首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method for the determination of total phenylephrine (free plus conjugated) in human serum was developed using column-switching high-performance liquid chromatography (HPLC) with fluorescence detection. After serum was deproteinized with acetonitrile, the conjugated phenylephrine was hydrolyzed with diluted hydrochloric acid. The solution was evaporated to dryness. The reconstituted residue was analyzed with HPLC using a heart-cut technique. Good recoveries of the analytes from spiked human serum samples were obtained with small coefficients of variation. A good linear response was obtained for the concentration range 5-500 ng/ml. The lower limit of quantitation for phenylephrine in human serum was 5 ng/ml. The method was applied to the determination of phenylephrine in human serum after oral administration of phenylephrine hydrochloride.  相似文献   

2.
采用树脂分离富集金矿和铜阳极泥中的Pd、Pt、Au,结合薄样技术,利用自制X射线荧光(XRF)能谱仪同时测定这3种元素。对3种型号树脂进行了选择,确定了Amberlyst A26树脂为分离树脂,并采用单因素法对Amberlyst A26树脂柱高、流速和盐酸浓度进行了优化,确定了最佳实验条件分别为柱高10 cm、流速3 mL/min和盐酸浓度0.2 mol/L。同时对XRF分析方法进行了方法学验证。XRF能谱仪采用Mo靶激发,新型SDD探测器,结合优化的薄样技术,基本消除基体效应,可用内标法定量;仪器检出限(LLD)Pd、Pt、Au分别为0.021、0.019、0.015 μg/mL,方法检出限(LDM)分别为 0.066、0.062、0.050 μg/mL;采用11种元素的混合标准测得RSD在1.6%~7.5%之间。所测金矿样品的结果与国标法结果一致,铜阳极泥的测定结果与ICP-MS法结果基本一致。  相似文献   

3.
用于测定土壤、沉积物样品中无机元素的波长色散X射线荧光光谱法(WD-XRF)基体效应校正经验模型中,通常需要Mg、Al、Si、Ti、K、Fe、Ca等常量元素测定结果。针对能量色散X射线荧光光谱法(ED-XRF)应用方案,如果能将参与基体效应校正的元素个数压缩,不考虑Mg、Al、Si等轻元素,其分析成本和时间将明显得到优化。实验探讨了简化基体效应校正模型的可能性。基于康普顿散射和简化的基体效应校正模型,建立了土壤、沉积物样品中As、Cr、Cu、Ni、Pb、Zn、Mn、V等重金属元素的ED-XRF测定方法。用5个土壤、9个沉积物标样认定值和3个土壤考核样品WD-XRF测定结果为基准,以HJ 780—2015质控要求为依据,评估了方法的准确度和精密度。目标元素分析结果准确度合格率94.1%~100%,精密度合格率100%。基于经典的背景计数法和重复测定法评估了方法检出限。各项实验结果表明,ED-XRF可用于土壤重金属污染状况详查检测实验室质控工作。  相似文献   

4.
采用粉末样品杯法制样, 建立了用便携式X射线荧光光谱对车用三元催化剂中贵金属铑(Rh)、钯(Pd)、铂(Pt)含量进行实时、在线定量分析的方法。比较了6种实验室常用样品薄膜对测试结果的影响, 通过透光率试验发现各样品薄膜对能量高于5.4 keV(24Cr以后元素)的X射线的透光率为100%, 样品膜越薄其分析灵敏度就越好, 实验时选用厚度为4.0 μm的Ploy-4样品膜;研究了元素谱线之间的干扰重叠校正, 采用背景扫描与α经验系数法相结合的方法进行基体校正, 避免了因基体的变化对测定准确度的影响;讨论了X射线荧光光谱法中检出限的计算方法, 采用Pt、Pd、Rh含量较小样品多次测试结果的标准偏差来计算检出限, 铑、钯、铂的检出限分别为14.04 μg/g、18.17 μg/g、8.40 μg/g。对一种车用三元催化剂粉末样品进行精密度考察, 相对标准偏差(RSD)控制在4.0%之内;对8个车用三元催化剂实际样品进行分析, 经与电感耦合等离子体原子发射光谱法(ICP-AES)进行比对, 测定结果基本一致, 相对误差在10.0%之内, 方法的准确度能够满足车用三元催化剂回收要求。  相似文献   

5.
The simultaneous determination of zonisamide, a new type of antiepileptic drug, and the typical antiepileptic drugs phenobarbital, phenytoin and carbamazepine in human serum was developed using micellar electrokinetic capillary chromatography (MECC) with a diode array detector. A high correlation was revealed between the zonisamide levels in human serum obtained by MECC and those obtained by high-performance liquid chromatography (r=0.981). The serum levels of phenobarbital, phenytoin and carbamazepine determined by MECC were almost equal to those obtained by fluorescence polarization immunoassay. The reproducibility of separation and quantification with MECC analysis was appropriate for the intra- and inter-day assay coefficients. Therefore, the MECC method established here could provide a simple and efficient therapeutic drug monitoring method for antiepileptic drugs in patients, especially those treated with a combination of zonisamide and other antiepileptic drugs.  相似文献   

6.
采用硝酸分解样品,用聚环氧琥珀酸(PESA)掩蔽基体,建立了氢化物发生原子荧光光谱法(HG-AFS)测定铅锭中砷和汞的简单方法。研究了溶样方法和PESA用量对测定结果的影响,优化了氢化物发生条件及仪器的工作参数,考察了共存元素可能引起的干扰。实验表明,0.1 g铅锭溶解后加入2.0 mL PESA可以有效地掩蔽基体元素Pb,铅锭中的Ca、Cu、Sb和Sn不干扰As和Hg的测定。砷和汞的方法检出限分别为0.070 μg/L和0.011 μg/L。将方法应用于实际样品分析,砷和汞的相对标准偏差(RSD,n=5)分别在1.0%~2.0%和1.3%~1.9%之间,加标回收率分别为96%~102%和99%~103%。  相似文献   

7.
彭慧仙 《冶金分析》2015,35(7):20-26
采用高纯氧化物经四硼酸锂和碳酸锂熔融制样制备单一氧化物熔融细粉,称取不同质量单一熔融细粉混合后二次熔融合成各元素含量不同的硬质合金人工标准样品,制作校准曲线,选用经验系数法进行基体校正,建立了无定值标样下X射线荧光光谱法(XRF)测定钨钴或钨镍类钨基硬质合金中钴、镍、铁、铌、钽、铬、钨元素的分析方法。各元素校准曲线线性范围宽,相关系数均大于0.998。对人工配制标准样品的精密度进行考察,结果的相对标准偏差(RSD)小于0.5%;对硬质合金样品进行精密度考察,精密度良好。准确度验证结果表明,测定结果与GB/T 26050-2010的测试结果及化学法测定值吻合。方法的建立解决了硬质合金定值标准样品难于获得的问题。  相似文献   

8.
王勇  龚厚亮  但娟  陈小毅  刘林 《冶金分析》2018,38(10):56-62
脱硝催化剂中各元素是评估和改善催化剂效能的重要研究对象,准确、快速地测量其中各元素含量,对催化剂性能评价、失活与再生、催化剂中毒等深入研究具有重要意义。采用微波消解在酒石酸-氢氟酸-硝酸体系中消解试样,结合动态背景校正技术,采用基体匹配法消除基体效应,在选定的最佳分析谱线和仪器合适的工作条件下,使用电感耦合等离子体原子发射光谱法(ICP-AES)测定钒、钨、钼、硅、铝、钙、钡、铁、锰、铬、镁、磷、砷,从而建立了电感耦合等离子体原子发射光谱法同时测定脱硝催化剂中13种元素的分析方法。在各元素线性范围内,校准曲线的线性相关系数均在0.999以上;方法中各元素检出限为0.001%~0.021%(质量分数)。实验方法用于测定脱硝催化剂样品中钒、钨、钼、硅、铝、钙、钡、铁、锰、铬、镁、磷、砷,结果的相对标准偏差(RSD,n=7)均小于2.0%,加标回收率在94%~103%之间。按照实验方法测定3个脱硝催化剂样品中13种元素,同时采用其他方法进行比对(其中钼、钨、硅、钒、铝、钡、钙采用国家标准GB/T 31590—2015 X射线荧光光谱法测定;镁、铁、铬、磷、锰、砷采用国家标准GB/T 34701—2017电感耦合等离子体原子发射光谱法测定),测定结果相符合。  相似文献   

9.
成勇  袁金红  彭慧仙  魏芳 《冶金分析》2013,33(12):43-46
提出微波消解与电感耦合等离子体原子发射光谱法测定相结合的方法测定了钒钛磁铁矿中锆、铌、钒和铬。方法以 HF与HNO3为消解试剂,用高压密闭微波消解技术消解样品,因此钒钛磁铁矿中基体以及共存杂质氧化锆、氧化铌、氧化铬等难以被酸消解的组分可得到很好的溶解。在氢氟酸介质中测定避免了高浓度钛基体和铌、锆等待测元素在低酸度介质中容易水解所导致的影响。通过筛选待测元素分析谱线以及综合运用基体匹配与同步背景校正法消除了光谱干扰和基体效应的影响。背景等效浓度值从0.000 2%(Cr)至0.000 8%(Nb),测定下限为0.001 7%(V)~0.002 9%(Nb)。方法用于钒钛磁铁矿中锆、铌、钒和铬的测定,测定结果与火焰原子吸收光谱法及电感耦合等离子体质谱法相符,相对标准偏差(n=8)均不大于4.7%。  相似文献   

10.
硒样品经硝酸和盐酸溶解后,加入氯化羟胺将硒还原成单质硒,使基体与杂质元素分离,用氢化物发生-原子荧光光谱法测定样品中锑。研究了氢化物发生的介质和酸度、硼氢化钾溶液浓度、预还原剂用量、预还原时间、氯化羟胺用量对测定结果的影响,确定了最佳测定条件。干扰试验表明硒样品中共存元素对测定无干扰。在最佳条件下,锑浓度在0~100 ng/mL范围内与荧光强度呈良好线性关系,相关系数大于0.999 5,方法的检出限为0.23 ng/mL。将方法应用于实际样品分析,测得结果和电感耦合等离子体原子发射光谱法(ICP-AES)基本一致,相对标准偏差(n=11)小于10%。  相似文献   

11.
A method for the quantitative determination of human serum albumin in plasma and urine by post-column high-performance liquid chromatography with fluorescence detection is presented. Human serum albumin in plasma and urine is separated by gel-permeation column chromatography, which is followed by fluorescence detection. The detection uses the fluorescence enhancement observed when 8-anilino-1-naphthalenesulfonic acid binds to human serum albumin. The method is rapid to perform and is highly sensitive (detection limit is 2.5 ng/injection volume at a signal-to-noise ratio of three.  相似文献   

12.
成勇 《冶金分析》2018,38(8):63-69
作为核反应堆材料的钒铬钛合金要求严格控制成分符合V-(3%~5%)Cr-(3%~5%)Ti的比例关系,通常采用滴定法逐一测定合金组分铬、钛含量,操作繁杂周期较长。使用电感耦合等离子体原子发射光谱法(ICP-AES)测定V-4Cr-4Ti合金中铬和钛,满足快速高效同时测定钒铬钛合金中铬和钛的需要。重点研究了在钒铬钛三元合金共存体系下基体元素钒以及铬、钛相互之间的光谱干扰和基体效应,完成了对铬、钛的20余条主要谱线的光谱干扰试验和分析,最终优选了灵敏度适宜、未受共存组分光谱重叠干扰的铬、钛分析谱线;实验表明钒基体效应和连续背景叠加对测定产生正干扰,方法采用基体匹配和同步背景校正消除其影响。方法优化了仪器工作条件以及各分析谱线的积分区域、背景校正区域等检测条件。验证实验表明:铬和钛的检测范围为2.50%~6.00%,校准曲线线性相关系数大于0.9992。按照实验方法测定两个V-4Cr-4Ti合金样品中铬和钛,测定结果的相对标准偏差(RSD,n=8)小于0.70%;加标回收率为98%~102%;按照实验方法测定4个钒铬钛合金样品中铬、钛,与标准方法GB/T 4698.10—1996和YS/T 514.1—2009采用氧化还原滴定法分别测定铬和钛的测定值相吻合。  相似文献   

13.
全钒液流电池是一种应用广泛的新能源技术,固体硫酸氧钒(VOSO4·nH2O,n=3~5)则是制备钒电解液的基础原料,钒及硫酸根含量及其比例关系决定着电解液乃至钒电池的品质,因此建立了电感耦合等离子体原子发射光谱法(ICP-AES)测定钒电池硫酸氧钒中钒和硫酸根的方法。优选了待测元素灵敏度适中的分析谱线,满足了同时测定钒电池硫酸氧钒中含量范围变化较大的钒和硫酸根的需要,并且优化了分析谱线的积分区域、同步背景校正区域等仪器检测条件,改善方法检测性能。以钒和硫酸根的混合标准溶液系列绘制校准曲线,使用基体匹配法消除基体效应的影响。方法中钒和硫酸根的测定范围分别为15.0%~30.0%和35.0%~50.0%;校准曲线线性相关系数大于0.9999。实验方法用于测定2个硫酸氧钒样品中钒和硫酸根,结果的相对标准偏差(RSD,n=11)小于0.50%;回收率为96%~104%。分别使用本法测定3个硫酸氧钒样品中钒和硫酸根,并与使用过硫酸铵氧化-硫酸亚铁铵滴定法测定钒、硫酸钡重量法测定硫酸根的结果进行比对,测定结果比较吻合。  相似文献   

14.
全钒液流电池是一种应用广泛的新能源技术,固体硫酸氧钒(VOSO4·nH2O,n=3~5)则是制备钒电解液的基础原料,钒及硫酸根含量及其比例关系决定着电解液乃至钒电池的品质,因此建立了电感耦合等离子体原子发射光谱法(ICP-AES)测定钒电池硫酸氧钒中钒和硫酸根的方法。优选了待测元素灵敏度适中的分析谱线,满足了同时测定钒电池硫酸氧钒中含量范围变化较大的钒和硫酸根的需要,并且优化了分析谱线的积分区域、同步背景校正区域等仪器检测条件,改善方法检测性能。以钒和硫酸根的混合标准溶液系列绘制校准曲线,使用基体匹配法消除基体效应的影响。方法中钒和硫酸根的测定范围分别为15.0%~30.0%和35.0%~50.0%;校准曲线线性相关系数大于0.9999。实验方法用于测定2个硫酸氧钒样品中钒和硫酸根,结果的相对标准偏差(RSD,n=11)小于0.50%;回收率为96%~104%。分别使用本法测定3个硫酸氧钒样品中钒和硫酸根,并与使用过硫酸铵氧化-硫酸亚铁铵滴定法测定钒、硫酸钡重量法测定硫酸根的结果进行比对,测定结果比较吻合。  相似文献   

15.
熔融制样-X射线荧光光谱法测定连铸保护渣中7种组分   总被引:1,自引:0,他引:1  
赵海峰 《冶金分析》2017,37(4):62-66
连铸保护渣成分构成复杂,采用粉末压片制样-X射线荧光光谱法测定时基体效应严重。实验采用将样品在1 100 ℃下灼烧2 h以测定灼烧减量,选择氧化剂NH4NO3在600 ℃下对样品预氧化10 min,然后将氧化后的样品、NH4NO3与Li2B4O7-LiBO2混合熔剂(m:m=67:33)按质量比为1:2:10的比例进行熔融制样,熔片效果良好。使用专用氧化物标准样品绘制校准曲线,以数学回归法、基本参数法和理论影响系数法消除基体效应和谱线干扰,校准曲线的相关系数均大于0.999。从而建立了熔融制样-X射线荧光光谱法快速测定连铸保护渣中SiO2、Al2O3、CaO、MgO、K2O、Na2O和TFe的分析方法。对同一个连铸保护渣样品进行精密度考察,7种组分测定结果的相对标准偏差(RSD,n=10)均小于2%;准确度验证结果表明,实验方法的测定值与其他方法的测定值吻合较好。  相似文献   

16.
谢琰  曾泽  卢琪 《冶金分析》2006,26(2):1-1
试样经微波溶解,用抗坏血酸和硫脲作还原剂,氢化物发生原子荧光光谱法测定轻烧镁和水镁石中砷和汞。镁对测定的影响可通过基体匹配方法避免,样品中主要杂质和痕量元素无干扰。砷和汞的工作曲线线性范围分别为0~100 ng/mL和0~10 ng/mL,检出限分别为0.7 ng/mL和0.02 ng/mL。样品中砷和汞加标回收率分别为101.4%~107.1%和104.1%~108.5%。方法已用于轻烧镁和水镁石中砷和汞的测定。  相似文献   

17.
通过对仪器测量参数、镀层基体锌、酸度、褪镀液中六次甲基四胺浓度、以及氢氟酸用量等试验条件的研究,建立了镀锌钢板镀层中痕量锑的氢化物发生-原子荧光光谱分析方法。研究表明,锌的基体效应可以通过基体匹配法消除,酸度控制在40%(V/V),褪镀液中的六次甲基四胺和试样处理中的少量氢氟酸(不超过2 mL)对锑的测定没有影响。锑浓度在0.001~0.1 μg/mL范围内与荧光强度呈良好的线性关系;方法测定下限为0.2 μg/L。方法应用于两个镀锌钢板样品镀层中锑的分析,相对标准偏差(RSD)为1.0%和1.2%,样品加标回收率为96%~101%,测定结果与ICP-MS法一致。  相似文献   

18.
19.
A simple, rapid, and sensitive method for the determination fo the short-acting coumarin anticoagulant acenocoumarin in human serum is described. This drug is estracted from the acidified biological matrix together with the internal standard 5-methoxypsoralen. Separation and quantitation are performed on a high-performance liquid chromatograph with a reversed-phase column and an ultraviolet detector operating at 308 nm. Accuracy and precision are good. The lowest limit of detection is 15 microgram/L, which means that acenocoumarin concentrations can be measured in serum from the subtherapeutic to the toxic range. This method can also be used for rapid measurement of warfarin serum concentrations.  相似文献   

20.
A method was developed for the determination of (6R)- and (6S)-leucovorin and 5-fluorouracil in plasma. As leucovorin diastereoisomers cannot be separated on a classical reversed-phase column, it was necessary to use a chiral stationary phase. The method presented is based on the same principle as the method described by Wainer and Stiffin [J. Chromatogr., 424 (1988) 158], i.e., coupling of a bovine serum albumin phase to an achiral stationary phase. Before the chromatography, the drug was isolated from the plasma matrix by solid-phase extraction. For 5-fluorouracil, chromatography was performed on a classical RP-18 column after extraction from the plasma by liquid-liquid extraction. Both methods were validated and applied to the analysis of patients' samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号