首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
In bridge engineering, the three-dimensional behavior of a bridge system is usually reduced to the analysis of a T-beam section, loaded by an equivalent fraction of the applied live load, which is called the live load distribution factor (LDF). The LDF is defined in the both the AASHTO Standard Specifications and the LRFD Specifications primarily for concrete slabs and has inherent applicable limitations. This paper provides explicit formulas using series solutions for LDF of orthotropic bridge decks, applicable to various materials but intended for fiber-reinforced polymer (FRP) decks. The present formulation considers important parameters that represent the response characteristics of the structure that are often omitted or limited in the AASHTO Specifications. A one-term series solution is proposed based on the macroflexibility approach, in which the bridge system is simplified into two major components, deck and stringers. The governing equations for the two components are obtained separately, and the deflections and interaction forces are solved by ensuring displacement compatibility at stringer lines. The LDF is calculated as the ratio of the single stringer interaction force to the summation of total stringer interaction forces. To verify this solution, a finite-element (FE) parametric study is conducted on 66 simply supported concrete slab-on-steel girder bridges. The results from the series solution correlates well with the FE results. It is also illustrated that the series solution can be applied to predict LDF for FRP deck-on-steel girder bridges, by favorable comparisons among the analytical, FE, and testing results for a one-third-scale bridge model. The scale test specimen consists of an FRP sandwich deck attached to steel stringers by a mechanical connector. The series solution is further used to obtain multiple regression functions for the LDF in terms of nondimensional variables, which can be used for simplified design purposes.  相似文献   

2.
Filament-Wound Glass Fiber Reinforced Polymer Bridge Deck Modules   总被引:1,自引:0,他引:1  
The demand for the development of efficient and durable bridge decks is a priority for most of the highway authorities worldwide. This paper summarizes the results of an experimental program designed to study the behavior of an innovative glass fiber reinforced polymer (GFRP) bridge deck recently patented in Canada. The deck consisted of a number of triangular filament wound tubes bonded with epoxy resin. GFRP plates were adhered to the top and bottom of the tubes to create one modular unit. The experimental program, described in this paper, discusses the evolution of two generations of the bridge deck. In the first generation, three prototype specimens were tested to failure, and their performance was analyzed. Based on the behavior observed, a second generation of bridge decks was fabricated and tested. The performance was evaluated based on load capacity, mode of failure, deflection at service load level, and strain behavior. All decks tested exceeded the requirements to support HS30 design truck loads specified by AASHTO with a margin of safety. This paper also presents an analytical model, based on Classical Laminate Theory to predict the load-deflection behavior of the FRP decks up to service load level. In all cases the model predicted the deck behavior very well.  相似文献   

3.
This paper addresses the laboratory and field performance of multicellular fiber-reinforced polymer (FRP) composite bridge deck systems produced from adhesively bonded pultrusions. Two methods of deck contact loading were examined: a steel patch dimensioned according to the AASHTO Bridge Design Specifications, and a simulated tire patch constructed from an actual truck tire reinforced with silicon rubber. Under these conditions, deck stiffness, strength, and failure characteristics of the cellular FRP decks were examined. The simulated tire loading was shown to develop greater global deflections given the same static load. The failure mode is localized and dominated by transverse bending failure of the composites under the simulated tire loading as opposed to punching shear for the AASHTO recommended patch load. A field testing facility was designed and constructed in which FRP decks were installed, tested, and monitored to study the decks’ in-service field performance. No significant loss of deck capacity was observed after more than one year of field service. However, it was shown that unsupported edges (or free edges) are undesirable due to transitional stiffness from approach to the unsupported deck edge.  相似文献   

4.
In the United States alone, about 30% of the bridges are classified as structurally deficient or functionally obsolete. To alleviate this problem, a great deal of work is being conducted to develop versatile, fully composite bridge systems using fiber-reinforced polymers (FRPs). To reduce the self-weight and also achieve the necessary stiffness, FRP bridge decks often employ hollow sandwich configurations, which may make the dynamic characteristics of FRP bridges significantly different from those of conventional concrete and steel bridges. Due to the geometric complexity of the FRP sandwich panels, dynamic analyses of FRP bridges are very overwhelming and rarely reported. The present study develops an analysis procedure for the vehicle-bridge interaction based on a three-dimensional vehicle-bridge coupled model. The vehicle is idealized as a combination of rigid bodies connected by a series of springs and dampers. A slab FRP bridge, the No-Name Creek Bridge in Kansas, is first modeled using the finite-element method to predict its modal characteristics, then the bridge and vehicle systems are integrated into a vehicle-bridge system based on the deformation compatibility. The bridge response is obtained in the time domain by using an iterative procedure employed at each time step, considering the deck surface roughness as a vertical excitation to the vehicle. The bridge dynamic response and the calculated impact factors are compared between the FRP slab bridge and a corresponding concrete slab bridge. Finally, the applicability of AASHTO impact factors to FRP bridges is discussed.  相似文献   

5.
Fiber-reinforced polymer (FRP) composite materials are increasingly making their way into civil engineering applications. To reduce the self-weight and also achieve the necessary stiffness, sandwich panels are commonly used for FRP bridge decks. However, due to the geometric complexity of the FRP sandwich deck, convenient analysis and design methods for FRP bridge deck have not been developed. The present study aims at developing equivalent properties for a complicated sandwich panel configuration using finite-element modeling techniques. With equivalent properties, the hollowed sandwich panel can be transformed into an equivalent solid orthotropic plate, based on which deflection limits can be evaluated and designed. A procedure for the in-plane axial properties of the sandwich core has first been developed, followed by developing the out-of-plane panel properties for bending behavior of the panel. An application is made in the investigation of the stiffness contribution of wearing surface to the total stiffness of bridges with FRP panels. The wearing surface contribution is not usually accounted for in a typical design of bridges with traditional deck systems.  相似文献   

6.
No appropriate provisions from either AASHTO Standard (2002) or AASHTO LRFD (2004) bridge design specifications are available for the design of fiber-reinforced polymer (FRP)-deck-on-steel-superstructure bridges. In this research, a parametric study using the finite-element method (FEM) is conducted to examine two design issues concerning the design of FRP-deck-on-steel-superstructure bridges, namely deck relative deflection and load distribution factor (LDF). Results show that the strip method specified in AASHTO LRFD specification as an approximate method of analysis, can also be applied to FRP decks as a practical method. However, different strip width equations have to be determined by either FEM or experimental methods for different types of FRP decks. In this study, one such equation has been derived for the Strongwell deck. In addition, both FEM results and experimental measurements show that the AASHTO LDF equations for glued laminated timber decks on steel stringers provide good estimations of LDF for FRP-deck-on-steel-superstructure bridges. Finally, it is found that the lever rule can be used as an appropriately conservative design method to predict the LDF of FRP-deck-on-steel-superstructure bridges.  相似文献   

7.
We examine here the replacement of a deteriorated concrete deck in the historic Hawthorne Street Bridge in Covington, Va. with a lightweight fiber-reinforced polymer (FRP) deck system (adhesively bonded pultruded tube and plate assembly) to increase the load rating of the bridge. To explore construction feasibility, serviceability, and durability of the proposed deck system, a two-bay section (9.45 by 6.7?m) of the bridge has been constructed and tested under different probable loading scenarios. Experimental results show that the response of the deck is linear elastic with no evidence of deterioration at service load level (HS-20). From global behavior of the bridge superstructure (experimental data and finite- element analysis), degree of composite action, and load distribution factors are determined. The lowest failure load (93.6?kips or 418.1?kN) is about 4.5 times the design load (21.3?kips or 94?kN), including dynamic allowance at HS-20. The failure mode is consistent in all loading conditions and observed to be localized under the loading patch at the top plate and top flange of the tube. In addition to global performance, local deformation behavior is also investigated using finite-element simulation. Local analysis suggests that local effects are significant and should be incorporated in design criteria. Based on parametric studies on geometric (thickness of deck components) and material variables (the degree of orthotropy in pultruded tube), a proposed framework for the sizing and material selection of cellular FRP decks is presented for future development of design guidelines for composite deck structures.  相似文献   

8.
Moveable bridges in Florida typically use open steel grid decks due to weight limitations. However, these decks present rideability, environmental, and maintenance problems, as they are typically less skid resistant than a solid riding surface, create loud noises, and allow debris to fall through the grids. Replacing open steel grid decks with a lightweight fiber-reinforced polymer (FRP) deck can improve rideability and reduce maintenance costs, simultaneously satisfying the strict weight requirement for such bridges. In this investigation, a new low-profile, pultruded FRP deck system successfully passed the preliminary strength and fatigue tests per AASHTO requirements. Two two-span deck specimens were tested, one with the strong direction of the deck placed perpendicular to the supporting girders, whereas the other had a deck placed with 30° skew. This paper also describes a simplified finite-element approach that simulates the load–deformation behavior of the deck system. The results from the finite-element model showed a good correlation with the deflection and strain values measured from the tests.  相似文献   

9.
The sandwich plate system (SPS) is a relatively new bridge deck system that consists of steel face plates bonded to a rigid polyurethane core. The decks are thin, lightweight, and modular in design and can be tailored to numerous applications. This system provides an excellent alternative for the rapid construction and rehabilitation of bridge decks. With any new system, there exists some uncertainty in the design procedures as a result of the limited population for comparison. This paper presents the results of a finite-element parametric investigation of the lateral load distribution characteristics of SPS bridges. The parametric study primarily focuses on the influence of deck thickness on distribution behavior as compared to conventional reinforced concrete decks. Results from the study demonstrate that the inherent flexibility of a thin SPS deck yields larger distribution factors (up to 20%) than a typical reinforced concrete deck, but these distribution factors can still be conservatively estimated with current AASHTO LRFD methods. Additional comparisons indicate that the distribution behavior of SPS bridges can also be estimated with the equations proposed by the NCHRP 12-62 project.  相似文献   

10.
The use of glass fiber-reinforced polymer (GFRP) bridge decks is appealing for applications where minimizing dead load is critical. This paper describes fatigue and strength testing of two types of GFRP decks being considered for use in the retrofit of an aging steel arch bridge in Snohomish County, Washington, where a roadway expansion is necessary and it is desirable to minimize the improvements to the arch superstructure. Each test used a setup designed to be as close as practicable to what will be the in situ conditions for the deck, which included a 2% cross slope for drainage. The fatigue testing consisted of a single 116 kN (26 kip) load applied for 2 million cycles, which corresponds to an AASHTO HS-25 truck with a 30% impact factor, and the strength testing consisted of multiple runs of a monotonically applied minimum load of 347 kN (78 kips). Results from the fatigue testing indicated a degradation of the stiffness of both deck types; however, the degradation was limited to less than 12% over the duration of loading. Further, the results showed both deck types accumulated permanent deck displacement during fatigue loading and one deck type used a detail with poor fatigue performance. That detail detrimentally impacted the overall deck performance and caused large permanent deck deformations. It was also found that degradation of composite behavior between the deck and girders occurs during fatigue loading and should be included in design.  相似文献   

11.
Fiber reinforced polymer (FRP) composite bridge decks are gaining the attention of bridge owners because of their light self-weight, corrosion resistance, and ease of installation. Constructed Facilities Center at West Virginia University working with the Federal Highway Administration and West Virginia Department of Transportation has developed three different FRP decking systems and installed several FRP deck bridges in West Virginia. These FRP bridge decks are lighter in weight than comparable concrete systems and therefore their dynamic performance is equally as important as their static performance. In the current study dynamic tests were performed on three FRP deck bridges, namely, Katy Truss Bridge, Market Street Bridge, and Laurel Lick Bridge, in the state of West Virginia. The dynamic response parameters evaluated for the three bridges include dynamic load allowance (DLA) factors, natural frequencies, damping ratios, and deck accelerations caused by moving test trucks. It was found that the DLA factors for Katy Truss and Market Street bridges are within the AASHTO 1998 LRFD specifications, but the deck accelerations were found to be high for both these bridges. DLA factors for Laurel Lick bridge were found to be as high as 93% against the typical design value of 33%; however absolute deck stress induced by vehicle loads is less than 10% of the deck ultimate stress.  相似文献   

12.
A hybrid concept of composite sandwich panel with hybrid fiber-reinforced polymer (FRP)—steel core was proposed for bridge decks in order to not only improve stiffness and buckling response but also be cost efficient compared to all glass fiber-reinforced polymer (GFRP) decks. The composite sandwich bridge deck system is comprised of wrapped hybrid core of GFRP grid and multiple steel box cells with upper and lower GFRP facings. Its structural performance under static loading was evaluated and compared with the ANSYS finite element predictions. It was found that the presented composite sandwich panel with hybrid FRP-steel core was very efficient for use in bridges. The thickness of the hybrid deck may be decreased by 19% when compared with the all GFRP deck. The failure mode of the proposed hybrid deck was more favorable because of the yielding of the steel tube when compared with that of all GFRP decks.  相似文献   

13.
The research presented in this paper evaluates the flexural performance of bridge deck panels reinforced with 2D fiber-reinforced polymer (FRP) grids. Two different FRP grids were investigated, one reinforced with a hybrid of glass and carbon fibers and a second grid reinforced with carbon fibers only. Laboratory measured load-deflection, load-strain (reinforcement and concrete), cracking, and failure behavior are presented in detail. Conclusions regarding failure mode, limit-state strength, serviceability, and deflection compatibility relative to AASHTO mandated criteria are reported. Test results indicate that bridge decks reinforced with FRP grids will be controlled by serviceability limit state and not limit-state ultimate strength. The low axial stiffness of FRP results in large service load flexural deflections and reduced shear strength. In as much as serviceability limits design, overreinforcement is recommended to control deflection violation. Consequently, limit-state flexural strength will be compression controlled for which reduced service stresses or ACI unified compression failure strength reduction factors are recommended.  相似文献   

14.
Fiber-reinforced polymer (FRP) composite bridge deck panels are high-strength, corrosion resistant, weather resistant, etc., making them attractive for use in new construction or retrofit of existing bridges. This study evaluated the force-deformation responses of FRP composite bridge deck panels under AASHTO MS 22.5 (HS25) truck wheel load and up to failure. Tests were conducted on 16 FRP composite deck panels and four reinforced concrete conventional deck panels. The test results of FRP composite deck panels were compared with the flexural, shear, and deflection performance criteria per Ohio Department of Transportation specifications, and with the test results of reinforced concrete deck panels. The flexural and shear rigidities of FRP composite deck panels were calculated. The response of all panels under service load, factored load, cyclic loading, and the mode of failure were reported. The tested bridge deck panels satisfied the performance criteria. The safety factor against failure varies from 3 to 8.  相似文献   

15.
The MD 24 Bridge over Deer Creek in Harford County, Md., was one of the projects chosen by the Federal Highway Administration’s Innovative Bridge Research and Construction Program for bridge deck replacement by fiber-reinforced polymer (FRP) composites. A thorough discussion is presented on Maryland State Highway Administration’s first bridge rehabilitation project utilizing a FRP deck. The discussion includes design details, installation procedure, construction methods and in situ load testing with a wireless monitoring system. The research team installed a monitoring system to record the effects of live loads on the bridge system, including truss members, steel stringers, and plate action of the FRP deck. Finite-element models were also used in this phase. Dynamic effects of the FRP system, composite action between steel stringers and the FRP deck as well as the effective width and distribution factors of stringers were obtained and compared with the AASHTO specifications. Recommendations are also offered on improving the design details based on this experience.  相似文献   

16.
The use of fiber-reinforced polymer (FRP) reinforcement is a practical alternative to conventional steel bars in concrete bridge decks, safety appurtenances, and connections thereof, as it eliminates corrosion of the steel reinforcement. Due to their tailorability and light weight, FRP materials also lend themselves to the development of prefabricated systems that improve constructability and speed of installation. These advantages have been demonstrated in the construction of an off-system bridge, where prefabricated cages of glass FRP bars were used for the open-post railings. This paper presents the results of full-scale static tests on two candidate post–deck connections to assess compliance with strength criteria at the component (connection) level, as mandated by the AASHTO Standard Specifications, which were used to design the bridge. Strength and stiffness until failure are shown to be accurately predictable. Structural adequacy was then studied at the system (post-and-beam) level by numerically modeling the nonlinear response of the railing under equivalent static transverse load, pursuant to well-established structural analysis principles of FRP RC, and consistent with the AASHTO LRFD Bridge Design Specifications. As moment redistribution cannot be accounted for in the analysis and design of indeterminate FRP RC structures, a methodology that imposes equilibrium and compatibility conditions was implemented in lieu of yield line analysis. Transverse strength and failure modes are determined and discussed on the basis of specification mandated requirements.  相似文献   

17.
The design and construction of bridge systems with long-term durability and low maintenance requirements is a significant challenge for bridge engineers. One possible solution to this challenge could be through the use of new materials, e.g., fiber-reinforced polymer (FRP) composites, with traditional materials that are arranged as an innovative hybrid structural system where the FRP serves as a load-carrying constituent and a protective cover for the concrete. This paper presents the results of an experimental investigation designed to evaluate the performance of a 3/4 scale hybrid FRP-concrete (HFRPC) bridge deck and composite connection under sustained and repeated (fatigue) loading. In addition, following the sustained-load and fatigue portions of the experimental study, destructive testing was performed to determine the first strength-based limit state of the hybrid deck. Results from the sustained-load and fatigue testing suggest that the HFRPC deck system might be a viable alternative to traditional cast-in-place reinforced concrete decks showing no global creep behavior and no degradation in stiffness or composite action between the deck and steel girders after 2 million cycles of dynamic loading with a peak load of 1.26 times the scaled tandem load (TL). Furthermore, the ultimate strength test showed that the deck failed prior to the global superstructure at a load approximately six times the scaled TL.  相似文献   

18.
Due to the orthogonal elastic properties and significant two-way bending action, orthotropic plate theory may best be used to describe the behavior of concrete filled grid bridge decks. The current AASHTO LRFD specification employs an orthotropic plate model with a single patch load to predict live load moment in concrete filled grid bridge decks, which may not be conservative. This paper presents alternative equations to predict maximum moments, based on classical orthotropic plate theory, which include multiple patch loads, both the LRFD design truck and tandem load cases, and the two most common deck orientations. The predicted moments are verified through finite-element analyses.  相似文献   

19.
This paper presents results of an evaluation of the fatigue performance of a novel steel-free fiber-reinforced polymer (FRP)–concrete modular bridge deck system consisting of wet layup FRP–concrete deck panels which serve as both formwork and flexural reinforcement for the steel-free concrete slab cast on top. A two-span continuous deck specimen was subjected to a total of 2.36 million cycles of load simulating an AASHTO HS20 design truck with impact at low and high magnitudes. Quasistatic load tests were conducted both before initiation of fatigue cycling and after predetermined numbers of cycles to evaluate the system response. No significant stiffness degradation was observed during the first 2 million cycles of fatigue service load. A level of degradation was observed during subsequent testing at higher magnitudes of fatigue load. A fairly elastic and stable response was obtained from the system under fatigue service load with little residual displacement. The system satisfied both strength and serviceability limit states with respect to the code requirements for crack width and deflection.  相似文献   

20.
In addition to their high strength and light weight, fiber-reinforced polymer (FRP) composite reinforcing bars offer corrosion resistance, making them a promising alternative to traditional steel reinforcing bars in concrete bridge decks. FRP reinforcement has been used in several bridge decks recently constructed in North America. The Morristown Bridge, which is located in Vermont, United States, is a single span steel girder bridge with integral abutments spanning 43.90 m. The deck is a 230 mm thick concrete continuous slab over girders spaced at 2.36 m. The entire concrete deck slab was reinforced with glass FRP (GFRP) bars in two identical layers at the top and the bottom. The bridge is well instrumented at critical locations for internal temperature and strain data collection with fiber-optic sensors. The bridge was tested for service performance using standard truck loads. The construction procedure and field test results under actual service conditions revealed that GFRP rebar provides very good and promising performance.  相似文献   