首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The integration of an aqua‐ammonia inlet air‐cooling scheme to a cooled gas turbine‐based combined cycle has been analyzed. The heat energy of the exhaust gas prior to the exit of the heat recovery steam generator has been chosen to power the inlet air‐cooling system. Dual pressure reheat heat recovery steam generator is chosen as the combined cycle configuration. Air film cooling has been adopted as the cooling technique for gas turbine blades. A parametric study of the effect of compressor–pressure ratio, compressor inlet temperature, turbine inlet temperature, ambient relative humidity, and ambient temperature on performance parameters of plants has been carried out. It has been observed that vapor absorption inlet air cooling improves the efficiency of gas turbine by upto 7.48% and specific work by more than 18%, respectively. However, on the adoption of this scheme for combined cycles, the plant efficiency has been observed to be adversely affected, although the addition of absorption inlet air cooling results in an increase in plant output by more than 7%. The optimum value of compressor inlet temperature for maximum specific work output has been observed to be 25 °C for the chosen set of conditions. Further reduction of compressor inlet temperature below this optimum value has been observed to adversely affect plant efficiency. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

2.
A mathematical model based on one‐dimensional energy and mass balance across the solar chimney has been developed. The air flow characteristics such as exit velocity and temperature are evaluated with respect to the collector inclination angle, hourly solar radiation, ambient temperature, and wind speed. The model is validated by comparing the performance parameters obtained, with the experimental results and also with the experimental data of different geometrical range and environmental conditions from the literature. An average deviation of 8% for exit air velocity and 1.35% for exit air temperature is obtained for the solar chimney with absorber inclination angle 30°, collector area 0.41 m2, and chimney height 0.24 m. The experimental daily average and maximum exit air velocity during the month of April are 0.5 and 0.88 m/s, respectively. The predicted optimum operating conditions are 75° inclination angle, 0.63 m2 absorber area, and 0.48‐m chimney height. The maximum average exit air velocity and temperature numerically obtained are 0.64 m/s and 331 K, respectively, when operating with optimum conditions. It is observed that the exit air velocity increases 33% by increasing the absorber area from 0.5 to 3 m2 for a solar chimney with 0.5 m height. An increase in exit air velocity of 52% was obtained by increasing the chimney height from 0.5 to 3 m for a solar chimney with 0.64 m2 absorber area. A reduction in exit air velocity of 4% was observed for the increment in wind flow over the glass cover from 1.5 to 3 m/s. These results confirm that the solar chimney could be designed based on the predicted monthly performance by the present model.  相似文献   

3.
The ambient temperature at Madinah site is between 40 °C and 50 °C during the summer months and sometimes is over 50 °C. The cell temperature reaches the value of 83 °C. This affects the behaviors of solar cells (SC) and decreases their efficiency. The performance of solar cells is presented in this work using thermoelectric module (TEM) as cooling system. In fact, we have found experimentally that the efficiency of solar cells decreases with increase in its temperature. The efficiency of solar cells drops by 0.5% per °C rise in temperature. So, it's necessary to operate them at lower temperature in order to increase their efficiency. Cooling the solar cells would enhance its performance. The hybrid PV/TEM system is proposed for PV applications in hot sites.  相似文献   

4.
This study aims at improving the performance of a waste heat driven adsorption chiller by applying a novel composite adsorbent which is synthesized from activated carbon impregnated by soaking in sodium silicate solution and then in calcium chloride solution. Modeling is performed to analyze the influence of the hot water inlet temperature, cooling water inlet temperature, chilled water inlet temperatures, and adsorption/desorption cycle time on the specific cooling power (SCP) and coefficient of performance (COP) of the chiller system with the composite adsorbent. The simulation calculation indicates a COP value of 0.65 with a driving source temperature of 85 °C in combination with coolant inlet and chilled water inlet temperature of 30 °C and 14 °C, respectively. The most optimum adsorption–desorption cycle time is approximately 360 s based on the performance from COP and SCP. The delivered chilled water temperature is about 9 °C under these operating conditions, achieving a SCP of 380 W/kg.  相似文献   

5.
This paper focuses on evaluation of the optimum cooling water temperature during condensation of saturated water vapor within a shell and tube condenser, through minimization of exergy destruction. First, the relevant exergy destruction is mathematically derived and expressed as a function of operating temperatures and mass flow rates of both vapor and coolant. The optimization problem is defined subject to condensation of the entire vapor mass flow and it is solved based on the sequential quadratic programming (SQP) method. The optimization results are obtained at two different condensation temperatures of 46 °C and 54 °C for an industrial condenser. As the upstream steam mass flow rates increase, the optimal inlet cooling water temperature and exergy efficiency decrease, whereas exergy destruction increases. However, the results are higher for optimum values at a condensation temperature of 54 °C, compared to those when the condensation temperature is 46 °C. For example, when the steam mass flow rate is 1 kg/s and the condensation temperature increases from 46 °C to 54 °C, the optimal upstream coolant temperature increases from 16.78 °C to 25.17 °C. Also, assuming an ambient temperature of 15 °C, the exergy destruction decreases from 172.5 kW to 164.6 kW. A linear dependence of exergy efficiency on dimensionless temperature is described in terms of the ratio of the temperature difference between the inlet cooling water and the environment, to the temperature difference between condensation and environment.  相似文献   

6.
An experimental and numerical model of a solar chimney was proposed in order to predict its performance under varying geometrical features in Iraqi environmental conditions. Steady, two dimensional, turbulent flow was developed by natural convection inside an inclined solar chimney. This flow was investigated numerically at inclination angles 15° to 60°, solar heat flux 150–750 W/m2 and chimney thickness (50, 100 and 150) mm. The experimental study was conducted using a single solar chimney installed on the roof of a single room with a volume of 12 m3. The chimney was 2 m long; 2 m wide has three gap thicknesses namely: 50, 100 and 150 mm. The performance of the solar chimney was evaluated by measuring the temperature of its glass cover, the absorbing wall and the temperature and velocity of induced air. The results of numerical model showed that; the optimum chimney inclination angle was 60° to obtain the maximum rate of ventilation. At this inclination angle, the rate of ventilation was about 20% higher than 45°. Highest rate of ventilation induced with the help of solar energy was found to be 30 air changes per hour in a room of 12 m3 volumes, at a solar radiation of 750 W/m2, inclined surface angle of 60°, aspect ratio of 13.3 and chimney length of 2 m. The maximum air velocity was 0.8 m/s for a radiation intensity of 750 W/m2 at an air gap of 50 mm thickness. No reverse air flow circulation was observed even at the largest gap of 150 mm. The induced air stream by solar chimney can be used for ventilation and cooling in a natural way (passive), without any mechanical assistance.  相似文献   

7.
Intrinsic microcrystalline silicon has been deposited by very high frequency plasma enhanced chemical vapor deposition technique at frequency of 75 MHz. Different gas mixtures of silane and hydrogen were utilized, and the evolution of microstructure and phase in film were studied, while keeping the substrate temperature at 200 °C and the chamber pressure at 0.5 Torr. Optimised material was inserted in p–i–n solar cells: preliminary efficiency of 5.5% was reached for 1 μm-thick solar cells with the Voc around 0.6 V.  相似文献   

8.
In this study, an indirect forced convection solar drying system was tested for drying of palm oil fronds. The drying of 100 kg of palm oil fronds via solar drying system reduced the moisture content from 60% (w.b) to 10% (w.b) in 22 h (3 d of drying). During the drying process, the daily mean values of the drying chamber inlet temperature, drying chamber outlet temperature, drying chamber air temperature, and solar radiation ranged from 26 °C to 75 °C, 25 °C–65 °C, 26 °C–67 °C, and 96 W/m2 to 1042 W/m2 respectively, with corresponding average values of 53 °C, 46 °C, 48 °C, and 580 W/m2. At average solar radiation of about 600 W/m2 and air flow rate 0.13 kg/s, the collector, drying system and pick-up efficiencies were found about 31%, 19% and 67% respectively. The specific moisture extraction rate (SMER) was 0.29 kg/kWh. The exergy efficiency varied between 10% and 73%, with an average of 47%. In addition, the improvement potential of solar drying system for palm oil fronds ranged from 8 W to 455 W, with an average of 172 W.  相似文献   

9.
Solar energy is accessible throughout the year in tropical regions. The latest development of absorption chillers has demonstrated that these systems are suitable for effective use of solar energy. The utilisation of solar energy for heat-driven cooling systems has significant advantages. Without a doubt, solar energy represents a clean energy source that is available without any additional fuel cost, and that can be proportionally accessible when the cooling load increases during the middle hours of the day. This study focuses on a single-double-effect absorption chiller machine that was installed in Indonesia. The system is driven by a dual-heat source that combines gas and solar energy. This system is characterised by simulating its performance in various conditions in terms of the cooling water (28–34 °C) and the hot water (75–90 °C) inlet temperatures. The reference operating condition of this system is 239 kW of cooling capacity. The mathematical model is validated and shows a good agreement with experimental data. In the operative range considered, simulation results yield a coefficient of performance between 1.4 and 3.3, and a gas reduction ratio from 7 to 58% when compared to a double-effect absorption chiller driven by gas. Based on the simulation results, this system is expected to have a good potential for widespread use in tropical Asia regions.  相似文献   

10.
A hybrid solar hot water and Bi2Te3-based thermoelectric generator (TEG) unit using a heat pipe evacuated tube collector with mini-compound parabolic concentrator (mini-CPC) is proposed. In this unit, the heat from the heat pipe evacuated tube solar collector is transferred to the hot side of TEG. Simultaneously, water cooling is used at the cold side to maintain the temperature difference. Electricity is generated by TEG and the remaining heat is transferred to water at the same time. This paper investigates how to convert excess solar heat into electricity more effectively. A mathematical model regarding this unit is developed and validated. It is found that the mini-CPC can significantly improve the electrical efficiency. The optimal thermal conductance of TEG is determined, which could make the best use of excess solar heat. The excess solar heat can be effectively converted into electricity when ZT of Bi2Te3 can be improved from 100 °C to 200 °C. Using TEG with ZT = 1.0 and a geometrical concentrating ratio at 0.92, electrical and thermal efficiencies of this system are predicted to be 3.3% and 48.6% when solar radiation and water temperature are 800 Wm−2 and 20 °C, respectively.  相似文献   

11.
Industry and government interest in solar energy has increased in recent years in the Middle East. However, despite high levels of solar irradiance in the Arabian Gulf, harsh climatic conditions adversely affect the electrical performance of solar photovoltaics (PV). The objective of this study is to compare the annual performance characteristics of solar PV modules that utilize either sun-tracking or water cooling to increase electrical power generation relative to that of stationary, passively cooled modules in the Middle East climatic conditions. This is achieved using an electro-thermal model developed and validated against experimental data acquired in this study. The model is used to predict the annual electrical power output of a 140 W PV module in Abu Dhabi (24.43°N, 54.45°E) under four operating conditions: (i) stationary geographical south facing orientation with passive air cooling, (ii) sun-tracked orientation with passive air cooling, (iii) stationary geographical south facing orientation with water cooling at ambient air temperature, and (iv) stationary geographical south facing orientation with water refrigerated at either 10 °C or 20 °C below ambient air temperature. For water cooled modules, annual electrical power output increases by 22% for water at ambient air temperature, and by 28% and 31% for water refrigerated at 10 °C and 20 °C below ambient air temperature, respectively. 80% of the annual output enhancement obtained using water cooling occurs between the months of May and October. Finally, whereas the annual yield enhancement obtained with water cooling at ambient air temperature from May to October is of 18% relative to stationary passive cooling conditions, sun-tracking over the complete year produces an enhancement of only 15% relative to stationary passive cooling conditions.  相似文献   

12.
To achieve safe, long lifetime, and high‐performance lithium‐ion batteries, a battery thermal management system (BTMS) is indispensable. This is especially required for enabling fast charging‐discharging and in aggressive operating conditions. In this research, a new type of battery cooling system based on thermal silica plates has been designed for prismatic lithium‐ion batteries. Experimental and simulations are combined to investigate the cooling capability of the BTMS associated to different number of cooling channels, flow rates, and flow directions while at different discharge C‐rates. Results show that the maximum temperature reached within the battery decreases as the amount of thermal silica plates and liquid channels increases. The flow direction had no significant influence on the cooling capability. While the performance obviously improves with the increase in inlet flow rate, after a certain threshold, the gain reduces strongly so that it does not anymore justify the higher energy cost. Discharged at 3 C‐rate, an inlet flow rate of 0.1 m/s was sufficient to efficiently cool down the system; discharged at 5 C‐rate, the optimum inlet flow rate was 0.25 m/s. Simulations could accurately reproduce experimental results, allowing for an efficient design of the liquid‐cooled BTMS.  相似文献   

13.
The objective of this paper is to study the benefits of application of solar chimney on the south roof and cool metal ceiling on the north roof through the experiment in a detached building called a controlled cell, and the related numerical model constructed from a computational fluid dynamics (CFD) program. The experimental results are used for calculation of values of heat transfer coefficient of the cool ceiling and evaluation of the mean cooling potential of the combined passive cooling system. The two-dimensional numerical models generated by the CFD program use the mean values of wall temperatures in the application of solar chimney in the controlled cell as the boundary conditions. The effects of cool ceiling on the temperature, velocity and airflow rate in the controlled cell are investigated through the numerical model in which the north ceiling temperature is reduced by 2–4 °C from the measured value of 32.8 °C. The mean cooling potential of the application of combined system is found to be two times higher than the application of the solar chimney. Good agreements between the predicted and experimental results are obtained from the comparison of temperature and volume flow rate at the middle section of the controlled cell. The reduction of north ceiling temperature in the free-convection numerical model shows the decrease of air temperature in the upper region of the room by 0.5–0.7 °C from the original value of 33.3 °C, and the increase of volume flow rate by 12%.  相似文献   

14.
The film cooling performance of chevron holes with different inclination angles and exit lateral diffusion angles has been studied experimentally and numerically. The inclination angles include 35° and 55°. The exit lateral diffusion angles include 20° and 25°. The film cooling effectiveness, heat transfer coefficient and discharge coefficient were measured on a flat plate model by transient liquid crystal measurement technique under four blowing ratios. The results show that the large inclination angle reduces the film cooling effectiveness. The influence of diffusion angle has two aspects: the large diffusion angle leads to mainstream ingestion and decreases film cooling effectiveness at M=1.0 and 1.5; however, the large diffusion angle increases the film cooling effectiveness at high blowing ratio of 2.0, because the larger hole exit area decreases the normal momentum component of the film jet. The large inclination angle decreases the heat transfer coefficient in the right downstream region at M=0.5 and 1.0. The large diffusion angle enhances the heat transfer in the right downstream of the holes in M=0.5~1.5 conditions. The chevron hole with large inclination angle generally has the highest discharge coefficient.  相似文献   

15.
The common solar water heater system can meet low temperature requirements, but exhibits very low efficiency in attaining higher water temperatures (55–95 °C). In the current paper, a compound parabolic concentrator (CPC)-type solar water heater system experiment rig with a U-pipe was set up, and its performance in meeting higher temperature requirements was investigated. The experiments were conducted in December at Hefei (31°53′ N, 117°15′ E), in the eastern region of China. The system showed steady performance in winter, with overall thermal efficiency always above 43%. The water in the tank was heated from 26.9 °C to 55, 65, 75, 85, and 95 °C. Through the experimental study and exergetic analysis of the solar water heater system, results of the five experiments showed thermal efficiency of above 49.0% (attaining 95 °C water temperature) and exergetic efficiency of above 4.62% (attaining 55 °C water temperature). Based on these results, the CPC-type solar water heater system with a U-pipe shows superior thermal performance in attaining higher temperatures and has potential applications in space heating, heat-powered cooling, seawater desalination, industrial heating, and so on.  相似文献   

16.
An experimental investigation was performed to study the heat transfer in an eight-nozzle spray cooling system with de-ionized water as the working fluid. Visualization of the liquid-solid contact area and the flow near the heated surface was made using a microscopic lens system in conjunction with an advanced high-speed camera. The film thickness and film wavelike characteristics under liquid volume flow rates ranged from 2.78×10 -6 m 3 /s to 1.39×10 -5 m 3 /s and surface temperatures between 22℃ and 78.2℃ were examined respectively. The development process of the liquid film on the heated surface was observed. The local mean film thickness, the film wavelike characteristics and the behavior of the bubbles appeared in the liquid film were captured using an image processing technique. It is discovered that there exists a climax of local mean film thickness during the starting process of spray cooling. When the liquid film reaches the dynamic stable state, the dimensionless mean film thickness decreases with the increase of the liquid volume flow rate, and increases with the increase of surface temperature generally. Besides, the volume flow rate has a more significant impact on the wavelength and amplitude of the liquid film compared to the surface temperature.  相似文献   

17.
The deficiency in the energy for the space cooling is overcome by solar energy. Still the input energy is minimized by integrating both power and cooling cycle in common platform, such as working fluid, component and working parameters. The aqua-ammonia is used in both power cycle and vapor cooling cycle. The generator is common for cycles for the production of ammonia vapor. The analyses are made to find out the operational parameters for the cooling cogeneration cycle with solar as source. The analyses are done for the proposed cycle with various atmosphere temperatures. At absorber concentration of 0.42 and turbine inlet concentration of 0.90, with solar collector exit temperature of 155°C and atmosphere temperature of 30°C the generated power and cooling are 21.88 and 215.79 kW, respectively. The power and cooling output range can alter by varying turbine inlet concentration and temperature.  相似文献   

18.
A simulation study of hybrid solar-geothermal heat pump system for residential applications using carbon dioxide was carried out under different operating conditions. The system consists of a solar unit (concentric evacuated tube solar collector and heat storage tank) and a CO2 heat pump unit (three double-pipe heat exchangers, electric expansion valve, and compressor). As a result, the differential of pressure ratio between the inlet and the outlet of the compressor increases by 19.9%, and the compressor work increases from 4.5 to 5.3 kW when the operating temperature of the heat pump rises from 40 °C to 48 °C. Besides, the pressure ratio of the compressor decreases from 3 to 2.5 when the ground temperature increases from 11 °C to 19 °C. The operating time of the heat pump is reduced by 5 h as the daily solar radiation increases. As the solar radiation increases from 1 to 20 MJ/m2, the collector heat rises by 48% and the maximum collector heat becomes 47.8 kWh. The heating load increases by 70% as the indoor design temperature increases from 18 °C to 26 °C. However, the solar fraction is reduced from 11.4% to 5.8% because of the increases of the heating load.  相似文献   

19.
Effects of inlet conditions on film evaporation along an inclined plate   总被引:1,自引:0,他引:1  
The evaporation of falling water liquid film in air flow is used in different solar energy applications as drying, distillation and desalination, and desiccant systems. The good understanding of the hydrodynamics and heat exchange in falling liquid film and gas flow, with interfacial heat and mass transfer, can be applied in improving solar systems performance. The solar system performance is dependent on the operating conditions, system conception and related to several physical parameters, where the effects of some of these parameters are not completely clarified. In the present numerical study, we examine the effects of inlet conditions on the evaporation processes along the gas–liquid interface. The liquid film streams over an inclined plate subjected to different thermal conditions. Liquid and gas flows are approached by two coupled laminar boundary-layers. The numerical solution is obtained by utilizing an implicit finite-difference box method. In this analysis an air–water system is considered and the coupled effects of inclination, inlet liquid mass flow rate and gas velocity are examined. The results show that, for imposed heat flux or uniform wall temperature, the effect of inclination is highly dependent on the liquid mass flow rate and gas velocity. An increase in the liquid mass flow rate causes an enhancement of the effect of inclination on the heat and mass transfer. The inclination affects the heat and mass transfer, especially at lower gas velocities. In the range of inclination angles of 0–10°, an increase in the inclination improves the evaporation by increasing the vapor mass flow rate. The maximum effect of inclination is nearly achieved at an inclination angle of 10°.  相似文献   

20.
An innovative steam reformer for hydrogen production at temperatures lower than 550 °C has been developed in the EU project CoMETHy (Compact Multifuel-Energy To Hydrogen converter). The steam reforming process has been specifically tailored and re-designed to be combined with Concentrating Solar plants using “solar salts”: a low-temperature steam reforming reactor was developed, operating at temperatures up to 550 °C, much lower than the traditional process (usually > 850 °C). This result was obtained after extensive research, going from the development of basic components (catalysts and membranes) to their integration in an innovative membrane reformer heated with molten salts, where both hydrogen production and purification occur in a single stage. The reduction of process temperatures is achieved by applying advanced catalyst systems and hydrogen selective Pd-based membranes. Process heat is supplied by using a low-cost and environmentally friendly binary NaNO3/KNO3 liquid mixture (60/40 w/w) as heat transfer fluid; such mixture is commonly used for the same purpose in the concentrating solar industry, so that the process can easily be coupled with concentrating solar power (CSP) plants for the supply of renewable process heat. This paper deals with the successful operation and validation of a pilot scale reactor with a nominal capacity of 2 Nm3/h of pure hydrogen from methane. The plant was operated with molten salt circulation for about 700 h, while continuous operation of the reactor was achieved for about 150 h with several switches of operating conditions such as molten salts inlet temperature, sweep steam flow rate and steam-to-carbon feed ratio. The results obtained show that the membrane reformer allows to achieve twice as high a conversion compared to a conventional reformer operating at thermodynamic equilibrium under the same conditions considered in this paper. A highly pure hydrogen permeate stream was obtained (>99.8%), while the outlet retentate stream had low CO concentration (<2%). No macroscopic signs of reactor performance loss were observed over the experimental operation period.  相似文献   