首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A new technique to generate macromodels of tree structured interconnects including the effect of inductances and frequency dependent per unit length parameters is presented. The proposed method allows the derivation of the exact transfer function of an interconnect tree with distributed RLC models. It presents some advantages over other techniques: first, it enables to easily incorporate frequency dependent phenomena such as skin effect and dielectric losses in a macromodel of the entire interconnect tree; second, a model order reduction can be efficiently performed at the level of each single interconnect, thus leading to a reduced-order model of the entire interconnect; third, the knowledge of all the poles of the tree is made possible by solving low-order algebraic equations at a reduced computational cost. The examples confirm that the proposed method is able to capture the physics of the interconnect trees, being accurate and efficient at the same time  相似文献   

2.
Biliary tree structures are embedded in adipose tissue and, therefore, cannot be visualized directly by the surgeon during cholecystectomy operations. This can lead to inadvertent injuries with serious complications for the patient. Computational studies were performed to assess the feasibility of noninvasively localizing these structures from spectrally resolved near-infrared reflectance measurements. Methodologies were developed for vessel localization, both on the adipose tissue surface and depthwise, by use of semi-infinite and two-layer models of diffuse photon propagation in tissues, respectively. The simulation results, along with some preliminary experimental measurements on tissue-simulating phantoms, prove the feasibility of these methods and show promise for their future clinical application.  相似文献   

3.
We tested the feasibility of using adaptive imaging, namely phase-aberration correction, with two-dimensional (2-D) arrays and real-time, 3-D ultrasound. Because of the high spatial frequency content of aberrators, 2-D arrays, which generally have smaller pitch and thus higher spatial sampling frequency, and 3-D imaging show potential to improve the performance of adaptive imaging. Phase-correction algorithms improve image quality by compensating for tissue-induced errors in beamforming. Using the illustrative example of transcranial ultrasound, we have evaluated our ability to perform adaptive imaging with a real-time, 3-D scanner. We have used a polymer casting of a human temporal bone, root-mean-square (RMS) phase variation of 45.0 ns, full-width-half-maximum (FWHM) correlation length of 3.35 mm, and an electronic aberrator, 100 ns RMS, 3.76 mm correlation, with tissue phantoms as illustrative examples of near-field, phase-screen aberrators. Using the multilag, least-squares, cross-correlation method, we have shown the ability of 3-D adaptive imaging to increase anechoic cyst identification, image brightness, contrast-to-speckle ratio (CSR), and, in 3-D color Doppler experiments, the ability to visualize flow. For a physical aberrator skull casting we saw CSR increase by 13% from 1.01 to 1.14, while the number of detectable cysts increased from 4.3 to 7.7.  相似文献   

4.
Laparoscopic ultrasound has seen increased use as a surgical aide in general, gynecological, and urological procedures. The application of real-time, three-dimensional (RT3D) ultrasound to these laparoscopic procedures may increase information available to the surgeon and serve as an additional intraoperative guidance tool. The integration of RT3D with recent advances in robotic surgery also can increase automation and ease of use. In this study, a 1-cm diameter probe for RT3D has been used laparoscopically for in vivo imaging of a canine. The probe, which operates at 5 MHz, was used to image the spleen, liver, and gall bladder as well as to guide surgical instruments. Furthermore, the three-dimensional (3-D) measurement system of the volumetric scanner used with this probe was tested as a guidance mechanism for a robotic linear motion system in order to simulate the feasibility of RT3D/robotic surgery integration. Using images acquired with the 3-D laparoscopic ultrasound device, coordinates were acquired by the scanner and used to direct a robotically controlled needle toward desired in vitro targets as well as targets in a post-mortem canine. The rms error for these measurements was 1.34 mm using optical alignment and 0.76 mm using ultrasound alignment.  相似文献   

5.
Fatty liver (steatosis) occurs in obese patients, among others, and is related to the development of diabetes type-2. Timely diagnosis of steatosis is therefore of great importance. Steatosis is also the most common liver disease of high-yielding dairy cattle during early lactation. This makes it a suitable animal model for studying liver steatosis. Furthermore, reference of derived ultrasound parameters against a "gold standard" is possible in cattle by taking a liver biopsy for the assessment of fat concentration. The authors undertook this pilot study to investigate the hypothesis that quantitative, computer-aided B-mode ultrasound enables the noninvasive detection of hepatic steatosis. Echographic images were obtained postpartum from dairy cows (n = 12) in transcutaneous and direct (intraoperative) applications using a convex array transducer at 4.2 MHz. During surgery, a biopsy was taken from the caudate lobe to assess the liver fat content (fat score). A custom-designed software package for computer-aided ultrasound diagnosis (CAUS) was developed. After linearizing the post-processing look-up-table (LUT), the image gray levels were transferred into echo levels in decibels relative to the mean echo level in a tissue-mimicking phantom. The quantitative comparison of transcutaneous and intraoperative images enabled the correction for the attenuation effect of skin and subcutaneous fat layer on the mean echo level in the liver, as well as for the effects of the beam formation and attenuation of liver tissue on the echo level vs. depth. The residual attenuation coefficient (dB/cm) in fatty liver vs. normal liver was estimated and compensated for. Finally, echo level was estimated relative to the phantom used for calibration, and echo texture was characterized by the mean axial and lateral speckle size within the regions of interest. In the no fat/low fat group (n = 5) skin plus fat layer attenuation was 3.4 dB/cm. A correlation of skin layer thickness vs. fat score of r = 0.48 was found. The mean transcutaneous liver tissue echo level correlated well with fat score: r = 0.80. A residual liver attenuation coefficient of 0.76 dB/cm and 1.19 dB/cm was found in medium and high fat liver, respectively. In transcutaneous images, correlation of residual attenuation coefficient with fat score was r = 0.69. Axial and lateral speckle sizes were on the order of 0.2 and 1.0 cm, respectively, and no correlation was found with liver fat content. Results for transcutaneous and intraoperative images were similar. The authors conclude that this pilot study shows the feasibility of calibrated, computer-aided ultrasound for noninvasively diagnosing, possibly even screening, steatosis of the liver.  相似文献   

6.
Replacement of invasive monitoring of cerebral venous oxygenation with noninvasive techniques offers great promise in the management of life-threatening neurologic illnesses including traumatic brain injury. We developed and built an optoacoustic system to noninvasively monitor cerebral venous oxygenation; the system includes a nanosecond Nd:YAG laser and a specially designed optoacoustic probe. We tested the system in vitro in sheep blood with experimentally varied oxygenation. Our results demonstrated that (1) the amplitude and temporal profile of the optoacoustic waves increase with blood oxygenation in the range from 24% to 92%, (2) optoacoustic signals can be detected despite optical and acoustic attenuation by thick bone, and (3) the system is capable of real-time and continuous measurements. These results suggest that the optoacoustic technique is technically feasible for continuous, noninvasive monitoring of cerebral venous oxygenation.  相似文献   

7.
Different noninvasive or minimally invasive therapeutic ablation procedures can produce tissue necrosis associated with local-stiffness increase. Although elastography has been proved as a potential evaluation tool for many kinds of ablation-induced lesions, the application of subtraction technique in elastography to enhance the visualization of the ablation lesions has rarely been reported. In this paper, subtraction elastography is proposed to evaluate the ablation-induced lesions. Three models are constructed to simulate different kinds of ablated inclusions. The simulation results showed that subtraction elastography is superior to conventional elastography in detecting the ablation-induced lesions with higher signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). The artifacts induced by elastographic signal processing algorithms can be largely reduced in subtraction elastography. In addition, subtraction elastography is less influenced by the stiff background and can provide more reliable boundary information about the lesion than conventional elastography. Furthermore, the feasibility of subtraction elastography is validated by an in vitro experiment of ethanol-induced hepatic lesions. The preliminary results of this work suggest that subtraction elastography may be a good option for the evaluation of ablationinduced lesions.  相似文献   

8.
9.
Electrospinning of chitosan nanofibrous structures: feasibility study   总被引:1,自引:0,他引:1  
In this paper a range of acid aqueous solutions are studied towards their suitability for developing chitosan nanofibres by electrospinning. It was found that parameters such as type of solvent, pH, concentration of chitosan, viscosity, charge density, applied voltage, solution flow rate, distance from nozzle tip to collector surface and time play a role in the characteristics of the obtained nanofibrous structures. After a preliminary study to select the most suitable composition of the chitosan containing solution (90% acetic acid), a detailed study was done to find the optimal conditions for chitosan nanofibrous structure development. Finally long-term experiments were performed, which showed that the formation of the nanofibrous structure distorts the electrical field.  相似文献   

10.
Frette O  Stamnes JJ  Stamnes K 《Applied optics》1998,37(36):8318-8326
Optical remote sensing of ocean color is a well-established technique for inferring ocean properties. However, most retrieval algorithms are based on the assumption that the radiance received by satellite instruments is affected only by the phytoplankton pigment concentration and correlated substances. This assumption works well for open ocean water but becomes questionable for coastal waters. To reduce uncertainties associated with this assumption, we developed a new algorithm for the retrieval of marine constituents in a coastal environment. We assumed that ocean color can be adequately described by a three-component model made up of chlorophyll a, suspended matter, and yellow substance. The simultaneous retrieval of these three marine constituents and of the atmospheric aerosol content was accomplished through an inverse-modeling scheme in which the difference between simulated radiances exiting the atmosphere and radiances measured with a satellite sensor was minimized. Simulated radiances were generated with a comprehensive radiative transfer model that is applicable to the coupled atmosphere-ocean system. The method of simulated annealing was used to minimize the difference between measured and simulated radiances. To evaluate the retrieval algorithm, we used simulated (instead of measured) satellite-received radiances that were generated for specified concentrations of aerosols and marine constituents, and we tested the ability of the algorithm to retrieve assumed concentrations. Our results require experimental validation but show that the retrieval of marine constituents in coastal waters is possible.  相似文献   

11.
Camp LJ  Sharma R  Feldman MR 《Applied optics》1994,33(26):6168-6180
Guided-wave and free-space optical interconnects are compared based on insertion loss, link efficiency, connection density, time delay, and power dissipation for three types of connection networks. Three types of free-space interconnect systems are analyzed that are representative of a wide variety of free-space systems: space-variant basis-set and space-invarient systems. Results indicate that the connection density of a space-variant free space system has a connection density roughly equivalent to a two level guided-wave system with a pitch of ~10 μm (for a 1-μm wavelength) and a core refractive index of 2.0. It is also shown that the connection density of basis-set and space-invariant free-space systems can be several orders of magnitude higher than fundamental limits on the connection density of dual-level guided-wave interconnect systems when large-scale highly connected networks are employed.  相似文献   

12.
We investigate breakdown of carbon nanotube (CNT) interconnects induced by Joule heating in air and under high vacuum conditions (10(-5) mbar). A CNT with a diameter of 18 nm, which is grown by chemical vapor deposition to connect opposing titanium nitride (TiN) electrodes, is able to carry an electrical power up to 0.6 mW before breaking down under vacuum, with a corresponding maximum current density up to 8 × 10(7) A cm(-2) (compared to 0.16 mW and 2 × 10(7) A cm(-2) in air). Decoration with electrochemically deposited Ni particles allows protection of the CNT interconnect against oxidation and improvement of the heat release through the surrounding environment. A CNT decorated with Ni particles is able to carry an increased electrical power of about 1.5 mW before breaking down under vacuum, with a corresponding maximum current density as high as 1.2 × 10(8) A cm(-2). The Joule heating produced along the current carrying CNT interconnect is able to melt the Ni particles and promotes the formation of titanium carbon nitride which improves the electrical contact between the CNT and the TiN electrodes.  相似文献   

13.
A multiwavelength pyrometer is described in which the wavelength bands are selected with a direct vision prism and a diode array. The main optical and electronic parameters of the instrument are specified.Paper presented at the Second Workshop on Subsecond Thermophysics, September 20–21, 1990, Torino, Italy.  相似文献   

14.
Ultrasound-based estimation of arterial wall elasticity is commonly used to assess arterial stiffness. However, previous elastography studies have mostly addressed radial strain measurements, and the longitudinal strain has been more or less ignored. This study shows the feasibility of a speckle-tracking-based algorithm for simultaneous estimation of radial and longitudinal strain in the carotid artery in silico. Additionally, these results were preliminarily confirmed in vivo.  相似文献   

15.
A. Kamto  Y. Liu  S.L. Burkett 《Thin solid films》2009,518(5):1614-1619
Through-silicon vias (TSVs) have been extensively studied because of their ability to achieve chip stacking for enhanced system performance. The fabrication process is becoming somewhat mature. However, reliability issues need to be addressed in order for an eventual transition from laboratory to production. In our laboratory, vias with tapered sidewalls are formed through a modified Bosch process using deep reactive ion etching (DRIE). Vias are lined with silicon dioxide using plasma enhanced chemical vapor deposition (PECVD) followed by sputter deposited titanium barrier and copper seed layers before filling with a reverse pulse copper electroplating process. Following attachment of the process wafer to a carrier wafer, the process wafer is thinned from the backside by a combination of mechanical methods and reactive ion etching (RIE). Fabricated vias are subjected to thermal cycling with temperatures ranging from − 25 °C to 125 °C. For via chains, erratic changes in resistance upon temperature cycling indicated a problem with the wire bonds used to connect the sample to the test fixture. Test methods were modified to avoid wire bonding and form the basis of reliability studies presented in this paper. TSVs are shown to be stable with small increases in measured resistance for 200 cycles. In addition, small changes in resistance are observed when vias are held at elevated temperatures for extended periods of time.  相似文献   

16.
Thoroughly planned and implemented maintenance strategies save time and cost. However, the integration of maintenance work into reliability analysis is difficult as common modeling techniques are often not applicable due to state explosion which calls for restrictive model assumptions and oversimplification. From authors’ point of view, agent-based modeling (ABM) of technical and organizational systems is a promising approach to overcome such problems. But since ABM is not well established in reliability analysis its feasibility in this area still has to be demonstrated. For this purpose ABM is compared with Markov chains, namely by analyzing the reliability of a maintained n-unit system with dependent repair events, applying both modeling approaches. Although ABM and Markov chains lead to the same numerical results, the former points out the potentiality of an improved system state handling. This is demonstrated by extending the ABM with operators as additional “agents” featuring their location (x;y) availability (0;1) and different maintenance strategies. This extension highlights the capability of ABM to analyze complex emergent system behavior and allows a systematic refinement and optimization of the maintenance strategies.  相似文献   

17.
In this study, we investigated the feasibility of modifying 3-Fr IVUS catheters in several designs to potentially achieve minimally-invasive, endovascular access for image-guided ultrasound hyperthermia treatment of tumors in the brain. Using a plane wave approximation, target frequencies of 8.7 and 3.5 MHz were considered optimal for heating at depths (tumor sizes) of 1 and 2.5 cm, respectively. First, a 3.5-Fr IVUS catheter with a 0.7-mm diameter transducer (30 MHz nominal frequency) was driven at 8.6 MHz. Second, for a low-frequency design, a 220-μm-thick, 0.35 x 0.35-mm PZT-4 transducer--driven at width-mode resonance of 3.85 MHz--replaced a 40-MHz element in a 3.5-Fr coronary imaging catheter. Third, a 5 x 0.5-mm PZT-4 transducer was evaluated as the largest aperture geometry possible for a flexible 3-Fr IVUS catheter. Beam plots and on-axis heating profiles were simulated for each aperture, and test transducers were fabricated. The electrical impedance, impulse response, frequency response, maximum intensity, and mechanical index were measured to assess performance. For the 5 x 0.5-mm transducer, this testing also included mechanically scanning and reconstructing an image of a 2.5-cm-diameter cyst phantom as a preliminary measure of imaging potential.  相似文献   

18.
Newsprint recycling is responsible for significant volumes of secondary waste material for which further reprocessing and market development would be beneficial. In response to this problem, a layer lattice, ion exchange material, Al-substituted 11 Å tobermorite, has been synthesised from newsprint recycling residue comprising gehlenite (Ca2Al2SiO7), akermanite (Ca2MgSi2O7), β-dicalcium silicate (Ca2SiO4) and anorthite (CaAl2Si2O8) under hydrothermal conditions at 100 °C in the presence of NaOH. The hydrogarnet phase, katoite (Ca3Al2SiO12H8), was also formed. Similar treatment regimes in the presence of LiOH and KOH did not yield significant quantities of Al-substituted 11 Å tobermorite. A batch sorption study confirmed that the Al-substituted 11 Å tobermorite-bearing product was effective in the exclusion of Cd2+, Pb2+ and Zn2+ from acidified aqueous media. The potential to enhance the yield of Al-substituted 11 Å tobermorite relative to that of katoite and thus optimise the ion exchange efficiency of the product is discussed with respect to its application to heavy metal-contaminated wastewater treatment.  相似文献   

19.
We built and tested one of the key components of a free-space holographically interconnected stored-program optoelectronic computer: a counter. The counter is constructed with 1-ns-latency optoelectronic NOR gates and is interconnected with holographic optical elements. Two synchronization methods were also demonstrated: the gate-and-strobe method and the time-of-flight method. These counters represent prototypical optoelectronic finite-state controllers. They were developed to demonstrate the feasibility of providing optoelectronic controllers for optoelectronic processors.  相似文献   

20.
We have used a PdSi focal-plane array detector to measure short-wave infrared Raman spectra of pure compounds and human tissue. Raman bands of the pure compounds are clearly visible in the spectra, and a calcification feature at 960 cm(-1) is readily identifiable in the spectra of diseased human aorta. The performance characteristics of our detection device were good; dark noise contributed approximately 60 (electrons/s)/pixel, and the read noise was ~50 rms electrons/pixel. The primary noise in the spectra was due to fixed-pattern noise, which is the variation in measured signal across a detector when it is uniformly illuminated.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号