首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
集成熔盐储热是有望大幅提高燃煤发电机组运行灵活性的有效手段。本文针对集成熔盐储热的燃煤发电系统,建立了变工况模型与火用分析模型,针对以再热蒸汽为热源且加热熔盐后分别返回低压缸入口和凝汽器的两种熔盐储热系统,研究获得了燃煤机组运行灵活性和能耗特性的变化规律。结果表明:采用不同储热系统构型对燃煤机组的灵活性与能耗特性的影响差异明显。集成两种熔盐储热系统,燃煤机组的最低工作负荷从额定负荷的30%分别降低到20.58%与24.43%,系统火用损失则分别增加了48.67 MW与18.7 MW。  相似文献   

2.
Generation expansion planning (GEP) is a power plant mix problem that identifies what, where, when, and how new generating facilities should be installed and when old units be retired over a specific planning horizon. GEP ensures that the quantity of electricity generated matches the electricity demand throughout the planning horizon. This kind of planning is of importance because most production and service delivery is dependent on availability of electricity. Over the years, the traditional GEP approaches have evolved to produce more realistic models and new solution algorithms. For example, with the agitation for green environment, the inclusion of renewable energy plants and energy storage in the traditional GEP model is gradually gaining attention. In this regards, a handful of research has been conducted to identify the optimal expansion plans based on various energy‐related perspectives. The appraisal and classification of studies under these topics are necessary to provide insights for further works in GEP studies. This article therefore presents a comprehensive up‐to‐date review of GEP studies. Result from the survey shows that the integration of demand side management, energy storage systems (ESSs), and short‐term operational characteristics of power plants in GEP models can significantly improve flexibility of power system networks and cause a change in energy production and the optimal capacity mix. Furthermore, this article was able to identify that to effectively integrate ESS into the generation expansion plan, a high temporal resolution dimension is essential. It also provides a policy discussion with regard to the implementation of GEP. This survey provides a broad background to explore new research areas in order to improve the presently available GEP models.  相似文献   

3.
Expanders employed recently in organic Rankine cycle (ORC)‐based systems suffer from key problems including excessive working fluid leakage, thermal losses, low isentropic efficiency and high cost. The majority of the units available in the market are for medium and large‐scale applications (>100 kW) with no commercial micro‐scale expanders available and applicable for ORC units for residential and building applications. Moreover, the majority of the studies conducted on ORC expanders employed HFC and HCFC working fluids which have high global warming potential leading to negative environmental impacts. In this study, a micro‐scale CHP system based on the ORC technology is theoretically and experimentally investigated to provide the thermal needs and part of the electrical demands for residential applications. An innovative design for a hybrid ORC‐based micro‐CHP system is proposed using a biomass boiler and a solar concentrator to run the CHP system providing more reliable and clean operation compared to conventional natural gas‐driven units. The micro‐CHP system employs a new type small‐scale scroll expander with a compact design, integrating the generator and the turbine in a single unit. A numerical model was developed using the Engineering Equation Solver (EES) software to simulate the thermodynamic behaviour of the ORC unit predicting the thermal and electrical performance of the overall CHP system. In addition, an experimental setup was built to test the whole ORC–CHP system performance under different conditions, and the effect of various operational parameters on the system performance has been presented using an environmentally friendly HFE7100 working fluid. The maximum electric power generated by the expander was in the range of 500 W at a pressure differential of about 4.5 bars. The attained expander isentropic efficiency was over 80% at its peak operating conditions with no fluid leakage observed. Being mass‐produced with low cost in the automotive industry along with the high isentropic efficiency and the leakage‐free performance, the proposed compact scroll expander represents a potential candidate to be used in the development of micro‐scale ORC–CHP units for building applications. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

4.
Energy and exergy analysis were carried out for a combined‐cycle power plant by using the data taken from its units in operation to analyse a complex energy system more thoroughly and to identify the potential for improving efficiency of the system. In this context, energy and exergy fluxes at the inlet and the exit of the devices in one of the power plant main units as well as the energy and exergy losses were determined. The results show that combustion chambers, gas turbines and heat recovery steam generators (HRSG) are the main sources of irreversibilities representing more than 85% of the overall exergy losses. Some constructive and thermal suggestions for these devices have been made to improve the efficiency of the system. Copyright © 2005 John Wiley & Sons, Ltd.  相似文献   

5.
为了解决用户负荷需求在时间上的变动和传统冷热电联供(Combine Cooling, Heating & Power, CCHP)系统大部分时间处于非设计工况下运行导致系统的能源利用效率较低的问题,提出了一种耦合压缩空气储能系统(Compressed Air Energy Storage system, CAES)和蓄热装置的新型CCHP系统(CAES based CCHP system,CAES CCHP),建立系统的热力学模型,在给定的充、放电工作条件下对CAES CCHP系统的热力学性能进行分析,并对影响该系统性能的CAES压气机压缩比、透平进气口压力、流经CAES的烟气质量流量3个关键参数进行敏感性分析。研究结果表明:CAES CCHP系统能实现冷热电灵活调控,且系统的CAES功转换效率为57.41%,一次能源利用率、一次节能率及火用效率分别为76.22%,24.84%和31.97%,比传统的CCHP系统分别提高10.97%,18.15%和7.58%。  相似文献   

6.
Advancing in the learning curve of solar thermal power plants (STPP) requires detailed analysis for reducing exergy losses in the energy conversion chain. This requirement should be applied to any configuration proposed for the solar field and the power block. The aim of this work is to perform this type of analysis for two ways of structuring the power plant. The first plant structure consists of a subdivision of the solar collector field into specialized sectors with specific goals conveying different requirements in temperature. The second plant structure is based on a dual thermal energy storage system with a defined hierarchy in the storage temperature. The subdivision of the solar field into different sectors reduces the exergy losses in the heating process of the working fluid. Moreover, the average temperature of the heat transfer fluid in the solar field decreases when it is compared to the conventional solar field, reducing this way the exergy losses in the collectors. The dual thermal energy storage system is devised for keeping the exergy input to the power block at its nominal level for long periods of time, including post‐sunset hours. One of the storage systems gathers a fluid heated up to temperatures above the nominal value and the second one is the classical one. The combination of both allows the manager of the plant to keep the nominal operation of the plant for longer periods than in the case of classical system. Numerical simulations performed with validated models are the basis of the exergy analyses. The configurations are compared to a reference STPP in order to evaluate their worth. Furthermore, the behaviour of the configurations is analysed to study the irreversibility of the included devices. Special attention is paid to the storage systems, as they are a key issue in both plant structures. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

7.
Combined heat and power (CHP) plants dominate the heating market in China. With the ongoing energy structure reformation and increasing environmental concerns, we propose gas-fired boilers to be deployed in underperforming heating substations of heating networks for peak load compensation, in order to improve both energy efficiency and environmental sustainability. However, due to the relatively high price of gas, techno-economic analysis is required for evaluating different combined heating scenarios, characterized by basic heat load ratio (β). Therefore, we employ the dynamic economics and annual cost method to develop a techno-economic model for computing the net heating cost of the system, considering the current state of the art of cogeneration systems in China. The net heating cost is defined as the investment costs and operations costs of the system subtracted by revenues from power generation. We demonstrate the model in a real-life combined heating system of Daqing, China. The results show that the minimum net heating cost can be realized at β=0.75 with a cost reduction of 16.8% compared to coal heating alone. Since fuel cost is the dominating factor, sensitivity analyses on coal and gas prices are discussed subsequently.  相似文献   

8.
In order to provide adequate engineering assistance and to improve the energy efficiency in process industries, it is crucial to evaluate the operational performance of a boiler in terms of its practical requirements, viz. temperature, pressure, and mass flow rate of steam. This study was aimed at assessing and optimizing the performance of a refuse plastic fuel‐fired boiler using artificial neural networks. A feed‐forward back propagation neural network model was developed and trained using existing plant data (5 months), to predict temperature, pressure, and mass flow rate of steam, using the following input parameters: feed water pressure, feed water temperature, conveyor speed, and incinerator exit temperature. The predictive capability of the model was evaluated in terms of mean absolute percentage error between the model fitted and actual plant data, while sensitivity analysis was performed on the input parameters by determining the absolute average sensitivity values. The higher absolute average sensitivity value of the incinerator exit temperature in comparison to that of feed water pressure, feed water temperature and conveyor speed suggested that the change of incineration exit temperature has a significant influence on the selected outputs (steam properties). Overall, the good results observed from this work demonstrate the fact that artificial neural networks can efficiently predict the data on steam properties and could serve as a good tool to monitor boiler behavior under real‐time conditions. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

9.
This paper presents a theoretical analysis and an experimental test on a shell‐and‐tube latent heat storage exchanger. The heat exchanger is used to recover high‐temperature waste heat from industrial furnaces and off‐peak electricity. It can also be integrated into a renewable energy system as an energy storage component. A mathematical model describing the unsteady freezing problem coupled with forced convection is solved numerically to predict the performance of the heat exchanger. It provides the basis for an optimum design of the heat exchanger. The experimental study on the heat exchanger is carried out under various operating conditions. Effects of various parameters, such as the inlet temperature, the mass flow rate, the thickness of the phase‐change material and the length of the pipes, on the heat transfer performance of the unit are discussed combined with theoretical prediction. The criterion for analyzing and evaluating the performance of heat exchanger is also proposed. Copyright © 2001 John Wiley & Sons, Ltd.  相似文献   

10.
针对综合能源系统内的燃气多联供展开稳态建模研究,结合成本模型及收益模型开展机组经济性分析。选取GE公司6F.03燃机,研究了燃气多联供机组的供热功率及供电功率耦合关系,开展了包含天然气价格、蒸汽销售价格、蒸汽抽取量、年利用小时数和上网电价在内的多因素敏感性分析。结果表明:通过外供蒸汽流量调节,可满足不同供热及供电功率需求,当外供20 t/h蒸汽时,可提供16.17 MW的供热功率及109 MW供电功率;天然气价格敏感性分析表明,要实现低于10年的投资回收期,应将天然气价格控制在3.25元/m~3以内;增大蒸汽供应量能够提高机组的经济性;上网电价的敏感性最为显著,当低于0.5元/(kW·h),投资回收期会超过24年,但当上网电价达到0.7元/(kW·h),投资回收期可降低至5年。  相似文献   

11.
An Erratum has been published for this article in International Journal of Energy Research 2004; 28 (13): 1213. This paper deals with the simulation of thermal energy storage (TES) system for HVAC applications. TES is considered to be one of the most preferred demand side management technologies for shifting cooling electrical demand from peak daytime hours to off peak night hours. TES is incorporated into the conventional HVAC system to store cooling capacity by chilling ethylene glycol, which is used as a storage medium. The thermodynamic performance is assessed using exergy and energy analyses. The effects of various parameters such as ambient temperature, cooling load, and mass of storage are studied on the performance of the TES. A full storage cycle, with charging, storing and discharging stages, is considered. In addition, energy and exergy analysis of the TES is carried out for system design and optimization. The temperature in the storage is found to be as low as 6.4°C after 1 day of charging without load for a mass of 250 000 kg. It is found that COP of the HVAC system increases with the decrease of storage temperature. Energy efficiency of the TES is found to be 80% for all the mass flow rate of the discharging fluid, whereas exergy efficiency varies from 14 to 0.5%. This is in fact due to the irreversibilities in a TES process destroy a significant amount of the input exergy, and the TES exergy efficiencies therefore become always lower than the corresponding energy efficiencies. Copyright © 2004 John Wiley & Sons, Ltd.  相似文献   

12.
An important method to increase the efficiency of thermal power plants is to recover the exhaust gas heat at the boiler cold‐end with the stepwise integration of a steam turbine heat regenerative system. To this end, there are currently three typical heat recovery processes, that is, a low‐temperature economizer (LTE), segmented air heating (SAH) and bypass flue (BPF). To provide useful guidance to thermal power plants for optimal and efficient processes, the thermal economy and techno‐economic performance of the three aforementioned processes were calculated and compared using an in‐service 600‐MW hard‐coal‐fired ultra‐supercritical power unit as a reference. The results demonstrate that with the use of the LTE, SAH and BPF, respectively, to recover the exhaust heat, reducing the exhaust temperature from 122 °C to 90 °C, the net standard coal consumption rate of the 600‐MW unit can be reduced by 1.51, 1.71 and 2.81 g/(kW h). The initial costs of the three heat recovery projects are 1.69, 2.91 and 2.53 million USD. If the 600‐MW unit runs 5500 h per year at the rated load, the three processes can increase the earnings of the unit by 0.49, 0.52 and 0.94 million USD from coal savings annually, meaning that their dynamic payback periods are 4.42, 8.66 and 3.29 years, respectively. The results indicate that for a hard‐coal‐fired power unit, the coal savings achieved by exhaust heat recovery are notable. Among the three processes, SAH shows the worst techno‐economic performance because it induces a significant increase in initial costs while obtaining a limited increase in thermal economy, while BPF exhibits the best techno‐economic performance owing to the significant increase in thermal economy. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

13.
A system is proposed to use the combustible waste gas as a supplementary fuel in coal‐fired boilers. The combustion air can be partially or fully substituted by ventilation air methane or diluted combustible waste gases. The recommended volume fraction of combustible waste gas in combustion air is no more than 1.0%. The effect of waste gas introduction on thermodynamic parameters of boiler is evaluated through thermal calculation based on material balance, heat balance, and heat transfer principles. A case study is conducted by referring to a 600 MW supercritical pressure boiler. The results show that no retrofit of boiler is required. The operation of boiler is scarcely influenced, and the original forced and induced draft fans can meet the requirement. With increasing volume fraction of combustible waste gas, the flue gas temperature at the furnace exit decreases monotonically, resulting in an increment of heat absorption in furnace and a decrement of heat transferred in convective heating surfaces. When 1.0% volume fraction of hydrocarbon gas is introduced, the thermal efficiency of boiler is increased by 0.5%, and the coal consumption rate is reduced by 25.4%. The cost analysis of the proposed system is conducted, and break‐even curves are given as references for the utilization of waste gas as a supplementary fuel. The economic velocity of the combustion air is suggested to be 18.2 m s?1.  相似文献   

14.
Because of biomass's limited supply (as well as other issues involving its feeding and transportation), pure biomass plants tend to be small, which results in high production and capital costs (per unit power output) compared with much larger coal plants. Thus, it is more economically attractive to co‐gasify biomass with coal. Biomass can also make an existing plant carbon‐neutral or even carbon‐negative if enough carbon dioxide is captured and sequestered (CCS). As a part of a series of studies examining the thermal and economic impact of different design implementations for an integrated gasification combined cycle (IGCC) plant fed with blended coal and biomass, this paper focuses on investigating various parameters, including radiant cooling versus syngas quenching, dry‐fed versus slurry‐fed gasification (particularly in relation to sour‐shift and sweet‐shift carbon capture systems), oxygen‐blown versus air‐blown gasifiers, low‐rank coals versus high‐rank coals, and options for using syngas or alternative fuels in the duct burner for the heat recovery steam generator (HRSG) to achieve the desired steam turbine inlet temperature. Using the commercial software, Thermoflow®, the case studies were performed on a simulated 250‐MW coal IGCC plant located near New Orleans, Louisiana, and the coal was co‐fed with biomass using ratios ranging from 10% to 30% by weight. Using 2011 dollars as a basis for economic analysis, the results show that syngas coolers are more efficient than quench systems (by 5.5 percentage points), but are also more expensive (by $500/kW and 0.6 cents/kW h). For the feeding system, dry‐fed is more efficient than slurry‐fed (by 2.2–2.5 points) and less expensive (by $200/kW and 0.5 cents/kW h). Sour‐shift CCS is both more efficient (by 3 percentage points) and cheaper (by $600/kW or 1.5 cents/kW h) than sweet‐shift CCS. Higher‐ranked coals are more efficient than lower‐ranked coals (2.8 points without biomass, or 1.5 points with biomass) and have lower capital cost (by $600/kW without using biomass, or $400/kW with biomass). Finally, plants with biomass and low‐rank coal feedstock are both more efficient and have lower costs than those with pure coal: just 10% biomass seems to increase the efficiency by 0.7 points and reduce costs by $400/kW and 0.3 cents/kW h. However, for high‐rank coals, this trend is different: the efficiency decreases by 0.7 points, and the cost of electricity increases by 0.1 cents/kW h, but capital costs still decrease by about $160/kW. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

15.
A peak‐shaving technology is recently proposed, which integrates peak‐electricity generation, cryogenic energy storage and CO2 capture. In such a technology, off‐peak electricity is used to produce liquid nitrogen and oxygen in an air separation and liquefaction unit. At peak hours, natural gas (or alternative gases, e.g. from gasification of coal) is burned by oxygen from the air separation unit (oxy‐fuel combustion) to generate electricity. CO2 produced is captured in the form of dry ice. Liquid nitrogen produced in the air separation plant not only serves as an energy storage medium but also supplies the low‐grade cold energy for CO2 separation. In addition, waste heat from the tail gas can be used to superheat nitrogen in the expansion process to further increase the system efficiency. This article reports a systematic approach, with an aim to provide technical information for the system design. Three potential blending gases (helium, oxygen and CO2) are considered not only for assessing thermodynamic performance but also for techno‐economic analysis. The peak‐shaving systems are also compared with natural gas combined cycle and an oxy–natural gas combined cycle in terms of capital cost and peak electricity production cost. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

16.
When wood chips are available and used to fuel a combined cooling, heating, and power (CCHP) waste heat recovery system, they can represent an economically viable source of biomass energy that can meet a facility's electric and thermal demands. Using a Stirling engine as the CCHP prime mover provides several important advantages over conventional internal combustion engines including no additional processing of the waste wood chips, a potentially higher thermal efficiency, flexibility of fuel sources, and low maintenance. This study shows how the operational characteristics of a constant output, biomass‐fired, Stirling engine‐based CCHP system are affected by the performance of the individual components, including the prime mover, heat recovery system, auxiliary boiler, absorption chiller, and heating coil unit The results are assessed by examining the primary energy consumption and operational cost compared with a reference case. The analysis provides insight on the prime mover sizing and selection of each component to properly implement the system. In addition to examining the effects of each component, the effect of excess electricity production and buyback are considered. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

17.
In recent years, micro combined cooling, heating and power generation (mCCHP) systems have attracted much attention in the energy demand side sector. The input energy of a mCCHP system is natural gas, while the outputs include heating, cooling and electricity energy. The mCCHP system is deemed as a possible solution for households with multiple energy demands. Given this background, a mCCHP based comprehensive energy solution for households is proposed in this paper. First, the mathematical model of a home energy hub (HEH) is presented to describe the inputs, outputs, conversion and consumption process of multiple energies in households. Then, electrical loads and thermal demands are classified and modeled in detail, and the coordination and complementation between electricity and natural gas are studied. Afterwards, the concept of thermal comfort is introduced and a robust optimization model for HEH is developed considering electricity price uncertainties. Finally, a household using a mCCHP as the energy conversion device is studied. The simulation results show that the comprehensive energy solution proposed in this work can realize multiple kinds of energy supplies for households with the minimized total energy cost.  相似文献   

18.
Albeit numerous studies discussing manifold issues of combined cooling, heating and power (CCHP) systems, there is still lack of theoretical studies indicating to what extent the energy mismatch and the deviating working conditions affect the CCHP performance, absence of reports systematically summarizing the multiple effects of energy saving units (ESUs), and deficiency of research quantifying the benefits from ESUs to energy savings. The shortage of such studies will confuse some CCHP designers when a CCHP system is designed. Therefore, in this research, theoretical discussions have been undertaken about the energy mismatch issue between CCHP systems and their users as well as the multiple effects of ESUs on CCHP systems. An improved calculational method of energy storage rate (ESR) has been adopted to evaluate the energy savings performance of CCHP systems. Two general heat‐to‐electricity ratios (Ruser for CCHP users and RCCHP for CCHP systems) have been used to quantify the energy mismatch between CCHP systems and their users. In the regime of ‘priority of providing cooling’, the ESR reaches its maximum when Ruser is equal to RCCHP. Otherwise, the ESR tends to decrease rapidly, especially when the electrical demand must be supplemented from the grid. Furthermore, when the CCHP system produces more electricity than required, the payment mode of extra electricity from the CCHP system will significantly affect the ESR. Therefore, it is imperative to reach an international consensus regarding the dispose of extra CCHP products. The theoretical analyses also corroborate the advantages of incorporating an ESU into a CCHP system. The ESU enables the CCHP system components to operate at their optimal working conditions. Meanwhile, the power generation unit and the absorption refrigerator capacities can then be reduced. Moreover, the ESU also promotes the productivity of electricity and ensures an undiminished ESR regardless of what extra electricity payment mode is adopted. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

19.
This paper deals with the energy production and economics of a large‐scale biomass‐based combined heat and power (CHP) plant. An activity‐based costing model was developed for estimating the production costs of the heat and power of the bio‐CHP. A 100 MW plant (58 MW heat, 29 MW electricity) was used as reference. The production process was divided into four stages: fuel handling, fluidized bed boiler, turbine plant, and flue gas cleaning. The boiler accounted for close to 50% of the production costs. The interest rates and the utilization rate of the CHP had a significant effect on the profitability. We found that below 4000–4500 h per year utilization, the electricity production turned unprofitable. However, the heat production remained profitable with high interest rate (10%) and a low utilization rate (4000 h). The profitability also depended on the type of biomass used. We found that, e.g. with moderate interest rates and high utilization rate of the plant, the bio‐CHP plant could afford wood and Reed canary grass as fuel sources. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

20.
This paper provides a theoretical study of the effects of ambient conditions on the thermodynamic performance of a hybrid combined‐nuclear cycle power plant. The operational parameters investigated are based on the first and second laws of thermodynamics, which include the ambient air temperature and ambient relative humidity (Φ). The results obtained for the gas turbine model are shown to agree very well with operational data from the Al‐Zour Emergency power plant in Kuwait. The ambient temperature was studied within the range of 0–55 °C. The analysis shows that the ambient air temperature has strong effects on plant performance and that operating the system at a high temperature will degrade the performance. Power output is reduced when the temperature is above the standard ambient temperature of 15 °C, and this loss rate is about 17% at 55 °C. The effect of ambient relative humidity (Φ) becomes significant only at higher temperatures. The ambient temperature has a large effect on the exergy destruction of the heat recovery steam generator exhaust, but it has little effect on other components of the plant. The analysis also indicates that reducing the temperature from 55 to 15 °C could help decrease the total exergy destruction of the plant by only 2%. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号