共查询到12条相似文献,搜索用时 0 毫秒
1.
2.
3.
Based on reasonable model hypotheses and the energy analysis of heat and mass transfer of air and water in a direct contact counter flow, a set of general equations that can describe the internal relationship between the state parameters of air and water and dimensionless parameters of transfer process are given. A method utilizing MATLAB to solve these general equations is also proposed. Calculations and analysis with the model of a cooling- dehumidifying process give a consistent result with that of previous experiment. A new method for designing equipment such as evaporating cooler and cooling tower, and for analyzing experiment data of heat and mass transfer of air and water in a direct contact counter flow can be derived from this study. 相似文献
4.
空气与水逆流直接接触热质交换模型计算及与实验比较 总被引:6,自引:0,他引:6
According to general equations deducted from a model of heat and mass transfer of air and water in direct contact counter flow reported in the author‘s previous work, the outlet parameters of air and water counter flow through a paper wet pad were calculated by using the MATLAB-software. Comparing the calculation results with experiment data of prior researchers, the deviation of calculated outlet air wet bulb temperature from experimental outlet air wet bulb temperature was less than 10%, the deviation of calculated outlet water temperature from experimental outlet water temperature was less thang 9%, and the deviation of calculated outlet air dry bulb temperature from experimental outlet air dry bulb temperature was less than 10% when NTUh was more than 0. 6. The deviation of calculated outlet air dry bulb temperature from experimental outlet air dry bulb temperature was more than 10% when NTUh was less than 0. 6. The model calculations were in good agreement with experiments and the general equations could be used to design evaporation cooling equipment, such as wet pad and so on. 相似文献
5.
6.
7.
Flow patterns upstream and downstream of a sudden-contraction cross-section in a vertical straight pipe were presented. By comparing with flow patterns in uniform cross-section vertical tubes, the effect of the sudden change in pipe diameter on flow patterns was analyzed. Flow pattern transition mechanisms were discussed and transition criteria for flow pattern transitions were deduced accordingly using the dimensional analysis. 相似文献
8.
受环境温度影响, 空冷机组夏季工况的运行背压高, 严重限制了机组的带负荷能力, 并影响机组的热经济性和安全性。分析了一种干-湿混合冷却系统, 将汽轮机排汽分流出一部分通过循环水冷却, 以降低机组夏季工况背压。建立了干-湿混合冷却系统对机组热经济性影响的数学模型, 并以某330 MW直接空冷机组为例揭示了机组背压和净功率随主蒸汽流量、湿冷分流量以及环境温度的变化规律。结果表明:主蒸汽流量为1120 t·h-1、湿冷分流量为175 t·h-1时, 机组出力从326.266 MW达到330 MW满负荷运行, 提高了3.734 MW, 背压由46.8 kPa下降到31.9 kPa, 机组的热耗率降低了110.9 kJ·(kW·h)-1, 发电标准煤耗率降低了4 g·(kW·h)-1。 相似文献
9.
10.
11.
研究了水分散性Kevlar纳米纤维的用量对天然橡胶/水分散性Kevlar纳米纤维复合材料力学性能及水刺激-力学响应的影响。结果表明,水分散性Kevlar纳米纤维可有效改善复合材料的力学性能,在其用量为20份(质量,下同)时,复合膜的储能模量达到30.30MPa,吸水后降低了57.26%,吸水前后的变化明显,说明添加20份水分散性Kevlar纳米纤维的复合材料具有最佳的力学性能及水刺激-力学响应。 相似文献
12.