首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A rapid, simple, and reliable gender determination of human DNA samples was successfully obtained using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. Detection sensitivity reached 0.01 ng or less for DNA samples.  相似文献   

2.
Cai Y  Jiang Y  Cole RB 《Analytical chemistry》2003,75(7):1638-1644
The formation and decomposition (postsource decay, PSD) of anionic adducts in negative ion matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry have been studied. Chloride, a small inorganic anion, has been found to form stable anionic adducts with a variety of neutral oligosaccharides that can survive the MALDI process to give readily identifiable signals (with characteristic isotope patterns) allowing subpicomole detection in the best cases. The matrixes that can aid the formation of chloride adducts of oligosaccharides have gas-phase acidities lower than or close to that of HCl (1373 kJ/mol). In PSD experiments, precursor chloride adducts of oligosaccharides yield fragment ions that retain the charge on the sugar molecule rather than solely forming Cl-, and these fragments can provide structurally informative product ions. In negative ion MALDI, highly acidic oligosaccharides do not form adducts with chloride anions, but mildly acidic saccharides (e.g., containing a carboxylic acid group) form both deprotonated molecules and chloride adducts, and each may provide structural information concerning the oligosaccharide upon decomposition.  相似文献   

3.
Current methods for the identification of mycobacteria in culture are time-consuming, requiring as long as 12 weeks for positive identification. One potential approach to rapid mycobacterial identification is to utilize proteomic profiling of cultures by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). In this report, we have applied MALDI-TOF MS to proteomic profiling of cultured microorganisms representing six species of the genus Mycobacterium. We find that analysis of acetonitrile/trifluoroacetic acid cellular extracts produces data similar to that of the analysis of deposited whole cells, while minimizing human contact with the microorganisms and rendering them nonviable. A matrix composition of alpha-cyano-4-hydroxycinnamic acid with fructose yields highly reproducible MALDI-TOF spectra. Statistical analysis of MALDI-TOF MS data allows differentiation of each individual mycobacterial species on the basis of unique mass fingerprints. The methodology allows identification of a number of unique (potentially diagnostic) biomarkers as targets for protein identification by MS/MS experiments. In addition, we observe a number of signals common to all mycobacterial species studied by MALDI-TOF MS, which may be genus-specific biomarkers. The potentially genus-specific biomarkers occur at low mass (<2 kDa) and are likely to be lipids and cell wall components such as mycolic acids. This study demonstrates the potential for mass spectrometry-based identification/classification of mycobacteria.  相似文献   

4.
Accurate and reproducible quantification of glycans from protein drugs has become an important issue for quality control of therapeutic proteins in biopharmaceutical and biotechnology industries. Mass spectrometry is a promising tool for both qualitative and quantitative analysis of glycans owing to mass accuracy, efficiency, and reproducibility, but it has been of limited success in quantitative analysis for sialylated glycans in a high-throughput manner. Here, we present a solid-phase permethylation-based total N-glycan quantitative method that includes N-glycan releasing, purification, and derivatization on a 96-well plate platform. The solid-phase neutralization enabled us to perform reliable absolute quantification of the acidic N-glycans as well as neutral N-glycans from model glycoproteins (i.e., chicken ovalbumin and porcine thyroglobulin) by only using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS). Furthermore, low-abundance sialylated N-glycans from human serum prostate specific antigen (PSA), an extremely valuable prostate cancer marker, were initially quantified, and their chemical compositions were proposed. Taken together, these results demonstrate that our all-inclusive glycan preparation method based on a 96-well plate platform may contribute to the precise and reliable qualitative and quantitative analysis of glycans.  相似文献   

5.
Chen H  He M  Pei J  He H 《Analytical chemistry》2003,75(23):6531-6535
Quantitative analyses of synthetic polymers were accomplished using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI TOF MS). Many factors have hindered the development of quantitative measurement of polymers via MALDI TOF MS, e.g., laser power, matrix, cation salt, and cocrystallization. By probing the optimal conditions, two sets of polymers were studied. Fair repeatability of the samples ensures acceptable results. In set 1, two poly(ethylene glycols) with different end groups showed equal desorption/ionization efficiencies. Two synthetic polymers in set 2 with different chemical properties resulted in different MALDI responses. Good linearity was achieved by plotting the relationship between the sample concentration ratio and the total signal intensity ratio in both sets.  相似文献   

6.
Glycan phosphorylation is a significant feature of complex carbohydrate chemistry and glycobiology. For example, N-linked glycans containing mannose-6-phosphate (Man-6-P) residues play a key role as targeting signals for the transport of proteins from the Golgi apparatus to lysosomes. Structural information on Man-6-P glycans involved in transport of proteins is usually obtained using nuclear magnetic resonance (NMR) spectroscopy. However, an alternative and simple method with comparable accuracy is desirable because large amounts of samples and special techniques are required for structural analysis using NMR. Recently, postsource decay (PSD) fragment spectra obtained by matrix-assisted laser desorption-ionization time-of-flight mass spectrometry (MALDI-TOF MS) have provided critical information on complex carbohydrates. Since few Man-6-P-containing glycans are commercially available, very little information has been collected on the mass spectrometry of phosphorylated glycans. In this report, four kinds of phosphorylated glycans labeled with 2-aminopyridine (PA) were purified from yeast mannan, and their PSD spectra were measured in the positive ion mode. The phospho-6-O-mannose monoester linkages (PO3H-Man) in glycans are stable, although cleavage of the mannose-1-phosphate linkage (Man-alpha-1-PO3H) occurs readily. Fragment ions indicated the presence of the alpha-1,3-branching chain of an N-linked high-mannose-type glycan, and characteristic fragmentation patterns were observed for phosphorylated glycans. On the basis of the MALDI-PSD spectra, we deduced fragmentation rules for phosphorylated N-glycans that will be valuable for distinguishing the position of phosphorylation.  相似文献   

7.
The purpose of this study is to develop a novel bacterial analysis method by coupling the flow field-flow fractionation (flow FFF) separation technique with detection by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. The composition of carrier liquid used for flow FFF was selected based on retention of bacterial cells and compatibility with the MALDI process. The coupling of flow FFF and MALDI-TOF MS was demonstrated for P. putida and E. coli. Fractions of the whole cells were collected after separation by FFF and further analyzed by MALDI-MS. Each fraction, collected over different time intervals, corresponded to different sizes and possibly different growth stages of bacteria. The bacterial analysis by flow FFF/MALDI-TOF MS was completed within 1 h with only preliminary optimization of the process.  相似文献   

8.
A novel ionization source for biological mass spectrometry is described that combines atmospheric pressure (AP) ionization and matrix-assisted laser desorption/ionization (MALDI). The transfer of the ions from the atmospheric pressure ionization region to the high vacuum is pneumatically assisted (PA) by a stream of nitrogen, hence the acronym PA-AP MALDI. PA-AP MALDI is readily interchangeable with electrospray ionization on an orthogonal acceleration time-of-flight (oaTOF) mass spectrometer. Sample preparation is identical to that for conventional vacuum MALDI and uses the same matrix compounds, such as alpha-cyano-4-hydroxycinnamic acid. The performance of this ion source on the oaTOF mass spectrometer is compared with that of conventional vacuum MALDI-TOF for the analysis of peptides. PA-AP MALDI can detect low femtomole amounts of peptides in mixtures with good signal-to-noise ratio and with less discrimination for the detection of individual peptides in a protein digest. Peptide ions produced by this method generally exhibit no metastable fragmentation, whereas an oligosaccharide ionized by PA-AP MALDI shows several structurally diagnostic fragment ions. Total sample consumption is higher for PA-AP MALDI than for vacuum MALDI, as the transfer of ions into the vacuum system is relatively inefficient. This ionization method is able to produce protonated molecular ions for small proteins such as insulin, but these tend to form clusters with the matrix material. Limitations of the oaTOF mass spectrometer for singly charged high-mass ions make it difficult to evaluate the ionization of larger proteins.  相似文献   

9.
In this paper, we report for the first time use of laser desorption mass spectrometry for measurement of chemical cleavage sequencing products of DNA. In this method, the target DNA was labeled with biotin and subjected to chemical modification and cleavage according to the Maxam-Gilbert sequencing protocol. The biotin-containing fragments were captured by streptavidin-coated magnetic beads and separated from the other fragments. The captured fragments were released by hot ammonia treatment, and the released fragments were analyzed by mass spectrometry. Potential applications of this method in resolving sequence ambiguities and sequencing repeat sequences as well as in the analysis of DNA-protein interactions are discussed.  相似文献   

10.
Chen H  He M  Pei J  Liu B 《Analytical chemistry》2002,74(24):6252-6258
An analytical method based on matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been applied to provide information on the structure of a copolymer, e.g., repeat unit and end group. Seven conjugated polymers, which have been demonstrated as the active component in blue light-emitting diodes, were synthesized through Suzuki polycondensation reaction in the presence of Pd(PPh3)4 catalyst. Their molecular weights were obtained using gel permeation chromatography analysis. MALDI-TOF MS was used to investigate the structure information in detail. The proposed end-group structures were confirmed by the identity between the observed and the simulated isotopic distribution of each polymer. The results demonstrate that these synthetic polymers possess various end groups and even contain macrocycles. The catalyst Pd(PPh3)4 was found to introduce phenyl end groups via aryl-aryl exchange between the catalytic palladium intermediate and the triphenylphosphine ligand. All these results are based on the analysis of the mass spectrum data, which suggests that MALDI-TOF MS is an extraordinarily strong tool in synthetic polymer structure analysis.  相似文献   

11.
Na DH  DeLuca PP  Lee KC 《Analytical chemistry》2004,76(9):2669-2673
A quantitative determination of peptides incorporated into poly(d,l-lactide-co-glycolide) microspheres by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) was accomplished in a single step without pretreatment for extracting the peptide from the microsphere. The conventional extraction methods often underestimate the actual amount of peptide because of incomplete extraction from the microspheres or loss during the procedures. In this study, the microspheres dissolved in acetonitrile containing 0.1% trifluoroacetic acid were mixed with matrix solution containing the internal standard, and the peptide content was directly determined by MALDI-TOF MS. The drug content values determined by MALDI-TOF MS in both the leuprolide- and salmon calcitonin-incorporated microspheres were closer to the theoretical contents than those determined by the conventional extraction method. This method using MALDI-TOF MS could be a good alternative to time-consuming and less-accurate conventional methods.  相似文献   

12.
This work proposes for the first time the use of hollow-fiber flow field-flow fractionation (HF FlFFF) for improved matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI/TOFMS) of whole bacteria. HF FlFFF has proved to be able to prepurify or fractionate different species of whole bacteria. Sample preparation by HF FlFFF gives improved spectra quality because noncellular components possibly present in the sample can be separated from the cells. When a mixture of two bacteria (Bacillus subtilis and Escherichia coli) is fractionated through HF FlFFF, MALDI/TOFMS analysis of each separated bacterial species preserves the most characteristic ion signals of the species without the presence of characteristic signals of the other species. The main advantages of HF FlFFF for MALDI/TOFMS analysis of whole bacteria are miniaturization, simplicity, and low cost of the fractionator components. This low cost makes disposable usage of the fractionator possible, thus eliminating the risk of run-to-run contamination of spectra due to sample carryover. The low fractionator volume yields bacterial fractionation on the order of a few minutes, which is comparable to MALDI/TOFMS analysis time. The small fractionation volume makes sample dilution low enough so that additional sample concentration steps are not strictly required to preserve MALDI/TOFMS detection.  相似文献   

13.
Application of mass spectrometry imaging (MS imaging) analysis to single cells was so far restricted either by spatial resolution in the case of matrix-assisted laser desorption/ionization (MALDI) or by mass resolution/mass range in the case of secondary ion mass spectrometry (SIMS). In this study we demonstrate for the first time the combination of high spatial resolution (7 μm pixel), high mass accuracy (<3 ppm rms), and high mass resolution (R = 100?000 at m/z = 200) in the same MS imaging measurement of single cells. HeLa cells were grown directly on indium tin oxide (ITO) coated glass slides. A dedicated sample preparation protocol was developed including fixation with glutaraldehyde and matrix coating with a pneumatic spraying device. Mass spectrometry imaging measurements with 7 μm pixel size were performed with a high resolution atmospheric-pressure matrix-assisted laser desorption/ionization (AP-MALDI) imaging source attached to an Exactive Orbitrap mass spectrometer. Selected ion images were generated with a bin width of Δm/z = ±0.005. Selected ion images and optical fluorescence images of HeLa cells showed excellent correlation. Examples demonstrate that a lower mass resolution and a lower spatial resolution would result in a significant loss of information. High mass accuracy measurements of better than 3 ppm (root-mean-square) under imaging conditions provide confident identification of imaged compounds. Numerous compounds including small metabolites such as adenine, guanine, and cholesterol as well as different lipid classes such as phosphatidylcholine, sphingomyelin, diglycerides, and triglycerides were detected and identified based on a mass spectrum acquired from an individual spot of 7 μm in diameter. These measurements provide molecularly specific images of larger metabolites (phospholipids) in native single cells. The developed method can be used for a wide range of detailed investigations of metabolic changes in single cells.  相似文献   

14.
A method was developed for mass spectrometric detection of neurotensin (NT)-like immunoreactivity and quantification of NT in human brain tissue. The method is based on immunoprecipitation followed by analysis using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The identity of the major component of the immunoprecipitates as neurotensin was confirmed by fragment ion analysis on an electrospray ionization quadrupole time-of-flight instrument. MALDI-TOF-MS quantification of NT was achieved using stable-isotope-labeled NT as the internal standard, yielding an error of less than 5%. The method allowed detection of low-femtomole amounts of NT, staring from low-milligram amounts of lyophilized brain tissue. In addition to NT, several other peptides were detected in the purified samples, most of which, according to their molecular masses, corresponded to fragments of NT. The method is demonstrated with quantification of NT from human hypothalamus tissue, and a comparison is made with results obtained from competitive radioimmunoassay.  相似文献   

15.
Gadolinium (III) complexes are under intense scrutiny as contrast agents for magnetic resonance imaging. Although currently used mainly as extracellular agents, there is a growing interest to exploit their contrast enhancing ability in the intracellular environment. To ascertain the preservation of their chemical integrity upon the intracellular entrapment, it is necessary to have a method for their dosage in the cell lysates. Herein, a mass spectrometric method for detection and quantification of gadolinium complexes in cell lysates is reported. The detection by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was carried out by using a non-acidic matrix (2,4,6-trihydroxyacetophenone), which does not allow any leakage of gadolinium from the complex. Quantification has been possible by using as an internal standard an ytterbium complex with the same ligand of the analyte. Ytterbium was chosen because, among the lanthanides, it is the one with the isotopic distribution pattern the most similar to that of gadolinium. Sensitivity was enough to detect low micromolar quantities of a cationic complex and high micromolar quantities of a neutral complex in cell lysates of rat hepatoma cells. In the case of anionic complexes, sensitivity was too low for quantitative analysis. To the best of our knowledge, this is the first report concerning the quantification of metal complexes by MALDI-TOF-MS.  相似文献   

16.
Cross-ring cleavage ions produced by in-source decay (ISD), as well as deprotonated molecular ions [M - H]-, are invariably observed in negative-ion linear-mode matrix-assisted laser desorption/ionization time-of-flight mass spectrometry spectra of neutral oligosaccharides with 9H-pyrido[3,4-b]indole (norharman) as a matrix. The patterns of ISD ions depend on the oligosaccharide linkage type; thus, these ions are potentially useful in linkage analysis. In postsource decay (PSD) spectra from chlorinated molecular ions [M + Cl]-, all PSD ions are observed in the deprotonated form, although no deprotonated molecular ions are detected. In oligosaccharides having an alditol at the reducing end, deprotonated molecular ions [M - H]- are clearly seen in linear-mode mass spectra and survive in the PSD measurements. These results indicate that the deprotonation process drives ISD and PSD of oligosaccharides and that keto-enol tautomerization at the reducing terminal promotes ISD and PSD processes.  相似文献   

17.
Chan TW  Duan L  Sze TP 《Analytical chemistry》2002,74(20):5282-5289
A new analytical scheme based on a combination of scanning FTMS, multiple-ion filling, and potential ramping methods has been developed for accurate molecular mass measurement of peptide and protein mixtures using broadband MALDI-FTMS. The scanning FTMS method alleviates the problems of time-of-flight effect for FTMS with an external MALDI ion source and provides a systematic means of sampling ions of different mass-to-charge ratios. The multiple-ion filling method is an effective way of trapping and retaining ions from successive ion generation/accumulation events. The potential ramping method allows the use of high trapping potentials for effective trapping of ions of high kinetic energies and the use of low trapping potentials for high-resolution detection of the trapped ions. With this analytical scheme, high-resolution broadband MALDI mass spectra covering a wide mass range of 1000-5700 Da were obtained. For peptide mixtures of mass range 1000-3500 Da, calibration errors of low part-per-millions were demonstrated using a parabolic calibration equation f2 = ML1/m2 + ML2/m + ML3, where f is the measured cyclotron frequency and ML1, ML2, and ML3 are calibration constants.  相似文献   

18.
Du Z  Yang R  Guo Z  Song Y  Wang J 《Analytical chemistry》2002,74(21):5487-5491
To evaluate the performance of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) in identifying Staphylococcus aureus and in determining its methicillin resistance, we analyzed 76 S. aureus clinical isolates using a linear MALDI-TOF MS. Spectral profile data obtained were compared with the database provided with the instrument, and 74% of the isolates were identified as S. aureus, as confirmed by a nuc-based PCR test. The determination of the methicillin resistance in S. aureus is based on the fact that the spectral profiles of methicillin-susceptible S. aureus (MSSA) and methicillin-resistant S. aureus (MRSA) differ greatly from each other. Replicate spectral profiles obtained from each isolate were combined to be a representative spectrum of it, and representative spectral profiles from all the isolates constitute a user's self-established database. All the spectral profiles in the database were classified into two groups based on clustering analysis, and one is for MSSA and another MRSA. There was a little discrepancy between the results from MALDI-TOF MS and from PCR. Seven isolates that are negative for the mecA gene by PCR were identified as MRSA by MALDI-TOF MS. The discrepancy may be partially explained by the heterogeneous nature of methicillin resistance in S. aureus. Our results suggested that comparison of MALDI-TOF MS spectral profiles of microorganism could serve as a simple and rapid method for bacterial identification and antibiotic susceptibility analysis.  相似文献   

19.
Room-temperature ionic liquids are useful as solvents for organic synthesis, electrochemical studies, and separations. We wished to examine whether their high solubalizing power, negligible vapor pressure, and broad liquid temperature range are advantageous if they are used as matrixes for UV-MALDI. Several different ionic matrixes were synthesized and tested, using peptides, proteins, and poly(ethylene glycol) (PEG-2000). All ionic liquids tested have excellent solubilizing properties and vacuum stability compared to other commonly used liquid and solid matrixes. However, they varied widely in their ability to produce analyte gas-phase ions. Certain ionic matrixes, however, produce homogeneous solutions of greater vacuum stability, higher ion peak intensity, and equivalent or lower detection limits than currently used solid matrixes. Clearly, ionic liquids and their more amorphous solid analogues merit further investigation as MALDI matrixes.  相似文献   

20.
The significance and epidemiological effects of metals to life necessitate the development of direct, efficient, and rapid method of analysis. Taking advantage of its simple, fast, and high-throughput features, we present a novel approach to metal ion detection by matrix-functionalized magnetic nanoparticle (matrix@MNP)-assisted MALDI-MS. Utilizing 21 biologically and environmentally relevant metal ion solutions, the performance of core and matrix@MNP against conventional matrixes in MALDI-MS and laser desorption ionization (LDI) MS were systemically tested to evaluate the versatility of matrix@MNP as ionization element. The matrix@MNPs provided 20- to >100-fold enhancement on detection sensitivity of metal ions and unambiguous identification through characteristic isotope patterns and accurate mass (<5 ppm), which may be attributed to its multifunctional role as metal chelator, preconcentrator, absorber, and reservoir of energy. Together with the comparison on the ionization behaviors of various metals having different ionization potentials (IP), we formulated a metal ionization mechanism model, alluding to the role of exciton pooling in matrix@MNP-assisted MALDI-MS. Moreover, the detection of Cu in spiked tap water demonstrated the practicability of this new approach as an efficient and direct alternative tool for fast, sensitive, and accurate determination of trace metal ions in real samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号