首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Improved sensitivity in the analysis of stable chlorine isotopes of organochlorines (delta(37)Cl-OCl) has been established using sealed tube combustion in conjunction with thermal ionization mass spectrometry (TIMS). TIMS of chlorine isotopes was performed on <85 nmol of Cl with an achievable precision of <0.25 per thousand for pure inorganic chloride samples and 0.46 per thousand for chloride liberated from organochlorines (OCls). This makes possible significant reductions in the overall sample size requirement, as compared to the techniques of gas source stable isotope ratio mass spectrometry (SIRMS). Yields in excess of 99% were demonstrated in the dechlorination of <0.14 micromol 1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane (DDT), and the overall yield, including purification of liberated chloride, was 86-97%. The accuracy of TIMS in the measurement of chlorine isotopes derived from OCls was confirmed by analysis of a DDT sample previously analyzed with SIRMS.(9) Using the described method for TIMS, the DDT sample gave a bulk chlorine isotope ratio of delta(37)Cl -4.42 +/- 0.46 per thousand (1sigma). The reported value from SIRMS analysis is -4.34 +/- 0.25 per thousand, indicating the conformity of the two methods.  相似文献   

2.
Lithium isotope composition of basalt glass reference material   总被引:2,自引:0,他引:2  
We present data on the lithium isotope compositions of glass reference materials from the United States Geological Survey (USGS) and the National Institute of Standards and Technology (NIST) determined by multicollector inductively coupled plasma mass spectrometry (MC-ICPMS), thermal ionization mass spectrometry (TIMS), and secondary ionization mass spectrometry (SIMS). Our data on the USGS basaltic glass standards agree within 2 per thousand, independent of the sample matrix or Li concentration. For SIMS analysis, we propose use of the USGS glasses GSD-1G (delta(7)Li 31.14 +/- 0.8 per thousand, 2sigma) and BCR-2G (delta(7)Li 4.08 +/- 1.0 per thousand, 2sigma) as suitable standards that cover a wide range of Li isotope compositions. Lithium isotope measurements on the silica-rich NIST 600 glass series by MC-ICPMS and TIMS agree within 0.8 per thousand, but SIMS analyses show systematic isotopic differences. Our results suggest that SIMS Li isotope analyses have a significant matrix bias in high-silica materials. Our data are intended to serve as a reference for both microanalytical and bulk analytical techniques and to improve comparisons between Li isotope data produced by different methodologies.  相似文献   

3.
A method is described for the measurement of apparent zinc absorption in human nutrition studies. An enriched source of the stable isotope 67Zn was given to adult subjects together with a wheat cereal and the unabsorbed 67Zn measured in the feces. After drying, subsamples of the homogenized fecal material were ashed at 480 degrees C, purified for analysis by ion exchange chromatography, and the 64Zn/67Zn ratios determined by both fast atom bombardment mass spectrometry and thermal ionization quadrupole mass spectrometry. Good agreement was found between the two sets of results with mean precisions of approximately 0.5% for both techniques.  相似文献   

4.
Xiao Y  Lu MH  Zhang C  Wang Q  Wei H  Sun A  Liu W 《Analytical chemistry》2002,74(11):2458-2464
The factors that affect isotopic measurement of chlorine based on Cs2Cl+ ion by thermal ionization mass spectrometry were studied. Graphite is essential for the emission of Cs2Cl+ ion from CsCl. No Cs2Cl+ ions are detected in the absence of graphite on the filament. The emission of Cs2Cl+ ion and the measured 37Cl/35Cl ratio were affected by different varieties of graphite, the pH value of the sample solution, and impurities in the solution. High-precision isotopic measurement of chlorine based on Cs2Cl+ ion is achieved only by using graphite with a perfect crystal structure. The measured 37Cl/35Cl ratios were much higher, and even the emission of Cs2Cl+ ion becomes impossible when pH values of the sample solution were higher than 6, corresponding to the presence of excess Cs. The measured 37Cl/35Cl ratios were higher when SO4(2-) and NO3- anions were present. The results show that the measured 37Cl/35Cl ratios are weakly related to the amount of chlorine on filament in a range from 1 to 500 microg.  相似文献   

5.
A new methodology for bromine stable isotope determination by continuous-flow isotope ratio mass spectrometry (CF-IRMS) was developed. The technique was tested on inorganic samples. Inorganic bromide was precipitated in the form of silver bromide by using silver nitrate in a standard methodology. Bromine stable isotope analysis was carried out on methyl bromide (CH3Br) after converting silver bromide to methyl bromide by reacting it with methyl iodide (CH3I). The system used in this study is an IsoPrime IRMS, with analytical capabilities of both dual-inlet and continuous-flow modes coupled with an Agilent 6890 GC equipped with a CTC Analytics CombiPAL autosampler. This new technique measures samples as small as 0.2 mg of AgBr (1 micromol of Br-). The bromine stable isotope analysis using continuous flow technology showed excellent precision and accuracy. The internal precision using pure methyl bromide gas is better than +/-0.03 per thousand (+/-SD); the external precision using seawater standard is better than +/-0.06 per thousand (+/-SD) for n = 12. Moreover, the sample analysis time is 16 min, as compared to 75 min needed in previous techniques. This allows for 50 samples to be analyzed in 1 day, as compared to 8 samples using the conventional techniques. A series of natural saline formation waters and brines from sedimentary and crystalline rock environments was measured by this new methodology to test the potential natural range of delta81Br. The bromine isotopic composition of the samples ranged from 0.00 to +1.80 per thousand relative to standard mean ocean bromide (SMOB). Initial trends and distinctive isotopic difference were noticed between crystalline shield brines and sedimentary formation brines.  相似文献   

6.
Stable isotopic characterization of chlorine in chlorinated aliphatic pollution is potentially very valuable for risk assessment and monitoring remediation or natural attenuation. The approach has been underused because of the complexity of analysis and the time it takes. We have developed a new method that eliminates sample preparation. Gas chromatography produces individually eluted sample peaks for analysis. The He carrier gas is mixed with Ar and introduced directly into the torch of a multicollector ICPMS. The MC-ICPMS is run at a high mass resolution of >/=10 000 to eliminate interference of mass 37 ArH with Cl. The standardization approach is similar to that for continuous flow stable isotope analysis in which sample and reference materials are measured successively. We have measured PCE relative to a laboratory TCE standard mixed with the sample. Solvent samples of 200 nmol to 1.3 micromol (24-165 microg of Cl) were measured. The PCE gave the same value relative to the TCE as measured by the conventional method with a precision of 0.12 per thousand (2x standard error) but poorer precision for the smaller samples.  相似文献   

7.
Down-scaling of a cocondensation method to produce volatile pentakis(trifluorophosphine)iron(0) for measuring isotope ratios by gas source mass spectrometry is described. Starting from 10 mg of iron, this method allows synthesis of a sufficient amount of Fe(PF(3))(5) that can be used to measure iron content and/or isotope ratios in real-life samples. The advantage over thermal ionisation mass spectrometry is that more precise determinations of ratios/amounts are possible. Reproducibilities for n((54)Fe)/n((56)Fe) and n((57)Fe)/n((56)Fe) are (1-3) × 10(-4), while those obtained by thermal ionization mass spectrometry are at the 10(-3) level.  相似文献   

8.
A technique has been developed to quantify ultratrace 231Pa (50-2000 ag; 1 ag = 10(-18) g) concentrations in seawater using isotope-dilution thermal ionization mass spectrometry (TIMS). The method is a modification of a process developed by Pickett et al. (Pickett, D. A.; Murrell, M. T.; Williams, R. W. Anal. Chem. 1994, 66, 1044-1049) and extends the technique to very low levels of protactinium. The procedural blank is 16 +/- 15 ag (2sigma), and the ionization efficiency (ions generated/atom loaded) approaches 0.5%. Measurement time is <1 h. The amount of 231Pa needed to produce 231Pa data with an uncertainty of +/-4-12% is 100-1000 ag (approximately 3 x 10(5) to 3 x 10(6) atoms). Replicate measurements made on known standards and seawater samples demonstrate that the analytical precision approximates that expected from counting statistics and that, based on detection limits of 38 and 49 ag, protactinium can be detected in a minimum sample size of surface seawater of approximately 2 L for suspended particulate matter and <0.1 L for filtered (<0.4 microm) seawater, respectively. The concentration of 231Pa (tens of attograms per liter) can be determined with an uncertainty of +/-5-10% (2sigma) for suspended particulate matter filtered from 5 to 10 L of seawater. For the dissolved fraction, 0.5-1 L of seawater yields 231Pa measurements with a precision of 1-10%. Sample size requirements are orders of magnitude less than traditional decay-counting techniques and significantly less than previously reported ICP-MS techniques. Our technique can also be applied to other environmental samples, including cave waters, rivers, and igneous rocks.  相似文献   

9.
We measured the Ni isotopic composition of metal from a variety of meteorite groups to search for variations in the 60Ni abundance from the decay of the short-lived nuclide 60Fe (t(1/2) = 1.49 My) and for possible nucleosynthetic effects in the other stable isotopes of Ni. We developed a high-yield Ni separation procedure based on a combination of anion and cation exchange chromatography. Nickel isotopes were measured on a single-focusing, multicollector, inductively coupled mass spectrometer (MC-ICPMS). The external precision on the mass-bias-corrected 60Ni/58Ni ratio (+/-0.15 epsilon; 2sigma) is comparable to similar studies using double-focusing MC-ICPMS. We report the first high-precision data for 64Ni, the least abundant Ni isotope, obtained via MC-ICPMS. The external precision on the mass-bias-corrected 64Ni/58Ni ratio (+/-1.5 epsilon; 2sigma) is better than previous studies using thermal ionization mass spectrometry. No resolvable excesses relative to a terrestrial standard in the mass-bias-corrected 60Ni/58Ni ratio were detected in any meteoritic metal samples. However, resolvable deficits in this ratio were measured in the metal from several unequilibrated chondrites, implying a 60Fe/56Fe ratio of approximately 1 x 10(-6) at the time of Fe/Ni fractionation in chondritic metal. A 60Fe/56Fe ratio of (4.6 +/- 3.3) x 10(-7) is inferred at the time of Fe/Ni fractionation on the parent bodies of magmatic iron meteorites and pallasites. No clearly resolvable non-mass-dependent anomalies were detected in the other stable isotopes of Ni in the samples investigated here, indicating that the Ni isotopic composition in the early solar system was homogeneous (at least at the level of precision reported here) at the time of meteoritic metal formation.  相似文献   

10.
A new method for the measurement of SI traceable carbon isotope amount ratios using a multicollector inductively coupled mass spectrometer (MC-ICPMS) is reported for the first time. Carbon (13)C/(12)C isotope amount ratios have been measured for four reference materials with carbon isotope amount ratios ranging from 0.010659 (delta(13)C(VPDB) = -46.6 per thousand) to 0.011601 (delta(13)C(VPDB) = +37 per thousand). Internal normalization by measuring boron (11)B/(10)B isotope amount ratios has been used to correct for the effects of instrumental mass bias. Absolute (13)C/(12)C ratios have been measured and corrected for instrumental mass bias and full uncertainty budgets have been calculated using the Kragten approach. Corrected (13)C/(12)C ratios for NIST RM8545 (Lithium Carbonate LSVEC), NIST RM8573 (L-Glutamic Acid USGS40), NIST RM8542 (IAEA-CH6 Sucrose) and NIST RM8574 (L-Glutamic Acid USGS41) differed from reference values by 0.06-0.20%. Excellent linear correlation (R = 0.9997) was obtained between corrected carbon isotope amount ratios and expected carbon isotope amount ratios of the four chosen NIST RMs. The method has proved to be linear within this range (from (13)C/(12)C = 0.010659 to (13)C/(12)C =0.011601), and therefore, it is suitable for the measurement of carbon isotope amount ratios within the natural range of variation of organic carbon compounds, carbonates, elemental carbon, carbon monoxide, and carbon dioxide. In addition, a CO2 gas sample previously characterized in-house by conventional dual inlet isotope ratio mass spectrometry has been analyzed and excellent agreement has been found between the carbon isotope amount ratio value measured by MC-ICPMS and the IRMS measurements. Absolute values for carbon isotope amount ratios traceable to the SI are given for each NIST RM, and the combined uncertainty budget (including instrumental error and each parameter contributing to Russell expression for mass bias correction) has been found to be < 0.1% for the four materials. The advantage of the method versus conventional gas source isotope ratio mass spectrometry measurements is that carbon isotope amount ratios are measured as C(+) instead of CO2(+), and therefore, an oxygen (17)O correction due to the presence of (12)C(17)O(16)O(+) is not required. Organic compounds in solution can be measured without previous derivatization, combustion steps, or both, thus making the process simple. The novel methodology opens new avenues for the measurement of absolute carbon isotope amount ratios in a wide range of samples.  相似文献   

11.
Here we describe an on-line method for measuring delta(37)Cl values of chloride bearing salts, waters, and organic materials using multicollector continuous-flow isotope ratio mass spectrometry (CF-IRMS). Pure AgCl quantitatively derived from total Cl in water, inorganic Cl salts, and biological samples was reacted with iodomethane in evacuated 10-mL stopper sealed glass vials to produce methyl chloride gas. A GV Instruments Multicollector CF-IRMS with CH(3)Cl optimized collector geometry was modified to accommodate a headspace single-sample gas injection port prior to a GC column. The GC column was a 2-m Porapak-Q packed column held at 160 degrees C. The resolved sample CH(3)Cl was introduced to the IRMS source in a helium stream via an open split. delta(37)Cl values were calculated by measurement of CH(3)Cl at m/z 52/50 and by comparison to a reference pulse of CH(3)Cl calibrated to standard mean ocean chloride. Sample CH(3)Cl analysis time was approximately 6 min. Injections of 40 microL of pure CH(3)Cl gas yielded a repeatability (+/-SD) of +/-0.06 per thousand for delta(37)Cl (n = 10). Combined GC and IRMS source linearity for CH(3)Cl was <0.2 per thousand/nA (V) peak height. External repeatability, based on processing of seawater and NaCl reference solutions, was better than +/-0.08 per thousand. The smallest sample for delta(37)Cl analysis by this method was approximately 0.2 micromol of Cl. Selected results from a river basin and biological samples study illustrate the potential of on-line chlorine isotope assays in environmental pollution studies.  相似文献   

12.
Atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI), together with tandem mass spectrometry (MSn), are used to study the mechanism of chlorination of amines and to develop a method for qualitative and quantitative determination of organic chloramines. Cyclohexylamine and 1,4-butanediamine (putrescine) are used as model compounds to investigate the mechanisms of the reactions between primary aliphatic amines and hypochlorous acid (aqueous Cl2). The chlorination products are identified and characterized by collision-induced dissociation (CID) and H/D exchange. Chlorination occurs by electrophilic addition of Cl+ and may be followed by HCl elimination, hydrolysis, or, in the case of diamines, amine elimination by intramolecular nucleophilic substitution. The relative rates of chlorination at amine and chloramine nitrogens are a function of pH and depend on the basicity of the amine. A novel method for active chlorine quantification using ESI or APCI mass spectrometry is suggested on the basis of the extent of chlorination of a sacrifical amine standard. This measurement has a limit of detection for N-chlorocyclohexylamine in the range of 0.1-10 microM, a linear dynamic range of 10(2)-10(3), and an accuracy of +/-10%, as determined for wastewater samples.  相似文献   

13.
Analysis of perchlorate in water and soil by electrospray LC/MS/MS   总被引:1,自引:0,他引:1  
A method has been developed for the determination of perchlorate in water and soil matrixes using electrospray liquid chromatography/mass spectrometry/mass spectrometry. Perchlorate is quantitated by monitoring the ion signal from mass 83, which is formed by a loss of an oxygen atom from the perchlorate molecular ion. The method was developed to be effective and economical in production laboratory analysis of perchlorate in environmental water and soil samples. Data were gathered to define method sensitivity, performance, selectivity, and robustness. Analyte stability, method susceptibility to interferences, and the reliability of the chlorine isotope ratio as an identification tool were examined. The aqueous method detection limit (MDL) is 0.05 microg/L and was determined using an actual groundwater matrix. The soil MDL is 0.5 microg/kg and was determined using Ottawa sand. The stability study was performed by spiking water samples at 0.25, 10, and 20 microg/L and analyzing them 50 days later. Acceptable recoveries were obtained for all samples. The relative standard deviation (RSD) for the replicate analyses in the stability study indicates that the method is capable of RSD values less than 5% in a relatively clean groundwater matrix. The ionization suppression study was performed by spiking water samples containing 1000 mg/L carbonate, chloride, and sulfate with 0.05 and 0.5 microg/L perchlorate and then measuring the recovery of the spike. The results indicate that the procedure does not have significant suppression effects at the high salt levels tested. Calibration, quality control sample, field sample, and suppression study data were combined to examine isotope ratio reliability. The results of that work show that chlorine isotope ratios can be used to define statistical process control limits for use as an additional analyte identification tool.  相似文献   

14.
We describe a new chemical separation method to isolate Ca from other matrix elements in biological samples, developed with the long-term goal of making high-precision measurement of natural stable Ca isotope variations a clinically applicable tool to assess bone mineral balance. A new two-column procedure utilizing HBr achieves the purity required to accurately and precisely measure two Ca isotope ratios ((44)Ca/(42)Ca and (44)Ca/(43)Ca) on a Neptune multiple collector inductively coupled plasma mass spectrometer (MC-ICPMS) in urine. Purification requirements for Sr, Ti, and K (Ca/Sr > 10?000; Ca/Ti > 10?000?000; and Ca/K > 10) were determined by addition of these elements to Ca standards of known isotopic composition. Accuracy was determined by (1) comparing Ca isotope results for samples and standards to published data obtained using thermal ionization mass spectrometry (TIMS), (2) adding a Ca standard of known isotopic composition to a urine sample purified of Ca, and (3) analyzing mixtures of urine samples and standards in varying proportions. The accuracy and precision of δ(44/42)Ca measurements of purified samples containing 25 μg of Ca can be determined with typical errors less than ±0.2‰ (2σ).  相似文献   

15.
The stable isotope composition of dissolved organic carbon (delta(13)C-DOC) provides powerful information toward understanding carbon sources and cycling, but analytical limitations have precluded its routine measurement in natural samples. Recent interfacing of wet oxidation-based dissolved organic carbon analyzers and isotope ratio mass spectrometers has simplified the measurement of delta(13)C-DOC in freshwaters, but the analysis of salty estuarine/marine samples still proves difficult. Here we describe the coupling of the more widespread high-temperature catalytic oxidation-based total organic carbon analyzer to an isotope ratio mass spectrometer (HTC-IRMS) through cryogenic trapping of analyte gases exiting the HTC analyzer for routine analysis of delta(13)C-DOC in aquatic and marine samples. Targeted elimination of major sources of background CO2 originating from the HTC analyzer allows for the routine measurement of samples over the natural range of DOC concentrations (from 40 microM to over 2000 microM), and salinities (<0.1-36 g/kg). Because consensus reference natural samples for delta(13)C-DOC do not exist, method validation was carried out with water-soluble stable isotope standards as well as previously measured natural samples (IAEA sucrose, Suwannee River Fulvic Acids, Deep Sargasso Sea consensus reference material, and St. Lawrence River water) and result in excellent delta(13)C-DOC accuracy (+/-0.2 per thousand) and precision (+/-0.3 per thousand).  相似文献   

16.
We describe a new method for the chemical separation and analysis of Pa in silicate rock samples by isotope dilution. Our new technique has the following advantages over previous methods: (a) The initial separation of Pa from the rock matrix is carried out using anionic exchange resin and HCl-HF mixtures, avoiding the need to remove F(-) quantitatively from the sample solution prior to this step, (b) Efficient ionization of Pa is achieved using a multicollector inductively coupled plasma mass spectrometer, so that smaller sample sizes and shorter measurement times are required, compared to previous methods using thermal ionization mass spectrometry or alpha spectrometry. (c) Plasma ionization requires less efficient separation of the high field strength elements from Pa, thus reducing reagent volumes, blanks, and sample preparation times. Instrumental mass fractionation can be corrected for using admixed U of known isotopic composition. Using this method, Pa concentrations can be measured to a precision of approximately 0.5% and an accuracy of approximately 1% using only a few tens of femtograms of Pa.  相似文献   

17.
An inductively coupled plasma mass spectrometer with dynamic reaction cell (ICP-DRC-MS) was optimized for determining (44)Ca/(40)Ca isotope ratios in aqueous solutions with respect to (i) repeatability, (ii) robustness, and (iii) stability. Ammonia as reaction gas allowed both the removal of (40)Ar+ interference on (40)Ca+ and collisional damping of ion density fluctuations of an ion beam extracted from an ICP. The effect of laboratory conditions as well as ICP-DRC-MS parameters such a nebulizer gas flow rate, rf power, lens potential, dwell time, or DRC parameters on precision and mass bias was studied. Precision (calculated using the "unbiased" or "n - 1" method) of a single isotope ratio measurement of a 60 ng g(-1) calcium solution (analysis time of 6 min) is routinely achievable in the range of 0.03-0.05%, which corresponded to the standard error of the mean value (n = 6) of 0.012-0.020%. These experimentally observed RSDs were close to theoretical precision values given by counting statistics. Accuracy of measured isotope ratios was assessed by comparative measurements of the same samples by ICP-DRC-MS and thermal ionization mass spectrometry (TIMS) by using isotope dilution with a (43)Ca-(48)Ca double spike. The analysis time in both cases was 1 h per analysis (10 blocks, each 6 min). The delta(44)Ca values measured by TIMS and ICP-DRC-MS with double-spike calibration in two samples (Ca ICP standard solution and digested NIST 1486 bone meal) coincided within the obtained precision. Although the applied isotope dilution with (43)Ca-(48)Ca double-spike compensates for time-dependent deviations of mass bias and allows achieving accurate results, this approach makes it necessary to measure an additional isotope pair, reducing the overall analysis time per isotope or increasing the total analysis time. Further development of external calibration by using a bracketing method would allow a wider use of ICP-DRC-MS for routine calcium isotopic measurements, but it still requires particular software or hardware improvements aimed at reliable control of environmental effects, which might influence signal stability in ICP-DRC-MS and serve as potential uncertainty sources in isotope ratio measurements.  相似文献   

18.
Recent advances in gas chromatography combustion-isotope ratio mass spectrometry (GCC-IRMS) has made compound-specific isotope analysis routine, but reports on position-specific isotopic analysis are still scarce. On-line GC-pyrolysis (Py) coupled to GCC-IRMS is reported here for isolation and isotopic characterization of alaninol and phenethylamine, analogues of alanine and phenylalanine, respectively. Ideally, pyrolytic fragments will originate from unique sites within the parent molecule, and isotope ratios for each position within the parent can either be measured directly or calculated from fragment isotope ratios without substantially degrading the analytical precision. Alaninol pyrolysis yielded several fragments, of which CO and CH4 were used for isotope ratio calculations. Isotope labeling experiments showed that CO derived entirely from the C(1) position, while all three positions of alaninol contributed to CH4 (29.0 +/- 0.3% from C(1), 3.6 +/- 0.2% from C(2), and 66.9 +/- 1.1% from C(3)). We demonstrate iterative use of mass balance to calculate isotope ratios from all positions despite the nonideal positional fidelity of CH4. Pyrolysis of phenethylamine generated benzene and toluene fragments. Benzene derived entirely from C(ring), and toluene was proportionately formed from C(3) and C(ring). Relative intramolecular isotope ratios (Deltadelta13C) were calculated directly from delta13C of fragments or indirectly by mass balance. Though the C(3) isotope ratio was calculated from the benzene and toluene fragments, propagation of errors showed that the final precision of the determination was degraded due to the small contribution that C(3) makes to toluene. Samples of each amino acid from four different vendors showed natural variability between sources, especially at the C(1) position of alaninol (range of Deltadelta13C approximately 50 per thousand). The average precision was SD(Deltadelta13C) < 0.20 per thousand for directly measured positions of alaninol and phenethylamine. The precision of indirectly measured positions was poorer (SD(Deltadelta13C) = 0.94 per thousand for alaninol, 6.54 per thousand for phenethylamine) due to propagation of errors. These data demonstrate that GC-Py-GCC-IRMS data can be used to extract high-precision isotope ratios from amino acids despite nonideal positional fidelity in fragments and that natural intramolecular variability in delta13C can be used to distinguish different sources of amino acids.  相似文献   

19.
Chlorine isotope analysis of chlorinated hydrocarbons like trichloroethylene (TCE) is of emerging demand because these species are important environmental pollutants. Continuous flow analysis of noncombusted TCE molecules, either by gas chromatography/isotope ratio mass spectrometry (GC/IRMS) or by GC/quadrupole mass spectrometry (GC/qMS), was recently brought forward as innovative analytical solution. Despite early implementations, a benchmark for routine applications has been missing. This study systematically compared the performance of GC/qMS versus GC/IRMS in six laboratories involving eight different instruments (GC/IRMS, Isoprime and Thermo MAT-253; GC/qMS, Agilent 5973N, two Agilent 5975C, two Thermo DSQII, and one Thermo DSQI). Calibrations of (37)Cl/(35)Cl instrument data against the international SMOC scale (Standard Mean Ocean Chloride) deviated between instruments and over time. Therefore, at least two calibration standards are required to obtain true differences between samples. Amount dependency of δ(37)Cl was pronounced for some instruments, but could be eliminated by corrections, or by adjusting amplitudes of standards and samples. Precision decreased in the order GC/IRMS (1σ ≈ 0.1‰), to GC/qMS (1σ ≈ 0.2-0.5‰ for Agilent GC/qMS and 1σ ≈ 0.2-0.9‰ for Thermo GC/qMS). Nonetheless, δ(37)Cl values between laboratories showed good agreement when the same external standards were used. These results lend confidence to the methods and may serve as a benchmark for future applications.  相似文献   

20.
In uncontaminated natural materials, plutonium and technetium exist exclusively as products (daughters) of nuclear reactions in which uranium is the principal reactant (parent). Under conditions of chemical stability over geologic periods of time, the relative abundances of daughter and parent elements are fixed by the rates of nuclear reactions and the decay of the daughter radionuclide. The state of this nuclear secular equilibrium condition is the primary basis of the geochemical study of these elements in nature. Thus, it is critical that nuclear parent and daughter abundances are measured in the same sample. We have developed a quantitative procedure for measuring subpicogram quantities of plutonium and technetium in gram quantities of geologic matrices such as uranium ores. The procedure takes advantage of the aggressive properties of sodium peroxide/hydroxide fusion to ensure complete dissolution and homogenization of complex materials, the precision provided by isotope dilution techniques, and the extreme sensitivity offered by thermal ionization mass spectrometry. Using this technique, a quantitative aliquot can be removed for uranium analysis by isotope dilution thermal ionization mass spectrometry or α spectrometry. Although the application of the procedure is unique, the analytical concepts may find more general application in studies of environmental contamination by nuclear materials. To assess the precision and accuracy of the analytical results, blanks and standards were analyzed routinely for a 1-year period to ensure quality control of our sample analyses. The average technetium blank is 5 ± 4 fg (n = 8), and that for plutonium is 0.17 ± 0.15 pg (n = 7). Thus, the detection limit for technetium (defined as 3 times the standard deviation of the average blank) is 11 fg, and that for plutonium is 0.44 pg. To assess the procedural precision, Canadian Reference Material BL-5 was analyzed routinely with samples. The results of seven replicate analyses for technetium in this standard reference material yield a technetium concentration of 59.0 fg/g, with a remarkably small standard deviation of 0.6 fg, 1.0% of the average value. The results of six replicate analyses for the concentration of plutonium in BL-5 give 1.012 pg/g, with an equally small standard deviation of 0.016, 1.6% of the average value. No direct measure of accuracy can be done on the technetium or plutonium analyses, because no standard reference material exists for these elements. To help constrain the accuracy of our measurements, equilibrium technetium/uranium and plutonium/uranium abundances were calculated using the nuclear reaction code MCNP. For technetium, such calculations are relatively insensitive to variations in model parameters, and measurements fall within a 21% high/low bias. For plutonium, the calculations are very sensitive to model parameters and hence inherently less precise. Indirectly, spike and isotope mix calibrations made from weighted quantities of certified isotopes (both technetium and plutonium) can be used to determine the bias of the measurement system for these elements. These calibrations show that the measurement system is biased by no more than ±1.5%.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号