control system design. Based on the test data, a new water vapor transfer coefficient for Nafion membrane was obtained. This coefficient increases exponentially with the membrane temperature. The test results were also used to validate a thermodynamic model for membrane humidification. It is shown that the model prediction agrees well with the experimental results. The validated model provides an important tool for external humidifier design and fuel cell humidification control.  相似文献   

13.
The operating and designing parameters have significant influences on the performance of an air-cooled proton exchange membrane fuel cell. Figuring out the parameter sensitivity helps select the appropriate operating point and the geometry size for a fuel cell. In this paper, parameter sensitivity analysis is conducted for the performance and the internal transport phenomena of an air-cooled proton exchange membrane fuel cell based on different air stoichiometries, air relative humidities and air flow field designs. The numerical results show that large air stoichiometry helps lower the single cell temperature, keeps the membrane better hydrated, and improves cell performance. Especially, the fluctuation of water content always exists periodically for the case of different air stoichiometry, where the minimum value of water content appears underneath the cathode channel in contrast to the maximum value appearing underneath the cathode rib. Furthermore, the maximum periodic fluctuation amplitude of water content is even more than 8 for the case of air stoichiometry of 150. The water flooding phenomenon becomes severe with the increase of air stoichiometry. Air with larger relative humidity also increases the single cell performance by improving the hydration of the membrane. However, water flooding becomes worse with the increment of air relative humidity. The narrower channel design for the cathode flow field not only leads to a more uniform current density distribution but also keeps the membrane better hydrated and thus enhances the cell performance.  相似文献   

14.
《Journal of power sources》2006,154(1):124-137
Water management in a proton exchange membrane (PEM) fuel cell stack has been a challenging issue on the road to commercialization. This paper presents a numerical investigation of air–water flow in parallel serpentine channels on cathode side of a PEM fuel cell stack by use of the commercial Computational Fluid Dynamics (CFD) software package FLUENT. Different air–water flow behaviours inside the serpentine flow channels with inlet and outlet manifolds were discussed. The results showed that there were significant variations of water distribution and pressure drop in different cells at different times. The “collecting-and-separating effect” due to the serpentine shape of the gas flow channels, the pressure drop change due to the water distribution inside the inlet and outlet manifolds were observed. Several gas flow problems of this type of parallel serpentine channels were identified and useful suggestions were given through investigating the flow patterns inside the channels and manifolds.  相似文献   

15.
This work examines the effect of fuel delivery configuration on the performance of a passive air-breathing direct methanol fuel cell (DMFC). The performance of a single cell is evaluated while the methanol vapour is supplied through a flow channel from a methanol reservoir connected to the anode. The oxygen is supplied from the ambient air to the cathode via natural convection. The fuel cell employs parallel channel configurations or open chamber configurations for methanol vapour feeding. The opening ratio of the flow channel and the flow channel configuration is changed. The opening ratio is defined as that between the area of the inlet port and the area of the outlet port. The chamber configuration is preferred for optimum fuel feeding. The best performance of the fuel cell is obtained when the opening ratio is 0.8 in the chamber configuration. Under these conditions, the peak power is 10.2 mW cm−2 at room temperature and ambient pressure. Consequently, passive DMFCs using methanol vapour require sufficient methanol vapour feeding through the flow channel at the anode for best performance. The mediocre performance of a passive DMFC with a channel configuration is attributed to the low differential pressure and insufficient supply of methanol vapour.  相似文献   

16.
A proton exchange membrane (PEM) fuel cell has many distinctive features which make it an attractive alternative clean energy source. Some of those features are low start-up, high power density, high efficiency and remote applications. In the present study, a numerical investigation was conducted to analyse the flow field and reactant gas distribution in a PEM fuel cell channel with transversely inserted pin fins in the channel flow aimed at improving reactant gas distribution. A fin configuration of small hydraulic diameter was employed to minimise the additional pressure drop. The influence of the pin fin parameters, the flow Reynolds number, the gas diffusion layer (GDL) porosity on the reactant gas transport and the pressure drop across the channel length were explored. The parameters examined were optimized using a mathematical optimization code integrated with a commercial computational fluid dynamics code. The results obtained indicate that a pin fin insert in the channel flow considerably improves fuel cell performance and that optimal pin fin geometries exist for minimized pressure drop along the fuel channel for the fuel cell model considered. The results obtained provide a novel approach for improving the design of fuel cells for optimal performance.  相似文献   

17.
The configuration of fuel, air, and cooling water paths is one of the major factors that influence the performance of a proton exchange membrane fuel cell (PEMFC). In order to investigate the effects of these factors, a quasi-three-dimensional dynamic model of a PEMFC has been developed. For validation, simulation results are compared with experimental data in one-flow configuration case and show good agreement with the experimental cell performance data. Five different flow configurations are then simulated to systematically investigate the effects of fuel, air, and cooling channel configuration on the local current and species distribution. Voltage and power vs. current density for five different configurations are compared. The type 1 configuration, which has a fuel–air counter flow and an air-coolant co-flow, has the highest performance in all ranges of current density because the membrane remains the most hydrated. When the operating current density increases, the effects of temperature on membrane hydration slightly decrease. It is confirmed that fuel cell performance improves with increased humidity until flooding conditions appear. An interesting result shows that it is possible to lower the fuel cell operating temperature to improve fuel cell hydration, which in turn improves cell performance. In addition, the different flow configurations are shown to have an effect on the pressure losses and local current density, membrane hydration, and species mole fractions. These results suggest that the model can be used to optimize the flow configuration of a PEMFC.  相似文献   

18.
A serpentine flow channel is one of the most common and practical channel layouts for a polymer electrolyte membrane (PEM) fuel cell since it ensures the removal of water produced in a cell with acceptable parasitic load. During the reactant flows along the flow channel, it can also leak or cross to neighboring channel via the porous gas diffusion layer due to the high pressure gradient caused by the short distance. Such a cross flow leads to a larger effective flow area altering reactant flow in the flow channel so that the resultant pressure and flow distributions are substantially different from that without considering cross flow, even though this cross flow has largely been ignored in previous studies. In this work, a numerical and experimental study has been carried out to investigate the cross flow in a PEM fuel cell. Experimental measurements revealed that the pressure drop in a PEM fuel cell is significantly lower than that without cross flow. Three-dimensional numerical simulation has been performed for wide ranges of flow rate, permeability and thickness of gas diffusion layer to analyze the effects of those parameters on the resultant cross flow and the pressure drop of the reactant streams. Considerable amount of cross flow through gas diffusion layer has been found in flow simulation and its effect on pressure drop becomes more significant as the permeability and the thickness of gas diffusion layer are increased. The effects of this phenomenon are also crucial for effective water removal from the porous electrode structure and for estimating pumping energy requirement in a PEM fuel cell, it cannot be neglected for the analysis, simulation, design, operation and performance optimization of practical PEM fuel cells.  相似文献   

19.
The cross flow in the under‐land gas diffusion layer (GDL) between 2 adjacent channels plays an important role on water transport in proton exchange membrane fuel cell. A 3‐dimensional (3D) two‐phase model that is based on volume of fluid is developed to study the liquid water‐air cross flow within the GDL between 2 adjacent channels. By considering the detailed GDL microstructures, various types of air‐water cross flows are investigated by 3D numerical simulation. Liquid water at 4 locations is studied, including droplets at the GDL surface and liquid at the GDL‐catalyst layer interface. It is found that the water droplet at the higher‐pressure channel corner is easier to be removed by cross flow compared with droplets at other locations. Large pressure difference Δp facilitates the faster water removal from the higher‐pressure channel. The contact angle of the GDL fiber is the key parameter that determines the cross flow of the droplet in the higher‐pressure channel. It is observed that the droplet in the higher‐pressure channel is difficult to flow through the hydrophobic GDL. Numerical simulations are also performed to investigate the water emerging process from different pores of the GDL bottom. It is found that the amount of liquid water removed by cross flow mainly depends on the pore's location, and the water under the land is removed entirely into the lower‐pressure channel by cross flow.  相似文献   

20.
Bipolar plates include separate gas flow channels for anode and cathode electrodes of a fuel cell. These gases flow channels supply reactant gasses as well as remove products from the cathode side of the fuel cell. Fluid flow, heat and mass transport processes in these channels have significant effect on fuel cell performance, particularly to the mass transport losses. The design of the bipolar plates should minimize plate thickness for low volume and mass. Additionally, contact faces should provide a high degree of surface uniformity for low thermal and electrical contact resistances. Finally, the flow fields should provide for efficient heat and mass transport processes with reduced pressure drops. In this study, bipolar plates with different serpentine flow channel configurations are analyzed using computational fluid dynamics modeling. Flow characteristics including variation of pressure in the flow channel across the bipolar plate are presented. Pressure drop characteristics for different flow channel designs are compared. Results show that with increased number of parallel channels and smaller sizes, a more effective contact surface area along with decreased pressured drop can be achieved. Correlations of such entrance region coefficients will be useful for the PEM fuel cell simulation model to evaluate the affects of the bipolar plate design on mass transfer loss and hence on the total current and power density of the fuel cell.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号