首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
We describe a theoretical procedure for analyzing astronomical phased arrays with overlapping beams and apply the procedure to simulate a simple example. We demonstrate the effect of overlapping beams on the number of degrees of freedom of the array and on the ability of the array to recover a source. We show that the best images are obtained using overlapping beams, contrary to common practice, and show how the dynamic range of a phased array directly affects the image quality.  相似文献   

3.
《NDT International》1987,20(6):333-337
Although ultrasonic phased arrays are potentially ideally suited to many applications in NDT, their use in practice is limited by the complexity of array probe manufacture and the bulk and cost of the associated electronic control instrumentation. In this article a number of probe designs are discussed, with particular emphasis being placed on those having a simpler construction. The requirements of the electronic systems for both transmission and reception of array signals are reviewed. A compact, low-cost, phased-array instrument which compromises between array probe scanning speed and the rate of data acquisition is also described.  相似文献   

4.
Extremely large telescopes are currently under consideration by several groups in several countries. Extrapolation of current technology up to 30 m indicates a cost of over dollars 1 billion. Innovative concepts are being explored to find significant cost reductions. We explore the concept of an Optical Phased Array (OPA) telescope. Each element of the OPA is a separate Cassegrain telescope. Collimated beams from the array are sent via an associated set of delay lines to a central beam combiner. This array of small telescope elements offers the possibility of starting with a low-cost array of a few rings of elements, adding structure and additional Cass elements until the desired diameter telescope is attained. We address the salient features of such an extremely large telescope and cost elements relative to more conventional options.  相似文献   

5.
Weverka RT  Wagner K  Sarto A 《Applied optics》1996,35(8):1344-1366
An adaptive null-steering phased-array optical processor that utilizes a photorefractive crystal to time integrate the adaptive weights and null out correlated jammers is described. This is a beam-steering processor in which the temporal waveform of the desired signal is known but the look direction is not. The processor computes the angle(s) of arrival of the desired signal and steers the array to look in that direction while rotating the nulls of the antenna pattern toward any narrow-band jammers that may be present. We have experimentally demonstrated a simplified version of this adaptive phased-array-radar processor that nulls out the narrow-band jammers by using feedback-correlation detection. In this processor it is assumed that we know a priori only that the signal is broadband and the jammers are narrow band. These are examples of a class of optical processors that use the angular selectivity of volume holograms to form the nulls and look directions in an adaptive phased-array-radar pattern and thereby to harness the computational abilities of three-dimensional parallelism in the volume of photorefractive crystals. The development of this processing in volume holographic system has led to a new algorithm for phased-array-radar processing that uses fewer tapped-delay lines than does the classic time-domain beam former. The optical implementation of the new algorithm has the further advantage of utilization of a single photorefractive crystal to implement as many as a million adaptive weights, allowing the radar system to scale to large size with no increase in processing hardware.  相似文献   

6.
The feasibility of using intracavitary ultrasound phased arrays for thermal surgery of the prostate was investigated. A simulation study was performed which demonstrated the ability of phased arrays to generate necrosed tissue volumes over anatomically appropriate ranges (2-6 cm deep and >6 cm axially) and investigated the effects of varying frequency, sonication time, maximum temperature, and blood perfusion on the necrosed tissue volume. An advantage that phased arrays have over geometrically focused transducers is that they are able to electronically scan a single focus over a specified range very quickly. This study demonstrated that the necrosed tissue volume may be increased by more than a factor of 100 by using electronic scanning. Scan parameters that were investigated included foci spacing, scan width, perfusion, maximum temperature, and unequal weighting of the foci. An optimization was performed to select the foci weighting parameters such that a uniform thermal dose was achieved at the focal depth, providing a more uniformly heated target volume. Finally, the ability of linear ultrasound phased arrays to create necrosed tissue lesions was demonstrated experimentally in fresh beef liver using a single stationary focus and single focus scans generated by an aperiodic 0.83-MHz 57-element linear ultrasound phased array  相似文献   

7.
A 64-element, high efficiency, ceramic piezoelectric array transducer operating at 20 MHz has been constructed for ultrasonic intraluminal imaging. The array is mounted on the surface of a 1.2 mm diameter catheter appropriate for coronary artery applications. Integrated into the catheter tip is a custom analog chip set permitting complete data capture from the array. That is, on each firing any combination of array elements can be selected independently as transmitter or receiver. Using data acquired in this way, a complete phased array aperture (i.e., independent transmit and receive apertures) can be synthesized. Reconstruction hardware based on a custom application specific integrated circuit (ASIC) has been designed and built to produce real-time images. Beam forming coefficients are derived using an optimal filtering approach accounting for the circular geometry of the array. Simulated and measured beam patterns for this system are compared. In addition, images of coronary anatomy acquired with the real-time system are displayed demonstrating the marked image quality improvement compared to previous synthetic aperture intraluminal systems  相似文献   

8.
Optically produced true-time delays for phased antenna arrays   总被引:2,自引:0,他引:2  
A device is described for generating true-time delays optically for microwave signals used in beam steering and beam shaping in phased-array antennas. The device can be adapted to provide delays from picoseconds to nanoseconds. A single, compact unit should provide parallel delays for more than 64 independent antenna elements with a greater than 6-bit resolution. The time delays are produced by multiple reflections in a mirror configuration with continuous refocusing. A single spatial light modulator selects independent optical path lengths for each of the parallel antenna elements. Amplitude control for beam shaping can be integrated into the device. The unit can be made rugged for harsh environments by use of solid-block construction. The operation of the true-time delay device is described, along with the overall system configuration. Preliminary experimental data are given.  相似文献   

9.
Treatment planning for hyperthermia with ultrasound phased arrays   总被引:2,自引:0,他引:2  
Treatment planning for ultrasound phased arrays suggests a strategy for hyperthermia therapy which satisfies therapeutic conditions at the target and spares other sensitive anatomical structures. To predict both desirable and harmful interactions between ultrasound and important structures such as the tumor, bones, and air pockets, a hyperthermia treatment planning system has been developed for ultrasound phased arrays. This collection of treatment planning routines consists of geometric and thermal optimization procedures specific to ultrasound phased arrays, where geometric treatment planning, combined with thermal treatment planning and three-dimensional visualization, provides essential information for the optimization of individual patient treatments. A patient image data set for cancer of the prostate, a difficult target situated in the midst of multiple pelvic bone obstructions, illustrates the geometric treatment planning algorithm and other tools for treatment analysis. The results indicate that the analysis of complex three-dimensional relationships between the applicator, anatomical structures, and incident fields provides an important means of predicting treatment limiting conditions, thereby allowing the hyperthermia applicator to electronically adapt to individual patients and specific sites  相似文献   

10.
Lucke RL 《Applied optics》1999,38(22):4776-4783
When beams from an array of afocal telescopes are presented to a beam-combining telescope, tilt errors of the beam wave fronts with respect to the combined wave front place limits on the achievable field of view (FOV); these limits, to the best of our knowledge, have not previously been correctly described in the literature. We show that if the front-end telescopes have just the right Seidel distortion coefficient, then tilt error does not limit the FOV. If this is not the case, at least small FOV's can still be obtained, even if the FOV is not centered on the on-axis direction.  相似文献   

11.
研究了提高非致命次声武器聚束能力和声强增益的方法。利用抛物面本身的自聚焦性能优化设计了一种新型的抛物面不等间距阵列。基于声场理论,计算出阵列声压分布;采用伪逆矩阵算法,数值仿真了与抛物面阵列中心轴垂直截面上以及中心轴上不同位置的声压分布。研究结果表明,不等间距抛物面相控阵列相对于传统平面阵列而言,声强分布的半峰宽度减小了16.7%,并且声强增益提高了48.6%,是较为理想的组合声源。通过仿真模拟论证了抛物面阵列的优越性,进而为次声武器的设计及研究提供了理论基础。  相似文献   

12.
13.
The purpose of this paper was to evaluate the in vivo feasibility of using phased arrays for MRI guided ultrasound surgery. Two different array concepts were investigated: a spherically curved concentric ring array to move the focus along the central axis and a spherically curved 16 square element array to make the focus larger. Rabbit thigh muscles were exposed in vivo in a 1.5 T MRI scanner to evaluate the array performance. The results showed that both of the arrays performed as expected, and the focus could be moved and enlarged. In addition, adequate power could be delivered from the arrays to necrose in vivo muscle tissue in 10 s. This study was the first implementation of phased arrays for MRI guided ultrasound surgery. The results demonstrate that phased arrays have significant potential for noninvasive tissue coagulation  相似文献   

14.
This paper discusses research in the use of biologically inspired spatial phased transducer arrays for the nondestructive evaluation of homogeneous and heterogeneous structural components. It is shown that beamforming, which is used by orb web spiders to locate their prey in a network of web fibers, can be achieved by applying weights and time delays to the tapped signals from a transducer array in a narrow frequency band to obtain desired directional sensitivities and optimal array gains. The resulting spatio-temporal filters are then used to detect, locate and quantify structural damage. The theory of beamsteering and beamforming for processing propagating wave data in damaged elastic media is discussed. Experimental results for homogeneous and heterogeneous plates are given to verify the theoretical discussions. Design considerations for the phased arrays are examined as are the benefits of nonlinear array geometries for better spatial coverage. The advantage of using adaptive over conventional beamforming is demonstrated with a Frost Constraint adaptive technique.  相似文献   

15.
Ultrasonic arrays are increasingly widely used in nondestructive evaluation (NDE) due to their greater flexibility and potentially superior performance compared to conventional monolithic probes. The characterization of small defects remains a challenge for NDE and is of great importance for determining the impact of a defect on the integrity of a structure. In this paper, a technique for characterizing reflectors with subwavelength dimensions is described. This is achieved by post-processing the complete data set of time traces obtained from an ultrasonic array using two algorithms. The first algorithm is used to obtain information about reflector orientation and the second algorithm is used to distinguish between point-like reflectors that reflect uniformly in all directions and specular reflectors that have distinct orientations. Experimental results are presented using a commercial 64-element, 5-MHZ array on two aluminum test specimens that contain a number of machined slots and side-drilled holes. The results show that the orientation of 1-mm-long slots can be determined to within a few degrees and that the signals from 1-mm-long slots can be distinguished from that from a 1-mm-diameter circular hole. Techniques for quantifying both the orientation and the specularity of measured signals are presented and the effect of processing parameters on the accuracy of results is discussed.  相似文献   

16.
An ultrasonic applicator, which utilizes both electronic and variable geometric focusing, for deep-localized hyperthermia is investigated. The applicator is based around a linear phased array that furnishes its electronic focusing capability. The output of the array radiates through a spherical liquid-lens that provides the applicator a variable geometric focusing capability as well. A lens of this type adds dynamic focusing to the elevation dimension of the linear phased array. By controlling the volume of liquid in the lens (and thus the radius of curvature of its membrane), dynamic control of the geometrical focus can be achieved. Comparisons of computer simulations and experimental measurements of the field intensity distribution of a small-scale prototype applicator are presented. Important design parameters, such as the choice of the liquid for the lens and the size and number of array elements, are examined.  相似文献   

17.
With the introduction of harmonic imaging, the design of new array transducers for tissue and contrast imaging became indispensable. Hence, prior knowledge of harmonic beams is essential to attain optimal harmonic performances. For that purpose, a new numerical algorithm that solves the parabolic nonlinear wave equation is developed. The algorithm is based on finite differences and performs exclusively in time domain. Pulsed harmonic fields emitted by a medical transducer were measured and computed at different mechanical indices. Simulations and measurements showed very good agreement for all the harmonic components.  相似文献   

18.
To be able to describe more precisely the behavior of a real-time 3-D ultrasound system with either a dense array or various sparse designs, experimental data from a 2-D fully connected array prototype with 50/spl times/50 elements have been collected. The data have been processed off line to form synthetic aperture 3-D volume images. Simulated and experimental results are compared and show good correlation. The performance of the best sparse designs, all thinned to more than 50%, offer performances comparable to a dense array.  相似文献   

19.
Sparse 2-D arrays for 3-D phased array imaging--design methods   总被引:2,自引:0,他引:2  
One of the most promising techniques for limiting complexity for real-time 3-D ultrasound systems is to use sparse 2-D layouts. For a given number of channels, optimization of performance is desirable to ensure high quality volume images. To find optimal layouts, several approaches have been followed with varying success. The most promising designs proposed are Vernier arrays, but also these suffer from high peaks in the sidelobe region compared with a dense array. In this work, we propose new methods based on the principles of suppression of grating lobes to form symmetric and non-symmetric regular sparse periodic and radially periodic designs. The proposed methods extend the concept of sparse periodic layouts by exploiting either an increased number of symmetry axes or radial symmetry. We also introduce two new strategies to form designs with nonoverlapping elements. The performance of the new layouts range from the performance of Vernier arrays to almost that of dense arrays. Our designs have simplicity in construction, flexibility in the number of active elements, and the possibility of trade off sidelobe peaks against sidelobe energy.  相似文献   

20.
In this work, a novel procedure that considerably simplifies the fabrication process of ferroelectret-based multi-element array transducers is proposed and evaluated. Also, the potential of ferroelectrets being used as active material for aircoupled ultrasonic transducer design is demonstrated. The new construction method of multi-element transducers introduces 2 distinctive improvements. First, active ferroelectret material is not discretized into elements, and second, the need of structuring upper and/or lower electrodes in advance of the permanent polarization of the film is removed. The aperture discretization and the mechanical connection are achieved in one step using a through-thickness conductive tape. To validate the procedure, 2 linear array prototypes of 32 elements, with a pitch of 3.43 mm and a wide usable frequency range from 30 to 300 kHz, were built and evaluated using a commercial phased-array system. A low crosstalk among elements, below -30 dB, was measured by interferometry. Likewise, a homogeneous response of the array elements, with a maximum deviation of plusmn1.8 dB, was obtained. Acoustic beam steering measurements were accomplished at different deflection angles using a calibrated microphone. The ultrasonic beam parameters, namely, lateral resolution, side lobe level, grating lobes, and focus depth, were congruent with theory. Acoustic images of a single reflector were obtained using one of the array elements as the receiver. Resulting images are also in accordance with numerical simulation, demonstrating the feasibility of using these arrays in pulse-echo mode. The proposed procedure simplifies the manufacturing of multidimensional arrays with arbitrary shape elements and not uniformly distributed. Furthermore, this concept can be extended to nonflat arrays as long as the transducer substrate conforms to a developable surface.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号