首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 655 毫秒
1.
In this study, the hydrogen production potential and costs by using wind/electrolysis system in P?narba??-Kayseri were considered. In order to evaluate costs and quantities of produced hydrogen, for three different hub heights (50 m, 80 m and 100 m) and two different electrolyzer cases, such as one electrolyzer with rated power of 120 kW (Case-I) and three electrolyzers with rated power of 40 kW (Case-II) were investigated. Levelised cost of electricity method was used in order to determine the cost analysis of wind energy and hydrogen production. The results of calculations brought out that the electricity costs of the wind turbines and hydrogen production costs of the electrolyzers are decreased with the increase of turbine hub height. The maximum hydrogen production quantity was obtained 14192 kgH2/year and minimum hydrogen cost was obtained 8.5 $/kgH2 at 100 m hub height in the Case-II.  相似文献   

2.
One of the most appropriate ways for energy storage is producing hydrogen from renewable resources. Wind energy is recognized as one of the widely used renewable energy resources. This paper investigates the use of wind energy for producing hydrogen in Iran. To achieve this, the country is divided into five major regions: center, north, south, east and west. The performance of three large-scale commercial wind turbines, ranging from 1500 kW to 3000 kW at hub height of 80 m and four large-scale wind turbine ranging from 2000 kW to 4500 kW at hub height of 120 m are evaluated for producing hydrogen in 150 wind stations in Iran. All wind data were recorded based on 10-min time intervals for more than one year at different wind mast heights. For estimating Weibull parameters, the Standard Deviation Method (SDM), Empirical Method of Lysen (EML) and Power Density Method (PDM) are used. An extrapolation method is used to determine the shape and the scale parameters of the Weibull distribution at the high attitudes of 80 m and 120 m. Then, power law and surface roughness exponents, capacity factor, annual energy production and annual hydrogen production for the wind sites are determined. The results indicate that rated power is not the only determinative parameter and the highest hydrogen production is from the GW-109/2500 wind turbine at the hub height of 80 m and from E112/4500 at the hub height of 120 m. For better assessment, the amount of hydrogen production is depicted in Geographic Information Science (GIS) maps using power production of the seven wind turbine models. Next by analyzing these GIS maps, it is found that there are significant potentials in north, north-west, east and south of Iran for producing hydrogen from wind energy.  相似文献   

3.
Hydrogen is one of the energy carriers that can be produced using different techniques. Combining multiple energy sources can enhance hydrogen production and meet other electrical demands. The hybrid arrangement allows the produced hydrogen to be stored and used when the electrical energy sources are not adequate. In this study, utilizing the meteorological data was investigated using HOMER (Hybrid Optimization of Multiple Energy Resources) software for the optimal solution. The results demonstrated that the “best-optimized system has 270 kW of photovoltaic (PV), 1 unit of 300 kW of wind turbine (WT), 500 kW of electrolyzer, 100 kg/L of the hydrogen tank, 70 units of 1 kWh lithium-ion battery, and 472 kW of the converter. The selected hybrid energy system has the lowest Levelized cost of energy (LCOE), Levelized cost of hydrogen (LCOH), and net present cost (NPC) of $/kg 0.6208, $/kg 9.34, and $ 484,360.00 respectively which judged the system to be the best choice for the proposed hydrogen project in AI-Kharj. This investigation will help stakeholders and policymakers optimize hybrid energy systems that economically meet the hydrogen production and refueling station demands of the AI-Kharj community.  相似文献   

4.
An autonomous wind/hydrogen energy demonstration system located at the island of Utsira in Norway was officially launched by Norsk Hydro (now StatoilHydro) and Enercon in July 2004. The main components in the system installed are a wind turbine (600 kW), water electrolyzer (10 Nm3/h), hydrogen gas storage (2400 Nm3, 200 bar), hydrogen engine (55 kW), and a PEM fuel cell (10 kW). The system gives 2–3 days of full energy autonomy for 10 households on the island, and is the first of its kind in the world. A significant amount of operational experience and data has been collected over the past 4 years. The main objective with this study was to evaluate the operation of the Utsira plant using a set of updated hydrogen energy system modeling tools (HYDROGEMS). Operational data (10-min data) was used to calibrate the model parameters and fine-tune the set-up of a system simulation. The hourly operation of the plant was simulated for a representative month (March 2007), using only measured wind speed (m/s) and average power demand (kW) as the input variables, and the results compared well to measured data. The operation for a specific year (2005) was also simulated, and the performance of several alternative system designs was evaluated. A thorough discussion on issues related to the design and operation of wind/hydrogen energy systems is also provided, including specific recommendations for improvements to the Utsira plant. This paper shows how important it is to improve the hydrogen system efficiency in order to achieve a fully (100%) autonomous wind/hydrogen power system.  相似文献   

5.
Egypt is one of the Red Sea and Mediterranean countries having windy enough areas, in particular along the coasts. The coastal location Ras Ghareb on the Red Sea has been investigated in order to know the wind power density available for electricity generation. To account for the wind potential variations with height, a new simple estimating procedure was introduced. This study has explicitly demonstrated the presence of high wind power density nearly 900 kW/m2 per year at 100 m of altitude for this region. Indeed, the seasonal wind powers available are comparable to and sometimes higher than the power density in many European cities for wind electricity applications like Vindeby (Denmark) and also America.New technical analysis for wind turbine characteristics have been made using three types of commercial wind turbines possessing the same rotor diameter and rated power to choice the best wind machine suitable for Ras Ghareb station. As per the decreasing the cut-in wind speed for the wind turbine used, the availability factor increases for a given generator. That it could produce more energy output throughout the year for the location.The aim of this research, was to predict the electrical energy production with the cost analysis of a wind farm 150 MW total power installed at Ras Ghareb area using 100 wind turbines model (Repower MD 77) with 1.5 MW rated power. Additionally, this paper developed the methodology for estimating the price of each kWh electricity from the wind farms. Results show that this wind park will produce maximum energy of 716 GWh/year. The expected specific cost equal to 1.5 € cent/kWh is still less than and very competitive price with that produced from the wind farms in Great Britain and Germany and at the international markets of wind power. The important result derived from this study encourages several wind parks with hundreds of megawatts can be constructed at Ras Ghareb region.  相似文献   

6.
Hydrogen as an energy carrier can play a significant role in reducing environmental emissions if it is produced from renewable energy resources. This research aims to assess hydrogen production from wind energy considering environmental, economic, and technical aspect for the East Azerbaijan province of Iran. The economic assessment is performed by calculation of payback period, levelized cost of hydrogen, and levelized cost of electricity. Since uncertainty in the power output of wind turbines may affect the payback period, all calculations are performed for four different turbine degradation rates. While it is common in the literature to choose the wind turbine based on a single criterion, this study implements Multi-Criteria Decision-Making (MCDM) techniques for this purpose. The results of Step-wise Weight Assessment Ratio Analysis illustrates that economic issue is the most important criterion for this research. The results of Weighted Aggregated Sum Product Assessment shows that Vestas V52 is the most suitable wind turbine for Ahar and Sarab cities, while Eovent EVA120 H-Darrieus is a better choice for other stations. The most suitable location for wind power generation is found to be Ahar, where it is estimated to annually generate 2914.8 kWh of electricity at the price of 0.045 $/kWh, and 47.2 tons of hydrogen at the price of 1.38 $/kg, which result in 583 tons of CO2 emission reduction.  相似文献   

7.
Most inhabitants of rural communities in Africa lack access to clean and reliable electricity. This has deprived the rural dwellers access to modern healthcare delivery. In this paper, an off-grid renewable energy system consisting of solar PV and wind turbine with hydrogen storage scheme has been explored to meet the electrical energy demands of a health clinic. The health clinic proposed is a group II with 10 beds located in a typical village in South Africa. First, the wind and solar energy resources of the village were analysed. Thereafter, the microgrid architecture that would meet the energy demand of the clinic (18.67 kWh/day) was determined. Some of the key results reveal that the average annual wind speed at 60 m anemometer height and solar irradiation of the village are 7.9 m/s and 4.779 kWh/m2/day, respectively. The required architecture for the clinic composes of 40 kW solar PV system, 3 numbers of 10 kW wind turbines, 8.6 kW fuel cell, 25 kW electrolyser and 40 kg hydrogen tank capacity. The capital cost of the microgrid was found to be $177,600 with a net present cost of $206,323. The levelised cost of energy of the system was determined to be 2.34 $/kWh. The project has a breakeven grid extension distance of 8.81 km. Since this distance is less than the nearest grid extension distance of 21.35 km, it is established that the proposed renewable energy microgrid with a hydrogen storage system is a viable option for the rural community health clinic.  相似文献   

8.
R. Damiani  A. Ning  B. Maples  A. Smith  K. Dykes 《风能》2017,20(4):731-747
Challenging bathymetry and soil conditions of future US offshore wind power plants might promote the use of multimember, fixed‐bottom structures (or ‘jackets’) in place of monopiles. Support structures affect costs associated with the balance of system and operation and maintenance. Understanding the link between these costs and the main environmental design drivers is crucial in the quest for a lower levelized cost of energy, and it is the main rationale for this work. Actual cost and engineering data are still scarce; hence, we evaluated a simplified engineering approach to tie key site and turbine parameters (e.g. water depth, wave height, tower‐head mass, hub height and generator rating) to the overall support weight. A jacket‐and‐tower sizing tool, part of the National Renewable Energy Laboratory's system engineering software suite, was utilized to achieve mass‐optimized support structures for 81 different configurations. This tool set provides preliminary sizing of all jacket components. Results showed reasonable agreement with the available industry data, and that the jacket mass is mainly driven by water depth, but hub height and tower‐head mass become more influential at greater turbine ratings. A larger sensitivity of the structural mass to wave height and target eigenfrequency was observed for the deepest water conditions (>40 m). Thus, techno‐economic analyses using this model should be based on accurate estimates of actual metocean conditions and turbine parameters especially for deep waters. The relationships derived from this study will inform National Renewable Energy Laboratory's offshore balance of system cost model, and they will be used to evaluate the impact of changes in technology on offshore wind lower levelized cost of energy. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

9.
This paper statistically examine wind characteristics from seven meteorological stations within the North-West (NW) geo-political region of Nigeria using 36-year (1971–2007) wind speed data measured at 10 m height subjected to 2-parameter Weibull analysis. It is observed that the monthly mean wind speed in this region ranges from 2.64 m/s to 9.83 m/s. The minimum monthly mean wind speed was recorded in Yelwa in the month of November while the maximum value is observed in Katsina in the month of June. The annual wind speeds range from 3.61 m/s in Yelwa to 7.77 m/s in Kano. It is further shown that Sokoto, Katsina and Kano are suitable locations for wind turbine installations with annual mean wind speeds of 7.61, 7.45 and 7.77 m/s, respectively. The results also suggest that Gusau and Zaria should be applicable for wind energy development using taller wind turbine towers due to their respective annual mean speeds and mean power density while Kaduna is considered as marginal. In addition, higher wind speeds were recorded in the morning hours than afternoon periods for this region. A technical electricity generation assessment using four commercial wind turbines were carried out. The results indicate that, while the highest annual power is obtained with Nordex N80–2.5 MW as 14233.53 kW/year in Kano, the lowest is in Yelwa having 618.06 kW/year for Suzlon S52. It is further shown that the highest capacity factor is 64.95% for Suzlon S52–600 kW in Kano while the lowest is 3.82% for Vestas V80–2 MW in Yelwa.  相似文献   

10.
Energy crisis has led the communities around the world to use energy hubs. These energy hubs usually consist of photovoltics, wind turbines and batteries. Diesel generators are usually used in these systems as backup system. In this research, for the first time, an attempt is made to replace the traditional diesel only backup system with hydrogen only system and combined hydrogen and diesel backup system in hybrid photovoltaic and wind turbine energy systems. After introducing the available energy modeling tools and methods, explaining over advantages and disadvantages of each one, HOMER software was selected for this research. The simulations of this research show that using the traditional diesel generator as the backup system of the energy hub, creates a low cost system with the net present cost (NPC) of 2.5 M$ but also produces the highest amount carbon emission which is equal to 686 tons/year. The results of this study also indicate the hybrid renewable energy system which is supported by the hydrogen only backup system has the highest net present cost (NPC) and initial capital cost but reduces the maximum amount of carbon. The calculated NPC and carbon production of the energy hub using hydrogen only backup system are equal to 4.39 M$ and 55,205, respectively. On the other hand, the combined hydrogen/diesel backup system has reduced NPC compared with the hydrogen only backup system. The CO2 production of this system is also lower than the diesel only backup system. The calculations indicate that the NPC and CO2 production of the combined backup system are 3.53 M$ and 511,695 kg/yr. By comparing advantages and disadvantages of all 3 scenarios, the micro grid which uses the combined diesel/hydrogen backup system is selected as the most optimal system. The sensitivity analysis of the selected system shows that fluctuations of inflation rate along with the fluctuations of both fuel cells and electrolyzers capital cost do not affect the net present cost (NPC) considerably. On the other hand, fluctuations of capital cost of the main components like wind turbines affect the NPC much more than the others. If the inflation rate drops from 15% to 14% and wind turbine capital cost multiplier reduces from 1 to 0.8, the NPC value will drop by the value of 300,000 $.  相似文献   

11.
In this study, wind characteristic and wind energy potential of the Uluda? skinning which is located in the south Marmara region of Turkey were analyzed using the wind speed data collected during the period 2000–2006. The wind speed distribution curves of Uluda?-Bursa were obtained by using the Weibull and Rayleigh probability density functions. The average Weibull shape parameter k and scale parameter c were found as 1.78 and 7.97 m/s for the period 2000–2006. The yearly mean wind speed in Uluda?-Bursa was obtained as 7.08 m/s for period of 7 years. A technical and economic assessment has been made of electricity generation from four wind turbines having capacity of (600, 1000, 1500 and 2000 kW). The yearly energy output, capacity factor and the electrical energy cost of kW h produced by the three different turbines were calculated. The cost of each kW h produced using the chosen wind turbines in Uluda?-Bursa were found to between 0.255 and 0.306 $/kW h.  相似文献   

12.
In this study, a hybrid system consisted of 10 kW wind and 1 kWp PV array is built to meet the load demand of a raise chucker partridge raising facility by renewable energy sources. The facility has an average energy consumption of about 20.33 kWh/day, with a peak demand of 2.4 kW. The solar radiation data and wind data of the region are analyzed for sizing of the renewable energy system. The performance of each alternative system is examined in terms of energy efficiency, and H2 production capacity of the hybrid system from due to excessive electrical energy is studied. A Matlab-Simulink Software is used for analyzing the system performance. The average range of state of charge varies between 56.6% and 88.3% monthly from April to July. The amount of hydrogen production by excess electricity is 14.4 kg in the month of July, due to the high wind speed and solar radiation. Energy efficiency of the electrolyser is found to be varying between 64% and 70% percent. Energy efficiency of each hybrid system is calculated. The overall energy efficiency of wind-electrolyser system varies between 5% and 14% while the energy efficiency of PV-electrolyser system changes within a narrower range, as between 7.9% to and 8.5%, respectively.  相似文献   

13.
In the examined paper, a solar and wind energy supported integrated cycle is designed to produce clean power and hydrogen with the basis of a sustainable and environmentally benign. The modeled study mainly comprises of four subsystems; a solar collector cycle which operates with Therminol VP1 working fluid, an organic Rankine cycle which runs with R744 fluid, a wind turbine as well as hydrogen generation and compression unit. The main target of this work is to investigate a thermodynamic evaluation of the integrated system based on the 1st and 2 nd laws of thermodynamics. Energetic and exergetic efficiencies, hydrogen and electricity generation rates, and irreversibility for the planned cycle and subsystems are investigated according to different parameters, for example, solar radiation flux, reference temperature, and wind speed. The obtained results demonstration that the whole energy and exergy performances of the modeled plant are 0.21 and 0.16. Additionally, the hydrogen generation rate is found as 0.001457 kg/s, and the highest irreversibility rate is shown in the heat exchanger subcomponents. Also, the net power production rate found to be 195.9 kW and 326.5 kW, respectively, with organic Rankine cycle and wind turbine. The final consequences obtained from this work show that the examined plant is an environmentally friendly option, which in terms of the system's performance and viable, for electrical power and hydrogen production using renewable energy sources.  相似文献   

14.
Renewable and carbon free energy relates to the sustainable development of human beings while hydrogen production by renewables and hydrogen underground storage ensure the stable and economic renewable energy supply. A hybrid energy system combining hydrogen production by offshore wind power with hydrogen storage in depleted oil reservoirs was constructed along with a mathematical model where the Weibull distribution, Wind turbine power function, Faraday's law, continuity equation, Darcy's law, state equation of real gas, Net Present Value (NPV) and the concept of leveling were adopted to clarify the system characteristics. For the case of a depleted oil field in the Bohai Bay, China, the annual hydrogen production, annual levelized cost of hydrogen and payback period are 2.62 × 106 m³, CNY 34.6/kgH2 and 7 years, respectively. Sensitivity analysis found that the wind speed impacted significantly on system NPV and LCOH, followed by hydrogen price and stratum pressure.  相似文献   

15.
The technical and economic feasibility study of an innovative wind–solar hybrid renewable energy generation system with rainwater collection feature for electrical energy generation is presented in this paper. The power generated would supply part of the energy requirements of the high-rise building where the system is installed. The system integrates and optimizes several green technologies; including urban wind turbine, solar cell module and rain water collector. The design was conceptualized based on the experiences acquired during the development and testing of a suitable wind turbine for Malaysian applications. It is compact and can be built on top of high-rise buildings in order to provide on-site renewable power to the building. It overcomes the inferior aspect on the low wind speed by channeling and increasing the speed of the high altitude free-stream wind through the power-augmentation-guide-vane (PAGV) before it enters the wind turbine at the center portion. The shape or appearance of the PAGV that surrounds the wind turbine can be blended into the building architecture without negative visual impact (becomes part of the building). The design improves the starting behavior of wind turbines. It is also safer to people around and reduces noise pollution. The techno-economic analysis is carried out by applying the life cycle cost (LCC) method. The LCC method takes into consideration the complete range of costs and makes cash flows time-equivalent. The evaluations show that for a system with the PAGV (30 m diameter and 14 m high) and an H-rotor vertical axis wind turbine (17 m diameter and 9 m high) mounted on the top of a 220 m high building, the estimated annual energy savings is 195.2 MW h/year.  相似文献   

16.
Due to the threat of climate change, renewable feedstocks & alternative energy carriers are becoming more necessary than ever. One key vector is hydrogen, which can fulfil these roles and is a renewable resource when split from water using renewable electricity. Electrolyzers are often not designed for variable operation, such as power from sources like wind or solar. This work develops a framework to optimize the design and operation of a large-scale electrolyzer hub under variable power supply. The framework is a two-part optimization, where designs of repeated, modular units are optimized, then the entire system is optimized based on those modular units. The framework is tested using a case study of an electrolyzer hub powered by a Dutch wind farm to minimize the levelized cost of hydrogen. To understand how the optimal design changes, three power profiles are examined, including a steady power supply, a representative wind farm power supply, and the same wind farm power supply compressed in time. The work finds the compressed power profile uses PEM technology which can ramp up and down more quickly. The framework determines for this case study, pressurized alkaline electrolyzers with large stacks are the cheapest modular unit, and while a steady power profile resulted in the cheapest hydrogen, costing 4.73 €/kg, the typical wind power profile only raised the levelized cost by 2%–4.82 €/kg. This framework is useful for designing large-scale electrolysis plants and understanding the impact of specific design choices on the performance of a plant.  相似文献   

17.
More than one third of world population has no direct access to interconnected electrical networks. Hence, the electrification solution usually considered is based on expensive, though often unreliable, stand-alone systems, mainly small diesel-electric generators. Hybrid wind–diesel power systems are among the most interesting and environmental friendly technological alternatives for the electrification of remote consumers, presenting also increased reliability. More precisely, a hybrid wind–diesel installation, based on an appropriate combination of a small diesel-electric generator and a micro-wind converter, offsets the significant capital cost of the wind turbine and the high operational cost of the diesel-electric generator. In this context, the present study concentrates on a detailed energy production cost analysis in order to estimate the optimum configuration of a wind–diesel-battery stand-alone system used to guarantee the energy autonomy of a typical remote consumer. Accordingly, the influence of the governing parameters—such as wind potential, capital cost, oil price, battery price and first installation cost—on the corresponding electricity production cost is investigated using the developed model. Taking into account the results obtained, hybrid wind–diesel systems may be the most cost-effective electrification solution for numerous isolated consumers located in suitable (average wind speed higher than 6.0 m/s) wind potential regions.  相似文献   

18.
The performance of a hybrid wind–solar power plant in southwestern Minnesota is modeled for a 2-yr period using hourly wind and solar insolation data. The wind portion of the plant consists of four interconnected wind farms within a radius of 90 km. The solar component of the plant is a parabolic trough solar thermal electric generating system using a heat transfer fluid that drives a steam turbine. The market value of energy produced, retail value of energy produced, and levelized cost of energy of the hybrid plant are compared to those of an energy equivalent wind-only plant. Results show that adding solar thermal electric generating capacity to a wind farm rather than expanding with additional wind capacity provides cost–benefit trade-offs that will continue to change as the two technologies evolve. At the present time, we find that capital cost and levelized cost of energy favor a wind-only plant while electric load matching favors a hybrid wind–solar plant. Regional differences in the solar resource in the US influence the economic viability of the hybrid plant, and a comparison using the present model is made with one location in the Southwest. The hourly data analysis presented here is a possible tool for evaluating the overall economic feasibility and generating characteristics for a hybrid wind–solar thermal electric power plant for any location with available wind, solar, electric load, and price data.  相似文献   

19.
Hydrogen is acclaimed to be an energy carrier of the future. Currently, it is mainly produced by fossil fuels, which release climate-changing emissions. Thermochemical cycles, represented here by the hybrid-sulfur cycle and a metal oxide based cycle, along with electrolysis of water are the most promising processes for ‘clean’ hydrogen mass production for the future. For this comparison study, both thermochemical cycles are operated by concentrated solar thermal power for multistage water splitting. The electricity required for the electrolysis is produced by a parabolic trough power plant. For each process investment, operating and hydrogen production costs were calculated on a 50 MWth scale. The goal is to point out the potential of sustainable hydrogen production using solar energy and thermochemical cycles compared to commercial electrolysis. A sensitivity analysis was carried out for three different cost scenarios. As a result, hydrogen production costs ranging from 3.9–5.6 €/kg for the hybrid-sulfur cycle, 3.5–12.8 €/kg for the metal oxide based cycle and 2.1–6.8 €/kg for electrolysis were obtained.  相似文献   

20.
This paper analyzes the feasibility of solar chimney power plants as an environmentally acceptable energy source for small settlements and islands of countries in the Mediterranean region. For the purpose of these analyses, two characteristic geographic locations (Split and Dubrovnik) in Croatia were chosen and simplified model for calculation of produced electric power output is also developed. These locations possess typical characteristics of the Mediterranean climate. The solar characteristics of the chosen geographic locations are shown along with characteristic meteorological data. A solar chimney (SC) power plant with a chimney height of 550 m and a collector roof diameter of 1250 m would produce 2.8–6.2 MW of power. The average annual electric power production of this SC power plant would range between 4.9 and 8.9 GWh/year, but in reality from 5.0 to 6.0 GWh/year in average. An approximate costs analysis, which included a total investment estimate, was performed. The levelized electricity cost was also calculated. It is found that the price of produced electric energy by solar chimney power plant in Mediterranean region is considerably higher compared to the other power sources.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号