1.
This article presents and discusses the results of an exergy analysis conducted during the operation of a test-bed hybrid wind/solar generator with hydrogen support, designed and constructed at the Industrial Engineering School of the University of Extremadura, Badajoz (Spain). An exergy analysis is made of the different components of the system, calculating their exergy efficiencies and exergy losses, and proposing future improvements to increase the efficiency of the use of the surplus energy produced by the wind/solar generator. The results show the electrolyzer to have an acceptable efficiency (ηex = 68.75%), but the photovoltaic modules a low exergy efficiency (ηex = 8.39%) as also is the case, though to a lesser extent, for the fuel cell (ηex = 35.9%).  相似文献   

2.
We present the results of an analysis of the performance of a photovoltaic array that complement the power output of a wind turbine generator in a stand-alone renewable energy system based on hydrogen production for long-term energy storage. The procedure for estimating hourly solar radiation, for a clear sunny day, from the daily average solar insolation is also given. The photovoltaic array power output and its effective contribution to the load as well as to the energy storage have been determined by using the solar radiation usability concept. The excess and deficit of electrical energy produced from the renewable energy sources, with respect to the load, govern the effective energy management of the system and dictate the operation of an electrolyser and a fuel cell generator. This performance analysis is necessary to determine the effective contribution from the photovoltaic array and the wind turbine generator and their contribution to the load as well as for energy storage.  相似文献   

3.
通过对唐山市区太阳能和风能资源状况调查分析,对全年不同方位角和倾角上的太阳能辐射量进行模拟计算,得出南偏东9.8°方向、倾角为39.7°的倾斜面上接收的太阳能辐射量最大,其值为1.62×106Wh/m2。研究中对3kW风力发电机和1kW光伏发电系统的发电量进行了计算,并以1辆纯电动轿车为负载进行了容量配比优化,设计了风力发电系统、风光互补系统及光伏系统三种不同的方案,经过对各方案的经济性、可靠性及稳定性分析,得出最佳的设计方案为风光互补发电系统,该系统风力发电装机容量为3kW,光伏发电装机容量为8.96kW。  相似文献   

4.
叙述了1种风光互补抽水智能控制系统设计方案,指出通过智能芯片对太阳能光电板和风力发电机发出来的能量进行合理的管理和分配,可有效地最大化地利用风能和太阳能,提出了1种新型抽水控制方法,试验表明,该方案取得了很好的效果。  相似文献   

5.
提出一种新的能量转化装置——内馈式感应发电机,叙述了其运行方式;并在内馈式感应发电机为主要动力装置的基础上建立可再生能源综合系统,给出了系统结构图,阐述各个系统元件之间的相互关系。  相似文献   

6.
This paper examines the economic viability of stand-alone, household-sized renewable energy technologies, namely wind generator and solar PV for application in remote and rural areas of Vietnam. Three reference technologies are chosen. These are two solar PV systems of 130 and 100 Wp for solar conditions in the North and the South, respectively, and one 150 W wind turbine. It is found for all regions that levelized costs of PV energy are lower than the cost of energy from gasoline gen-set, and are cost-competitive with grid extension, especially for areas with low load density and low number of households to be electrified. Regarding wind energy, the viability is dependent on the location due to the wide variation of wind resource to topography. However, in locations with proper resources, wind energy is even more cost-competitive than solar PV. Thus, the use of either wind generator or solar PV is economically feasible in rural villages and remote areas of Vietnam. Policy recommendations for promoting the market development of renewable energy technologies are discussed in the final section of the paper.  相似文献   

7.
针对当前风力发电系统输出功率随机波动的问题,以永磁同步风力发电机(PMSG)与直流侧储能系统(钒氧化还原电池)整合的风力发电系统为基础,进行数字仿真建模,采用MATLAB/Simulink软件对固定负载,变化风速工况;固定风速,负荷瞬变工况;风速和负荷同时变化工况;进行了仿真试验和分析。结果表明,对于采用储能技术的风电场并网功率随机波动的平抑控制,可以利用蓄电池的充放电特性,在风速变化以及负荷瞬变时进行功率平衡的调节。  相似文献   

8.
Depleting oil and gas reserves, combined with the growing concerns of global warming, have made it inevitable to seek alternative/renewable energy sources. The integration of renewables such as solar and wind energy is becoming increasingly attractive and is being used widely, for substitution of oil-produced energy, and eventually to minimize atmospheric degradation. The literature shows that commercial/residential buildings in Saudi Arabia consume an estimated 10–40% of the total electric energy generated. In the present investigation, hourly wind-speed and solar radiation measurements made at the solar radiation and meteorological monitoring station, Dhahran (26°32′ N, 50°13′ E), Saudi Arabia, have been analyzed to investigate the feasibility of using hybrid (wind+solar+diesel) energy conversion systems at Dhahran to meet the energy needs of twenty 2-bedroom houses. The monthly average wind speeds for Dhahran range from 4.1 to 6.4 m/s. The monthly average daily values of solar radiation for Dhahran range from 3.6 kWh/m2 to 7.96 kWh/m2. The performance of hybrid systems consisting of different rated power wind farms, photovoltaic (PV) areas, and storage capacities together with a diesel back-up are presented. The monthly average daily energy generated from the above hybrid system configuration has been presented. The deficit energy generated from the back-up diesel generator and the number of operational hours of the diesel system to meet a specific annual electrical energy demand of 702,358 kWh have also been presented.  相似文献   

9.
This paper presents an optimum sizing methodology to optimize the hybrid energy system (HES) configuration based on genetic algorithm. The proposed optimization model has been applied to evaluate the techno‐economic prospective of the HES to meet the load demand of a remote village in the northern part of Saudi Arabia. The optimum configuration is not achieved only by selecting the combination with the lowest cost but also by finding a suitable renewable energy fraction that satisfies load demand requirements with zero rejected loads. Moreover, the economic, technical and environmental characteristics of nine different HES configurations were investigated and weighed against their performance. The simulation results indicated that the optimum wind turbine (WT) selection is not affected only by the WT speed parameters or by the WT rated power but also by the desired renewable energy fraction. It was found that the rated speed of the WT has a significant effect on optimum WT selection, whereas the WT rated power has no consistent effect on optimal WT selection. Moreover, the results clearly indicated that the HES consisting of photovoltaics (PV), WT, battery bank (Batt) and diesel generator (DG) has superiority over all the nine systems studied here in terms of economical and environmental performance. The PV/Batt/DG hybrid system is only feasible when wind resource is very limited and solar energy density is high. On the other hand, the WT/Batt/DG hybrid system is only feasible at high wind speed and low solar energy density. It was also found that the inclusion of batteries reduced the required DG and hence reduced fuel consumption and operating and maintenance cost. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

10.
This paper provides a preliminary assessment of the performance and economic potential of a hybrid energy system (wind/diesel) power system which includes a variable speed diesel generator. Recent development in power electronics would be utilized to allow asynchronous operation of the diesel generator, while simultaneously delivering constant frequency electric power to the local electrical grid. In addition to the variable speed diesel, the system can include wind and/or solar electric sources. A hybrid energy system model recently developed at the University of Massachusetts is used to simulate this system configuration and other more conventional wind/diesel hybrid energy systems. Experimental data from a series of variable speed diesel generator tests were used to generate a series of fuel consumption curves used in the analytical model. In addition to performance (fuel savings) comparisons for fixed and variable speed systems, economic cost of energy calculations for the various system designs are presented. It is shown that the proposed system could offer both performance and economic advantages.  相似文献   

11.
This paper presents the results of an analytical performance and economic evaluation of a combined passive solar and wind powered residential heating and electrical energy system. Simulated in a New England wind and weather environment, the modeled system is based on the coupling of a vertical axis wind turbine with a super-insulated passive solar house. The analytical model is composed of four major sections: (1) residential heating and energy load; (2) wind turbine generator system; (3) energy system performance model; and (4) life-cycle costing economic analysis. Results for the heating, electrical supply and economic performance of the system are presented, varying such key parameters as residence window area, insulation, storage size, wind turbine size, and site average wind speed. These results show that when sited in adequate wind regimes (average wind speed greater than 5.4 m/sec (12 mph)) and coupled with super-insulated passive structures, wind turbines can provide significant fractions of the electrical and heating requirements in the New England environment.  相似文献   

12.
This paper proposes the use of a PV–wind–diesel generator hybrid system in order to determine the optimal configuration of renewable energy in Malaysia and to compare the production cost of solar and wind power with its annual yield relevant to different regions in Malaysia namely, Johor, Sarawak, Penang and Selangor. The configuration of optimal hybrid system is selected based on the best components and sizing with appropriate operating strategy to provide a cheap, efficient, reliable and cost-effective system. The various renewable energy sources and their applicability in terms of cost and performance are analyzed. Moreover, the annual yield and cost of energy production of solar and wind energy are evaluated. The Simulations were carried out using the HOMER program based on data obtained from the Malaysian Meteorological Centre. Results show that, for Malaysia, a PV–diesel generator hybrid system is the most suitable solution in terms of economic performance and pollution. However, the cost of production of solar and wind energy proved to be cheaper and more environmentally friendly than the energy produced from diesel generators.  相似文献   

13.
Present wind power is intermittent and cannot be used as the baseload energy source. Concept study of wind power utilizing direct thermal energy conversion and thermal energy storage named Wind powered Thermal Energy System (WTES) is conducted. The thermal energy is generated from the rotating energy directly at the top of the tower by the heat generator, which is a kind of simple and light electric brake. The rest of the system is the same as the tower type concentrated solar power (CSP). The cost estimation suggests that the energy cost of WTES is less than that of the conventional wind power, which must be supported by the backup thermal plants and grid enhancement. The light heat generator reduces some issues of wind power such as noise and vibration.  相似文献   

14.
太阳能烟囱发电新技术   总被引:13,自引:4,他引:13  
介绍了一种太阳能烟囱发电新技术。太阳光辐射透过太阳能集热棚,加热集热棚下面的地面,被加热的地面与集热棚内的空气进行热量交换,使其温度上升,被加热的空气上升并进入与集热棚中部相连的烟囱,在烟囱内上升气流推动涡轮发电机旋转、发电。整个太阳能烟囱发电技术的能量转化以及效率可以从三个部分来分析:通过集热棚太阳能转化为空气热能,通过烟囱将热能转化为动能,通过涡轮发电机将动能转化为电能。另外,总结了太阳能烟囱发电技术的优缺点,指出它是一种适合于我国西部地区的一种能源开发新途径。  相似文献   

15.
In this work, a combined system which is produced electrical energy from both solar radiation via solar cells and wind energy by using wind turbine was studied. For wind energy, measurements of wind velocities at 12 m height were taken. Then, these values were calculated for 42 m by using Hellmann equation. After that, wind energy converted to the electrical energy. However, value of solar radiation from solar cells was taken at the optimum slope angle of collector which provided higher energy production for each 1 h during this application. Thus, obtained data from each system were used together for finding total energy. For this study, measurements, which would be used in calculation of wind energy and solar energy were taken for four years between 1995 and 1998 in Izmir. As a result, energy of the combined system could support each other when one of them produces energy insufficiently.  相似文献   

16.
The optimal design of the renewable energy system can significantly improve the economical and technical performance of power supply. In this paper, the technical-economic optimization study of a stand-alone hybrid PV/wind system (HPWS) in Corsica Island is presented.

Therefore, the primary objective of this study is to estimate the appropriate dimensions of a stand-alone HPWS that guarantee the energy autonomy of a typical remote consumer with the lowest levelised cost of energy (LCE). A secondary aim is to compare the performance and the optimal sizing of two system configurations. Finally, to study the impact of the renewable energy potential quality on the system size, the optimum dimensions of system are defined for five sites in Corsica Island. In this context, a complete sizing model is developed, able to predict the optimum system configuration on the basis of LCE. Accordingly, an integrated energy balance analysis is carried out for the whole time period investigated.

The simulation results indicate that the hybrid system is the best option for all the sites considered in this study, yielding lower LCE. Thus, it provides higher system performance than PV or wind systems alone. The choice of the system configuration type affects the state of charge variation profile, especially at low wind potential sites, while the system size and the LCE are significantly influenced. It is shown that the LCE depends largely on the renewable energy potential quality. At high wind potential site, more than 40% of the total production energy is provided by the wind generator, while at low wind potential sites, less than 20% of total production energy is generated by the wind generator.  相似文献   


17.
The wind energy potential at four different sites in Ethiopia – Addis Ababa (09:02N, 38:42E), Mekele (13:33N, 39:30E), Nazret (08:32N, 39:22E), and Debrezeit (8:44N, 39:02E) – has been investigated by compiling data from different sources and analyzing it using a software tool. The results relating to wind energy potential are given in terms of the monthly average wind speed, wind speed probability density function (PDF), wind speed cumulative density function (CDF), and wind speed duration curve (DC) for all four selected sites. In brief, for measurements taken at a height of 10 m, the results show that for three of the four locations the wind energy potential is reasonable, with average wind speeds of approximately 4 m/s. For the fourth site, the mean wind speed is less than 3 m/s. This study is the first stage in a longer project and will be followed by an analysis of solar energy potential and finally the design of a hybrid standalone electric energy supply system that includes a wind turbine, PV, diesel generator and battery.  相似文献   

18.
As the development of China's economy, environmental problems in China become more and more serious. Solar energy and wind energy are considered as ones of the best choices to solve the environmental problems in China and the hybrid wind/solar distributed generation (DG) system has received increasing attention recently. However, the instability and intermittency of the wind and solar energy throw a huge challenge on designing of the hybrid system. In order to ensure the continuous and stable power supply, optimal unit sizing of the hybrid wind/solar DG system should be taken into consideration in the design of the hybrid system. This paper establishes a multi-objective optimization framework based on cost, electricity efficiency and energy supply reliability models of the hybrid DG system, which is composed of wind, solar and fuel cell generation systems. Detailed models of each unit for the hybrid wind/solar/fuel cell system were established. Advanced ε-constraints method based on Hammersley Sequence Sampling was employed in the multi-objective optimization of the hybrid DG system. The approximate Pareto surface of the multi-objective optimization problems with a range of possible design solutions and a logical procedure for searching the global optimum solution for decision makers were presented. In this way, this work provided an efficient method for decision makers in the design of the hybrid wind/solar/fuel cell system.  相似文献   

19.
风光互补发电系统的优化设计(I) CAD设计方法   总被引:2,自引:0,他引:2  
给出了一整套利用CAD进行风光互补发电系统优化设计的方法。为了精确确定系统每小时的运行状态,采用了更精确地表征组件特性及评估实际获得的风光资源的数学模型。为了寻找出以最小设备投资成本满足用户用电要求的系统配置,首先在风力发电机容量固定不变的前提下,计算了与该容量风力发电机匹配的不同容量的PV方阵和蓄电池所组成的风/光/蓄组合的全年功率供给亏欠率LPSP,根据总的设备投资成本最小化的原则筛选出一组与该容量风力发电机对应的满足用户给定系统供电可靠性即LPSP值的风/光/蓄组合;然后通过改变风力发电机的容量,优选出多个与不同容量风力发电机对应的既能满足用户用电要求同时总的设备购置成本又是最低的风/光/蓄组合,比较它们的成本最终唯一确定出以最小投资成本满足用户用电要求的优化的系统配置。  相似文献   

20.
A demonstrative study for the wind and solar hybrid power system   总被引:1,自引:0,他引:1  
In March 1995, a small scale wind and solar hybrid power system was installed at Ashikaga Institute of Technology. Until now, the authors have acquired the data of the output of the hybrid power plant along with wind speed, wind direction, and the solar radiation, in order to demonstrate a complementary relationship between solar energy and wind energy.After nine months operation of the system, the authors confirmed that there exists a complementary relationship between solar energy and wind energy. We also found, however, that the power output by wind does not have much prospect compared to that by solar cell especially in summer season in Ashikaga area.  相似文献   