A. El Fadar  A. Mimet 《Solar Energy》2009,83(6):850-861
This article suggests a numerical study of a continuous adsorption refrigeration system consisting of two adsorbent beds and powered by parabolic trough solar collector (PTC). Activated carbon as adsorbent and ammonia as refrigerant are selected. A predictive model accounting for heat balance in the solar collector components and instantaneous heat and mass transfer in adsorbent bed is presented. The validity of the theoretical model has been tested by comparison with experimental data of the temperature evolution within the adsorber during isosteric heating phase. A good agreement is obtained. The system performance is assessed in terms of specific cooling power (SCP), refrigeration cycle COP (COPcycle) and solar coefficient of performance (COPs), which were evaluated by a cycle simulation computer program. The temperature, pressure and adsorbed mass profiles in the two adsorbers have been shown. The influences of some important operating and design parameters on the system performance have been analyzed.The study has put in evidence the ability of such a system to achieve a promising performance and to overcome the intermittence of the adsorption refrigeration systems driven by solar energy. Under the climatic conditions of daily solar radiation being about 14 MJ per 0.8 m2 (17.5 MJ/m2) and operating conditions of evaporating temperature, Tev = 0 °C, condensing temperature, Tcon = 30 °C and heat source temperature of 100 °C, the results indicate that the system could achieve a SCP of the order of 104 W/kg, a refrigeration cycle COP of 0.43, and it could produce a daily useful cooling of 2515 kJ per 0.8 m2 of collector area, while its gross solar COP could reach 0.18.  相似文献   

2.
A number of years of data on the global irradiation incident on a horizontal surface in Beer Sheva, Israel (lat. = 31°15′N, long. = 34°48′E, elevation 240 m) have been correlated. It is apparent from these data that this locale possesses a relatively high abundance of sunshine. The average cumulative annual irradiation is 6722MJ/m2 and the average daily irradiation is 18.43 MJ/m2. The percentage frequency of days possessing irradiation rates greater than 20 MJ/m2 is 46 per cent, whereas that possessing less than 10 MJ/m2d is 11.9 per cent. The percentage frequency of cloudy days (KT < 0.34) is low, 7.5 per cent, whereas that for clear days (KT > 0.65) is 29.2 per cent.  相似文献   

3.
Silica aerogel granulate material for thermal insulation and daylighting   总被引:9,自引:0,他引:9  
Silica aerogel granulate is a nanostructured material with high solar transmittance and low thermal conductivity. These properties offer exciting applications in building envelopes. One objective of the joint R&D project ISOTEG at ZAE Bayern was to develop and characterize a new glazing element based on granular silica aerogel. Heat transfer coefficients of less than 0.4 W/(m2 K) and a total solar energy transmittance of 35% for the whole glazing unit were achieved. The glazing has a thickness of less than 50 mm. Another application for granular silica aerogel is, for example, in solar collectors.The thermal properties of the glazing as well as the optical and thermal properties of the granular aerogels are presented here. The solar transmittance of a 10 mm packed bed of silica aerogel was 53% for semi-translucent spheres and 88% for highly translucent granulate. In our heat transfer experiments the gas pressure, external pressure load, temperature and gas filling were varied. The various thermal conductivity values measured for the glazing and collector applications were compared to the values calculated using two different packed bed models. For the gas-dependent measurements the intergranular voids in the granulate were 1.0 ± 0.1 mm before loading the packed bed, 0.3 ± 0.1 mm at an external load of 3.2 bar (3.2 × 105 Pa) and 0.6 ± 0.1 mm after release.A direct radiative conduction of λdirect = 4.5 ± 0.5 × 10−3 W m−1 K−1 was obtained.  相似文献   

4.
Based on solid-vapour intermittent absorption system, DORNIER a German Firm designed and fabricated a solar cooling unit, which utilizes thermal energy supplied by heat pipe vacuum tube solar collectors through thermosyphonic flow of water. The unit of 1.5 kWh/day cooling capacity uses ammonia as a refrigerant and IMPEX material as absorbent and does not have any moving part requiring no auxiliary energy. The IMPEX material (80% SrCl2 and 20% Graphite) has high heat and mass transfer coefficient as well as high absorption capacity. Detailed experiments were performed on a unit in Delhi under real field conditions followed by theoretical analysis. Theoretical maximum overall COP of the unit is 0.143, and it depends upon the climatic conditions. Under field conditions, it was found that if the maximum daytime ambient temperature was 30°C and night time temperature 20°C, it took three sunny days to freeze water in the cooling box. After the second day, the temperature inside the cooling box remained 1°C. The overall COP was found to be 0.081 only. The automatic control valve based on mechanical/thermal principles however has defects and the problem of corrosion of the sealings needs to be solved. In climates where day time temperatures are high (Delhi summer 43°C–47°C during the day, 30°C–35°C during the night) and solar radiation relatively low (4–5 kWh/m2d) because of pollution and sand in the atmosphere, it is most unlikely that pressure in the ammonia circuit can reach values at which ammonia vapours start to condense. The unit, needs to be redesigned for such conditions.  相似文献   

5.
A different cycle configuration is suggested in this work. Interesting improvement in performances is envisaged by applying the fixed bed adsorbers with the forced unsteady-state operation of periodic flow reversal to convective thermal wave cycle, which results in the so-called Periodic Reversal Forced Convective cycle. To describe process behavior for this kind of cycle with seven possible operating modes of flow reversal, a two-phase, one-dimensional model for the zeolite 13X-water pair is developed. Some important phenomena, such as the heat pipe effect, internal and external thermal regeneration etc., are discussed. The results of numerical simulations show that among all possible operating modes of flow reversal, only the mode of CCAA (switching the flow directions each phase duration) could improve the global performances of non-reversed flow operation, but others could not. Under the current conditions of cycle, the proposed CCAA cycle with heat exchanger regenerator could offer significant improvements in coefficient of performance (COP) over both the conventional cycle without flow reversal operation and existing convective thermal wave cycle with inert packed bed regenerator. The results of calculation also show that more than 1.7 of COPh, 0.9 of COPc and 125 W/kg adsorbent of specific cooling power (SCP) within this system could be possible. Analysis gives satisfactory explanation of these results.  相似文献   

6.
Heat transfer and hydrodynamic performances for nanofluids, Al2O3‐water and SiO2‐water, are numerically investigated with different nanoparticles’ volume fractions and the initial velocities in a fractal microchannel heat sink. The fractal microchannel is 100 μm × 100 μm in the inlet cross‐section, and the length at the 0th level is 2000 μm. A constant heat flux of 500 kW/m2 was applied to the bottom wall of the fractal microchannel heat sink. The heat transfer and hydrodynamic performances of different cases are discussed in terms of the mean heat transfer coefficient, mean base temperature, pressure loss, thermal resistance, friction factor f/f0, and COP/COP0. Results indicate that increasing the initial velocity and nanoparticles’ volume fraction lead to an enhanced heat transfer at the expense of pressure loss. Al2O3‐water has a higher mean heat transfer coefficient and pressure drop than that of SiO2‐water, a lower f/f0, mean base temperature, thermal resistance, and COP/COP0. Ultimately, as compared to pure water, the heat transfer coefficients of 4% Al2O3‐water increased by 7.53%, 7.80%, 8.00%, 8.14%, 8.16%, and 8.30%, and the pressure drops increased by 32.09%, 31.41%, 30.81%, 30.05%, 29.21%, and 28.58%, respectively, corresponding to the initial velocities by 4, 5, 6, 7, 8 and 9 m/s.  相似文献   

7.
In this paper, an absorption heat transformer (AHT) with falling film of aqueous LiBr solution inside vertical spiral tubes is installed and tested. The variations of coefficient of performance (COP), thermal efficiency (Eth ), and the heat transfer coefficient of the absorber at different falling film flow rates, hot water flow rates, and operating temperatures are investigated experimentally. The results demonstrated that the coefficient of performance and thermal efficiency of the system decrease with the increase in the flow rate of LiBr solution, and the influence of flow rate of hot water on COP and Eth is insignificant. The available COP in the experiments is higher than 0.4. The heat and mass transfer coefficients of the absorber increase with the increase of the flow rate of LiBr solution, up to 400W/m2/K and 0.013 kg/m2/s (temperature of waste heat is 90°C). The heat transfer coefficient of the absorber increases with the increase of the temperature of waste heat, and decreases with the increase of the cooling water temperature. Meanwhile, the computer code ABSIM (Absorption Simulation) is used to simulate the AHT systems, and the simulated results are compared with the experimental data.  相似文献   

8.
The performance of a solar driven CH4O-H2O combined ejector– absorption unit, operating in conjunction with intermediate temperature solar collectors in Athens, is predicted along the five months (May–September) in case of the unit working as heat pump in an industrial area. The operation of the unit and the related thermodynamics are simulated by suitable computer codes and the required local climatological data are determined by statistical processings over a considerable number of years. It is found that the heat gain factor varies in the range from 2.1330 to 2.4481 for the above period of time. The maximum HGF of about 2.4481 is obtained in July at 14.25 hrs with corresponding specific heat gain power 915 W/m2. The maximum Qgain of about 1086 W/m2 is obtained in June at 12.54 hrs with corresponding HGF 2.3572. Also the maximum value of HGF was estimated by correlation of three temperatures: generator temperature (85.0°C–97.2°C), condenser temperature (43.3°C–47.6°C) and evaporator temperature (12.6°C–25.4°C).  相似文献   

9.
The thermal losses of a monolithic low-density SiO2 aerogel tile (thickness d = 9 mm, density = 80 kg/m3) have been determined in our evacuable guarded hot plate system LOLA II. The measurements were performed for two values of boundary emissivities ( ≈ 0.05 and 0.9) under variation of temperature and of gas pressure for several types of gases. From our results we conclude that low-density silica aerogel tiles about 10 mm thickness provide excellent thermal insulation with overall loss coefficients k 0.7 W/(m2 · K) at ambient temperatures (10°C or 283 K) and pressures 10 mbar. Their use in window systems and covers for passive use of solar energy thus is extremely promising. From the change of thermal losses with gas pressure, a mean free path within the (evacuated) skeleton of about 120 nm can be derived.  相似文献   

10.
In the present work an attempt was made to study and examine some aspects of radiation climatology which are important in solar energy utilization. The yearly cumulative global radiation for Baghdad is 216 MJ/m2 per year, while the annual total of daily diffuse radiation at Baghdad is about 70.82 MJ/m2. The mean monthly values of clearness index KT present a maximum of 65.9% in August and a minimum value of 48.4% in January. The annual mean of daily global radiation and its spectral OG1, RG2 and RG8 at Baghdad is about, 18.03, 13.53, 10.86 and 9.36 MJ/m2, respectively. Over the year, the highest UV radiation were received during June and July (243 Wh/m2) and the lowest in December (79 Wh/m2). Furthermore, UV radiation constituted on average 3.25% of global radiation.  相似文献   

11.
In this study, a thermally driven adsorption cooling unit using natural zeolite–water as the adsorbent–refrigerant pair has been built and its performance investigated experimentally at various evaporator temperatures. The primary components of the cooling unit are a shell and tube adsorbent bed, an evaporator, a condenser, heating and cooling baths, measurement instruments and supplementary system components. The adsorbent bed is considered to enhance the bed’s heat and mass transfer characteristics; the bed consists of an inner vacuum tube filled with zeolite (zeolite tube) inserted into a larger tubular shell. Under the experimental conditions of 45 °C adsorption, 150 °C desorption, 30 °C condenser and 22.5 °C, 15 °C and 10 °C evaporator temperatures, the COP of the adsorption cooling unit is approximately 0.25 and the maximum average volumetric cooling power density (SCPv) and mass specific cooling power density per kg adsorbent (SCP) of the cooling unit are 5.2 kW/m3 and 7 W/kg, respectively.  相似文献   

12.
Theoretical efficiencies (η) and thermal behaviour of all-glass Evacuated Tube solar Collectors with an Internal Absorber Film (ETCIAF), i.e. the absorber film deposited in the inner surface of the inner tube, are compared and contrasted with the traditional design of all-glass Evacuated Tube solar Collectors with an External Absorber Film (ETCEAF), using the absorber film on the external surface of the inner tube. The values of η of the ETCIAF are unacceptably lower than that of ETCEAF for any particular value of the heat transfer coefficient (hb) for the annular space, except in the case of a highly leaky ETCEAF, with hb > 2.6 W/m2 K. However, it is shown that the use of a transparent conductive coating with moderately low emittance 0.1−0.25 on the outside of the absorber tube of ETCIAF can offer efficiences 0.75−0.63, respectively, for f = 0.1 °C m2/K, competing well (η = 0.76) with the ETCEAF design operating under best conditions (α = 0.91, = 0.05, and hb = 0.026 W/m2 K).  相似文献   

13.
Wind characteristics and wind energy resource potentials for Owerri, Nigeria are presented. These were evaluated using routine wind data measurements at a height of 10 m above ground level at the Lake Nwebere Campus, Federal University of Technology, Owerri between 1988 and 1992. The most prevailing wind is from the Southwest and the average wind speed and its variation are 2.80 and 0.81 m s−1, respectively.Accordingly, the maximum annual mean power density exploitable from the wind at this site is 7.66 ± 0.15 W m−2 out of the estimated available annual mean wind power density of 12.91 ± 0.26 W m−2. The annual mean energy density available in the wind was found to be 60.29 kW h m−2. Thus, the potential for year-round wind energy utilization in Owerri, Nigeria is rather low.  相似文献   

14.
Study of the climatology of global solar radiation is considered very useful for assessing the potential efficiency of systems designed for solar energy utilization. This paper explores some aspects of solar radiation climatology in Iraq. Analysis of the monthly averages global solar radiation and the general atmospheric transparency for the period 1971–1985 for three different climatological zones (Mosul, Baghdad, Nasiriyah) are discussed. The frequency distribution of daily clearness index for each station is determined using histograms of frequencies. The percentage number of days with solar radiation and sunshine duration values below a certain value is analyzed and discussed. The period of successive days having radiation less than 5 MJ/m2 · day−1 and 10 MJ/m2 · day−1 is examined and presented graphically.  相似文献   

15.
This study determines the glazing area in direct gain passive systems needed to ensure thermal comfort inside a building (room air temperature 20 ± 2°C). A 4 m × 4 m × 3 m single zone isolated house is analyzed in three different types of climates namely composite (8°C to 20°C, New Delhi), cold-cloudy (−2°C to 5°C, Srinagar), and cold-sunny (−14°C to −3°C, Leh). The analysis is based on the periodic solution of the heat conduction equations describing heat transmission in the building components, floor, walls, and roof, and the Fourier representation of the ambient temperature vnd the total solar radiation intercepted by the building envelope. Two types of construction are analyzed: the first type is a traditional construction with 22-cm-thick brick wall, plastered 15 mm on both the sides (U = 2.0 W m−2 K−1); and the second one is of the same type but with 10 cm of expanded polystyrene insulation on all the four walls and the roof (U = 0.31 W m−2 K−1). It is found that for traditional construction with U = 2.0 W m−2 K−1, the glazing U value has almost no effect on the room temperature even for large variation of the glazing area (10% to 40%, expressed in terms of percentage of floor area). For a well-insulated house (U = 0.31 W m−2 K−1), the glazing U value has no effect upon the room air temperature if the glazing area is small (less than 10%). The position of the insulation on the external surfaces is more effective in reducing large inroom air temperature. Finally, for an insulated house, we recommended glazing is 30%, 20%, and 10% for cold-sunny, cold-cloudy, and composite climates, respectively.  相似文献   

16.
Atmospheric turbidity parameters have been determined following Angstrom's method at three locations in Bangladesh namely, Dhaka city (23.7°N) and two rural locations, Haripur (26.03°N) and Sripur (24.11°N). The parameters were obtained from direct solar radiation data for specific spectral regions and for the whole spectrum as measured using a normal incidence pyrheliometer provided with cut-off glass filters. A considerable variation of Angstrom's turbidity parameters for Dhaka over the year was observed with a maximum value in March. The value for Sripur for the month of March was somewhat lower and the value for Haripur for the month of April was not much different from that of Dhaka. Linke turbidity factor TL was also determined using the new value of solar constant 1367 W/m2 for all three locations.  相似文献   

17.
The solar heating and nocturnal radiant cooling techniques are combined aiming at a novel solar heating and cooling panel (termed as SHCP) to be easily assembled as construction components for building roofing or envelope and also compatible with surroundings for its versatile coating colors, which can remove the double-skin mode from conventional solar equipment. SHCP has two functions for heating and cooling collecting. In this paper, the heating and cooling performances were analyzed in detail based on a small scale experimental system and effects of air gap and coatings were investigated. The results show that in sunny day of extreme cold January in Tianjin, China, the daily average heat-collecting efficiency is 39% with the maximum of 65%, while in sunny night during hot seasons the average cooling capacity can reach 87 W/m2. When two different coatings were sprayed on SHCP without air gap, its heating and cooling performances were all analyzed, the daily average heat-collecting efficiency was 39% and 27% with the maximum points of 65% and 49%, respectively, and the cooling capacity was almost the same of 30 W/m2 in January.  相似文献   

18.
Daily global insolation on a horizontal surface in Botswana is recorded continuously at several synoptic stations and at the University of Botswana's Physics Department. Over a number of years, daily total insolation on a tilted surface (β = −30°) was recorded at the Botswana Technology Centre. Hourly, and instantaneous direct normal, global, diffuse and UV-components are continuously recorded at the University of Botswana. All these measurements are done with standard EPLAB equipment.It is found out that the instantaneous direct normal radiation at Solar noon can be as high as 1150 W·m−2; and that at 30 min before sunset it can be above 600 W·m−2; and it can also be as high as 100 W·m−2 at sunset or sunrise moments (i.e. with half of the solar disk under the horizon).Daily direct normal solar radiation can exceed 45 MJ·m−2. Mean daily global radiation varies from 31 MJ·m−2 in December to 16 MJ·m−2 in June. Such big values of daily direct normal and global radiation are explained by low humidity and low turbidity.Cases of an anomalous phenomenon which lead to an abnormally big phase shift when direct normal radiation is increasing greatly after Solar noon are observed, and discussed. It is also found that when humidity is low and visibility is high, hourly Ig values recorded with a pyranometer can be less than Ibn (cosθz) + Id-values. This discrepancy could be quite common for regions where humidity and turbidity are low. The trend in the behaviour of the UV-component during the last five years is also analyzed and discussed. The conclusion is made that the ozone layer over Botswana is continuously being depleted.  相似文献   

19.
A theoretical analysis of the coefficient of performance COP was undertaken to examine the efficiency characteristics of the monomethylamine–water solutions for a single-stage absorption refrigeration machine, using low generator temperatures (60–80°C), which allows the use of flat plate solar collectors. The thermodynamic analysis considers both, basic and refined cycles. The refined absorption cycle included a sensible heat recover exchanger (that is a solution heat exchanger). The thermal coefficients of performance COPh for the basis cycle and COPSHE for the refined cycle were calculated using the enthalpies at various combinations, at the operating temperatures and concentrations. The flow ratio FR has been calculated as additional optimization parameter. Due to the relative low pressure and the high coefficients of performance, the monomethylamine–water solutions present interesting properties for their application in solar absorption cycles at moderate condenser and absorber temperatures (25–35°C), with temperatures in the evaporator from −10°C to 10°C which are highly usable for food product preservation and for air conditioning in rural areas.  相似文献   

20.
A truncated pyramid-type solar cooker is designed, fabricated and tested. The truncated pyramid geometry concentrates the incident light radiations towards the bottom and the glazing glass surface on the top facilitates the trapping of energy inside the cooker. One of the salient features of the proposed design is to completely eradicate the need for tracking the sun during cooking, as tracking of sun does not yield better performance. During testing, the highest plate stagnation temperature, under no-load condition, approached 140 °C and under full-load condition, water temperature inside the cooker reached 98.6 °C in 70 min. Two figures of merit, F1 and F2, were calculated and their values were 0.117° C m2/W and 0.467 °C l, respectively, meeting the standards prescribed by the Bureau of Indian Standards for solar box-type cookers. Minor modifications in design are recommended to achieve higher temperatures and reduce cooking times. The design also allows trays to be retained for use as a household dryer.  相似文献   