首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
We applied a photoacoustic spectroscopy technique to isotope ratio measurements of (16)O and (18)O in water-vapor samples, using a pulsed tunable dye laser pumped by a Nd:YAG laser. The fourth overtone bands (4nu(OH)) of water molecules near 720 nm were investigated. We identified the absorption lines of H(2)(16)O and H(2)(18)O in the photoacoustic spectra that we measured by using an (18)O-enriched water sample and the HITRAN database. We measured the difference in the (18)O/(16)O isotope ratios for normal distilled water and Antarctic ice, using the photoacoustic method. The value obtained for the difference between the two samples is delta(18)O = -32 ? 16 per thousand, where the indicated deviation was a 1varsigma value among 240-s measurements, whereas the value measured with a conventional isotope mass spectrometer was delta(18)O = -28 ? 2 per thousand. This method is demonstrated to have the potential of a transportable system for in situ and quick measurements of the H(2)(18)O/H(2)(16)O ratio in the environment.  相似文献   

2.
We demonstrate the feasibility of using laser spectrometry (LS) to analyze isotopically highly enriched water samples (i.e., delta2H < or = 15,000/1,000, 18O < or = 1,200/1,000), as often used in the biomedical doubly labeled water (DLW) method to quantify energy metabolism. The method is an important extension of a recently developed infrared laser direct absorption spectrometer. The measurements on highly enriched, small-size (10 microL liquid water) samples show a clearly better accuracy for the 2H/1H ratio. In the case of 18O/16O, the same level of accuracy is obtained as with conventional isotope ratio mass spectrometer (IRMS) analysis. With LS, the precision is better for both 18O/ 16O and 2H/1H. New is the ability to measure 17O/16O with the same accuracy as 18O/16O. A major advantage of the present technique is the absence of chemical sample preparation. The method is proven to be reliable and accurate and is ready to be used in many biomedical applications.  相似文献   

3.
A low-abundance form of water, H(2)(17)O, was enriched from 0.04% to ~90% by slow evaporation and fractional distillation of tap water. The density and refractive index for H(2)(17)O are reported. Gas chromatography-mass spectrometry (GC-MS) of (16)O- and (17)O-1-hexanols and their trimethyl silyl ethers and of (16)O- and (17)O-hexamethyl disiloxanes was used to determine the percentage of (17)O enrichment in the H(2)(17)O. Furthermore, the chemical shifts of labeled and nonlabeled water dissolved in CDCl(3) differed sufficiently that we could verify the enrichment of H(2)(17)O. (17)O hexanol was synthesized by the reaction of iodohexane with Na(17)OH. (17)O-Labeled trimethylsilanol and (17)O-labeled hexamethyldisiloxane were prepared by the reaction of H(2)(17)O with bis(trimethylsilyl)trifluoroacetamide (BSTFA). To generate standards for (17)O NMR, H(2)(17)O(2), and (17)O camphor were prepared. H(2)(17)O was electrolyzed to form (17)O-labeled hydrogen peroxide which was quantified using two colorimetric assays. (17)O-Labeled camphor was prepared by exchanging the ketone oxygen of camphor using H(2)(17)O. The (17)O-labeled compounds were characterized using (17)O, (1)H, and (13)C NMR and GC-MS. While we were characterizing the labeled camphor, we also detected an unexpected oxygen exchange reaction of primary alcohols, catalyzed by electrophilic ketones such as camphor. The reaction is a displacement of the alcohol OH group by water. This is an example of the usefulness of (17)O NMR in the study of a reaction mechanism that has not been noticed previously.  相似文献   

4.
We demonstrate the first successful application of infrared laser spectrometry to the accurate, simultaneous determination of the relative (2)H/(1)H, (17)O/(16)O, and (18)O/(16)O isotope abundance ratios in water. The method uses a narrow line width color center laser to record the direct absorption spectrum of low-pressure gas-phase water samples (presently 10 μL of liquid) in the 3-μm spectral region. It thus avoids the laborious chemical preparations of the sample that are required in the case of the conventional isotope ratio mass spectrometer measurement. The precision of the spectroscopic technique is shown to be 0.7‰ for δ(2)H and 0.5‰ for δ(17)O and δ(18)O (δ represents the relative deviation of a sample's isotope abundance ratio with respect to that of a calibration material), while the calibrated accuracy amounts to about 3 and 1‰, respectively, for water with an isotopic composition in the range of the Standard Light Antarctic Precipitation and Vienna Standard Mean Ocean Water international standards.  相似文献   

5.
A new lightweight near-infrared tunable diode laser spectrometer CHILD (Compact High-altitude In-situ Laser Diode spectrometer) was developed for flights to the stratosphere as an additional in situ sensor on existing balloonborne payloads. Free-air absorption measurements in the near infrared are made with an open-path Herriott cell with new design features. It offers two individual absorption path lengths optimized for CH4 with 74 m (136 pass) and H2O with 36 m (66 pass). New electronic features include a real-time gain control loop that provides an autocalibration function. In flight-ready configuration the instrument mass is approximately 20 kg, including batteries. It successfully measured stratospheric CH4 and H2O profiles on high-altitude balloons on four balloon campaigns (Environmental Satellite validation) between October 2001 and June 2003. On these first flights, in situ spectra were recorded from ground level to 32,000-m altitude with a sensitivity of 0.1 ppm [(parts per million), ground] to 0.4 ppm (32,000 m) for methane and 0.15-0.5 ppm for water.  相似文献   

6.
Phosphate (PO(4)(3-)) solutions in water and heavy water have been studied by Raman and infrared spectroscopy over a broad concentration range (0.0091-5.280 mol/L) including a hydrate melt at 23 degrees C. In the low wavenumber range, spectra in R-format have been constructed and the R normalization procedure has been briefly discussed. The vibrational modes of the tetrahedral PO(4)(3-)(aq) (T(d) symmetry) have been assigned and compared to the calculated values derived from the density functional theory (DFT) method for the unhydrated PO(4)(3-)(T(d)) and phosphate-water clusters: PO(4)(3-).H(2)O (C(2v)), PO(4)(3-).2H(2)O (D(2d)), PO(4)(3-).4H(2)O (D(2d)), PO(4)(3-).6H(2)O (T(d)), and PO(4)(3-).12H(2)O (T), a cluster with a complete first hydration sphere of water molecules. A cluster with a second hydration sphere of 12 water molecules and 6 in the first sphere, PO(4)(3-).18H(2)O (T), has also been calculated. Agreement between measured and calculated vibrational modes is best in the case of the PO(4)(3-).12H(2)O cluster and the PO(4)(3-).18H(2)O cluster but far less so in the case of the unhydrated PO(4)(3-) or phosphate-water cluster with a lower number of water molecules than 12. The asymmetric, broad band shape of v(1)(a(1)) PO(4)(3-) in aqueous solutions has been measured as a function of concentration and the asymmetric and broad band shape was explained. However, the same mode in heavy water has only half the full width at half-height compared to the mode in normal water. The PO(4)(3-) is strongly hydrated in aqueous solutions. This has been verified by Raman spectroscopy comparing v(2)(H(2)O), the deformation mode of water, and the stretching modes, the v(1)OH and v(3)OH of water, in K(3)PO(4) solutions as a function of concentration and comparison with the same modes in pure water. A mode at approximately 240 cm(-1) (isotropic R spectrum) has been detected and assigned to the restricted translational mode of the strong hydrogen bonds formed between phosphate and water, P-O...HOH. In very concentrated K(3)PO(4) solutions (C(0) > or = 3.70 mol/L) and in the hydrate melt, formation of contact ion pairs (CIPs) could be detected. The phosphate in the CIPs shows a symmetry lowering of the T(d) symmetry to C(3v). In the less concentrated solutions, PO(4)(3-)(aq) solvent separated ion pairs and doubly solvent separated ion pairs exist, while in very dilute solutions fully hydrated ions are present (C(0) < or = 0.005 mol/L). Quantitative Raman measurements have been carried out to follow the hydrolysis of PO(4)(3-)(aq) over a very broad concentration range. From the hydrolysis data, the pK(3) value for H(3)PO(4) has been determined to be 12.45 at 23 degrees C.  相似文献   

7.
A new algorithm for the retrieval of columnar water vapor content is presented. The proposed procedure computes the area of the H2O absorption centered about 940 nm to allow its integrated columnar abundance as well as its density at ground level to be assessed. The procedure utilizes the HITRAN 2000 database as the source of H2O cross-section spectra. Experimental results were derived from radiometrically calibrated hyperspectral images collected by the Airborne Visible-Infrared Imaging Spectrometer (AVIRIS) sensor over the Cuprite mining district in Nevada. Numerical simulations based on the MODTRAN 4 radiative transfer code were also employed for investigating the algorithm's performance. An additional empirical H2O retrieval procedure was tested by use of data gathered by the VIRS-200 imaging spectrometer.  相似文献   

8.
The presence of trace water vapor in process gases such as phosphine, used for compound semiconductor epitaxial growth, can negatively affect the optical and electrical properties of the final device. Therefore, sensitive H2O measurement techniques are required to monitor precursor purity and detect unacceptable contamination levels. A commercial cavity ring-down spectrometer that monitors an H2O absorption line at a wavelength of 1392.53 nm was investigated for service in high purity PH3. Spectral parameters such as the line shape of water vapor in the presence of PH3 as well as background features due to PH3 were measured at different pressures and incorporated into the data analysis software for accurate moisture readings. Test concentrations generated with a diffusion vialbased H2O source and dilution manifold were used to verify instrument accuracy, sensitivity, linearity, and response time. H2O readings at 13.2 kPa corresponded well to added concentrations (slope=0.990+/-0.01) and were linear in the tested range (0-52.7 nmol mol-1). The analyzer was sensitive to changes in H2O concentration of 1.3 nmol mol-1 based on 3sigma of the calibration curve intercept for a weighted linear fit. Local PH3 absorption features that could not be distinguished from the H2O line were present in the purified PH3 spectra and resulted in an additional systematic uncertainty of 9.0 nmol mol-1. Equilibration to changing H2O levels at a flow rate of 80 std cm3 min-1 PH3 occurred in 10-30 minutes. The results indicate that cavity ring-down spectroscopy (CRDS) at 1392.53 nm may be useful for applications such as on-line monitoring (and dry-down) of phosphine gas delivery lines or the quality control of cylinder sources.  相似文献   

9.
Toth RA 《Applied optics》1994,33(21):4868-4879
High-resolution spectra of O(17)- and O(18)-enriched water-vapor samples have been recorded with a Fourier transform spectrometer covering the region between 6600 and 7640 cmcm(-1). Experimental values of line positions and strengths of 1807 absorptions in the (120)-(000), (021)-(000), (200)-(000), (101)-(000), (002)-(000), bands of the two isotopic species were derived from the spectra. The analysis included the determination of accurate rotational levels belonging to the (120), (021), (200), (101), and (002) vibrational states of H(2)(17)O and H(2)(18)O.  相似文献   

10.
We evaluate the spectral quality, radiometric noise, and retrieval performance of a Fourier transform infrared spectrometer, which has been developed for recording spectrally resolved observations in a region of the spectrum which is important both for the science of Earth's climate and applications, such as the remote sensing of temperature and atmospheric gas species. This spectral region extends from 100 to 1600 cm(-1) and encompasses the two fundamental, rotation and vibration, absorption bands of water vapor. The instrument is a customized version of a Bomem AERI (Atmospheric Emitted Radiance Interferometer) spectrometer, whose spectral coverage has been extended in the far infrared with the use of uncooled pyroelectric detectors. Retrieval examples for water vapor and temperature profiles are shown, which also allow us to intercompare the retrieval performance of both H(2)O vibration and rotation bands.  相似文献   

11.
The pure water vapour and water-nitrogen continuum absorption in the 1000 and 2500?cm(-1) atmospheric windows has been studied using a 2?m base-length White-type multi-pass cell coupled with a BOMEM DA3-002 Fourier transform infrared spectrometer. The measurements were carried out at the National Institute of Standards and Technology (NIST, Gaithersburg, MD) over the course of several years (2004, 2006-2007, 2009). New data on the H(2)O:N(2) continuum in the 1000?cm(-1) window are presented and summarized along with the other experimental results and the continuum model. The experimental data reported on the water vapour continuum in these atmospheric windows basically agree with the most reliable laboratory data from the other sources. The MT_CKD (Mlawer-Tobin-Clough-Kneizys-Davies) continuum model significantly departs from the experimental data in both windows. The deviation observed includes the continuum magnitude, spectral behaviour and temperature dependence. In the 2500?cm(-1) region, the model does not allow for the nitrogen fundamental collision-induced absorption (CIA) band intensity enhancement caused by H(2)O:N(2) collisions and underestimates the actual absorption by over two orders of magnitude. The water vapour continuum interpretation as a typical CIA spectrum is reviewed and discussed.  相似文献   

12.
Ultraviolet (UV) irradiation (253.7nm) in the presence of hydrogen peroxide (H(2)O(2)) was used to decompose aqueous ametryn. The concentrations of ametryn were measured with time under various experiment conditions. The investigated factors included H(2)O(2) dosages, initial pH, initial ametryn concentrations, and a variety of inorganic anions. Results showed that ametryn degradation in UV/H(2)O(2) process was a pseudo-first-order reaction. Removal rates of ametryn were greatly affected by H(2)O(2) dosage and initial concentrations of ametryn, but appeared to be slightly influenced by initial pH. Furthermore, we investigated the effects of four anions (SO(4)(2-), Cl(-), HCO(3)(-), and CO(3)(2-)) on ametryn degradation by UV/H(2)O(2). The impact of SO(4)(2-) seemed to be insignificant; however, Cl(-), HCO(3)(-), and CO(3)(2-) considerably slowed down the degradation rate because they could strongly scavenge hydroxyl radicals (OH) produced during the UV/H(2)O(2) process. Finally, a preliminary cost analysis revealed that UV/H(2)O(2) process was more cost-effective than the UV alone in removal of ametryn from water.  相似文献   

13.
We describe the four-laser airborne infrared (FLAIR) instrument, a tunable diode laser absorption spectrometer designed for simultaneous high-sensitivity in situ measurements of four atmospheric trace gases in the troposphere. The FLAIR spectrometer was employed during the large-scale airborne research campaign on tropospheric ozone (TROPOZ II) in 1991 and was used to measure CO, H(2) O(2), HCHO, and NO(2) in the free troposphere where detection limits below 100 parts in 10(12) by volume were achieved.  相似文献   

14.
Teichert H  Fernholz T  Ebert V 《Applied optics》2003,42(12):2043-2051
We present what is to our knowledge the first near-infrared diode-laser-based absorption spectrometer that is suitable for simultaneous in situ measurement of carbon monoxide, water vapor, and temperature in the combustion chamber (20-m diameter, 13-m path length) of a 600-MW lignite-fired power plant. A fiber-coupled distributed-feedback diode-laser module at 1.56 microm served for CO detection, and a Fabry-Perot diode laser at 813 nm was used to determine H2O concentrations and temperature from multiline water spectra. Despite severe light losses (transmission, <10(-8)) and strong background radiation we achieved a resolution of 1.9 x 10(-4) (1sigma) fractional absorption, equivalent to 200 parts in 10(6) by volume of CO (at 1450 K, 10(5) Pa) with 30-s averaging time.  相似文献   

15.
Hearn JD  Smith GD 《Analytical chemistry》2004,76(10):2820-2826
A new technique employing chemical ionization mass spectrometry (CIMS) is described that allows the composition of organic particles to be determined on the time scale of seconds. With this Aerosol CIMS technique, particles are vaporized thermally at temperatures up to 480 degrees C, and the resulting vapor is chemically ionized and detected with a quadrupole mass spectrometer. The separation of the vaporization and ionization steps allows greater control and more flexibility for the detection of condensed phases than with other chemical ionization methods. Consequently, composition can be correlated to volatility, providing an additional dimension of information. The use of a variety of positive and negative reagent ions, such as H(+)(H(2)O)(2), H(+)(CH(3)OH)(2), NO(+), O(2)(+), O(2)(-), F(-), and SF(6)(-), offers flexibility in the detection sensitivity and specificity. Furthermore, the degree of fragmentation of the resulting ion can be controlled, providing more straightforward identification and quantification than with other commonly used methods, such as electron impact ionization. Examples are given of the detection of aerosols consisting of organics with various functionalities, including alkanes, alkenes, alcohols, aldehydes, ketones, and carboxylic acids. Applications of this technique to laboratory studies of atmospherically relevant aerosol reactions are discussed.  相似文献   

16.
A Kβ satellite peak in X-ray fluorescence (XRF) spectra is observed as a counterpart of the pre-edge peak of the X-ray absorption near edge structure (XANES). In Kβ emission of chromium, a small satellite peak is observed at 5.983-5.988 keV only for hexavalent chromium compounds such as CrO(3), Na(2)CrO(7)·2H(2)O, Na(2)CrO(4)·4H(2)O, K(2)Cr(2)O(7), K(2)CrO(4), Zn(2)CrO(4)(OH)(2)·2H(2)O, PbCrO(4), and BaCrO(4), together with the main peak at 5.947 keV, while trivalent chromium compounds such as Cr(2)O(3) and Cr(OH)(3)·nH(2)O show only the main peak at 5.947 keV. This corresponds to the fact that the K pre-edge peak in XANES is observed only for the hexavalent chromium compounds. The electronic level causing the satellite peak is almost at the same energy level as that causing the pre-edge peak. Our finding not only affects the interpretation of the origin of the pre-edge peaks but also leads to the simple speciation method of chromium compounds using XRF.  相似文献   

17.
In this paper we propose a rapid and highly selective far-ultraviolet (FUV) spectroscopic method for the simultaneous determination of peracetic acid (PAA), hydrogen peroxide, and acetic acid (AA). For this purpose we developed a novel FUV spectrometer that enables us to measure the spectra down to 180 nm. Direct determination of PAA, H(2)O(2), and AA, the three main species in disinfectant solutions, was carried out by using their absorption bands in the 180-220-nm region. The proposed method does not require any reagents or catalysts, a calibration standard, and a complicated procedure for the analysis. The only preparation procedure requested is a dilution of H(2)O(2) with pure water to a concentration range lower than 0.2 wt % in the sample solutions. Usually, the required concentration range can be obtained by the 10 times volume dilution of the actual disinfectant solutions. As the measured sample does not leave any impurity for the disinfection, it can be reused completely by using a circulation system. The detection limit for PAA of the new FUV spectrometer was evaluated to be 0.002 wt %, and the dynamic ranges of the measured concentrations were from 0 to 0.05 wt %, from 0 to 0.2 wt %, and from 0 to 0.2 wt % for PAA, H(2)O(2), and AA, respectively. The response time for the simultaneous determination of the three species is 30 s, and the analysis is applicable even to the flowing samples. This method may become a novel approach for the continuous monitoring of PAA in disinfectant solutions on the process of sterilization.  相似文献   

18.
Neutron scattering has been demonstrated to be a powerful tool for characterizing the structure and dynamics of biological molecules and for investigating the physical and chemical mechanisms of biophysical processes. The aim of the present work is to investigate by inelastic neutron scattering (INS) the vibrational behaviour of a class of bioprotectant systems, such as homologous disaccharides, trehalose, maltose and sucrose, in water mixtures. INS measurements have been performed on trehalose/H2O, maltose/H2O and sucrose/H2O mixtures at very low temperature as a function of concentration by using the thermal original spectrometer with cylindrical analyzers (TOSCA) spectrometer at the ISIS Facility (DRAL, UK).The findings allow the analyses of the vibrational features of the INS spectra in order to study the effect of disaccharides on the H2O hydrogen-bonded tetrahedral network. The obtained neutron scattering findings point out that disaccharides, and in particular trehalose, have a destructuring effect on the water tetrahedral network, as emphasized by the analysis of the librational modes region from 50 to 130 meV energy transfer. On the other hand, the analysis of the bending modes region (130-225 meV) shows a locally ordered structure in the disaccharide/H2O mixtures.Finally, the observed experimental evidences are linked to the different bioprotective effectiveness of disaccharides as a function of concentration.  相似文献   

19.
Durry G  Megie G 《Applied optics》1999,38(36):7342-7354
The Spectromètre à Diodes Laser Accordables (SDLA), a balloonborne spectrometer devoted to the in situ measurement of CH(4) and H(2)O in the atmosphere that uses commercial distributed-feedback InGaAs laser diodes in combination with differential absorption spectroscopy, is described. Absorption spectra of CH(4) (in the 1.653-mum region) and H(2)O (in the 1.393-mum region) are simultaneously sampled at 1-s intervals by coupling with optical fibers of two near-infrared laser diodes to a Herriott multipass cell open to the atmosphere. Spectra of methane and water vapor in an altitude range of ~1 to ~31 km recorded during the recent balloon flights of the SDLA are presented. Mixing ratios with a precision error ranging from 5% to 10% are retrieved from the atmospheric spectra by a nonlinear least-squares fit to the spectral line shape in conjunction with in situ simultaneous pressure and temperature measurements.  相似文献   

20.
Four advanced oxidation processes (UV/TiO(2), UV/IO(4)(-), UV/S(2)O(8)(2-), and UV/H(2)O(2)) were tested for their ability to mineralize naphthenic acids to inorganic carbon in a model oil sands process water containing high dissolved and suspended solids at pH values ranging from 8 to 12. A medium pressure mercury (Hg) lamp was used, and a Quartz immersion well surrounded the lamp. The treatment goal of 5mg/L naphthenic acids (3.4 mg/L total organic carbon (TOC)) was achieved under four conditions: UV/S(2)O(8)(2-) (20mM) at pH 8 and 10, and UV/H(2)O(2) (50mM) at pH 8 (all with the Quartz immersion well). Values of electrical energy required to meet the treatment goal were about equal for UV/S(2)O(8)(2-) (20mM) and UV/H(2)O(2) (50mM) at pH 8, but three to four times larger for treatment by UV/S(2)O(8)(2-) (20mM) at pH 10. The treatment goal was also achieved using UV/S(2)O(8)(2-) (20mM) at pH 10 when using a Vycor filter that transmits light primarily in the mid and near UV, suggesting that that treatment of naphthenic acids by UV/S(2)O(8)(2-) using low pressure Hg lamps may be feasible.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号