共查询到20条相似文献,搜索用时 15 毫秒
1.
Dale D. McClure Ai Chia Lee John M. Kavanagh David F. Fletcher Geoffrey W. Barton 《化学工程与技术》2015,38(1):44-52
The impact of sparger design and surfactant addition on the oxygen transfer rate in a bubble column was examined. Additionally, measurements were also made of the holdup and bubble size distribution, allowing both the interfacial area for mass transfer and the liquid film mass transfer coefficient to be determined for a range of industrially relevant superficial velocities. It was found that for the velocity range examined changes in the superficial velocity had a minimal impact on the observed value of liquid film mass transfer coefficient. In contrast, addition of both hydrophilic and hydrophobic surface‐active compounds led to an approximately threefold reduction in liquid film mass transfer coefficient. 相似文献
2.
The holdup and bubble size distribution (BSD) in bubble columns using both air/water and an industrially relevant air/fermentation media system are investigated. It was found that the BSD in the air/fermentation media system was quite narrow and did not change with height. In contrast, the BSD in the air/water system varied considerably with height depending on the sparger design used. Holdup measurements were also performed for different superficial velocities. The holdup in the air/fermentation media system was greater than that for the air/water system, a result attributed to the presence of surface‐active compounds in the fermentation media. 相似文献
3.
Development of a CFD Model of Bubble Column Bioreactors: Part Two – Comparison of Experimental Data and CFD Predictions 下载免费PDF全文
The application of computational fluid dynamics (CFD) as a tool to simulate bubble column bioreactors is investigated. A three‐dimensional model utilizing the Euler‐Euler approach is evaluated. The role of various terms, i.e., lift, drag, bubble‐induced turbulence, and volume fraction correction terms for drag, is determined. Good agreement between experimental data and simulation results was obtained by means of a single‐bubble size model provided that bubble‐induced turbulence and the reduction in drag due to the presence of other bubbles were taken into account. 相似文献
4.
Computational Fluid Dynamics (CFD) is used to compare the hydrodynamics and mass transfer of an internal airlift reactor with that of a bubble column reactor, operating with an air/water system in the homogeneous bubble flow regime. The liquid circulation velocities are significantly higher in the airlift configuration than in bubble columns, leading to significantly lower gas holdups. Within the riser of the airlift, the gas and liquid phases are virtually in plug flow, whereas in bubble columns the gas and liquid phases follow parabolic velocity distributions. When compared at the same superficial gas velocity, the volumetric mass transfer coefficient, kLa, for an airlift is significantly lower than that for a bubble column. However, when the results are compared at the same values of gas holdup, the values of kLa are practically identical. 相似文献
5.
6.
Elena M. Cachaza M. Elena Díaz Francisco J. Montes Miguel A. Galán 《Chemical engineering science》2011,66(18):4047
In this paper, a study on the global gas holdup and hydrodynamic flow regimes developed in a partially aerated bubble column at variable air superficial velocities (UG) in the presence of positive and negative surfactants is presented. According to the results obtained, despite the different liquid phase properties variation caused by the presence of positive (alcohols) and negative (electrolytes) surfactants, both reduce coalescence and the effect in the gas holdup (εG) is equivalent: it increases with the surfactant concentration (C) but only when the (C/Ct) ratio is clearly above 1, being Ct the transition concentration. Contrary to the results obtained for totally aerated bubble columns, for lower values of the (C/Ct) ratio, the holdup remains practically invariable. Considering the crucial role that C and Ct play in the resulting εG, a new prediction equation for εG accounting for the ratio (C/Ct) and UG is presented and its performance for both types of surfactants validated. Additionally, visual and wall pressure fluctuations studies reveal that the vortical flow (VF), characterized by an oscillating bubble plume, prevails in ultrapure water (UPW) but results destabilized in the presence of surfactants. This destabilization results in an evolution to a pseudo-steady flow regime, the double cell turbulent flow regime (DCTF), characterized by a quasi-static bubble jet, located at the column centerline that determines the appearance of two static symmetrical vortices 相似文献
7.
A new invasive sensing probe for the measurement of local phase holdups in two‐ and three‐phase reactors is described. The local gas and solids holdups in a bubble column with a volume of V = 2 m3 at varying operating conditions (gas velocity, sparger design, solids content and density) are measured by means of differential pressure measurement in combination with either time domain reflectometry or electrical conductivity measurement. The phase distribution profiles at two‐ and three‐phase operating conditions are described. The influence of the sparger design on the shape of these profiles, the influence of the solid phase on the gas distribution, the solids distribution and the gas‐stow effect above the sparger because of a dense particle layer are capable of experimental proof for the first time. 相似文献
8.
Computational fluid dynamics (CFD) was used to simulate the effect of sparger construction in gas holdup and liquid axial velocity in a shallow bubble column reactor for the air‐water system. Model parameters were evaluated in 2‐ and 3‐D simulations by using a two‐fluid model and the standard k‐? turbulence model. The Eulerian‐Eulerian approach was employed to predict the height of column that is affected by the sparger. It was found that increasing the number of orifices in the sparger increases the total gas holdup. Moreover, each orifice causes an increase in the circulation and mixing of liquid in the column. The results of the simulations follow the trends observed in the findings of Dhotre and Joshi [1]. 相似文献
9.
The hydrodynamic behavior of a single‐stage tapered bubble column using an air‐water two‐phase system has been studied. The experimental results indicate that the holdup increases with increasing superficial gas velocity and bubble slip velocity, while it remains constant with increasing superficial liquid velocity. The gas flow rate has a subtle effect on pressure drop owing to the dynamic pressure recovery stemming from the increase in flow area in the axial direction. The results further suggest that the tapered bubble column shows higher holdup with lower energy dissipation than the conventional bubble columns under similar hydrodynamic conditions. The experimental values of the holdup are in excellent agreement with the well‐known Akita and Yoshida correlation available in the existing literature. Also, the performance of the tapered system has been shown to be much better than that of conventional columns under similar conditions in water/alkaline scrubbing of fly ash and SO2 either alone or in combination. 相似文献
10.
SDBS和正丁醇及NaCl对鼓泡塔中氧传质的影响 总被引:1,自引:0,他引:1
表面活性剂和醇类物质的存在很大程度上可以改变水中氧的传质效率。本实验在内径15 cm的曝气塔中研究了阴离子表面活性剂十二烷基苯磺酸钠(SDBS)和正丁醇及NaCl对KLa的影响。结果发现,SDBS的传质系数在0.1 mmol/L以内急剧下降,而后随着浓度的增大,传质系数逐渐上升。而正丁醇对氧传质系数的影响则一直呈现上升趋势。通过添加NaCl,发现SDBS在NaCl浓度低于0.2%(质量百分数)时KLa随NaCl浓度的增加而增大;在NaCl浓度高于0.3%时,KLa随NaCl浓度升高下降明显。而固定浓度的正丁醇的KLa随NaCl的浓度改变变化不甚显著。虽然SDBS和正丁醇都可以对传质产生影响,但是效应却不一样,表明机理也不相同。 相似文献
11.
An apparatus where individual bubbles are kept stationary in a downward liquid flow was adapted to simultaneously (i) follow mass transfer to/from a single bubble as it inevitably gets contaminated; (ii) follow its shape; and (iii) periodically measure its terminal velocity. This apparatus allows bubbles to be monitored for much longer periods of time than does the monitoring of rising bubbles. Thus, the effect of trace contaminants on bubbles of low solubility gases, like air, may be studied.Experiments were done with air bubbles of 1-5 mm initial equivalent diameter in a water stream. The partial pressure of air in the liquid could be manipulated, allowing bubbles to be either dissolving or kept at an approximately constant diameter.Both drag coefficient and gas-liquid mass transfer results were interpreted in terms of bubble contamination kinetics using a simplified stagnant cap model. Drag coefficient was calculated from stagnant cap size using an adaptation of Sadhal and Johnson's model (J. Fluid Mech. 126 (1983) 237).Gas-liquid mass transfer modelling assumed two mass transfer coefficients, one for the clean front of the bubble, the other for the stagnant cap. Adjusted values of these coefficients are consistent with theoretical predictions from Higbie's and Frössling's equations, respectively. 相似文献
12.
The Kolmogorov entropy (KE) algorithm was applied successfully to gas holdup fluctuations measured in a 0.102 m I.D. stainless steel bubble column equipped with a perforated plate distributor (19 holes ?? 1 mm). Nitrogen was used as the gas, while both 1‐butanol and gasoline were used as liquids. 1‐Butanol was aerated at pressures, P = 0.1 and 0.5 MPa, whereas gasoline was aerated at P = 0.1 and 0.2 MPa. Based on the peaks in the KE values under the pressures examined in both liquids, the boundaries of the following five regimes were identified: bubbly flow, first transition, second transition, coalesced bubble (4‐region flow) and coalesced bubble (3‐region flow). As the pressure increases to P = 0.5 MPa in 1‐butanol, all four transition velocities shift to higher superficial gas velocity, uG. In addition, in gasoline at P = 0.2 MPa and uG ≤ 0.017 m s–1, the existence of a chain bubbling regime was detected, whereas in 1‐butanol at P = 0.5 MPa and uG ≤ 0.02 m s–1, both laminar and turbulent chain bubbling subregimes were identified. It was found that in 1‐butanol under ambient pressure, the second and fourth transition velocities occur earlier than in gasoline. 相似文献
13.
Simultaneous measurements of liquid velocity by laser Doppler velocimetry and bubble velocity, diameter, and void fraction by a double optical probe are performed in a bubble column to study the influence of the void fraction on the relative velocity of a swarm of gas bubbles. Bubble diameters db vary from 2 to 10 mm and local void fractions αloc can reach 35%. It is found that, for αloc<15%, the relative bubble velocity is determined by the hindrance effect and consequently decreases with the void fraction. Beyond this critical value, the aspiration of bubbles in the wake of the leading ones dominates the hindrance effect and the relative velocity thus increases suddenly. The contribution of the bubble diameters to this evolution is also determined. Finally, a drag correlation, valid for the whole range of void fraction and for pure water-air systems, is proposed. 相似文献
14.
Mariano Martín Francisco J. Montes Miguel A. Galán 《Chemical engineering science》2007,62(6):1741-1752
Bubble columns are among the most used equipments for gas-liquid mass transfer processes. This equipment's aim is to generate gas dispersions into a liquid phase in order to improve the contact between phases. Bubble coalescence has always been one of their greatest problems, since it reduces the superficial gas-liquid contact area. However, bigger bubbles can oscillate, and these oscillations increase the mass transfer rate by means of modifying the contact time as well as the concentration profiles surrounding the bubble. In the present work, the coupled effect has been studied by means of two-holed sieve plates with diameters of 1.5, 2 and 2.5 mm each, close enough to allow the coalescence and separated enough to avoid it. The results show that although coalescence decreases mass transfer rate from bubbles the deformable bubble generated can, in certain cases, balance the decrease in mass transfer rate due to the reduction in superficial area. This fact can then be used to avoid the harmful effect of coalescence on the mass transfer rate. Empirical and theoretical equations have also been used to explain the phenomena. 相似文献
15.
The liquid phase backmixing has been reduced significantly by introducing horizontal perforated sieve plates into a 6.2 cm diameter and 77 cm height and in a 20 cm diameter and 90 cm height bubble columns. For the visbreaking operation of the petroleum residue, where the bubble column is used as soaker such a sectionalization has been suggested. The effect of the introduction of different gas quantities at various axial locations has also been studied to check the effect of increasing gas quantity formed in the visbreaking operation. The nonideality in the liquid phase backmixing has been studied by measuring liquid phase RTD and analysed by using one parameter dispersion model. A new parameter FP (flow parameter) has been defined and a correlation to predict liquid phase dispersion coefficient has been developed which covers the entire range of variables used in the present work. 相似文献
16.
Aida C. Ahmia Madjid Idouhar Kritchart Wongwailikit Nicolas Dietrich Gilles Hbrard 《化学工程与技术》2019,42(11):2465-2475
The effects of cellulose, surfactants, and their combination on the hydrodynamic behavior and the liquid‐side mass transfer coefficient of a bubble column were evaluated. For that purpose, different aqueous solutions containing surfactants (sodium dodecyl sulfate) and cellulose (microcrystalline cellulose, MCC) were investigated. The interfacial areas were calculated from the bubble diameters, the bubble frequencies, and the terminal bubble rising velocities. The liquid‐side mass transfer coefficients were determined from the volumetric mass transfer coefficients measured by the dynamic method. In the concentration range under test, the experimental results proved that the addition of MCC to the studied liquid phases did not affect the mass transfer coefficient. 相似文献
17.
A practical population balance model was used to evaluate the bubble size distribution in a bubble column. In addition, the bubble size distribution in the bubble column was measured at different gas velocities by photography and analysis of the pictures. Four types of liquid, i.e., water and three petroleum‐based liquids, were used in the experiments. The gas phase was air. It was found that the existing models in the literature are not able to satisfactorily predict the experimentally measured bubble size distribution. The model can be corrected by applying a correction factor to the energy dissipation rate. The corrected model fits the experimental bubble size distribution considerably better than the existing models. The variation of this correction factor is reported for different systems at different gas velocities. 相似文献
18.
A transient back flow cell model was used to model the hydrodynamic behaviour of an impinging-jet ozone bubble column. A steady-state back flow cell model was developed to analyze the dissolved ozone concentration profiles measured in the bubble column. The column-average overall mass transfer coefficient, kLa (s?1), was found to be dependent on the superficial gas and liquid velocities, uG (m.s?1) and uL (m.s?1), respectively, as follows: kLa?=?55.58 · uG 1.26· uL 0.08 . The specific interfacial area, a (m?1), was determined as a = 3.61 × 103 · uG 0.902 · uL ?0.038 by measuring the gas hold-up (ε G?=?4.67 · uG 1.11 · uL ?0.05 ) and Sauter mean diameter, dS (mm), of the bubbles (dS?=?7.78 · uG 0.207 · uL ? 0.008 ). The local mass transfer coefficient, kL (m.s?1), was then determined to be: kL?=?15.40 · uG 0.354 · uL 0.118 . 相似文献
19.
The effects of flow condition, bubble dispersion level, and liquid flow rate on the behavior of a novel monolithic downflow bubble column (M‐DBC) were investigated using a reaction model, the palladium‐catalyzed hydrogenation of butyne‐1,4‐diol. The stable and closely packed homogeneous bubble dispersion present in the bulk region of the M‐DBC allowed effective introduction of the gas‐liquid phase for formation of Taylor flow inside the monolith channels. The condition defined as the minimum level dispersion was required in order to obtain high selectivity towards the intermediate product, cis‐2‐butene‐1,4‐diol. Enhanced reaction rates were obtained at increasing the dispersion level and lowering the liquid flow rate. Comparison with the DBC employing 5 % Pd/C powder catalyst and 1 % Pd‐on‐Raschig‐ring revealed a better performance of the M‐DBC (1 % Pd loading) with the advantage of smaller reaction volume and intensified reaction rate. As an alternative to conventional three‐phase reactors, the M‐DBC was so simple due to its inherent characteristic operation and no specially designed device is required. 相似文献
20.
THEORETICAL PREDICTION OF GAS HOLDUP IN BUBBLE COLUMNS WITH NEWTONIAN AND NON-NEWTONIAN LIQUIDS 总被引:1,自引:0,他引:1
A simple model based on an energy balance which takes into account the friction losses at the gas-liquid interface and the slip velocity of single bubble is used to simulate the gas holdup in bubble columns containing Newtonian and non-Newtonian liquids which circulate in both laminar and turbulent flows. Experimental data available from the literature for bubble columns up to 7 m height and 1 m diameter with water and glycerol as Newtonian liquids and different solutions of CMC in a wide range of concentrations as non-Newtonian liquids are simulated with good agreement despite the simplifications made to describe the gas liquid flow regimes. Most of the differences between experimental and calculated gas holdup are justified on the basis of the simplifying assumptions. 相似文献