水平圆管临界热流密度实验研究 总被引:1,自引:1,他引:0
对水平圆管内低质量流速临界热流密度(CHF)进行了实验研究和分析。实验研究发现,水平流动圆管沸腾临界发生在圆管加热壁面顶部。通过对沸腾临界发生时圆管出口的质量含汽率和流型进行分析发现,本文研究的参数范围内沸腾临界时的出口含汽率高,流型为环状流,沸腾临界类型为干涸型(Dryout)。将经验公式预测值与实验结果进行比较发现,Bowring公式和Lookup table的预测值远大于CHF的实验值。导致此现象出现的主要原因为:Bowring公式和Lookup table是基于竖直流动CHF实验数据开发的模型,水平流动时在重力的作用下环状流液膜呈非均匀分布,顶部液膜干涸提前触发沸腾临界造成CHF值降低。 相似文献
8.
9.
10.
分析研究了在底部封闭矩形通道内逆流汽液两相流条件下的临界热流密度的发生机理。研究表明,临界热流密度与流入矩形通道内的最大下降液体流量相对应,并且临界热流密度可通过求解动量方程、包络线和能量方程得到。通过与日本数土幸夫建立的模型、经验关联式和实验数据比较,该模型可在精度±30 %范围内预测底部封闭矩形通道条件下的临界热流密度。 相似文献
11.
An investigation of flow characteristics and critical heat flux in vertical upward round tube 总被引:1,自引:0,他引:1
FAN Pu QIU Sui-Zheng JIA Dou-Nan 《核技术(英文版)》2006,17(3):170-176
Prediction of critical heat flux (CHF) in annular flow is important for the safety of once - through steam generator and the reactor core under accident conditions. The dryout in annular flow occurs at the point where the film is depleted due to entrainment, deposition, and evaporation. The film thickness, film mass flow rate along axial distribution, and CHF are calculated in vertical upward round tube on the basis of a separated flow modcl of annular flow. The theoretical CHF values are higher than those derived from experimental data, with error being within 30%. 相似文献
12.
13.
《Journal of Nuclear Science and Technology》2013,50(7):400-405
The heat transfer coefficient and slow burnout heat flux were measured for a stream-water annular dispersed upward flow under pressures up to 3.5 ata in an electrically heated vertical annular channel. An empirical equation was derived for the heat transfer coefficient as function of mass flow rate, steam quality and heat flux. The dominant mechanism of heat transfer to the annular dispersed two-phase flow is forced convection of liquid film on the heater surface even in the region of low steam quality (down to about 0.03). The observed slow burnout heat flux was near the point of intersection of the lines representing liquid film forced convective heat transfer and nucleate boiling heat transfer on the q vs. δT sat diagram. A dryout mechanism is proposed in which increasingly violent evaporation comes to impede the rewetting of the dry patches generated on the heater surface, which thus spread to cover the whole surface. A maximum value is observed in the slow burnout heat flux plotted against exit steam quality. This can be explained as the effect of heat removal by droplet exchange between liquid film and steam flow. 相似文献
14.
WU Ge-Ping QIU Sui-Zheng SU Guang-Hui JIA Dou-Nan LU Dong-Hua 《核技术(英文版)》2006,17(4):252-256
1 Introduction There are basically two classes of critical heat flux (CHF) situations: departure from nucleate boiling (DNB) and dryout (DO) [1]. DO is also sometimes known as burnout or departure from forced convective boiling in vapor-continuous flow. From the point of view of engineering, the CHF caused by the DO mechanism is of particular importance since boiling annular flow is one of the most common flow patterns in gas–liquid two-phase flow and occurs in a wide range of vapor qua… 相似文献
15.
The Film Dryout Analysis Code in Subchannels, FIDAS, has been developed with the main objective of predicting dryout and post-dryout heat transfer in a channel and in rod bundles. In FIDAS, two-phase flow consisting of continuous liquid film, continuous vapor and entrained droplets is modeled by a three-fluid, three-field representation of 12 field equations, i.e. three continuity, three energy and six momentum equations. FIDAS can predict dryout without any empirical CHF correlations by introducing annular flow modeling and the ‘film dryout criterion’. Experiments on film flow characteristics, subchannel flow and enthalpy distributions, dryout and post-dryout heat transfer in tubes and rod bundles were analyzed to demonstrate the performance of FIDAS. The predictions of FIDAS are in close agreement with the experiments. 相似文献