首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 740 毫秒
1.
Qu Y  Xia S  Yuan H  Wu Q  Li M  Zou L  Zhang L  Liang Z  Zhang Y 《Analytical chemistry》2011,83(19):7457-7463
An integrated sample pretreatment system, composed of a click maltose hydrophilic interaction chromatography (HILIC) column, a strong cation exchange (SCX) precolumn, and a PNGase F immobilized enzymatic reactor (IMER), was established for the simultaneous glycopeptide enrichment, sample buffer exchange, and online deglycosylation, by which the sample pretreatment for glycoproteome could be performed online automatically, beneficial to improve the efficiency and sensitivity of the N-linked glycosylation site identification. With such a system, the deglycosylated glycopeptide from the digests of avidin with the coexistence of 50 times (mass ratio) BSA could be selectively detected, and the detection limit as low as 5 fmol was achieved. Moreover, the sample pretreatment time was significantly shortened to ~1 h. Such a system was further successfully applied for analyzing the digest of the soluble fraction extracted from rat brain. A total of 120 unique glycoprotein groups and 196 N-linked glycosylation sites were identified by nanoreversed phase liquid chromatography-electrospray ionization-tandem mass spectrometry (nanoRPLC-ESI-MS/MS), with the injected digests amount as 6 μg. All these results demonstrate that the integrated system is of great promise for N-linked glycosylation site profiling and could be further online coupled with nanoHPLC-ESI-MS/MS to achieve high-throughput glycoproteome analysis.  相似文献   

2.
Due to its strong ultraviolet absorption, high salt tolerance, and little interference in the low molecular weight region, N-(1-naphthyl) ethylenediamine dihydrochloride (NEDC) has been applied as a matrix to measure the level of glucose in rat brain microdialysates by matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS) in combination with in vivo microdialysis. By monitoring the ion signals of (glucose + Cl)(-) in the mass spectra, we achieved a low detection limit of ~10 μM for glucose in 126 mM NaCl, which is a typical component in artificial cerebrospinal fluid, without prior sample purification. It is concluded that NEDC-assisted laser desorption/ionization (LDI) MS is a fast and general method for sensitive detection of small molecules (such as glucose and amino acids) in high ionic strength solutions.  相似文献   

3.
He Q  Zhu Z  Hu S  Zheng H  Jin L 《Analytical chemistry》2012,84(9):4179-4184
In this study, a new liquid-film dielectric barrier discharge (LFDBD) atomic emission source was developed for microsample elemental determination. It consists of a copper electrode, a tungsten wire electrode, and a piece of glass slide between them, which serves as the dielectric barrier as well as the sample plate. The sample solution with 1 mol L(-1) nitric acid, when deposited onto the surface of the glass slide, forms a thin liquid film. The plasma is generated between the tip of the tungsten wire electrode and the liquid film surface when alternating-current (ac) high voltage (peak voltage ~3.7 kV, frequency ~30 kHz) is applied on the electrodes. Qualitative and quantitative determinations of metal ions in the sample solution were achieved by atomic emission measurements in the plasma and were demonstrated in this study with elements Na, K, Cu, Zn, and Cd. Detection limits were in the range from 0.6 ng (7 μg L(-1)) for Na to 6 ng (79 μg L(-1)) for Zn. Repeatability, expressed as relative standard deviation from seven repetitive analyses of samples with analyte concentrations at 1 mg L(-1), varied from 2.1% to 4.4%. Compared with other liquid discharge systems that operate at atmospheric pressure, the current system offers several advantages: First, it eliminates the use of a sample flow system (e.g., syringe or peristaltic pump); instead, a small aliquot of sample is directly pipetted onto the glass slide for analysis. Second, it is a microanalysis system and requires sample volume ≤80 μL, a benefit when a limited amount of sample is available. Third, because the sample is applied in aliquot, there is no washout time, and the analysis can be easily extended to sample array for high-throughput analysis. The proposed LFDBD is promising for in-field elemental determination because of its simplicity, cost effectiveness, low power supply, and no inert gas requirement.  相似文献   

4.
Inlet ionization is a new approach for ionizing both small and large molecules in solids or liquid solvents with high sensitivity. The utility of solvent based inlet ionization mass spectrometry (MS) as a method for analysis of volatile and nonvolatile compounds eluting from a liquid chromatography (LC) column is demonstrated. This new LC/MS approach uses reverse phase solvent systems common to electrospray ionization MS. The first LC/MS analyses using this novel approach produced sharp chromatographic peaks and good quality full mass range mass spectra for over 25 peptides from injection of only 1 pmol of a tryptic digest of bovine serum albumin using an eluent flow rate of 55 μL min(-1). Similarly, full acquisition LC/MS/MS of the MH(+) ion of the drug clozapine, using the same solvent flow rate, produced a signal-to-noise ratio of 54 for the major fragment ion with injection of only 1 μL of a 2 ppb solution. LC/MS results were acquired on two different manufacturer's mass spectrometers using a Waters Corporation NanoAcquity liquid chromatograph.  相似文献   

5.
Effective electrokinetic field-amplified sample injection occurring at the capillary inlet from a sample volume equivalent exceeding that of the capillary up to 10-fold is described and demonstrated to provide over 1000-fold sensitivity enhancement. Successful application of this head-column field-amplified sample stacking approach to the analysis of positively chargeable, hydrophobic compounds in binary system capillary electrophoresis is shown to require an initially introduced low-conductivity zone (water plug) of >1 mm length, a sample injection voltage <20 kV, and an injection time interval <60 s. Following these conditions for more than 1500 runs with capillaries of 50 μm i.d. and about 20 cm effective length, damaging heat production during electroinjection within the low-conductivity zone at the column inlet (boiling of solvent and possible deposition of solutes or fusing of capillary walls) could be prevented. The solute amount injected by head-column field-amplified sample stacking is further shown to be dependent on the organic fraction and the buffer in the sample solution. High content of organic solvent, low conductivity, and the presence of a small amount of H(+) (50-100 μM) provides the highest sensitivity for analysis of positively chargeable model substances, including amiodarone and desethylamiodarone. Solutes present at the nanomolar level can thereby be accumulated from a sample volume equivalent of about 4 μL (with injection of about 20 nL of sample solvent into the capillary) and measured by UV absorption detection. To prevent disturbances caused by electrolysis, sample vials should be employed only once. The data obtained further show that quantitation can be reliably performed using internal calibration based on peak height (RSDs for inter- and intraday determinations are on the 2% level). However, due to variation of the roughness of the capillary walls and cuts, the time interval between operational steps, and trace adsorption onto the capillary walls, the length of the water zone drawn by capillary action on the inlet side is not constant, and external calibration therefore cannot be employed for quantitation.  相似文献   

6.
The combination of electrochemistry (EC) and mass spectrometry (MS) is a powerful analytical tool for studying mechanisms of redox reactions, identification of products and intermediates, and online derivatization/recognition of analytes. This work reports a new coupling interface for EC/MS by employing nanospray desorption electrospray ionization, a recently developed ambient ionization method. We demonstrate online coupling of nanospray desorption electrospray ionization MS with a traditional electrochemical flow cell, in which the electrolyzed solution emanating from the cell is ionized by nanospray desorption electrospray ionization for MS analysis. Furthermore, we show first coupling of nanospray desorption electrospray ionization MS with an interdigitated array (IDA) electrode enabling chemical analysis of electrolyzed samples directly from electrode surfaces. Because of its inherent sensitivity, nanospray desorption electrospray ionization enables chemical analysis of small volumes and concentrations of sample solution. Specifically, good-quality signal of dopamine and its oxidized form, dopamine o-quinone, was obtained using 10 μL of 1 μM solution of dopamine on the IDA. Oxidation of dopamine, reduction of benzodiazepines, and electrochemical derivatization of thiol groups were used to demonstrate the performance of the technique. Our results show the potential of nanospray desorption electrospray ionization as a novel interface for electrochemical mass spectrometry research.  相似文献   

7.
A simple, sensitive optical analyzer for the rapid determination of cyanide in blood in point of care applications is described. HCN is liberated by the addition of 20% H(3)PO(4) and is absorbed by a paper filter impregnated with borate-buffered (pH 9.0) hydroxoaquocobinamide (hereinafter called cobinamide). Cobinamide on the filter changes color from orange (λ(max) = 510 nm) to violet (λ(max) = 583 nm) upon reaction with cyanide. This color change is monitored in the transmission mode by a light emitting diode (LED) with a 583 nm emission maximum and a photodiode detector. The observed rate of color change increases 10 times when the cobinamide solution for filter impregnation is prepared in borate-buffer rather than in water. The use of a second LED emitting at 653 nm and alternate pulsing of the LEDs improves the limit of detection by 4 times to ~0.5 μM for a 1 mL blood sample. Blood cyanide levels of imminent concern (≥10 μM) can be accurately measured in ~2 min. The response is proportional to the mass of cyanide in the sample: smaller sample volumes can be successfully used with proportionate change in the concentration LODs. Bubbling air through the blood-acid mixture was found effective for mixing of the acid with the sample and the liberation of HCN. A small amount of ethanol added to the top of the blood was found to be the most effective means to prevent frothing during aeration. The relative standard deviation (RSD) for repetitive determination of blood samples containing 9 μM CN was 1.09% (n = 5). The technique was compared blind with a standard microdiffusion-spectrophotometric method used for the determination of cyanide in rabbit blood. The results showed good correlation (slope 1.05, r(2) 0.9257); independent calibration standards were used.  相似文献   

8.
A new capillary electrophoresis mass spectrometry (CE-MS) technique is introduced for age estimation of silk textiles based on amino acid racemization rates. With an L to D conversion half-life of ~2500 years for silk (B. mori) aspartic acid, the technique is capable of dating silk textiles ranging in age from several decades to a few-thousand-years-old. Analysis required only ~100 μg or less of silk fiber. Except for a 2 h acid hydrolysis at 110 °C, no other sample preparation is required. The CE-MS analysis takes ~20 min, consumes only nanoliters of the amino acid mixture, and provides both amino acid composition profiles and D/L ratios for ~11 amino acids.  相似文献   

9.
Akin to optical beam chopping, we demonstrate that formation and routing of aqueous droplets in oil can chop a fluidic sample to permit phase sensitive detection. This hand-operated microfluidic sample chopper (μChopper) greatly reduces the detection limit of molecular absorbance in a 27 μm optical path. With direct dependence on path length, absorbance is fundamentally incompatible with microfluidics. While other microfluidic absorbance approaches use complex additions to fabrication, such as fiber coupling and increased optical paths, this self-regulated μChopper uses opposing droplet generators to passively alternate sample and reference droplets at ~10 Hz each. Each droplet's identity is automatically locked-in to its generator, allowing downstream lock-in analysis to nearly eliminate large signal drift or 1/f noise. With a lock-in time constant of 1.9 s and total interrogated volume of 59 nL (122 droplets), a detection limit of 3.0 × 10(-4) absorbance units or 500 nM bromophenol blue (BPB) (29 fmol) was achieved using only an optical microscope and a standard, single-depth (27 μm) microfluidic device. The system was further applied to nanoliter pH sensing and validated with a spectrophotometer. The μChopper represents a fluidic analog to an optical beam chopper, and the self-regulated sample/reference droplet alternation promotes ease of use.  相似文献   

10.
Site-specific analysis of protein glycosylation is important for biochemical and clinical research efforts. Glycopeptide analysis using liquid chromatography-collision-induced dissociation/electron transfer dissociation mass spectrometry (LC-CID/ETD-MS) allows simultaneous characterization of the glycan structure and attached peptide site. However, due to the low ionization efficiency of glycopeptides during electrospray ionization, 200-500 fmol of sample per injection is needed for a single LC-MS run, which makes it challenging for the analysis of limited amounts of glycoprotein purified from biological matrixes. To improve the sensitivity of LC-MS analysis for glycopeptides, an ultranarrow porous layer open tubular (PLOT) LC column (2.5 m × 10 μm i.d.) was coupled to a linear ion trap (LTQ) collision-induced dissociation/electron transfer dissociation mass spectrometer to provide sensitive analysis of N-linked protein glycosylation heterogeneity. The potential of the developed method is demonstrated by the characterization of site-specific glycosylation using haptoglobin (Hpt) as a model protein. To limit the amount of haptoglobin to low picomole amounts of protein, we affinity purified it from 1 μL of pooled lung cancer patient plasma. A total of 26 glycoforms/glycan compositions on three Hpt tryptic glycopeptides were identified and quantified from 10 LC-MS runs with a consumption of 100 fmol of Hpt digest (13 ng of protein, 10 fmol per injection). Included in this analysis was the determination of the glycan occupancy level. At this sample consumption level, the high sensitivity of the PLOT LC-LTQ-CID/ETD-MS system allowed glycopeptide identification and structure determination, along with relative quantitation of glycans presented on the same peptide backbone, even for low abundant glycopeptides at the ~100 amol level. The PLOT LC-MS system is shown to have sufficient sensitivity to allow characterization of site-specific protein glycosylation from trace levels of glycosylated proteins.  相似文献   

11.
Cui L  Zou Y  Lin N  Zhu Z  Jenkins G  Yang CJ 《Analytical chemistry》2012,84(13):5535-5541
Fluorescence anisotropy (FA) is a reliable and excellent choice for fluorescence sensing. One of the key factors influencing the FA value for any molecule is the molar mass of the molecule being measured. As a result, the FA method with functional nucleic acid aptamers has been limited to macromolecules such as proteins and is generally not applicable for the analysis of small molecules because their molecular masses are relatively too small to produce observable FA value changes. We report here a molecular mass amplifying strategy to construct anisotropy aptamer probes for small molecules. The probe is designed in such a way that only when a target molecule binds to the probe does it activate its binding ability to an anisotropy amplifier (a high molecular mass molecule such as protein), thus significantly increasing the molecular mass and FA value of the probe/target complex. Specifically, a mass amplifying probe (MAP) consists of a targeting aptamer domain against a target molecule and molecular mass amplifying aptamer domain for the amplifier protein. The probe is initially rendered inactive by a small blocking strand partially complementary to both target aptamer and amplifier protein aptamer so that the mass amplifying aptamer domain would not bind to the amplifier protein unless the probe has been activated by the target. In this way, we prepared two probes that constitute a target (ATP and cocaine respectively) aptamer, a thrombin (as the mass amplifier) aptamer, and a fluorophore. Both probes worked well against their corresponding small molecule targets, and the detection limits for ATP and cocaine were 0.5 μM and 0.8 μM, respectively. More importantly, because FA is less affected by environmental interferences, ATP in cell media and cocaine in urine were directly detected without any tedious sample pretreatment. Our results established that our molecular mass amplifying strategy can be used to design aptamer probes for rapid, sensitive, and selective detection of small molecules by means of FA in complex biological samples.  相似文献   

12.
Chen CH  Cho SH  Chiang HI  Tsai F  Zhang K  Lo YH 《Analytical chemistry》2011,83(19):7269-7275
When attempting to probe the genetic makeup of diverse bacterial communities that elude cell culturing, researchers face two primary challenges: isolation of rare bacteria from microbial samples and removal of contaminating cell-free DNA. We report a compact, low-cost, and high-performance microfabricated fluorescence-activated cell sorting (μFACS) technology in combination with a tyramide signal amplification fluorescence in situ hybridization (TSA-FISH) to address these two challenges. The TSA-FISH protocol that was adapted for flow cytometry yields a 10-30-fold enhancement in fluorescence intensity over standard FISH methods. The μFACS technology, capable of enhancing its sensitivity by ~18 dB through signal processing, was able to enrich TSA-FISH-labeled E. coli cells by 223-fold. The μFACS technology was also used to remove contaminating cell-free DNA. After two rounds of sorting on E. coli mixed with λ-phage DNA (10 ng/μL), we demonstrated over 100,000-fold reduction in λ-DNA concentration. The integrated μFACS and TSA-FISH technologies provide a highly effective and low-cost solution for research on the genomic complexity of bacteria as well as single-cell genomic analysis of other sample types.  相似文献   

13.
A laser ablation microanalysis system has been developed that can analyze trace elements with a sensitivity in the ppb range, using a CETAC LSX-200 laser ablation system with a Finnigan Element. This capability has been applied to a set of iron meteorites to demonstrate the laser microprobe's analytical capability for the determination of platinum group elements (PGEs) with a spatial resolution of ~20 μm, comparable to that of dynamic secondary ion mass spectrometry (SIMS). The laser is shown to provide an accurate means of solid sampling for magnetic sector inductively coupled plasma mass spectrometry (ICPMS), allowing the determination of bulk metal composition, chemical zoning within the sample, and depth profiling. Recovery of the chemical zoning in taenite lamellae was achieved for Ru, Rh, and Pd, which was not previously possible using SIMS. The methods presented here show that magnetic sector ICPMS can be successfully coupled to a laser ablation system, providing the advantages of higher sensitivity of the sector instrument, low background count rates (<0.1 counts/s), and flat-topped spectral peaks, while minimizing tradeoff against the speed of data acquisition required to handle the transient signals from the laser ablation system.  相似文献   

14.
Electrokinetic supercharging (EKS) is a powerful and practical method for multifold in-line concentration of various analytes prior to capillary electrophoresis (CE) analysis. However, a problem of insufficient sensitivity has always existed when trace analyte quantification by EKS-CE is a target, especially when coupled with conventional detectors. Normally this requires a greatly increased amount of analyte injected without separation degradation. In this contribution, we have shown that it is possible to substantially improve analyte loading and hence CE method detectability by modifying sample introduction configuration. The volume of sample vial was increased (from typical 500 μL to 17 mL), the common wire electrode was replaced by a ring electrode, and the sample solution was stirred. With these alterations, more analyte ions are accumulated within the effective electric field during electrokinetic injection and then maintained as focused zones due to transient isotachophoresis. The versatility of the customized EKS-CE approach for sample concentration was demonstrated for a mixture of seven rare-earth metal ions with an enrichment factor of 500?000 giving detection limits at or below 1 ng/L. These detection limits are over 100?000 times better than can be achieved by normal hydrodynamic injection, 1000 times better than the sensitivity thresholds of inductively coupled plasma atomic emission spectrometry (ICP-AES), and even close to those of inductively coupled plasma mass spectrometry (ICPMS).  相似文献   

15.
A tunable lead-salt diode laser and a multipass optical cell are used to detect traces of tritiated water vapour in air. The present system has a sensitivity of ∼ 700 μCi/m3 if the air sample directly enters the cell, and an enhanced sensitivity of 35 μCi/m3 if the water vapour is precondensed from the air sample. The instrument is free from interference from HT or other radioactive species which may be present in the sample.  相似文献   

16.
A new transducer concept in bioanalysis and biosensors, utilizing measurements of magnetic permeability, is reported. A model system based on dextran ferrofluid, concanavalin A immobilized to a carrier (Sepharose), and glucose was used to demonstrate the feasibility of this approach. Direct ferromagnetic detection of the dextran ferrofluid was achieved by using a measuring coil (transducer) in a Maxwell bridge. A sensitivity of 21 μV/(μg Fe/mL) and a rsd value of 3.8% were obtained (n = 5). It was also demonstrated that a small, non-ferromagnetic metabolite (glucose) could be detected using a competitive approach. With an increasing concentration of glucose (20-40 mM), we observed a decrease in the response (0.59-0.11 mV). Reference measurements performed on Sepharose without the biorecognition element, concanavalin A, showed no significant response (0.01 mV). Some potential advantages and drawbacks of this novel type of magnetic transducer are discussed. The advantages include very low interference from the sample matrix, as the transducer is only sensitive to ferromagnetic substances, which rarely are present in samples. In addition, it is suggested that these transducers should be free from fouling. The new transducers are proposed to provide the basis for a new group of affinity biosensors suitable for in vivo and in vitro use.  相似文献   

17.
In this paper we introduce laser ablation atmospheric pressure photoionization (LAAPPI), a novel atmospheric pressure ion source for mass spectrometry. In LAAPPI the analytes are ablated from water-rich solid samples or from aqueous solutions with an infrared (IR) laser running at 2.94 μm wavelength. Approximately 12 mm above the sample surface, the ablation plume is intercepted with an orthogonal hot solvent (e.g., toluene or anisole) jet, which is generated by a heated nebulizer microchip and directed toward the mass spectrometer inlet. The ablated analytes are desolvated and ionized in the gas-phase by atmospheric pressure photoionization using a 10 eV vacuum ultraviolet krypton discharge lamp. The effect of operational parameters and spray solvent on the performance of LAAPPI is studied. LAAPPI offers ~300 μm lateral resolution comparable to, e.g., matrix-assisted laser desorption ionization. In addition to polar compounds, LAAPPI efficiently ionizes neutral and nonpolar compounds. The bioanalytical application of the method is demonstrated by the direct LAAPPI analysis of rat brain tissue sections and sour orange (Citrus aurantium) leaves.  相似文献   

18.
Two continuous-wave (CW) focused CO(2) Doppler lidars (9.1 and 10.6 μm) were developed for airborne in situ aerosol backscatter measurements. The complex path of reliably calibrating these systems, with different signal processors, for accurate derivation of atmospheric backscatter coefficients is documented. Lidar calibration for absolute backscatter measurement for both lidars is based on range response over the lidar sample volume, not solely at focus. Both lidars were calibrated with a new technique using well-characterized aerosols as radiometric standard targets and related to conventional hard-target calibration. A digital signal processor (DSP), a surface acoustic wave spectrum analyzer, and manually tuned spectrum analyzer signal analyzers were used. The DSP signals were analyzed with an innovative method of correcting for systematic noise fluctuation; the noise statistics exhibit the chi-square distribution predicted by theory. System parametric studies and detailed calibration improved the accuracy of conversion from the measured signal-to-noise ratio to absolute backscatter. The minimum backscatter sensitivity is ~3 × 10(-12) m(-1) sr(-1) at 9.1 μm and ~9 × 10(-12) m(-1) sr(-1) at 10.6 μm. Sample measurements are shown for a flight over the remote Pacific Ocean in 1990 as part of the NASA Global Backscatter Experiment (GLOBE) survey missions, the first time to our knowledge that 9.1-10.6-μm lidar intercomparisons were made. Measurements at 9.1 μm, a potential wavelength for space-based lidar remote-sensing applications, are to our knowledge the first based on the rare isotope (12)C (18)O(2) gas.  相似文献   

19.
We have developed a new calibration technique for multielement determination and U-Pb dating of zircon samples using laser ablation-inductively coupled plasma mass spectrometry (ICPMS) coupled with galvanometric optics. With the galvanometric optics, laser ablation of two or more sample materials could be achieved in very short time intervals (~10 ms). The resulting sample aerosols released from different ablation pits or different solid samples were mixed and homogenized within the sample cell and then transported into the ICP ion source. Multiple spot laser ablation enables spiking of analytes or internal standard elements directly into the solid samples, and therefore the standard addition calibration method can be applied for the determination of trace elements in solid samples. In this study, we have measured the rare earth element (REE) abundances of two zircon samples (Nancy 91500 and Pre?ovice) based on the standard addition technique, using a direct spiking of analytes through a multispot laser ablation of the glass standard material (NIST SRM612). The resulting REE abundance data show good agreement with previously reported values within analytical uncertainties achieved in this study (10% for most elements). Our experiments demonstrated that nonspectroscopic interferences on 14 REEs could be significantly reduced by the standard addition technique employed here. Another advantage of galvanometric devices is the accumulation of sample aerosol released from multiple spots. In this study we have measured the U-Pb age of a zircon sample (LMR) using an accumulation of sample aerosols released from 10 separate ablation pits of low diameters (~8 μm). The resulting (238)U-(206)Pb age data for the LMR zircons was 369 ± 64 Ma, which is in good agreement with previously reported age data (367.6 ± 1.5 Ma). (1) The data obtained here clearly demonstrate that the multiple spot laser ablation-ICPMS technique can become a powerful approach for elemental and isotopic ratio measurements in solid materials.  相似文献   

20.
Electrochemical impedance spectroscopy (EIS) is used to detect 2,4,6-trinitrotoluene (TNT) in a novel sandwiched structure which relies on the specific interactions between (i) primary amine with TNT and (ii) TNT and anti-TNT aptamer. With pure targets, the assay has a sensitivity of 10(-14) M, a dynamic range of 10(-14)-10(-3) M, and employs a small sample volume (25 μL). The method's sensitivity is comparable to state of the art optical methods with the added advantages of electrochemical detection, which can be easily miniaturized and implemented into a hand-held device.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号