首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The suitability of mathematical models used to extract kinetic information from correlated data constitutes a significant issue in fluorescence correlation spectroscopy (FCS). Standard FCS equations are derived from a simple Gaussian approximation of the optical detection volume, but some investigations have suggested this traditional practice can lead to inaccurate and misleading conclusions under many experimental circumstances, particularly those encountered in one-photon confocal measurements. Furthermore, analytical models cannot be derived for all measurement scenarios. We describe a novel numerical approach to FCS that circumvents conventional analytical models, enabling meaningful analyses even under extraordinarily unusual measurement conditions. Numerical fluorescence correlation spectroscopy (NFCS) involves quantitatively matching experimental correlation curves with synthetic curves generated via diffusion simulation or direct calculation based on an experimentally determined 3D map of the detection volume. Model parameters are adjusted iteratively to minimize the residual differences between synthetic and experimental correlation curves. In order to reduce analysis time, we distribute calculations across a network of processors. As an example of this new approach, we demonstrate that synthetic autocorrelation curves correspond well with experimental data and that NFCS diffusion measurements of Rhodamine B remain constant, regardless of the distortion present in a confocal detection volume.  相似文献   

2.
In fluorescence correlation spectroscopy (FCS) analysis it is generally assumed that molecular species diffuse freely in volumes much larger than the three-dimensional FCS observation volume. However, this standard assumption is not valid in many measurement conditions, particularly in tubular structures with diameters in the micrometer range, such as those found in living cells (organelles, dendrites) and microfluidic devices (capillaries, reaction chambers). As a result the measured autocorrelation functions (ACFs) deviate from those predicted for free diffusion, and this can shift the measured diffusion coefficient by as much as ~50% when the tube diameter is comparable with the axial extension of the FCS observation volume. We show that the range of validity of the FCS measurements can be drastically improved if the tubular structures are located in the close vicinity of a mirror on which FCS is performed. In this case a new fluctuation time in the ACF, arising from the diffusion of fluorescent probes in optical fringes, permits measurement of the real diffusion coefficient within the tubular structure without assumptions about either the confined geometry or the FCS observation volume geometry. We show that such a measurement can be done when the tubular structure contains at least one pair of dark and bright fringes resulting from interference between the incoming and the reflected excitation beams on the mirror surface. Measurement of the diffusion coefficient of the enhanced green fluorescent protein (EGFP) and IscS-EGFP in the cytoplasm of living Escherichia coli illustrates the capabilities of the technique.  相似文献   

3.
Over the years fluorescence correlation spectroscopy (FCS) has proven to be a useful technique that has been utilized in several fields of study. Although FCS initially suffered from poor signal-to-noise ratios, the incorporation of confocal microscopy has overcome this drawback and transformed FCS into a sensitive technique with high figures of merit. In addition, tandem methods have evolved to include dual-color cross-correlation, total internal reflection fluorescence correlation, and fluorescence lifetime correlation spectroscopy combined with time-correlated single-photon counting. In this review, we discuss several applications of FSC for biochemical, microfluidic, and cellular investigations.  相似文献   

4.
In this paper we present and demonstrate a technique for mapping fluid flow rates in microfluidic systems with sub-micrometer resolution using confocal microscopy in conjunction with fluorescence correlation spectroscopy (FCS). Flow velocities ranging from approximately 50 microm/s to approximately 10 cm/s can be recorded using fluorescent polymer nanospheres as fluid motion tracers. Velocity profiles and images of the flow in poly(dimethylsiloxane)-glass microchannels are presented and analyzed. Using the method, velocity images along the horizontal (top view) and vertical planes within a microdevice can be obtained. This is, to our knowledge, the first report of FCS for producing velocity maps. The high-resolution velocity maps can be used to characterize and optimize microdevice performance and to validate simulation efforts.  相似文献   

5.
Song W  Moon S  Lee BC  Park CS  Kim DY  Kwon HS 《Applied optics》2011,50(20):3529-3537
We present the development and implementation of a spatially and spectrally resolved multipoint fluorescence correlation spectroscopy (FCS) system utilizing multiple end-capped optical fibers and an inexpensive laser source. Specially prepared end-capped optical fibers placed in an image plane were used to both collect fluorescence signals from the sample and to deliver signals to the detectors. The placement of independently selected optical fibers on the image plane was done by monitoring the end-capped fiber tips at the focus using a CCD, and fluorescence from specific positions of a sample were collected by an end-capped fiber, which could accurately represent light intensities or spectral data without incurring any disturbance. A fast multipoint spectroscopy system with a time resolution of ~1.5 ms was then implemented using a prism and an electron multiplying charge coupled device with a pixel binning for the region of interest. The accuracy of our proposed system was subsequently confirmed by experimental results, based on an FCS analysis of microspheres in distilled water. We expect that the proposed multipoint site-specific fluorescence measurement system can be used as an inexpensive fluorescence measurement tool to study many intracellular and molecular dynamics in cell biology.  相似文献   

6.
Roach CA  Neal SL 《Applied spectroscopy》2010,64(10):1145-1153
Fluorescence correlation spectroscopy (FCS) uses fluctuations in the fluorescence collected from a small illuminated volume to measure dynamic processes of fluorophores. In traditional FCS, spectral overlap produces cross-talk in dedicated detector channels, undermining the accuracy of measurements of molecular interactions. Here, the experimental realization of full-spectrum fluorescence correlation spectroscopy is described and coupled with multivariate data analysis to numerically correct detector cross-talk, isolating spectra and fluctuation traces of mixture components in spite of overlap. Application of this methodology is illustrated using the measurement of the diffusion constant of labeled polystyrene in hydroxypropyl cellulose in the presence of a persistent dye. Additionally, the results show that full-spectrum FCS with multivariate analysis can isolate and characterize signals from unanticipated sample components.  相似文献   

7.
The dynamic behaviour of gold nanoparticles functionalised with glucose (Glc‐Au NPs) has been studied here by means of fluorescence correlation spectroscopy (FCS). Meaningful data on the state of aggregation and dynamics of Glc‐Au NPs fluorescently‐labelled with HiLyte Fluor647 (Glc‐Au‐Hi NPs) in the intracellular environment were obtained. Moreover, the work presented here shows that FCS can be used to visualise the presence of single NPs or NP aggregates following uptake and to estimate, locally, NP concentrations within the cell. FCS measurements become possible after applying a “prebleaching” methodology, when the immobile NP fraction has been effectively removed and thus significant FCS data has been recorded. In this study, Glc‐Au‐Hi NPs have been incubated with HepG2 cells and their diffusion time in the intracellular environment has been measured and compared with their diffusion value in water and cell media.  相似文献   

8.
L Ruan  Z Xu  T Lan  J Wang  H Liu  C Li  C Dong  J Ren 《Analytical chemistry》2012,84(17):7350-7358
Apoptosis plays a crucial role in many biological processes and pathogenesis of various malignancies and diseases of the immune system. In this paper, we described a novel method for sensitive detection of drug-induced apoptosis by using fluorescence correlation spectroscopy (FCS). The principle of this method is based on the assay of DNA fragmentation in the process of the drug-induced apoptosis. FCS is a single molecule method, and it can be used for sensitive and selective assay of DNA fragmentation without separation. We first developed a highly sensitive method for characterization of DNA fragments using a home-built FCS system and SYBR Green I as fluorescent DNA-intercalating dye, and then established a model of drug-induced apoptosis using human pancreatic cancer cells and a drug lidamycin. Furthermore, FCS method established was used to directly detect the fragmentation of DNA extracted from apoptotic cells or in the apoptotic cell lysate. In FCS assay, the single-component model and the multiple-components model were used to fit raw FCS data. The characteristic diffusion time of DNA fragments was used as an important parameter to distinguish the apoptotic status of cells. The obtained data documented that the characteristic diffusion time of DNA fragments from apoptotic cells significantly decreased with an increase of lidamycin concentration, which implied that DNA fragmentation occurred in lidamycin-induced apoptosis. The FCS results are well in line with the data obtained from flow cytometer and gel electrophoresis. Compared to current methods, the method described here is sensitive and simple, and more importantly, our detection volume is less than 1 fL, and the sample requirement can easily be reduced to nL level using a droplets array technology. Therefore, our method probably becomes a high throughput detection platform for early detection of cell apoptosis and screening of apoptosis-based anticancer drugs.  相似文献   

9.
In this report, a combined imaging and fluorescence correlation spectroscopy (FCS) method is described and its ability to characterize microsecond fluctuations in the fluorescence emission of a sample is demonstrated. A sample scanning laser confocal microscope is operated in the customary way while recording the time that each photon is detected with a time resolution of 50 ns using a low-cost counting board. The serial data stream of photon detection times allows access to fluorescence signal fluctuations that can be used to characterize dynamics using correlation methods. The same data stream is used to generate images of the sample. Using the technique, we demonstrate that it is possible to characterize the kinetics of transitions to and from nonemitting or "dark" states of the fluorescent dyes DiIC16 and ATTO 520. Results are similar to, but deviate slightly from, a model that has been frequently used for extracting singlet-triplet: conversion rates using conventional solution-based FCS. Like conventional FCS, the concentration, or in our case the areal density of coverage, of fluorescent species can also be obtained. Many single-molecule fluorescence experiments aim to extract kinetics from intensity trajectories; this method may be used as a rapid and convenient technique for characterization of surface-linked or thin-film samples prior to performing the more time and effort intensive single-molecule measurements. Besides the capacity to measure photophysical phenomena, the surface-sensitive FCS method could also be applied for measuring conformational changes or interaction kinetics for species immobilized on a surface. One possible scenario is measurements of the frequency and duration of association of ligand-receptor pairs where a fluorescently labeled component is freely diffusing and the other is surface immobilized. Given that microarrays of custom-designed, surface-immobilized peptides and nucleic acids are now readily available, the ability to sensitively measure association and dissociation rates of the surface-linked species with a freely diffusing species could be a useful extension to what has already become an extremely important tool for characterizing the interactions of biomolecules.  相似文献   

10.
We describe a new technique for performing multicomponent analysis using a combination of capillary electrophoresis (CE) and fluorescence correlation spectroscopy (FCS), which we refer to as CE/FCS. FCS is a highly sensitive and rapid optical technique that is often used to perform multicomponent analysis in static solutions based on the different diffusion times of the analyte species through the detection region of a tightly focused laser beam. In CE/FCS, transit times are measured for a mixture of analytes continuously flowing through a microcapillary in the presence of an electric field. Application of an electric field between the inlet and outlet of the capillary alters the transit times, depending on the magnitude and polarity of the applied field and the electrophoretic mobilities of the analytes. Multicomponent analysis is accomplished without the need to perform a chemical separation, due to the different electrophoretic mobilities of the analytes. This technique is particularly applicable to ultradilute solutions of analyte. We have used CE/FCS to analyze subnanomolar aqueous solutions containing mixtures of Rhodamine 6G (R6G) and R6G-labeled deoxycytosine triphosphate nucleotides. Under these conditions, fewer than two molecules were typically present in the detection region at a time. The relative concentrations of the analytes were determined with uncertainties of ~10%. Like diffusional FCS, this technique is highly sensitive and rapid. Concentration detection limits are below 10(-)(11) M, and analysis times are tens of seconds or less. However, CE/FCS does not require the diffusion coefficients of the analytes to be significantly different and can, therefore, be applied to multicomponent analysis of systems that would be difficult or impossible to study by diffusional FCS.  相似文献   

11.
Near-field scanning optical microscopy (NSOM) is a high-resolution scanning probe technique capable of obtaining simultaneous optical and topographic images with spatial resolution of tens of nanometers. We have integrated time-correlated single-photon counting and NSOM to obtain images of fluorescence lifetimes with high spatial resolution. The technique can be used to measure either full fluorescence lifetime decays at individual spots with a spatial resolution of <100 nm or NSOM fluorescence images using fluorescence lifetime as a contrast mechanism. For imaging, a pulsed Ti:sapphire laser was used for sample excitation and fluorescent photons were time correlated and sorted into two time delay bins. The intensity in these bins can be used to estimate the fluorescence lifetime at each pixel in the image. The technique is demonstrated on thin films of poly(9,9'-dioctylfluorene) (PDOF). The fluorescence of PDOF is the results of both inter- and intrapolymer emitting species that can be easily distinguished in the time domain. Fluorescence lifetime imaging with near-field scanning optical microscopy demonstrates how photochemical degradation of the polymer leads to a quenching of short-delay intrachain emission and an increase in the long-delay photons associated with interpolymer emitting species. The images also show how intra- and interpolymer species are uniformly distributed in the films.  相似文献   

12.
Fluorescence correlation spectroscopy (FCS) is an ideal tool for measuring molecular diffusion and size under extremely dilute conditions. However, the power of FCS has not been utilized to its best to measure diffusion and size parameters of complex chemical systems. Here, we apply FCS to measure the size, and, most importantly, the size distribution and polydispersity of a supramolecular nanostructure (i.e., microemulsion droplets, MEDs) in dilute solution. It is shown how the refractive index mismatch of a solution can be corrected in FCS to obtain accurate size parameters of particles, bypassing the optical matching problem of light scattering techniques that are used often for particle-size measurements. We studied the MEDs of 13 different W(0) values from 2 to 50 prepared in a ternary mixture of water, sodium bis(2-ethylhexyl) sulfosuccinate (AOT), and isooctane, with sulforhodamine-B as a fluorescent marker. We find that, near the optical matching point of MEDs, the dynamic light scattering (DLS) measurements underestimate the droplet sizes while FCS estimates the accurate ones. A Gaussian distribution model (GDM) and a maximum-entropy-based FCS data fitting model (MEMFCS) are used to analyze the fluorescence correlation curves that unfold Gaussian-type size distributions of MEDs in solution. We find the droplet size varies linearly with W(0) up to ~20, but beyond this W(0) value, the size variation deviates from this linearity. To explain nonlinear variation of droplet size for W(0) values beyond ~20, we invoke a model (the coated-droplet model) that incorporates the size polydispersity of the droplets.  相似文献   

13.
He H  Xie C  Ren J 《Analytical chemistry》2008,80(15):5951-5957
In this paper, we investigated the fluorescent properties of gold nanoparticles (GNPs) with several tens of nanometers by ensemble fluorescence spectrometry, fluorescence correlation spectroscopy (FCS), and fluorescence microscopy. We observed that GNPs synthesized by the citrate reduction of chloroauric acid possessed certain fluorescence, narrow full width at half-maximum (17 nm), and with an increase of particle sizes, the emission intensity showed a gradual increase while the emission wavelength remained almost constant (at 610 nm). Especially, the fluorescence of GNPs possessed the excellent behavior of antiphotobleaching under strong light illumination. Despite their low quantum yields, GNPs exhibited strong native fluorescence under relatively high excitation power. The fluorescence of GNPs could be characterized by fluorescence imaging and FCS at the single particle level. On the basis of this excellent antiphotobleaching of GNPs and easy photobleaching of cellular autofluorescence, we developed a new method for imaging of cells using GNPs as fluorescent probes. The principle of this method is that after cells stained with GNPs or GNPs bioconjugates are illuminated by strong light, the cellular autofluorescence are photobleached and the fluorescence of GNPs on cell membrane or inside cells can be collected for cell imaging. On the basis of this principle, we imaged living HeLa cells using GNPs as fluorescent probes and obtained good cell images by photobleaching of cellular autofluorescence. Furthermore, anti-EGFR/GNPs were successfully used as targeted probes for fluorescence imaging of cancer cells. Our preliminary results demonstrated that GNPs possessed excellent behaviors of antiphotobleaching and were good fluorescent probes in cell imaging. Our cellular imaging method described has potential applications in cancer diagnostics, studies, and immunoassays.  相似文献   

14.
Noble-metal nanoparticles labeled with fluorescent molecules are used in a variety of applications requiring the measurement of size and diffusion properties of single nanoprobes. We have successfully used intrinsic surface-plasmon-induced photoluminescence (SPPL) signatures of monodispersed bare gold and silver nanoparticles in water to detect and measure their precise diffusion coefficient, concentration and hydrodynamic radius by fluorescence correlation spectroscopy (FCS). Measurement of the effective hydrodynamic radius confirms particle size to be 80 ± 8 and 64 ± 14 nm for gold and silver, respectively, which is in excellent agreement with scanning electron microscopic measurements made on the same particles. Detection of bare gold and silver nanoparticles at the single-molecule level with moderately high value of "per particle brightness" (PPB) confirms those particles to be used as fluorescent probes in biological research and in different medical and biotechnology applications where fluorescence detection plays a vital role. Additionally, these results demonstrate an alternative method for measuring hydrodynamic properties, particularly the size-distribution of bare noble-metal nanoparticles in solution using data-fitting algorithm for FCS based on the maximum entropy method (MEMFCS).  相似文献   

15.
Qing DK  Mengüç MP  Payne FA  Danao MG 《Applied optics》2003,42(16):2987-2994
Fluorescence correlation spectroscopy (FCS) is adapted for a new procedure to detect trace amounts of Escherichia coli in water. The present concept is based on convective diffusion rather than Brownian diffusion and employs confocal microscopy as in traditional FCS. With this system it is possible to detect concentrations as small as 1.5 x 10(5) E. coli per milliliter (2.5 x 10(-16) M). This concentration corresponds to an approximately 1.0-nM level of Rhodamine 6G dyes. A detailed analysis of the optical system is presented, and further improvements for the procedure are discussed.  相似文献   

16.
We describe a microfluidic mixer that is well-suited for kinetic studies of macromolecular conformational change under a broad range of experimental conditions. The mixer exploits hydrodynamic focusing to create a thin jet containing the macromolecules of interest. Kinetic reactions are triggered by molecular diffusion into the jet from adjacent flow layers. The ultimate time resolution of these devices can be restricted by premature contact between co-flowing solutions during the focusing process. Here, we describe the design and characterization of a mixer in which hydrodynamic focusing is decoupled from the diffusion of reactants, so that the focusing region is free from undesirable contact between the reactants. Uniform mixing on the microsecond time scale is demonstrated using a device fabricated by imprinting optical-grade plastic. Device characterization is carried out using fluorescence correlation spectroscopy (FCS) and two-photon microscopy to measure flow speeds and to quantify diffusive mixing by monitoring the collisional fluorescence quenching, respectively. Criteria for achieving microsecond time resolution are described and modeled.  相似文献   

17.
He Y  Wang G  Cox J  Geng L 《Analytical chemistry》2001,73(10):2302-2309
Overlap of multiple states or multiple species in a chemical system often creates a congested fluorescence spectrum that is difficult to interpret. The resolution of component spectra is essential for the understanding of the structure and dynamics of such multicomponent systems. In this paper, two-dimensional fluorescence correlation spectroscopy (2D FCS) is presented for the dissection of component spectra using the time correlation function. In 2D FCS, the time response of fluorescence intensity is collected at various wavelengths upon an external perturbation. The time correlation function is evaluated between wavelengths. A two-dimensional fluorescence correlation spectrum, or a plot of the correlation intensity as a function of two wavelength axes, resolves the overall spectrum into component spectra. The characteristics of the two-dimensional time correlation function are demonstrated in the frequency domain fluorescence spectroscopy in which the sinusoidally modulated excitation provides the external perturbation. Using 2D FCS, fine vibronic structures of the component fluorescence emission spectra were completely resolved from a strongly overlapped one-dimensional mixture spectrum. The existence of multiple microenvironments of a probe molecule in a biological system is evidenced by nonzero asynchronous correlation intensities. The corresponding spectra are retrieved from correlation analysis. Unlike traditional resolution methods in fluorescence spectroscopy based on statistical fitting of fluorescence decays, 2D FCS can resolve species whose fluorescence decays are linked by the rate constants in chemical reactions and species displaying multiexponential decay kinetics.  相似文献   

18.
Single-molecule fluorescence spectroscopy is used to study dye diffusion within organically modified silicate (ORMOSIL) films. ORMOSIL films are prepared from sols containing tetraethoxysilane and isobutyltrimethoxysilane in 2:1 and 1:9 molar ratios. Nile red and a new silanized form of nile red that can be covalently attached to the silicate matrix are used as fluorescent probe molecules. The number and rate of single molecules diffusing through these films increases dramatically with increasing film organic content. Autocorrelation of the fluorescence images yields a quantitative measure of the relative populations of fixed and diffusing species. Surprisingly, both "free" and silicate-bound nile red exhibit relatively facile translational motions. Single-molecule/single-point fluorescence correlation spectroscopy (FCS) is used to measure the dye diffusion coefficients in submicrometer-scale film regions. The most common diffusion coefficients for "free" and silicate-bound nile red molecules in the 1:9 films are 3.9 x 10(-10) and 1.6 x 10(-10) cm(2)/s, respectively. The unexpectedly rapid diffusion of silicate-bound nile red is attributed to the presence of liquidlike silicate oligomers in the films. A lower bound for the molecular weight of the oligomers is estimated at 2900. Bulk solution-phase FCS experiments performed on "free" and silicate-bound nile red species extracted into chloroform solutions provide valuable support for these conclusions. Comparison of the results derived from experimental and simulated time transients indicates film heterogeneity occurs on sub-100-nm-length scales and likely results from the presence of inorganic- and organic-rich domains.  相似文献   

19.
Berland K  Shen G 《Applied optics》2003,42(27):5566-5576
Fluorescence correlation spectroscopy (FCS) has become a powerful and sensitive research tool for the study of molecular dynamics at the single-molecule level. Because photophysical dynamics often dramatically influence FCS measurements, the role of various photophysical processes in FCS measurements must be understood to accurately interpret FCS data. We describe the role of excitation saturation in two-photon fluorescence correlation measurements. We introduce a physical model that characterizes the effects of excitation saturation on the size and shape of the two-photon fluorescence observation volume and derive a new analytical expression for fluorescence correlation functions that includes the influence of saturation. With this model, we can accurately describe both the temporal decay and the amplitude of measured fluorescence correlation functions over a wide range of illumination powers.  相似文献   

20.
When properly implemented, fluorescence correlation spectroscopy (FCS) reveals numerous static and dynamic properties of molecules in solution. However, complications arise whenever the measurement scenario is complex. Specific limitations occur when the detection region does not match the ideal Gaussian geometry ubiquitously assumed by FCS theory, or when properties of multiple fluorescent species are assessed simultaneously. A simple binary solution of diffusers, where both mole fraction and diffusion constants are sought, can face interpretive difficulty. In order to better understand the limits of FCS, this study systematically explores the relationship between detection-volume distortion, diffusion constants, species mole fraction, and fitting methodology in analyses that utilize a two-component autocorrelation model. FCS measurements from solution mixtures of dye-labeled protein and free dye are compared to simulations, which predict the performance of FCS under a variety of experimental circumstances. The results reveal a range of conditions necessary for performing accurate measurements and describe experimental scenarios that should be avoided. The findings also provide guidelines for obtaining meaningful measurements when grossly distorted detection volumes are utilized and generally assess the latent information contained in FCS datasets.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号