首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
OBJECTIVES: We assessed the safety and efficacy of stent placement in patients with poorly controlled hypertension and renal artery stenoses, which are difficult to treat with balloon angioplasty alone. BACKGROUND: Preliminary experience with stent placement suggests improved results over balloon angioplasty alone in patients with atherosclerotic renal artery stenosis. METHODS: Balloon-expandable stents were placed in 100 consecutive patients (133 renal arteries) with hypertension and renal artery stenosis. Sixty-seven of the patients had unilateral renal artery stenosis treated and 33 had bilateral renal artery stenoses treated with stents placed in both renal arteries. RESULTS: Angiographic success, as determined by quantitative angiography, was obtained in 132 (99%) of 133 lesions. Early clinical success was achieved in 76% of the patients. Six months after stent placement, the systolic blood pressure was reduced from 173 +/- 25 to 147 +/- 23 mm Hg (p < 0.001); the diastolic pressure from 88 +/- 17 to 76 +/- 12 mm Hg (p < 0.001); and the mean number of antihypertensive medications per patient from 2.6 +/- 1 to 2.0 +/- 0.9 (p < 0.001). Angiographic follow-up at a mean of 8.7 +/- 5.0 months in 67 patients revealed restenosis (>50% diameter narrowing) in 15 (19%) of 80 stented vessels. CONCLUSIONS: Renal artery stenting is an effective treatment for renovascular hypertension, with a low angiographic restenosis rate. Stent placement appears to be a very attractive therapy in patients with lesions difficult to treat with balloon angioplasty such as renal aorto-ostial lesions and restenotic lesions, as well as after a suboptimal balloon angioplasty result.  相似文献   

2.
It is unclear whether new devices such as directional coronary atherectomy (DCA) or Palmaz-Schatz stent implantation improve long-term outcomes compared with conventional balloon angioplasty in patients with stable angina and de novo coronary artery lesions of type A or type B except for complete occlusive lesions investigated by the American College of Cardiology/American Heart Association task force on percutaneous transluminal coronary angioplasty. A total of 146 patients with stable angina and simple lesions were assigned to either conventional balloon angioplasty (62 patients), DCA (50 patients), or Palmaz-Schatz implantation (34 patients). The acute results and late outcomes were assessed by coronary angiography. The results of the three procedures were similar with respect to procedural success and complications. Patients who underwent stenting or DCA had a larger immediate increase in the diameter of the lumen and a larger luminal diameter immediately after the procedure than those who underwent balloon angioplasty. At six months follow-up, the patients treated by stenting continued to have a larger luminal diameter and a lower rate of restenosis than those treated with balloon angioplasty (2.30 +/- 0.66 vs 1.85 +/- 0.83 mm, p < 0.005; 5.9% vs 29%, p < 0.05) and DCA (2.30 +/- 0.66 vs 1.90 +/- 0.96 mm, p < 0.05; 5.9% vs 24%, NS). The patients treated with balloon angioplasty had a smaller late loss than those treated with DCA or Palmaz-Schatz stent. The patients treated with DCA had a larger loss index than those treated with balloon angioplasty or Palmaz-Schatz stent. Stenting was a significant factor in decreasing the rate of restenosis by logistic regression analysis, compared with balloon angioplasty. The angiographic outcomes were better in patients who received a stent than in those who received other treatments. This study suggests that even lesions stable for treatment by balloon angioplasty and DCA can also be treated with Palmaz-Schatz stents.  相似文献   

3.
This study compares the immediate and long-term outcomes of a primary coronary stenting strategy with primary balloon angioplasty with stent bailout in the treatment of patients with acute myocardial infarction (AMI). One hundred forty-seven consecutive patients who underwent primary balloon angioplasty with stent bailout (n = 94) or primary stenting (n = 53) for AMI were clinically followed for 8.1 +/- 5.7 and 8.5 +/- 4.5 months, respectively. Immediate results, as well as in-hospital and long-term ischemic events (death, reinfarction, and repeat revascularization) were compared between both groups. Angiographic success was 91.5% in the balloon angioplasty group and 94% in the stent group. In-hospital and late follow-up combined ischemic events were 22 of 94 (23%) versus 0 of 53 (0%); p < 0.001 and 33 of 78 (42%) versus 13 of 53 (25%), p = 0.04 for the balloon angioplasty and stent groups, respectively. At 6 months, the cumulative probability of repeat target lesion revascularization was higher in the balloon angioplasty group (47% vs 18%, p = 0.0006) as was the probability of late target revascularization (36% vs 18%, p = 0.046); the cumulative event-free survival after 6 months was significantly lower in the balloon angioplasty group (44% vs 80%, p = 0.0001). This study demonstrates that a primary stent placement strategy in patients with AMI is safe, feasible, and superior to primary balloon angioplasty with stent bailout. Primary stenting results in a larger postprocedural minimal luminal diameter, a lower early and late recurrent ischemic event rate, and a lower incidence of target lesion revascularization at follow-up.  相似文献   

4.
BACKGROUND: There is controversy regarding the immediate and long-term effects of PTCA on the coronary flow reserve. METHODS AND RESULTS: A total of 54 patients with 1-vessel disease and normal left ventricular function were studied after balloon angioplasty (n=34) or stent implantation (n=20). Distal coronary blood flow velocity reserve (CFR) was defined as the ratio of adenosine-induced hyperemic versus baseline blood flow velocity with a 0.014-in Doppler guidewire. The relative CFR was defined as the ratio of the distal CFR and the reference CFR measured in the normal adjacent coronary artery. Hemodynamic and angiographic measurements were performed before and directly after balloon angioplasty or stent implantation and at 6-month follow-up. CFR after PTCA 相似文献   

5.
OBJECTIVES: This study reports on the initial experience with the Gianturco-Roubin flexible coronary stent. The immediate and 6-month efficacy of the device and the incidence of the complications of death, myocardial infarction, emergency coronary artery bypass surgery and recurrent ischemic events are presented. BACKGROUND: Abrupt or threatened vessel closure after coronary angioplasty is associated with increased risk of myocardial infarction, emergency coronary artery bypass graft surgery and in-hospital death. When dissection or prolapse of dilated plaque into the lumen is unresponsive to additional or prolonged balloon catheter inflation, coronary stenting offers a nonsurgical mechanical means to rapidly restore stable vessel geometry and adequate coronary blood flow. METHODS: From September 1988 through June 1991, 518 patients underwent attempted coronary stenting with the 20-mm long Gianturco-Roubin coronary stent for acute or threatened vessel closure after angioplasty. In 494 patients, one or more stents were deployed. Thirty-two percent of patients received stents for acute closure and 69% for threatened closure. RESULTS: Successful deployment was achieved in 95.4% of patients. Overall, stenting resulted in an immediate angiographic improvement in the diameter stenosis from 63 +/- 25% before stenting to 15 +/- 14% after stenting. Emergency coronary artery bypass graft surgery was required in 4.3% (21 of 493 patients). The incidence of in-hospital myocardial infarction (Q wave and non-Q wave) was 5.5% (27 of 493 patients). At 6 months, myocardial infarction was infrequent, occurring in 1.6% (8 of 493 patients). The incidence of in-hospital death was 2.2% (11 of 493 patients). Late death occurred in 7 patients (1.4%) and 34 patients (6.9%) required later bypass graft surgery. Complications included blood loss, primarily from the arterial access site, and subacute thrombosis of the stented vessel in 43 patients (8.7%). CONCLUSIONS: The early multicenter experience suggests that this stent is a useful adjunct to coronary angioplasty to prevent or minimize complications associated with flow-limiting coronary artery dissections previously correctable only by surgery. Although this study was not randomized, it demonstrated a high technical success rate and encouraging results with respect to the low incidence of emergency coronary artery bypass graft surgery and myocardial infarction.  相似文献   

6.
We evaluated the role of intravascular ultrasound (IVUS) in 16 patients with unprotected left main coronary artery (LMCA) stenting compared with 80 patients with other (non-LMCA) native coronary artery stenting and found that (1) additional high-pressure or larger size balloon dilations were more frequently performed in LMCA stenting than in non-LMCA stenting (p <0.05) and (2) after IVUS-guided stent implantation, minimum lumen area was > or = 9 mm2 in 88% of patients who underwent LMCA stenting and in 19% of those who underwent non-LMCA stenting (p <0.001). IVUS guidance may be a more important adjunctive imaging modality in the stenting of unprotected LMCA stenoses than in stenting of non-LMCA stenoses.  相似文献   

7.
The cost of in-hospital percutaneous transluminal coronary angioplasty (PTCA) has risen since the introduction of the coronary stent. Increased attention is now being given to the PTCA charges in Japan and a multicenter study is necessary with regard to in-hospital charges. To clarify the differences in in-hospital charges for PTCA with and without coronary stent [Stent Group and plain old balloon angioplasty (POBA) Group, respectively], we studied the PTCA charges of 352 patients in 6 hospitals. Age, male gender and extent of coronary artery disease were not different. The ratio of acute myocardial infarction ranged from 16% to 64% and that of coronary stenting ranged from 24% to 65% (p < 0.001). In-hospital charge ranged from 1.4 +/- 0.8 to 2.2 +/- 1.0 million yen (p < 0.0001). The procedural charge accounted for 53% to 75% of the in-hospital charge (p < 0.01). The in-hospital charge ranged from 1.6 +/- 0.7 to 3.3 +/- 1.6 million yen in the Stent Group, higher than the charge of 1.1 +/- 0.8 to 1.9 +/- 0.7 million yen in the POBA Group (p < 0.0001). There was a statistical difference in the number of balloon catheters used (1.1 +/- 0.4 to 2.1 +/- 0.9, p < 0.005) but not in the mean number of stents used (1.1 +/- 0.3 to 1.4 +/- 0.7). The procedural charge of the institutes with higher stenting rate (> 45%) seemed to be lower than that of the institutes with lower stenting rate (p < 0.02). In conclusion, there are large variation between institutions in PTCA charges, and in-hospital charges increased with the use of stents on introduction of the Diagnosis Related Group used in the United States. We should charge separately for coronary stenting and POBA. Despite any initial increase in the in-hospital charge for coronary stenting compared to POBA, successful stent implantation will result in a superior saving in procedural charges.  相似文献   

8.
Conventional balloon angioplasty treatment of aorto-ostial stenoses in native coronary arteries and saphenous vein grafts is associated with a low primary success rate, a high complication rate and a high incidence of restenosis. The short-term outcome of Palmaz-Schatz stent implantation in aorto-ostial lesions was compared with that of balloon angioplasty. Thirteen patients underwent stent implantation for 13 de novo lesions (four in the left main coronary trunk, two in the right coronary artery, seven in the vein graft) between January 1994 and December 1995. Fourteen patients underwent balloon angioplasty for 14 de novo lesions (five in the left main coronary trunk, four in the right coronary artery, five in the vein graft between January 1986 and April 1992. Both groups had similar clinical characteristics. Initial success was obtained in all patients in the stent group, compared with 71% of the balloon angioplasty group. Insufficient dilation was the main cause for such failure in the balloon angioplasty group. Baseline reference diameters were similar (3.40 +/- 0.65 mm in the stent group vs 3.36 +/- 0.42 mm in the balloon angioplasty group) and there was no difference in baseline minimal luminal diameter (1.41 +/- 0.74 vs 1.08 +/- 0.56 mm). Minimal luminal diameter was significantly greater in the stent group than in the balloon angioplasty group at both post-procedure and follow-up examinations (post: 3.36 +/- 0.58 vs 2.69 +/- 0.45 mm, p < 0.01; follow-up: 2.33 +/- 0.96 vs 1.52 +/- 0.68 mm, p < 0.05). There was no subacute occlusion in either group. The overall angiographic restenosis rate (> 50% stenosis) was lower in the stent group (17%) than in the balloon angioplasty group: the restenosis rates of native lesions were 0% in the stent group and 40% in the balloon angioplasty group; those of saphenous vein graft lesions were 33% in the stent group and 50% in the balloon angioplasty group. Although the number of patients was limited, these results suggest that Palmaz-Schatz stent implantation may be a safe and effective strategy for treating aorto-ostial lesions in both native coronary arteries and saphenous vein grafts.  相似文献   

9.
BACKGROUND: Autoperfusion balloons are available for the protection of the myocardium during balloon angioplasty. The aortic pressure is the driving force that delivers blood to the distal vessel during balloon inflation. Autoperfusion balloons can achieve sufficient flow rates in vitro. The use of these devices is recommended in high-risk patients in danger of haemodynamic collapse during balloon inflation. The quantity of the distal blood flow during balloon inflation in vivo is still unknown. OBJECTIVES: To measure distal coronary perfusion using Doppler guidewires during percutaneous transluminal coronary angioplasty (PTCA) with autoperfusion balloons. METHODS: Coronary flow velocity was measured with 0.014-inch Doppler guidewires bypassing the autoperfusion balloon in eight patients undergoing elective PTCA (degree of stenosis 74 +/- 7.2%). We used balloons with diameters of 3.0 and 3.5 mm. The coronary diameter at the location of the flow measurements was obtained by quantitative angiography in two planes. Coronary blood flow was calculated as the luminal area multiplied by the average peak flow velocity of the Doppler wire divided by 2. Coronary flow velocity reserve was measured before and after angioplasty by intracoronary injection of adenosine. RESULTS: Coronary blood flow was 35 +/- 11.6 ml/min before PTCA. During average inflation times of 4.6 +/- 0.9 min, coronary blood flow was 19 +/- 3.8 ml/min (P = 0.002) after withdrawing the guidewire in the autoperfusion balloon. Five minutes after angioplasty it increased to 42 +/- 13.5 ml/min (P < 0.001). Four patients had electrocardiographic changes during balloon inflation; three patients reported chest pain. One patient required a stent because of a local dissection. To achieve satisfactory angiographic results (residual stenosis 11 +/- 8.5%), we performed 2.1 +/- 0.78 inflations on average with a cumulative inflation time of 8.8 +/- 3.35 min. Coronary flow velocity reserve increased from 1.3 +/- 0.20 to 2.2 +/- 0.22 (P < 0.001). CONCLUSIONS: Using the autoperfusion balloon we measured a coronary blood flow during angioplasty of 56 +/- 10.3% of the distal perfusion before PTCA. In high-risk patients dependent on adequate coronary perfusion, autoperfusion balloons are not able to provide sufficient distal coronary blood flow during balloon inflation. In these patients active coronary or circulatory support devices are recommended.  相似文献   

10.
This study was designed to evaluate the alterations in doppler derived coronary blood flow velocities and flow reserve following rotational ablation. Changes in doppler derived coronary blood flow velocity variables have been valuable in assessing the physiological outcome following coronary balloon angioplasty. Rotational ablation's mechanism of plaque removal could alter distal vascular bed characteristics, and, as a result, intracoronary blood flow velocities and the coronary flow reserve. A 12-MHz doppler guidewire recorded intracoronary phasic velocities and coronary flow reserve (as assessed by the hyperemic response to adenosine [12-18 mcg intracoronary]) in 28 patients, before and after rotational ablation of 30 lesions. Adjunctive balloon angioplasty was performed in 27 of 28 patients (96%). Rotational ablation and adjunctive balloon angioplasty successfully reduced the lesion diameter (87 +/- 9% to 14 +/- 11%; P < 0.001). A significant increase in the mean distal average peak velocity (25 +/- 13 cm/sec, before; 47 +/- 22 cm/sec, after; P < 0.001), and decrease in the proximal to distal average peak velocity ratio, (2.1 +/- 1.3; to 1.2 +/- 0.4; P = 0.002) was recorded. The mean distal diastolic to systolic velocity ratio (before, 1.4 +/- 0.7; after, 1.6 +/- 0.8; P = 0.44) and the coronary flow reserve (before, 1.6 +/- 0.6; after, 1.5 +/- 0.5; P = 0.34) did not increase despite increases in distal velocities, following successful intervention. Doppler derived distal coronary blood flow velocities increased following rotational ablation and adjunctive balloon angioplasty, with resolution of transstenotic velocity gradient. Changes in distal phasic velocity pattern and coronary flow reserve, immediately after the intervention, were not useful in the assessment of the functional outcome and may be related to abnormalities in distal vascular bed vasoreactivity produced by rotational ablation.  相似文献   

11.
BACKGROUND: Diabetes is a major risk factor for restenosis after coronary balloon angioplasty. Recent studies have shown that coronary stenting significantly reduces restenosis compared with balloon angioplasty alone. However, limited information is available on the effect of coronary stenting in diabetic patients. METHODS AND RESULTS: We designed this study to analyze the effect of diabetes on restenosis in patients treated with either balloon angioplasty or coronary stenting who were enrolled in a 6-month angiographic follow-up program. Three hundred consecutive patients, 19% of whom were diabetics, who underwent coronary stent implantation during a single-vessel procedure on native coronary vessels and who had 6-month angiographic follow-up constituted the study group (stent group). Three hundred consecutive patients who underwent 6-month angiographic follow-up after single-vessel conventional balloon angioplasty served as control patients (balloon group). Preprocedural, postprocedural, and follow-up angiograms were analyzed with quantitative angiography. In the balloon group, the restenosis rate was almost twofold higher in diabetic than in nondiabetic patients (63% versus 36%; P=.0002) owing to both a greater late loss (0.79+/-0.70 versus 0.41+/-0.61 mm, respectively; P<.0001) and a higher rate of late vessel occlusion (14% versus 3%, respectively; P<.001). In the stent group, restenosis rates were similar in diabetics and nondiabetics (25% versus 27%, respectively). Furthermore, in the stent group, late loss (0.77+/-0.65 versus 0.79+/-0.57 mm, respectively) and the rate of late vessel occlusion (2% versus 1%, respectively) did not differ significantly between diabetic and nondiabetic patients. CONCLUSIONS: Although diabetics have increased rates of restenosis and late vessel occlusion after simple balloon angioplasty, they have the same improved outcome with coronary stenting that has been documented in nondiabetic patients.  相似文献   

12.
PURPOSE: To assess the accuracy of intraarterial measurement of transstenotic pressure gradients for the detection of hemodynamically suboptimal iliac angioplasty. METHODS: In 14 patients, referred for diagnostic angiography, mean pressure gradients in the aorta and iliac artery were obtained twice, using a double-sensor pressure catheter. Additional iliac measurements were performed during pharmacologically induced flow augmentation. Repeatability was assessed by calculation of the mean difference plus standard deviation (MD +/- SD) and repeatability coefficient (2 x SD). These results were extrapolated to 137 iliac angioplasty procedures with secondary stenting where there was a residual pressure gradient > 10 mmHg. RESULTS: MD +/- SD for repeated measurements at rest and during flow augmentation were 0 +/- 2 mmHg and 1 +/- 3 mmHg, respectively. Repeatability coefficients were 3 and 6 mmHg. Mean pressure gradients after hemodynamically insufficient angioplasty were 8 +/- 7 mmHg at rest and 17 +/- 5 mmHg following vasodilatation. Inaccurate pressure recordings may have led to inappropriate stent placement in less than 2.5%, and inappropriate denial of stent placement in less than 5% of the lesions. CONCLUSION: Variability of intraarterial pressure measurements has little consequence in the detection of hemodynamically significant stenosis after angioplasty.  相似文献   

13.
The EBI (BARD-XT, C.R. Bard, Murray Hill, NJ) stent is a new radiopaque balloon expandable coronary stent with high resistance to external radial forces. It does not shorten significantly with expansion and allows stent implantation in bifurcation lesions. A total of 28 EBI stents were implanted in 23 lesions in 21 patients. Indications for stent implantation were acute closure in 1, threatened closure in 15, and electively in 7 lesions. In 2 cases, the lesion involved a bifurcation where a stent was implanted in both vessels. All patients received aspirin and ticlopidine. No anticoagulant therapy was given. The stenting procedure was successful in 22 of 23 lesions. No complications occurred with the exception of 1 patient with a thrombotic reocclusion within 1 hr after stent implantation and 1 patient with a temporary occlusion of a side branch. The mean minimal luminal diameter (MLD) increased from 0.74+/-0.46 mm before balloon dilatation to 1.27+/-0.62 mm before stent implantation and 2.32+/-0.57 mm after stent implantation. Percent stenosis decreased from 71+/-19% before angioplasty to 46+/-25% after angioplasty to 5+/-8% after stent implantation. MLD at the time of follow-up angiography after 4 months was 1.98+/-0.77 mm and percent stenosis was 26+/-21%. Restenosis of more than 50% occurred in 2 lesions. In these lesions, a second percutaneous transluminal coronary angioplasty was performed. Advantages of this stent are its flexibility together with an acceptable radial strength as well as enabling radiopacity without obscuring the arterial lumen. Stenting of bifurcation lesions is possible.  相似文献   

14.
A high-speed rotational atherectomy was performed followed by adjunct directional atherectomy in 10 patients with symptomatic coronary artery disease and calcified target lesions and the results were evaluated using quantitative coronary arteriography and intravascular ultrasound. Target lesion calcium is common in obstructive coronary artery disease. High-speed rotational coronary atherectomy preferentially abrades noncompliant atherosclerotic plaque material, especially calcium, but often requires adjunct balloon angioplasty to achieve optimal lumen dimensions. Directional coronary atherectomy has limited efficacy in heavily calcified plaque; usually, it is a definitive primary procedure in large arteries with noncalcified target lesions. Neither of these devices alone is effective in treating calcified target lesions in large coronary arteries. Before intervention, after rotational and adjunct directional atherectomy, these measurements were obtained: quantitative coronary arteriographic measurements of minimal lumen diameter and percent diameter stenosis and intravascular ultrasound measurements of external elastic membrane, lumen, and plaque+media cross-sectional areas; percent cross-sectional narrowing; minimal lumen diameter; and target-lesion arc of calcium. With use of quantitative coronary arteriography, the preintervention minimal lumen diameter measured 0.7 +/- 0.4 mm, increased to 1.5 +/- 0.5 mm after rotational atherectomy (p = 0.0013) and to 2.5 +/- 0.3 mm after adjunct directional atherectomy (p < 0.001). The preintervention percent diameter stenosis measured 78 +/- 15%, decreased to 50 +/- 17% after rotational atherectomy (p = 0.0011), and to 17 +/- 11% (p < 0.001) after adjunct directional coronary atherectomy.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

15.
BACKGROUND: Intracoronary stenting reduces the rate of restenosis after angioplasty in patients with new coronary lesions. We conducted a prospective, randomized, multicenter study to determine whether intracoronary stenting, as compared with standard balloon angioplasty, reduces the recurrence of luminal narrowing in restenotic lesions. METHODS: A total of 383 patients who had undergone at least one balloon angioplasty and who had clinical and angiographic evidence of restenosis after the procedure were randomly assigned to undergo standard balloon angioplasty (192 patients) or intracoronary stenting with a Palmaz-Schatz stent (191 patients). The primary end point was angiographic evidence of restenosis (defined as stenosis of more than 50 percent of the luminal diameter) at six months. The secondary end points were death, Q-wave myocardial infarction, bypass surgery, and revascularization of the target vessel. RESULTS: The rate of restenosis was significantly higher in the angioplasty group than in the stent group (32 percent as compared with 18 percent, P= 0.03). Revascularization of the target vessel at six months was required in 27 percent of the angioplasty group but in only 10 percent of the stent group (P=0.001). This difference resulted from a smaller mean (+/-SD) minimal luminal diameter in the angioplasty group (1.85+/-0.56 mm) than in the stent group (2.04+/-0.66 mm), with a mean difference of 0.19 mm (P=0.01) at follow-up. Subacute thrombosis occurred in 0.6 percent of the angioplasty group and in 3.9 percent of the stent group. The rate of event-free survival at 250 days was 72 percent in the angioplasty group and 84 percent in the stent group (P=0.04). CONCLUSIONS: Elective coronary stenting was effective in the treatment of restenosis after balloon angioplasty. Stenting resulted in a lower rate of recurrent stenosis despite a higher incidence of subacute thrombosis.  相似文献   

16.
We evaluated acute and long-term clinical and angiographic results of elective Palmaz-Schatz coronary stent implantation for left anterior descending coronary artery (LAD) ostial stenosis in 23 consecutive patients. Eight patients had stable angina, 14 had unstable angina, and 1 had recent myocardial infarction. Sixteen patients had single-vessel, 5 had double-vessel, and 2 had triple-vessel disease. Clinical success without major complications (death, acute myocardial infarction, emergency coronary artery bypass grafting) was obtained in all cases and technical success in 20 cases (86.9%). After stenting, minimal lumen diameter increased from 1.05 +/- 0.45 mm to 2.89 +/- 0.52 mm (p < 0.001), and percent diameter stenosis decreased from 65.49% +/- 13.36% to 2.94% +/- 19.93% (p < 0.001). One case of subacute thrombosis and no major bleeding occurred. Twenty patients were followed-up for 6 months, during which no acute cardiac event (death, acute myocardial infarction) was observed. Eighteen patients were eligible for follow-up coronary angiography; restenosis (> or = 50% diameter stenosis) was observed in 4 (22.2%). Minimal lumen diameter was 1.77 +/- 0.55 mm, percent diameter stenosis was 39.66% +/- 17.62%, late loss was 1.01 +/- 0.69 mm, net gain was 0.79 +/- 0.55 mm, and loss index (late loss/acute gain) was 0.53 +/- 0.37. This study suggests that elective Palmaz-Schatz stent implantation may be a safe and successful treatment of LAD ostial lesions and provides a large increase in lumen diameter.  相似文献   

17.
We report a case of acute left main coronary artery subocclusion treated by stenting. The patient had a severe ostial left main coronary artery stenosis and after diagnostic coronary angiography developed subocclusion of the left main coronary artery, with TIMI 1 flow and life-threatening hemodynamic consequences. After two balloon dilatations had failed, a half Palmaz-Schatz stent (7 mm) was successfully deployed at the site of the lesion with immediate improvement of the angiographic and clinical picture. We claim that the placement of a half Palmaz-Schatz stent, hand-crimped on a high-pressure and non-compliance balloon, could provide a means for restoring adequate blood flow in patients who develop an important ischemia after diagnostic coronary angiography of a short, calcified left main coronary artery with severe ostial stenosis. Despite the satisfactory angiographic and clinical findings in these patients, the risk of restenosis and the presence of other multivessel diseases press us towards a more definitive surgical treatment.  相似文献   

18.
Therapies that inhibit intimal hyperplasia do not prevent restenosis after coronary artery balloon angioplasty, suggesting that additional mechanisms may be responsible for restenosis in humans. Using an intravascular ultrasound (Hewlett-Packard Sonos Intravascular Imaging System). 3.5F, 30-MHz (Boston Scientific) monorail imaging catheter, we studied 17 patients with clinical and angiographic restenosis at an average (mean +/- SD) of 7 +/- 6 months after balloon angioplasty (13 men age, 71 +/- 10 years; 12 left anterior descending coronary arteries, 4 right coronary arteries, and 1 left circumflex coronary artery) The lumen area (L.A), vessel wall area (VWA), and total cross-sectional area (CSA) within the external elastic lamina were measured at the restenosis site and at proximal and distal reference sites, which were defined as adjacent segments with the least amount of plaque. Consistent with coronary angiography findings, decreased LA at the restenotic site was detected in all 17 patients. The unique finding was that total CSA at the restenotic site was significantly decreased compared with both proximal and distal reference sites (10.1 +/- 2.4 versus 14.8 +/- 3.2 mm2 and 10.1 +/- 2.4 versus 13.8 +/- 3.1 mm2, respectively, P < .001), whereas VWA (intima plus media) was slightly increased at the angioplasty site compared with both proximal and distal reference sites (8.0 +/- 2.3 versus 7.6 +/- 2.3 mm2 and 8.0 +/- 2.3 versus 6.7 +/- 2.3 mm2, respectively, P = NS). Eighty-three percent of the loss in LA at the restenotic site was due to constriction of the total CSA, while the increase in VWA at the restenotic site accounted for only a 17% loss in LA. We then compared these results with the morphology of coronary artery segments in 14 patients without restenosis. These coronary artery segments had been previously treated with balloon angioplasty (7 +/- 5 months). Unlike that in restenotic lesions, the total CSA within the external elastic lamina at the sites of previous angioplasty was similar to that in distal and proximal reference sites (P = NS). Significant and consistent reduction in arterial CSA, with a minor increase in VWA, characterizes human coronary lesions that cause angiographic restenosis. These data suggest that in humans, "recoil" and/or vascular contraction with healing in response to balloon injury is a major contributor to restenosis after balloon angioplasty.  相似文献   

19.
OBJECTIVES: The purpose of the study was to assess the spectrum of coronary vasodilatory reserve values in patients with angiographically normal arteries who had atypical chest pain syndromes or remote coronary artery disease or were heart transplant recipients. BACKGROUND: The measurement of post-stenotic coronary vasodilatory reserve, now possible in a large number of patients in the cardiac catheterization laboratory, is increasingly used for decision making. Controversy exists regarding the range of normal values obtained in angiographically normal coronary arteries in patients with different clinical presentations. METHODS: Quantitative coronary arteriography was performed in 214 patients classified into three groups: 85 patients with chest pain syndromes and angiographically normal arteries (group 1); 21 patients with one normal vessel and at least one vessel with > 50% diameter lumen narrowing (group 2); and 108 heart transplant recipients (group 3). Coronary vasodilatory reserve (the ratio of maximal to basal average coronary flow velocity) was measured in 416 arteries using a 0.018-in. (0.04 cm) Doppler-tipped angioplasty guide wire. Intracoronary adenosine (8 to 18 micrograms) was used to produce maximal hyperemia. RESULTS: Coronary vasodilatory reserve was higher in angiographically normal arteries in patients with chest pain syndromes (group 1:2.80 +/- 0.6 [group mean +/- SD]) than in normal vessels in patients with remote coronary artery disease (group 2: 2.5 +/- 0.95, p = 0.04); both values were significantly higher than those in the post-stenotic segment of the diseased artery (1.8 +/- 0.6, p < 0.007). Coronary vasodilatory reserve in transplant recipients (group 3) was higher than that in the other groups (3.1 +/- 0.9, p < 0.05 vs. groups 1 and 2) as a group and for individual arteries. When stratified by vessel, coronary vasodilatory reserve was similar among the left anterior descending, left circumflex and right coronary arteries. There were no differences between coronary vasodilatory reserve values on the basis of gender for patients with coronary artery disease and transplant recipients. In group 1 (chest pain), there was a trend toward higher coronary vasodilatory reserve in men than in women (2.9 +/- 0.6 vs 2.7 +/- 0.6, p = 0.07). CONCLUSIONS: These findings identify a normal reference range for studies assessing the coronary circulation and post-stenotic coronary vasodilatory reserve in patients with and without coronary artery disease encountered in the cardiac catheterization laboratory.  相似文献   

20.
BACKGROUND: Treatment of stenosis in saphenous-vein grafts after coronary-artery bypass surgery is a difficult challenge. The purpose of this study was to compare the effects of stent placement with those of balloon angioplasty on clinical and angiographic outcomes in patients with obstructive disease of saphenous-vein grafts. METHODS: A total of 220 patients with new lesions in aortocoronary-venous bypass grafts were randomly assigned to placement of Palmaz-Schatz stents or standard balloon angioplasty. Coronary angiography was performed during the index procedure and six months later. RESULTS: As compared with the patients assigned to angioplasty, those assigned to stenting had a higher rate of procedural efficacy, defined as a reduction in stenosis to less than 50 percent of the vessel diameter without a major cardiac complication (92 percent vs. 69 percent, P<0.001), but they had more frequent hemorrhagic complications (17 percent vs. 5 percent, P<0.01). Patients in the stent group had a larger mean (+/-SD) increase in luminal diameter immediately after the procedure (1.92+/-0.30 mm, as compared with 1.21+/-0.37 mm in the angioplasty group; P<0.001) and a greater mean net gain in luminal diameter at six months (0.85+/-0.96 vs. 0.54+/-0.91 mm, P=0.002). Restenosis occurred in 37 percent of the patients in the stent group and in 46 percent of the patients in the angioplasty group (P=0.24). The outcome in terms of freedom from death, myocardial infarction, repeated bypass surgery, or revascularization of the target lesion was significantly better in the stent group (73 percent vs. 58 percent, P = 0.03). CONCLUSIONS: As compared with balloon angioplasty, stenting of selected venous bypass-graft lesions resulted in superior procedural outcomes, a larger gain in luminal diameter, and a reduction in major cardiac events. However, there was no significant benefit in the rate of angiographic restenosis, which was the primary end point of the study.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号