1.
Integration of the heat pipe with an ejector will result in a compact and high performance system. The concept of the heat pipe/ejector refrigeration cycle is discussed, in this paper. The needed driving capillary forces are firmly established. The basic characteristics of the system, such as entrainment ratio, coefficient of performance, exergy efficiency and thermal efficiency of the system are evaluated. Also, the zero-dimensional constant pressure mixing theory is applied to ejector. In this study, water is used as the working fluid. Whenever the mixed flow is supersonic, a normal shockwave is assumed to occur upstream of diffuser inlet. The simulation results indicate that, the coefficient of performance can reach about 0.30 at Te = 10 °C, Tc = 30 °C and Tg = 100 °C. Also, the second law efficiency of the heat pipe/ejector refrigeration cycle increases with increasing evaporator temperature and decreasing condenser temperature. It is seen that, the maximum heat pipe cooling capacity obtains for large heat pipe diameters, near the small heat pipe lengths. It has proven that, this refrigeration system can be widely used in many areas, especially in renewable energy utilization such as solar energy.  相似文献   

2.
S.M. Xu  X.D. Huang 《Solar Energy》2011,85(9):1794-1804
This paper presented a new solar powered absorption refrigeration (SPAR) system with advanced energy storage technology. The advanced energy storage technology referred to the Variable Mass Energy Transformation and Storage (VMETS) technology. The VMETS technology helped to balance the inconsistency between the solar radiation and the air conditioning (AC) load. The aqueous lithium bromide (H2O-LiBr) was used as the working fluid in the system. The energy collected from the solar radiation was first transformed into the chemical potential of the working fluid and stored in the system. Then the chemical potential was transformed into thermal energy by absorption refrigeration when AC was demanded. In the paper, the working principle and the flow of the SPAR system were explained and the dynamic models for numerical simulation were developed. The numerical simulation results can be used to investigate the behavior of the system, including the temperature and concentration of the working fluid, the mass and energy in the storage tanks, the heat loads of heat exchanger devices and so on. An example was given in the paper. In the example, the system was used in a subtropical city like Shanghai in China and its operating conditions were set as a typical summer day: the outdoor temperature varied between 29.5 °C and 38 °C, the maximum AC load was 15.1 kW and the total AC capacity was 166.1 kW h (598.0 MJ). The simulation results indicated that the coefficient of performance (COP) of the system was 0.7525 or 0.7555 when the condenser was cooled by cooling air or by cooling water respectively and the storage density (SD) was about 368.5 MJ/m3. As a result, the required solar collection area was 66 m2 (cooling air) or 62 m2 (cooling water) respectively. The study paves the road for system design and operation control in the future.  相似文献   

3.
A domestic-scale prototype experimental solar cooling system has been developed based on a LiBr/H2O absorption system and tested during the 2007 summer and autumn months in Cardiff University, UK. The system consisted of a 12 m2 vacuum tube solar collector, a 4.5 kW LiBr/H2O absorption chiller, a 1000 l cold storage tank and a 6 kW fan coil. The system performance, as well as the performances of the individual components in the system, were evaluated based on the physical measurements of the daily solar radiation, ambient temperature, inlet and outlet fluid temperatures, mass flow rates and electrical consumption by component. The average coefficient of thermal performance (COP) of the system was 0.58, based on the thermal cooling power output per unit of available thermal solar energy from the 12 m2 Thermomax DF100 vacuum tube collector on a hot sunny day with average peak insolation of 800 W/m2 (between 11 and 13.30 h) and ambient temperature of 24 °C. The system produced an electrical COP of 3.6. Experimental results prove the feasibility of the new concept of cold store at this scale, with chilled water temperatures as low as 7.4 °C, demonstrating its potential use in cooling domestic scale buildings.  相似文献   

4.
Consolidated composite material made from expanded graphite (EG) powder impregnated with LiCl salt is proposed for use in solar powered adsorption ice makers. Laboratory experiments were done to test the adsorption and desorption performance of the sorbent under different temperature conditions suitable for solar energy utilization. More than 75% of the reaction between LiCl and ammonia was completed after 30 min of synthesis at evaporation temperatures of −10 and −5 °C and adsorption temperature between 25 and 35 °C. Under the same period, it was possible to obtain 80% conversion in the desorption phase, when the generation temperatures ranged between 75 and 80 °C, and the condensation temperature varied from 25 to 35 °C. The highest average specific cooling power during the synthesis phase was 117 W per kg of the block. The calculated theoretical coefficient of performance (COP) under different cycle conditions was nearly constant at 0.47. Moreover, the new composite sorbent showed higher Specific Cooling Capacity (SCC), compared to activated carbon (AC)/methanol pair. Experiments done with blocks with different proportion of EG, showed that the proportion of EG influence the cooling capacity per unit mass of salt and had almost no influence on the cooling capacity per unit mass of the block. Moreover, the reaction enthalpy (ΔH) and entropy (ΔS) were calculated from experimental data obtained experimentally, and confirmed previous reported values.  相似文献   

5.
A solar deep-freezing process has been designed. It aims at cooling down a cold box to about −20 °C, using simple flat plate solar collectors operating at 70 °C. This original process involves two cascaded thermochemical systems based on the BaCl2/ammonia reaction. Its working mode is discontinuous as it alternates between a regeneration mode during daytime and a cold production mode during nighttime. A global dynamic model involving the various system components allows the simulation of the process; it predicts the evolution of the components temperatures and the rates of chemical reactions of the system. It also allows the dimensioning of the system components to maintain a 500 l cold box at −20 °C during the 6 sunniest months of the year under typical Mediterranean weather conditions and provide over 80% of the total yearly cooling needs of this box. This requires a solar collector area of 5.8 m2 and 39 kg of reactive salt. The predicted coefficient of performance (COP) is about 0.1 over the year, and the net solar COP, taking into account the collector efficiencies, is 0.05.  相似文献   

6.
A. El Fadar  A. Mimet 《Solar Energy》2009,83(6):850-861
This article suggests a numerical study of a continuous adsorption refrigeration system consisting of two adsorbent beds and powered by parabolic trough solar collector (PTC). Activated carbon as adsorbent and ammonia as refrigerant are selected. A predictive model accounting for heat balance in the solar collector components and instantaneous heat and mass transfer in adsorbent bed is presented. The validity of the theoretical model has been tested by comparison with experimental data of the temperature evolution within the adsorber during isosteric heating phase. A good agreement is obtained. The system performance is assessed in terms of specific cooling power (SCP), refrigeration cycle COP (COPcycle) and solar coefficient of performance (COPs), which were evaluated by a cycle simulation computer program. The temperature, pressure and adsorbed mass profiles in the two adsorbers have been shown. The influences of some important operating and design parameters on the system performance have been analyzed.The study has put in evidence the ability of such a system to achieve a promising performance and to overcome the intermittence of the adsorption refrigeration systems driven by solar energy. Under the climatic conditions of daily solar radiation being about 14 MJ per 0.8 m2 (17.5 MJ/m2) and operating conditions of evaporating temperature, Tev = 0 °C, condensing temperature, Tcon = 30 °C and heat source temperature of 100 °C, the results indicate that the system could achieve a SCP of the order of 104 W/kg, a refrigeration cycle COP of 0.43, and it could produce a daily useful cooling of 2515 kJ per 0.8 m2 of collector area, while its gross solar COP could reach 0.18.  相似文献   

7.
Temperature control of solar cells at high concentrations is a key issue. Short-term efficiency drop and long-term degradation should be avoided by effective cooling methods. Liquid immersion cooling eliminates the contact thermal resistance of back cooling and should improve cell performance. A 250X dish concentrator with two-axis tracking was utilized to evaluate a new CPV system using de-ionized water for immersion cooling. Time-dependent temperature distributions of the PV module of high power back point-contact cells were measured, as well as the I-V curves. The cooling capacities of the liquid immersion approach are very favorable. The module temperature can be cooled to 45 °C at a 940 W/m2 direct normal irradiance, 17 °C ambient temperature and 30 °C water inlet temperature. The temperature distribution of the module is quite uniform, but the electrical performance of the cell module degrades after a fairly long time immersion in the de-ionized water.  相似文献   

8.
A novel solar intermittent refrigeration system for ice production developed in the Centro de Investigación en Energía of the Universidad Nacional Autónoma de México is presented. The system operates with the ammonia/lithium nitrate mixture. The system developed has a nominal capacity of 8 kg of ice/day. It consists of a cylindrical parabolic collector acting as generator-absorber. Evaporator temperatures as low as −11 °C were obtained for several hours with solar coefficients of performance up to 0.08. It was found that the coefficient of performance increases with the increment of solar radiation and the solution concentration. A dependency of the coefficient of performance was not founded against the cooling water temperature. Also it was found that the maximum operating pressure increases meanwhile the generation temperature decreases with an increase of the solution concentration.  相似文献   

9.
In this study, a thermally driven adsorption cooling unit using natural zeolite–water as the adsorbent–refrigerant pair has been built and its performance investigated experimentally at various evaporator temperatures. The primary components of the cooling unit are a shell and tube adsorbent bed, an evaporator, a condenser, heating and cooling baths, measurement instruments and supplementary system components. The adsorbent bed is considered to enhance the bed’s heat and mass transfer characteristics; the bed consists of an inner vacuum tube filled with zeolite (zeolite tube) inserted into a larger tubular shell. Under the experimental conditions of 45 °C adsorption, 150 °C desorption, 30 °C condenser and 22.5 °C, 15 °C and 10 °C evaporator temperatures, the COP of the adsorption cooling unit is approximately 0.25 and the maximum average volumetric cooling power density (SCPv) and mass specific cooling power density per kg adsorbent (SCP) of the cooling unit are 5.2 kW/m3 and 7 W/kg, respectively.  相似文献   

10.
A novel cooling method for the solar cells under concentrated solar flux is proposed where the surplus heat is removed from both the front and back surfaces of the module by directly immersing the cells in a dielectric liquid. The direct-contact heat transfer and comparatively larger heat dissipation surface area can achieve a fairly low cell temperature which results in higher sunlight conversion efficiencies. Heat dissipation performance of the modules of both simulation sheets and solar cells were studied under the conditions of an irradiance of 50 and 70 kW/m2. In these studies a long-arc xenon lamp was used as the illumination source and dimethyl-silicon oil was used as the dielectric fluid. Experimental results show that in turbulent flow, the temperature distribution of the module along the flow direction is quite uniform, resulting in a rise of about 3 °C. The cell temperature can be cooled to about 30 °C and the corresponding heat transfer coefficient is around 1000 W/(m2 °C). The liquid inlet temperature does not significantly change the distribution of the module temperature, but it has a linear relationship with the average module temperature. After liquid immersion, the open-circuit voltages of the modules have small changes but large drops are in the short circuit currents. The electrical performance of the modules immersed in the liquid fits reasonably well with the relationships with the operating temperatures and thermal loads, but clearly with some degradation. The main reason for these is because the usage of common silicon cells under concentrations.  相似文献   

11.
Solar energy can be used for substitution of the depleting fossil fuels in thermal applications and electricity generation through thermal route. For medium and high temperature applications, solar concentrators are required. Proper sizing and selection of concentrator for any thermal application calls for characterization of the concentrator at the required operating temperature. There are few procedures reported in literature for testing and evaluating solar concentrator performance which are based on sensible heating of the working fluid. One of the limitations of these procedures is requirement of precise operating conditions during testing. A test procedure for characterization of point-focus steam generating solar concentrators based on latent heating at different operating temperatures is proposed. The proposed procedure uses the phase change characteristic of water at constant temperature to measure the thermal performance. This procedure can be used to estimate thermal efficiency of solar concentrator at different operating temperatures above 100 °C. This procedure was used to estimate the efficiency of a point-focus solar concentrator having 25 m2 aperture area at 161 °C (equivalent to 5.4 bar (g)). The efficiency was estimated as 47 ± 3.5%. The test procedure can be used for field evaluation of existing systems also with minimum amount of instrumentation and controls.  相似文献   

12.
L.J. He  L.M. Tang 《Solar Energy》2009,83(11):2029-2038
A theoretical analysis of the coefficient of performance was undertaken to examine the efficiency characteristics of R22 + DMF, R134a + DMF, R32 + DMF as working fluids, respectively, for a single-stage and intermittent absorption refrigerator which allows the use of heat pipe evacuated tubular collectors. The modeling and simulation of the performance considers both solar collector system and the absorption cooling system. The typical meteorological year file containing the weather parameters for Hangzhou is used to simulate the system. The results show that the system is in phase with the weather. In order to increase the reliability of the system, a hot water storage tank is essential. The optimum ratio of storage tank per solar collector area for Hangzhou’s climate for a 1.0 kW system is 0.035-0.043L. Considering the relative low pressure and the high coefficient of performance, R134a + DMF mixture presents interesting properties for its application in solar absorption cycles at moderate condensing and absorbing temperatures when the evaporating temperatures in the range from 278 K to 288 K which are highly useful for food preservation and for air-conditioning in rural areas.  相似文献   

13.
Non-concentrated evacuated tube heat pipe solar collectors have been reported to show higher fluid temperatures with improved thermal performance in the low to medium temperature range (?60 °C) due to low heat losses but suffer higher heat losses at the medium to higher temperature range (?80 °C) which reduces their efficiency compared to concentrated evacuated tube heat pipe solar collectors. To operate as stand-alone systems capable of attaining temperatures in the range of 70-120 °C, an innovative concentrator augmented solar collector can be an attractive option. The performance of a combined low-concentrator augmented solar collector in an array of evacuated tube heat pipe solar collectors defined as concentrator augmented evacuated tube heat pipe array (CAETHPA) and an array of evacuated tube heat pipe collectors (ETHPC) were tested and compared and results presented in this paper. The analysis of the experimental data allows concluding that the use of a CAETHPA is a more efficient alternative for integrating renewable energy into buildings with higher fluid temperature response, energy collection and lower heat loss coefficient compared to the use of evacuated tube heat pipe collector array (ETHPA).  相似文献   

14.
The objectives of the present work are of two-folds. First, it evaluates the transient temperature performance of the H2O–NH3–H2 absorption cooling machine system’s components under two types of energy sources, i.e. the conventional electric energy from grid (electric) and fuel energy from liquid petroleum gas (LPG). Results obtained have shown that performance of various components under different type of energy sources is almost coherent. For the evaporator, the system with electric supply has shorter starting time, around 6 min earlier than the system run with LPG. Meanwhile, the system powered by LPG produced a lower cooling temperature around −9 °C, compared to the system run with electric which produced temperature at around −7 °C. Economical study had been carried out subsequently, for three different energy sources, i.e. electric, LPG and solar energy (photovoltaic). From the techno-economical analyzes, it was found that the conventional electric from grid is still the best form of energy source for short-term application, as far as the present location and conditions are concerned. LPG is the next attractive energy source, especially at locations with constant LPG supply; the photovoltaic energy from solar is attractive for long term consideration since it has zero fuel cost and environmentally-friendly, but with the highest initial cost.  相似文献   

15.
In this paper, a new consolidated composite sorbent made from barium chloride and expanded graphite is presented for solar-powered thermochemical sorption cooling systems. A larger sorption capacity and volume cooling density can be obtained with chemisorption systems when compared with those based on physicosorption. The heat transfer and sorption characteristics of the composite sorbent were investigated. Experimental results showed that the chemical composite sorbent can effectively utilize solar energy or low-grade waste heat sources with temperature ranging from 75 to 90 °C, and it could incorporate 0.61 kg of ammonia per kg of the reactive salt. The temperature evolution in the reactor was strongly influenced by the physicochemical reaction, whereas the transient heat transfer properties in the reactive composite material were different during the decomposition and the synthesis phases owing to the variation of the ammonia content and solid configuration inside the metallic salt complex. The rate of conversion in the reactor was very sensitive to the working temperatures and pressures, and the COP (coefficient of performance) obtained with the consolidated composite sorbent varied between 0.50 and 0.53 when the evaporation temperature ranged from 0 to 15 °C at a generation temperature of 80 °C.  相似文献   

16.
A parabolic solar cooker with automatic two axes sun tracking system was designed, constructed, operated and tested to overcome the need for frequent tracking and standing in the sun, facing all concentrating solar cookers with manual tracking, and a programmable logic controller was used to control the motion of the solar cooker. The results of the continuous test – performed for three days from 8:30 h to 16:30 h in the year 2008 – showed that the water temperature inside the cooker’s tube reached 90 °C in typical summer days, when the maximum registered ambient temperature was 36 °C. It was also noticed that the water temperature increases when the ambient temperature gets higher or when the solar intensity is abundant. This is in favor of utilizing this cooker in many developing countries, which are characterized by high solar insulations and high temperatures. Besides cooking, the proposed cooker could be utilized for warming food, drinks as well as to pasteurize water or milk.  相似文献   

17.
This paper analyses a steam power – two-stage binary cycle plant (SPP–2BCP), in which low temperature waste heat from a conventional steam power plant can be efficiently utilized to generate electricity by installing a bottoming binary cycle. The result from a previous calculation on the installation of binary cycle technology on a Steam Power Plant (SPP) with n-Pentane working fluid indicates an increase in plant efficiency of about 9%. The purpose of this study is to analyze the sensitivity of performance of the binary cycle system against variations in the SPP operational load and the condenser’s cooling water temperature. The calculation is conducted on SPP load variations of 25%, 50%, 75% and 100%, inlet turbine pressure variations of 5 bar–30 bar, and inlet turbine temperature variations of 125 °C up to 235 °C. Each of these is also analyzed with ambient cooling water temperatures of 30 °C–37 °C. The results of the analysis indicate that the performance of this binary cycle SPP degrades slightly with SPP load, turbine inlet temperature, and turbine inlet pressure variations and with cooling water variations.  相似文献   

18.
This paper studies the feasibility of using a solar-powered liquid desiccant system to meet both building cooling and fresh water needs in Beirut humid climate using parabolic solar concentrators as a heat source for regenerating the liquid desiccant. The water condensate is captured from the air leaving the regenerator. An integrated model of solar-powered calcium chloride liquid desiccant system for air dehumidification/humidification is developed. The LDS model predicted the amount of condensate obtained from the humid air leaving the regenerator bed when directed through a coil submerged in cold sea water. An optimization problem is formulated for selection and operation of a LDS to meet fresh water requirement and air conditioning load at minimal energy cost for a typical residential space in the Lebanon coastal climate with conditioned area of 80 m2 with the objective of producing 15 l of fresh drinking water a day and meet air conditioning need of residence at minimum energy cost. The optimal regeneration temperature increases with decreased heat sink temperature with values of 50.5 °C and 52 °C corresponding to sink temperatures of 19 °C and 16 °C.  相似文献   

19.
An aquifer coupled cavity flow heat exchanger system (ACCFHES) was designed using underground aquifer water for the heating as well as cooling of a composite climatic greenhouse. The performance of ACCFHES was experimentally evaluated for a full winter and a summer season. The ACCFHES makes use of constant temperature aquifer water (24 °C) available at an agricultural field through an irrigation tube well for heating in winter nights and cooling in summer days. The results showed that the average greenhouse room air temperature was maintained 7–9 °C above the outside air during extreme winter nights and 6–7 °C below the outside air in extreme summer days, and temperature fluctuations inside the greenhouse also decreased daily. The average relative humidity (RH) inside the greenhouse also decreased by 10–12% in the winter and increased by more than double in the extreme summer conditions as compared to the outside conditions. A comparison of economic feasibility of the ACCFHES coupled greenhouse was also conducted with conventional greenhouse and open field condition based on the yield of Capsicum annum. The ACCFHES was also compared economically with other existing heating/cooling technologies such as earth-to-air heat exchanger system (EAHES), ground air collector, evaporative cooling using foggers and fan & pad system in terms of net present worth (NPW) and pay back period. It was observed that the NPW of the ACCFHES coupled greenhouse was much higher as compared to the conventional greenhouse and open field condition. The payback period of the ACCFHES coupled greenhouse was the lowest among all other existing heating/cooling systems.  相似文献   

20.
In this paper, 3-D numerical analysis of the porous disc line receiver for solar parabolic trough collector is presented. The influence of thermic fluid properties, receiver design and solar radiation concentration on overall heat collection is investigated. The analysis is carried out based on renormalization-group (RNG) kε turbulent model by using Therminol-VP1 as working fluid. The thermal analysis of the receiver is carried out for various geometrical parameters such as angle (θ), orientation, height of the disc (H) and distance between the discs (w) and for different heat flux conditions. The receiver showed better heat transfer characteristics; the top porous disc configuration having w = di, H = 0.5di and θ = 30°. The heat transfer characteristic enhances about 64.3% in terms of Nusselt number with a pressure drop of 457 Pa against the tubular receiver. The use of porous medium in tubular solar receiver enhances the system performance significantly.  相似文献   