首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 468 毫秒
1.
A new methodology for bromine stable isotope determination by continuous-flow isotope ratio mass spectrometry (CF-IRMS) was developed. The technique was tested on inorganic samples. Inorganic bromide was precipitated in the form of silver bromide by using silver nitrate in a standard methodology. Bromine stable isotope analysis was carried out on methyl bromide (CH3Br) after converting silver bromide to methyl bromide by reacting it with methyl iodide (CH3I). The system used in this study is an IsoPrime IRMS, with analytical capabilities of both dual-inlet and continuous-flow modes coupled with an Agilent 6890 GC equipped with a CTC Analytics CombiPAL autosampler. This new technique measures samples as small as 0.2 mg of AgBr (1 micromol of Br-). The bromine stable isotope analysis using continuous flow technology showed excellent precision and accuracy. The internal precision using pure methyl bromide gas is better than +/-0.03 per thousand (+/-SD); the external precision using seawater standard is better than +/-0.06 per thousand (+/-SD) for n = 12. Moreover, the sample analysis time is 16 min, as compared to 75 min needed in previous techniques. This allows for 50 samples to be analyzed in 1 day, as compared to 8 samples using the conventional techniques. A series of natural saline formation waters and brines from sedimentary and crystalline rock environments was measured by this new methodology to test the potential natural range of delta81Br. The bromine isotopic composition of the samples ranged from 0.00 to +1.80 per thousand relative to standard mean ocean bromide (SMOB). Initial trends and distinctive isotopic difference were noticed between crystalline shield brines and sedimentary formation brines.  相似文献   

2.
We report the first coupling of comprehensive two-dimensional gas chromatography (GC x GC) to online combustion isotope ratio mass spectrometry (C-IRMS). A GC x GC system, equipped with a longitudinally modulated cryogenic system (LMCS), was interfaced to an optimized low dead volume combustion interface to preserve <300 ms full width at half-maximum (fwhm) fast GC peaks generated on the second GC column (GC2). The IRMS detector amplifiers were modified by configuration of resistors and capacitors to enable fast response, and a home-built system acquired data at 25 Hz. Software was home-written to handle isotopic time shifts of less than one bin (40 ms) and to integrate peak slices to recover isotope ratios from cryogenically sliced peaks. The performance of the GC x GCC-IRMS system was evaluated by isotopic analysis of urinary steroid standards. Steroids were separated by a nonpolar GC1 column (30 m x 0.25 mm, 5% phenyl), modulated into multiple 4- or 8-s cryogenic slices by the LMCS, and then separated on a polar GC2 column (1 or 2 m x 0.1 mm, 50% phenyl). GC2 peak widths from a 1-m column averaged 276 ms fwhm. Steroid standard sliced peaks were successfully reconstructed to yield delta(13)C VPDB values with average precisions of SD(delta(13)C) = 0.30 per thousand and average accuracies within 0.34 per thousand, at 8 ng on column. Two steroids, coeluting in GC1, were baseline separated in GC2 and resulted in delta(13)C VPDB values with average precisions of SD(delta(13)C) = 0.86 per thousand and average accuracies within 0.26 per thousand, at 3 ng on column. Results from this prototype system demonstrate that the enhanced peak capacity and signal available in GC x GC is compatible with high-precision carbon isotope analysis.  相似文献   

3.
We describe our development of a CH4 preconcentration system for use with continuous-flow gas chromatograph combustion isotope ratio mass spectrometry (GC/C/IRMS). Precision of measurement of delta13C-CH4 is 0.05/1000 (1sigma) on multiple 60-mL aliquots of the same ambient air sample. The same front-end on-line CH4 preconcentration system allows us to measure deltaD of CH4 by gas chromatography IRMS when the combustion furnace is replaced with a pyrolysis oven (GC/P/IRMS). Precision of measurement for deltaD-CH4 is 1.5/1000 (1sigma) using 120 mL of ambient air based on multiple aliquots of the same air sample. These are the first reported measurements of atmospheric CH4 using GC/P/IRMS methodology. Each isotope analysis can be made much more rapidly (30-40 min) than they could using off-line combustion of an air sample (1-6 h) followed by conventional dual-inlet IRMS measurements (12-20 min), while requiring much less total volume and retaining a comparable level of precision and accuracy. To illustrate the capabilities of our preconcentration GC/C/IRMS system, we compare the results of measurement of 24 background air samples made using both GC/C/IRMS and conventional vacuum line/dual-inlet IRMS methodology. The air samples were collected on a shipboard air sampling transect made across the Pacific Ocean in July 2000 and are part of an ongoing atmospheric CH4 research program. The average difference between the two methods of IRMS analyses on these 24 samples is 0.01 +/- 0.03/1000 (95% confidence interval) for delta3C-CH4. These are the first measurements to be reported of air samples directly intercompared for delta13C-CH4 using both GC/C/IRMS and dual-inlet IRMS measurement methodology. Measurement of deltaD-CH4 of these air samples is also presented as an illustration of the ability of this system to resolve small isotopic differences in remote air. High-precision measurement of delta13C and deltaD of atmospheric CH4 made using our coupled preconcentration GC/IRMS system will greatly improve our ability to utilize isotopic data in understanding spatial and temporal changes in atmospheric CH4 and the biogeochemistry of its sources and sinks.  相似文献   

4.
We have developed a rapid and simple measurement system for both content and stable isotopic compositions (13C and 18O) of atmospheric CO, using continuous-flow isotope ratio mass spectrometry by simultaneously monitoring the CO+ ion currents at masses 28, 29, and 30. The analytical system consisted sequentially of a sample trapping port (liquid nitrogen temperature silica gel and molecular sieve 5A), a gas dryer, a CO purification column (molecular sieve 5A), a cryofocusing unit, and a final purification column using a GC capillary. Analytical precision of 0.2 per thousand for 13C and 0.4 per thousand for 18O can be realized for samples that contain as little as 300 pmol of CO within 40 min for one sample analysis. Analytical blanks associated with the method are less than 1 pmol. The extent of analytical error in delta13C due to mass-independent fractionation of oxygen in natural CO is estimated to be less than 0.3 per thousand. Based on this system, we report herein a kinetic isotopic effect during CO consumption in soil.  相似文献   

5.
A new, completely automated gas chromatography technique has been developed to separate the different gaseous compounds produced during underground coal gasification for their (13)C/(12)C and D/H isotope ratio measurements. The technique was designed for separation and collection of H(2), CO, CO(2), H(2)O, H(2)S, CH(4), and heavier hydrocarbons. These gaseous compounds are perfectly separated by the gas-phase chromatograph and quantitatively sent to seven combustion and collection lines. H(2), CO, CH(4), and heavier hydrocarbons are quantitatively oxidized to CO(2) and/or H(2)O. The isotopic analyses are performed by the sealed-tube method. The zinc method is used for reduction of both water and H(2)S to hydrogen for D/H analysis. Including all preparation steps, the reproducibility of isotope abundance values, for a quantity higher than or equal to 0.1 mL of individual components in a mixture (5 mL of gases being initially injected in the gas chromatograph), is ±0.1‰ for δ(13)C(PDB) and ±6‰ for δD(SMOW).  相似文献   

6.
This study investigates the emission characteristics of CO(2), SO(2) and NOx in the flue gas of coal combustion by varying the compositions and concentrations of feed gas (O(2)/CO(2)/N(2)) and the ratios of recycled flue gas. The differences between O(2)/recycled flue gas (O(2)/RFG) combustion and general air combustion are also discussed. Experimental results indicate that the maximum concentration of CO(2) in O(2)/CO(2) combustion system is 95% as the feed gas is 30% O(2)/70% CO(2). The average concentration of CO(2) in the flue gas of O(2)/CO(2) coal combustion system is higher than 90% and much higher than that of O(2)/N(2) coal combustion system. This high concentration of CO(2) is beneficial for the separation of CO(2) from the flue gas by adsorption or absorption technologies. The maximum concentration of CO(2) in O(2)/N(2) combustion system is only 34% at the feed gas 50% O(2)/50% N(2), the concentration of CO(2) is increased with the concentration of O(2) in feed gas. By O(2)/CO(2) combustion technology, higher concentration of SO(2) is produced as the feed gas is 30% O(2)/70% CO(2) or 40% O(2)/60% CO(2), while higher concentration of NOx is produced as the feed gas is 20% O(2)/80% CO(2) or 50% O(2)/50% CO(2). The mass flow rates of CO(2), SO(2) and NOx in the flue gas are all increased with the ratio of recycled flue gas except for the feed gas 20% O(2)/80% CO(2). The enhanced mass flow rates of air pollutants in such O(2)/RFG combustion system are also beneficial for improving the control efficiencies of air pollution control devices. By O(2)/N(2) combustion technology, higher concentrations of SO(2) and NOx are produced as the feed gas is 21% O(2)/79% N(2). The results also indicate that the formation of NOx in general air combustion system is higher than that in O(2)/RFG or O(2)/CO(2) combustion system.  相似文献   

7.
Amino acids are routinely derivatized using carbon-containing groups prior to gas chromatography continuous-flow isotope ratio mass spectrometry (GCC-IRMS). Derivative C contaminates analyte C because the entire derivatized compound is combusted to CO2. Correction procedures are required to extract the analyte isotope ratio. We present a method for reduction of six nonpolar amino acids to their corresponding amino alcohols, demonstrate a GC strategy to produce acceptable peak shapes from the resulting strongly H-bonding analytes, and present isotopic analysis for amino acids and their corresponding amino alcohols to evaluate any possible isotopic fractionation. Alanine, valine, leucine, isoleucine, methionine, or phenylalanine was reduced using NaBH4 in THF with I2 as an electrophile. Reactions were performed with 2 g of analyte to permit isotopic analysis by conventional elemental analysis-IRMS. All reactions were quantitative as assessed by IR spectra, melting points, and GC. Recovery from the reaction mixture was 60-84%. GC separation of a mixture of the six amino alcohols was achieved using a thick stationary-phase (5 microm) capillary column to avoid tailing due to hydrogen bonding to the walls of the fused-silica capillary. The reproducibility of GCC-IRMS determinations of amino alcohols averaged SD(613C) = 0.25 +/- 0.19%. The absolute differences between delta13C of amino acids measured by an elemental analyzer coupled to IRMS and amino alcohols measured by GCC-IRMS was delta613C = 0.14% and showed no general trend. Reactions performed with 2 mg of analyte yielded equivalent chromatograms. These data indicate that the reduction method does not induce isotopic fractionation and can be used for continuous-flow isotopic analysis to avoid addition of contaminating carbon.  相似文献   

8.
Sturm V  Noll R 《Applied optics》2003,42(30):6221-6225
Laser-induced breakdown spectroscopy (LIBS) was applied for simultaneous measurement of the elements C, H, N, and O in CO2-air, C3H8-CO2, and C3H8-N2 gas mixtures at atmospheric pressure. A single 7-mm-diameter aperture at the sample chamber was used for 1064-nm Nd:YAG laser irradiation and plasma signal output to an echelle spectrometer. Double-pulse laser bursts of approximately 8-ns pulse width (FWHM) and 250-ns interpulse separation were applied to increase the plasma signal. Calibration curves of the LIBS signal versus the partial pressure or the atomic abundance ratios were taken by dilution series in intervals that are relevant in the combustion of heptane (C7H16) near an equivalence ratio of 1.  相似文献   

9.
The crucial step in current concepts to interface isotope ratio mass spectrometry (IRMS) to gas chromatography (GC) is efficient solvent removal. This is due to the essential postcolumn conversion of the analytes into simple gases, which is performed by either combustion or pyrolysis. The capacity of this step merely suffices to convert the analytes. Already small amounts of solvent present in the respective furnace can cause severe damage. In conventional GC/IRMS interfaces, the solvent is removed after passage of the GC column. Either back-flushing or flow diversion is employed for this purpose. Both techniques necessitate the use of numerous components such as unions, tee pieces, valves, and capillary connections. Often this results in significant deterioration of the chromatographic resolution. In contrast, accurate GC/IRMS measurements require baseline separation of adjacent peaks. Moreover, maintenance of conventional interfaces may be tedious and time consuming, mostly because the numerous connections are prone to leakage. In order to avoid these drawbacks, we propose a concept to efficiently remove the solvent before passage of the GC column. It is based on the use of a cooled injection system operated in solvent vent mode, where the solvent elimination is supported by an auxiliary pump. Most unions and tee pieces thus can be removed. The chromatographic resolution is considerably enhanced. In particular, analysis of high-boiling and polar compounds can be improved. At the same time, the maintenance of the system is significantly facilitated. Under the chosen conditions, partial losses of low-boiling analytes during solvent elimination were not associated with significant isotope fractionation.  相似文献   

10.
Reeves M  Musculus M  Farrell P 《Applied optics》1998,37(28):6627-6635
We describe a confocal two-photon laser-induced fluorescence scheme for the detection of gaseous NO. Excitation from a simple YAG-pumped Coumarin 450 dye system near 452.6 nm was used to promote the two-photon NO(A (2)?(+), nu? = 0 ? X (2)?, nu? = 0) transition in the gamma(0, 0) band. Subsequent fluorescence detection in the range 200-300 nm permitted almost total rejection of elastic and geometric scatter of laser radiation for excellent signal/noise ratio characteristics. The goal of the research was to apply NO fluorescence to a relatively realistic limited optical access combustion environment. A confocal optical arrangement was demonstrated for single-point measurements of NO concentration in gas samples and in atmospheric-pressure flames. The technique is suitable for applications that offer only a single direction for optical access and when significant elastic scatter is present.  相似文献   

11.
A new method for the measurement of SI traceable carbon isotope amount ratios using a multicollector inductively coupled mass spectrometer (MC-ICPMS) is reported for the first time. Carbon (13)C/(12)C isotope amount ratios have been measured for four reference materials with carbon isotope amount ratios ranging from 0.010659 (delta(13)C(VPDB) = -46.6 per thousand) to 0.011601 (delta(13)C(VPDB) = +37 per thousand). Internal normalization by measuring boron (11)B/(10)B isotope amount ratios has been used to correct for the effects of instrumental mass bias. Absolute (13)C/(12)C ratios have been measured and corrected for instrumental mass bias and full uncertainty budgets have been calculated using the Kragten approach. Corrected (13)C/(12)C ratios for NIST RM8545 (Lithium Carbonate LSVEC), NIST RM8573 (L-Glutamic Acid USGS40), NIST RM8542 (IAEA-CH6 Sucrose) and NIST RM8574 (L-Glutamic Acid USGS41) differed from reference values by 0.06-0.20%. Excellent linear correlation (R = 0.9997) was obtained between corrected carbon isotope amount ratios and expected carbon isotope amount ratios of the four chosen NIST RMs. The method has proved to be linear within this range (from (13)C/(12)C = 0.010659 to (13)C/(12)C =0.011601), and therefore, it is suitable for the measurement of carbon isotope amount ratios within the natural range of variation of organic carbon compounds, carbonates, elemental carbon, carbon monoxide, and carbon dioxide. In addition, a CO2 gas sample previously characterized in-house by conventional dual inlet isotope ratio mass spectrometry has been analyzed and excellent agreement has been found between the carbon isotope amount ratio value measured by MC-ICPMS and the IRMS measurements. Absolute values for carbon isotope amount ratios traceable to the SI are given for each NIST RM, and the combined uncertainty budget (including instrumental error and each parameter contributing to Russell expression for mass bias correction) has been found to be < 0.1% for the four materials. The advantage of the method versus conventional gas source isotope ratio mass spectrometry measurements is that carbon isotope amount ratios are measured as C(+) instead of CO2(+), and therefore, an oxygen (17)O correction due to the presence of (12)C(17)O(16)O(+) is not required. Organic compounds in solution can be measured without previous derivatization, combustion steps, or both, thus making the process simple. The novel methodology opens new avenues for the measurement of absolute carbon isotope amount ratios in a wide range of samples.  相似文献   

12.
The analysis of the stable nitrogen isotope compositions of individual amino acid stereoisomers through the use of gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS) is presented. Nitrogen isotopic compositions of single amino acids or of their enantiomers is possible without the labor-intensive and time-consuming preparative-scale chromatographic procedures required for conventional stable isotope analysis. Following hydrolysis and derivatization, single-component isotope analysis is accomplished on nanomole quantities of each of the stereoisomers of an amino acid, utilizing the effluent stream of gas chromatographic separation. Nitrogen isotope fractionation is minimal during acylation of the amino acid, with no additional nitrogen being added stoichiometrically to the derivative. Thus, the isotopic composition of the nitrogen in the derivative is that of the original compound. Replicate stable nitrogen isotope analyses of 11 amino acids, and their trifluoroacetyl (TFA)/isopropyl (IP) ester derivatives, determined by both conventional isotope ratio mass spectrometry (IRMS) and GC/C/IRMS, indicate that the GC procedure is highly reproducible (standard deviations typically 0.3-0.4‰) and that isotopic differences between the amino acid and its TFA/IP derivative are, in general, less than 0.5‰.  相似文献   

13.
A multiparametric continuous-flow system for on-line monitoring of water based on ISFET sensors is described. The ISFETs used have silicon nitride as gate material, and the electrical contacts are placed on the back side of the chip. This is a technological improvement that allows for a more compact ISFET packaging and greatly increases the lifetime of the sensor compared with planar type ISFETs, since the electrical parts are separated from the chemical environment. A special probe has been designed in order to encapsulate and apply these ISFETs into the flow system. Further, a reference electrode based on standard Ag/AgCl technology has been constructed according to the ISFET probe design in order to integrate both sensors in the same flow-through cell. These probes can be easily replaced in the flow system and are made of cheap and easily mechanized materials. Using these flow-through sensors, a continuous-flow system for the determination of pH, NH(4)(+), Ca(2+), and NO(3)(-) in waters has been designed. The system configuration is based on a modular design (one setup for each parameter and a common sampling channel), which allows simple manipulation and maintenance as well as a good flexibility for different analytical requirements. A study of the system characteristics was performed by following the specifications for water monitoring. Under the conditions established for the flow system, a sampling rate of 20 h(-)(1) was obtained for each parameter, and long-term stabilities of at least 3 weeks of daily work for ISFET sensors and 5 months for the reference electrode have been achieved. The response performances obtained show the feasibility of the BSC ISFET probe use in continuous-flow monitoring.  相似文献   

14.
Isotope amount ratio measurements by electrospray ionization mass spectrometry show large systematic biases. Moreover, the signal ratio response can vary nonlinearly with respect to the amount ratio depending on the concentration of the analyte or coeluting matrix components, among other things. Since isotope dilution relies inherently on the linearity of response, accurate quantitation is then more difficult to achieve. In this study, we outline a method to eliminate the quantitation errors due to the effects of the nonlinear signal response. The proposed approach is a hybrid of the method of standard additions and isotope dilution allowing correction for nonlinear trend. As a proof of concept, determination of arsenobetaine content in fish tissue was performed using liquid chromatography coupled with a linear quadrupole ion trap (LTQ) Orbitrap mass spectrometer. The nonlinear isotope dilution method could, in principle, be applied to correct isotope ratio measurement biases in popular relative quantitation methods of biomolecules such as stable isotope labeling by amino acids in cell culture (SILAC), isotope-coded affinity tag (ICAT), or isobaric tags for relative and absolute quantification (iTRAQ).  相似文献   

15.
Here we describe an on-line method for measuring delta(37)Cl values of chloride bearing salts, waters, and organic materials using multicollector continuous-flow isotope ratio mass spectrometry (CF-IRMS). Pure AgCl quantitatively derived from total Cl in water, inorganic Cl salts, and biological samples was reacted with iodomethane in evacuated 10-mL stopper sealed glass vials to produce methyl chloride gas. A GV Instruments Multicollector CF-IRMS with CH(3)Cl optimized collector geometry was modified to accommodate a headspace single-sample gas injection port prior to a GC column. The GC column was a 2-m Porapak-Q packed column held at 160 degrees C. The resolved sample CH(3)Cl was introduced to the IRMS source in a helium stream via an open split. delta(37)Cl values were calculated by measurement of CH(3)Cl at m/z 52/50 and by comparison to a reference pulse of CH(3)Cl calibrated to standard mean ocean chloride. Sample CH(3)Cl analysis time was approximately 6 min. Injections of 40 microL of pure CH(3)Cl gas yielded a repeatability (+/-SD) of +/-0.06 per thousand for delta(37)Cl (n = 10). Combined GC and IRMS source linearity for CH(3)Cl was <0.2 per thousand/nA (V) peak height. External repeatability, based on processing of seawater and NaCl reference solutions, was better than +/-0.08 per thousand. The smallest sample for delta(37)Cl analysis by this method was approximately 0.2 micromol of Cl. Selected results from a river basin and biological samples study illustrate the potential of on-line chlorine isotope assays in environmental pollution studies.  相似文献   

16.
We present a rapid and selective method to increase the volatility of tyrosine and phenylalanine without adding derivative C for high-precision gas chromatography-continuous-flow isotope ratio mass spectrometry (GCC-IRMS) based on enzymatic decarboxylation to yield alkylamines and evaluated for 15N isotopic integrity. Purified tyrosine and phenylalanine were converted to tyramine and phenethylamine by tyrosine and phenylalanine decarboxylases, respectively. GC separation was achieved using a thick stationary phase (5-microm) capillary column. Recoveries were 95 +/- 2%. The reproducibility of delta15N of tyramine and phenethylamine measured by GCC-IRMS averaged SD(delta15N) = 0.33 per thousand. The absolute differences between delta15N of amino acids measured by elemental analyzer-IRMS and the alkylamines measured by GCC-IRMS was not significant. Phenethylamine and tyramine prepared from a mixture of 18 amino acids were extracted by ethanol with 95% recovery, and analysis yielded clean chromatograms and equivalent precision. These data indicate that enzymatic decarboxylation of phenylalanine and tyrosine is a convenient method to increase their volatility for continuous-flow isotopic analysis without introducing extraneous C or significant isotopic fractionation.  相似文献   

17.
Improved sensitivity in the analysis of stable chlorine isotopes of organochlorines (delta(37)Cl-OCl) has been established using sealed tube combustion in conjunction with thermal ionization mass spectrometry (TIMS). TIMS of chlorine isotopes was performed on <85 nmol of Cl with an achievable precision of <0.25 per thousand for pure inorganic chloride samples and 0.46 per thousand for chloride liberated from organochlorines (OCls). This makes possible significant reductions in the overall sample size requirement, as compared to the techniques of gas source stable isotope ratio mass spectrometry (SIRMS). Yields in excess of 99% were demonstrated in the dechlorination of <0.14 micromol 1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane (DDT), and the overall yield, including purification of liberated chloride, was 86-97%. The accuracy of TIMS in the measurement of chlorine isotopes derived from OCls was confirmed by analysis of a DDT sample previously analyzed with SIRMS.(9) Using the described method for TIMS, the DDT sample gave a bulk chlorine isotope ratio of delta(37)Cl -4.42 +/- 0.46 per thousand (1sigma). The reported value from SIRMS analysis is -4.34 +/- 0.25 per thousand, indicating the conformity of the two methods.  相似文献   

18.
This study investigated the effects of different calcium hydroxide (Ca(OH)(2)) addition methods on the potential for hydrogen chloride (HCl) formation in a simulated densified refuse-derived fuel (RDF-5) with single metal combustion system. These experiments were conducted at 850 degrees C with the Ca(OH)(2) spiked in the RDF-5 production or injection in the flue gas treatment system. The results indicated that the potential for HCl formation was decreased significantly by Ca(OH)(2) spiked in the RDF-5 production or injection in the flue gas treatment system. However, the Ca(OH)(2) injection method in the flue gas for HCl emission reduction was better than other method. According to the relationship between the HCl emission and amount of Ca(OH)(2) injected or spiked, it is interesting to find that when the Ca(OH)(2) injected or spiked ranged from 0% to 5%, the potential for HCl formation in the single metal combustion system decreases significantly with increasing Ca(OH)(2) injected or spiked ratio. A corresponding increase in the amount of CaCl(2) partitioned to the fly ash was observed. However, with the ratio of Ca(OH)(2) higher than 5%, the amount of HCl formation showed that no further significant variation occurred with increasing Ca(OH)(2) spiked ratio.  相似文献   

19.
Three different KNO3 salts with delta18O values ranging from about -31 to +54 per thousand relative to VSMOW were used to compare three off-line, sealed glass tube combustion methods (widely used for isotope studies) with a more recently developed on-line carbon combustion technique. All methods yielded roughly similar isotope ratios for KNO3 samples with delta18O values in the midpoint of the delta18O scale near that of the nitrate reference material IAEA-NO-3 (around +21 to +25 per thousand). This reference material has been used previously for one-point interlaboratory and intertechnique calibrations. However, the isotope ratio scale factors by all of the off-line combustion techniques are compressed such that they are between 0.3 and 0.7 times that of the on-line combustion technique. The contraction of the 6180 scale in the off-line preparations apparently is caused by O isotope exchange between the sample and the glass combustion tubes. These results reinforce the need for nitrate reference materials with delta18O values far from that of atmospheric O2, to improve interlaboratory comparability.  相似文献   

20.
The sediment concentrations of total petroleum hydrocarbons (TPHs), polyaromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), Pb and (207/206)Pb isotope ratios were measured in seven cores from the middle Clyde estuary (Scotland, UK) with an aim of tracking the late Anthropocene. Concentrations of TPHs ranged from 34 to 4386 mg kg(-1), total PAHs from 19 to 16,163 μg kg(-1) and total PCBs between less than 4.3 to 1217 μg kg(-1). Inventories, distributions and isomeric ratios of the organic pollutants were used to reconstruct pollutant histories. Pre-Industrial Revolution and modern non-polluted sediments were characterized by low TPH and PAH values as well as high relative abundance of biogenic-sourced phenanthrene and naphthalene. The increasing industrialization of the Clyde gave rise to elevated PAH concentrations and PAH isomeric ratios characteristic of both grass/wood/coal and petroleum and combustion (specifically petroleum combustion). Overall, PAHs had the longest history of any of the organic contaminants. Increasing TPH concentrations and a concomitant decline in PAHs mirrored the lessening of coal use and increasing reliance on petroleum fuels from about the 1950s. Thereafter, declining hydrocarbon pollution was followed by the onset (1950s), peak (1965-1977) and decline (post-1980s) in total PCB concentrations. Lead concentrations ranged from 6 to 631 mg kg(-1), while (207/206)Pb isotope ratios spanned 0.838-0.876, indicative of various proportions of 'background', British ore/coal and Broken Hill type petrol/industrial lead. A chronology was established using published Pb isotope data for aerosol-derived Pb and applied to the cores.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号