With the aim of protecting drinking water sources in rural regions, pilot-scale subsurface water flow (SSF) and free water surface flow (FWS) constructed wetland systems were evaluated for removal efficiencies of nitrogenous pollutants in tertiary stage treated wastewaters (effluent from the Pasak?y biological nutrient removal plant). Five different hydraulic application rates and emergent (Canna, Cyperus, Typhia sp., Phragmites sp., Juncus, Poaceae, Paspalum and Iris) and floating (Pistia, Salvina and Lemna) plant species were assayed. The average annual NH4-N, NO3-N and organic-N treatment efficiencies were 81, 40 and 74% in SSFs and 76, 59 and 75% in FWSs, respectively. Two types of the models (first-order plug flow and multiple regression) were tried to estimate the system performances. Nitrification, denitrification and ammonification rate constants (k20) values in SSF and FWS systems were 0.898 d-1 and 0.541 d(-1), 0.486 d(-1) and 0.502 d(-1), 0.986 d(-1) and 0.908, respectively. Results show that the first-order plug flow model clearly estimates slightly higher or lower values than observed when compared with the other model. 相似文献
2.
3.
Guenter Langergraber Klaus Leroch Alexander Pressl Roland Rohrhofer Raimund Haberl 《Water science and technology》2008,57(12):1881-1887
By using a two-stage constructed wetland (CW) system operated with an organic load of 40 gCOD.m(-2).d(-1) (2 m2 per person equivalent) average nitrogen removal efficiencies of about 50% and average nitrogen elimination rates of 980 g N.m(-2).yr(-1) could be achieved. Two vertical flow beds with intermittent loading have been operated in series. The first stage uses sand with a grain size of 2-3.2 mm for the main layer and has a drainage layer that is impounded; the second stage sand with a grain size of 0.06-4 mm and a drainage layer with free drainage. The high nitrogen removal can be achieved without recirculation thus it is possible to operate the two-stage CW system without energy input. The paper shows performance data for the two-stage CW system regarding removal of organic matter and nitrogen for the two year operating period of the system. Additionally, its efficiency is compared with the efficiency of a single-stage vertical flow CW system designed and operated according to the Austrian design standards with 4 m2 per person equivalent. The comparison shows that a higher effluent quality could be reached with the two-stage system although the two-stage CW system is operated with the double organic load or half the specific surface area requirement, respectively. Another advantage is that the specific investment costs of the two-stage CW system amount to 1,200 EUR per person (without mechanical pre-treatment) and are only about 60% of the specific investment costs of the singe-stage CW system. 相似文献
4.
Horizontal subsurface flow constructed wetlands have proven their efficiency in treating wastewater and removing the pollutants of concern. Treatment efficiency depends on the wastewater residence time, which is a function of the hydraulic loading and the physical conditions of the constructed filter system, which can be described with effective parameters such as: hydraulic conductivity, porosity, dispersivity etc. Because spatial variability is often scale dependent, these effective parameters may be affected by the scale of the system being studied. In this paper the results of tracer experiments in constructed filters using saturated horizontal flow at three scales (small and medium lab scales and full-scale system) using the same filter media is reported. Light-weight aggregate (filter media termed Filtralite-P) was used at all scales. Increasing the scale was associated with increasing dispersivity, meanwhile hydraulic conductivity experienced dramatic reduction and variation by increasing the examined scale. Observed changes in the hydraulic parameters indicate that heterogeneity at different scales should be taken into account when the performance of LWA filters are evaluated from small-scale experiments. 相似文献
5.
The bacteriologic treatment efficiency of vertical and horizontal subsurface flow constructed wetlands (SFCWs) was analysed in two multistage wastewater treatment systems by culture dependent and independent methods. When assessed with standard cultivation procedures, bacteria removal efficiency of the vertical and horizontal SFCWs was similar. However, microscopic enumerations of the wastewater bacteria after DNA staining revealed a completely different removal pattern: bacteria removal efficiency of the horizontal SFCWs was in general low and erratic, whereas the vertical SFCWs displayed high bacteria removal rates. The discrepancies in the results obtained by bacteria enumeration and cultivation was due to a strong decrease in bacterial culturability after treatment by the horizontal SFCWs, leading to overestimation of the real bacterial concentrations in these effluents. Additionally, a PCR based approach for the detection of the enteropathogenic bacteria Campylobacter jejuni and Yersinia enterocolitica was tested in the wastewater samples. The methods were specific and reproducible in the analysed samples and could be carried out within 12 h, proving very adequate as an alternative to cultivation. This work recommends a review of the current standard methodology for wastewater quality surveillance, as well as of the design of SFCW. 相似文献
6.
The role of plant uptake on the removal of organic matter and nutrients in subsurface flow constructed wetlands: a simulation study. 总被引:2,自引:0,他引:2
G Langergraber 《Water science and technology》2005,51(9):213-223
Plants in constructed wetlands have several functions related to the treatment processes. It is generally agreed that nutrient uptake is a minor factor in constructed wetlands treating wastewater compared to the loadings applied. For low loaded systems plant uptake can contribute a significant amount to nutrient removal. The contribution of plant uptake is simulated for different qualities of water to be treated using the multi-component reactive transport module CW2D. CW2D is able to describe the biochemical elimination and transformation processes for organic matter, nitrogen and phosphorus in subsurface flow constructed wetlands. The model for plant uptake implemented describes nutrient uptake coupled to water uptake. Literature values are used to calculate potential water and nutrient uptake rates. For a constructed wetland treating municipal wastewater a potential nutrient uptake of about 1.9% of the influent nitrogen and phosphorus load can be expected. For lower loaded systems the potential uptake is significantly higher, e.g. 46% of the nitrogen load for treatment of greywater. The potential uptake rates could only be simulated for high loaded systems i.e. constructed wetlands treating wastewater. For low loaded systems the nutrient concentrations in the liquid phase were too low to simulate the potential uptake rates using the implemented model for plant uptake. 相似文献
7.
F Chazarenc G Maltais-Landry S Troesch Y Comeau J Brisson 《Water science and technology》2007,56(3):23-29
The effect of organic loading, season and plant species on the treatment of fish farm effluent was tested using three-year old mesocosm wetland systems. During one year, nine 1 m2 mesocosms (horizontal subsurface flow), located in a controlled greenhouse environment, were fed with a reconstituted fish farm effluent containing a high fraction of soluble components (1,600 microS/cm and in mg/L: 230 +/- 80 COD, 179 +/- 60 sCOD, 100 +/- 40 TSS, 37 +/- 7 TKN, 14 +/- 2 TP). Combinations of three hydraulic loading rates (30, 60 and 90 L.m(-2) d(-1)) and two plant species (Phragmites australis, Typha angustifolia) and an unplanted control were tested for treatment performance and hydraulic behaviour. Loadings higher than 15 g COD m(-2) d(-1) resulted in a net decrease of hydraulic performances (generation of short circuiting) coupled with low TKN removal. Maximal TKN removal rates (summer: 1.2, winter: 0.6 g.m(-2) d(-1)) were reached in planted units. In all mesocosms, phosphorus was removed during summer (maximal removal rate: 0.3 g TP m(-2) d(-1)) and was released in winter (release rate = approximately half of summer removal rate). This study confirmed that constructed wetlands are susceptible to clogging when treating anaerobic storage tank supernatant rich in highly biodegradable compounds. Contributions of plants to hydraulic efficiency were mainly observed in summer, associated with high evapotranspiration rates. Both plant species gave a similar removal efficiency for all pollutants. 相似文献
8.
Enhancing phosphorus removal in constructed wetlands with ochre from mine drainage treatment. 总被引:3,自引:0,他引:3
K V Heal K E Dobbie E Bozika H McHaffie A E Simpson K A Smith 《Water science and technology》2005,51(9):275-282
No single end-use has yet been identified that is capable of consuming the projected production of ochre (mainly iron (III) oxides) from mine drainage treatment. However, the high sorption capacity of ochre for phosphorus (up to 26 mg kg(-1)) means that it could be used in constructed wetlands to enhance phosphorus removal. Laboratory batch experiments showed that coarse-grained ochre removes 90% of all phosphorus forms from sewage effluent after 15 minutes of shaking. From a larger-scale experiment, it is estimated that constructed wetlands with an ochre substrate should remove phosphorus from sewage effluent for up to 200-300 years. The suitability of ochre for phosphorus removal is being investigated at the field scale in a wastewater constructed wetland (175 m2 area) in Berwickshire, UK. The hydraulic and treatment performance of the wetland were monitored for 15 months prior to installation at the inlet in November 2003 of a tank containing approximately 1200 kg ochre. Results so far show that improved hydraulic design is required for ochre to increase the mean phosphorus removal efficiency of the system (27 +/- 28%), but potentially toxic metals (Al, Cd, Cr, Cu, Fe, Ni, Pb, Zn) have not been released from the ochre into the wetland outflow. 相似文献
9.
Nitrogen elimination from landfill leachates using an extra carbon source in subsurface flow constructed wetlands. 总被引:2,自引:0,他引:2
A three-stage constructed wetland for leachate treatment was monitored on a landfill at a pilot scale. The plant had been designed to achieve at least 75% nitrogen removal. NH4-N input concentration was 240 (median) up to 290 mgl(-1) and COD concentration was 455 to 511 mgl(-1), respectively. A 14 m2 vertical flow sand filter plus a 14 m2 horizontal flow sand filter followed by a 3.3 m2 vertical flow sand filter was chosen. Acetic acid was added to the horizontal flow system for denitrification. The results showed a very stable nitrification rate within the vertical flow system of 94% (median) at NH4-N loading rates of about 10 (median) up to 17 gm(-2)d(-1). Denitrification was mainly dependent on the dosing of acetic acid and could reach a maximum of 98%. One interesting effect was the production of nitrite in the horizontal flow sand filter. This could efficiently be eliminated by the subsequent vertical flow sand filter. The chosen concept proved to be very effective for nitrogen removal. In combination with a final activated carbon filter the COD effluent concentrations could be easily and safely controlled. The design of denitrification reed beds showed a further potential for optimization. 相似文献
10.
The multi-component reactive transport module CW2D has been developed to model transport and reactions of the main constituents of municipal wastewater in subsurface flow constructed wetlands and is able to describe the biochemical elimination and transformation processes for organic matter, nitrogen and phosphorus. It has been shown that simulation results match the measured data when the flow model can be calibrated well. However, there is a need to develop experimental techniques for the measurement of CW2D model parameters to increase the quality of the simulation results. Over the last years methods to characterise the microbial biocoenosis in vertical subsurface flow constructed wetlands have been developed. The paper shows measured data for microbial biomass and their comparison with simulation results using different heterotrophic lysis rate constants. 相似文献
11.
Clogging of subsurface flow (SSF) treatment wetlands from excess biofilm growth is a design problem for which only empirical guidelines exist. A method is proposed to systematically analyse this type of clogging as a design tool. In recognition of the physical reality that most SSF treatment wetland processes are a function of biofilm surface area, a Damk?hler number (Da) definition based on aggregate specific surface area is used to investigate a method of predicting clogging induced by heterotrophic biofilms growing on treatment media. 相似文献
12.
U Bracklow L Manigas A Drews M Vocks M Barjenbruch M Kraume 《Water science and technology》2007,56(6):115-124
For membrane bioreactors (MBR) with enhanced nutrients removal, rather complex recirculation schemes based on the biological requirements are commonly recommended. The aim of this work was to evaluate other recirculation options. For a laboratory scale MBR, four different recirculation schemes were tested. The MBR was operated with COD degradation, nitrification, post-denitrification without carbon dosing and biological phosphorus removal. For all configurations, efficient COD, nitrogen and phosphorus removal could be achieved. There were no big differences in elimination efficiency between the configurations (COD elimination: 96.6-97.9%, nitrogen removal: 89.7-92.1% and phosphorus removal: 97.4-99.4%). Changes in the degradation, release and uptake rates were levelled out by the changes in contact time and biomass distribution. With relatively constant outflow concentrations, different configurations are still interesting with regard to oxygen consumption, simplicity of plant operation or support of certain degradation pathways such as biological phosphorus removal or denitrification. 相似文献
13.
Effective method for feeding an external carbon source (ECS) in SBR was investigated to enhance denitrification based on modifying the anoxic/aerobic sub-cycle for swine wastewater treatment. The wastewater discharged from the scraper-type barns contains relatively low readily biodegradable organic. Therefore NOx-N was accumulated during repeating sub-cycle in SBR operation. When acetic acid was fed as ECS during the final sub-cycle, the maximum nitrogen removal rate was 0.22 kg N/m3/d. This was due to both less denitrification rate during the sub-cycle period and inhibition of denitrification by pH drop during the final cycle. The pH drop was caused by a large amount of ECS feeding to remove high concentration of NOx-N in the final period. To overcome these limitations and achieve higher nitrogen removal rate, the intermittent ECS feeding method with raw wastewater at every anoxic period was developed. Using the modifying ECS feeding method, the removal rate was increased to 0.45 kg N/m3/d without NOx-N accumulation. 相似文献
14.
Njau KN Gastory L Eshton B Katima JH Minja RJ Kimwaga R Shaaban M 《Water science and technology》2011,63(12):3039-3045
The effect of mass transfer on the removal rate constants of BOD5, NH3, NO3 and TKN has been investigated in a Horizontal Subsurface Flow Constructed Wetland (HSSFCW) planted with Phragmites mauritianus. The plug flow model was assumed and the inlet and outlet concentrations were used to determine the observed removal rate constants. Mass transfer effects were studied by assessing the influence of interstitial velocity on pollutant removal rates in CW cells of different widths. The flow velocities varied between 3-46 m/d. Results indicate that the observed removal rate constants are highly influenced by the flow velocity. Correlation of dimensionless groups namely Reynolds Number (Re), Sherwood Number (Sh) and Schmidt Number (Sc) were applied and log-log plots of rate constants against velocity yielded straight lines with values beta = 0.87 for BOD5, 1.88 for NH3, 1.20 for NO3 and 0.94 for TKN. The correlation matched the expected for packed beds although the constant beta was higher than expected for low Reynolds numbers. These results indicate that the design values of rate constants used to size wetlands are influenced by flow velocity. This paper suggests the incorporation of mass transfer into CW design procedures in order to improve the performance of CW systems and reduce land requirements. 相似文献
15.
Total phosphorus (TP) removal in aged constructed wetlands poses a challenge, especially when treated with swine wastewater with high concentrations of phosphorus (P). Our earlier studies with anaerobic lagoon swine wastewater treatment in constructed wetlands showed a decline in P removal (45-22%) with increased years of operation. These particular wetlands have been treated with swine wastewater every year since the first application in 1997. Preliminary lab-scale studies were conducted to evaluate the efficiency of polyaluminium chloride (PAC) in the removal of phosphate-P (PO4-P) from swine wastewater. The experimental objective was to increase the phosphorus treatment efficiency in constructed wetland by adding PAC as a precipitating agent. PAC was added by continuous injection to each wetland system at a rate of 3 L day(-1) (1:5 dilution of concentrated PAC). Swine wastewater was added from an anaerobic lagoon to four constructed wetland cells (11m wide x 40m long) at TP loads of 5.4-6.1 kg ha(-1) day(-1) in two experimental periods, September to November of 2008 and 2009. Treatment efficiency of two wetland systems: marsh-pond-marsh (M-P-M) and continuous marsh (CM) was compared. The wetlands were planted with cattails (Typha latifolia L.) and bulrushes (Scirpus americanus). In 2008, PAC treatment showed an increase of 27.5 and 40.8% of TP removal over control in M-P-M and CM respectively. Similar trend was also observed in the following year. PAC as a flocculant and precipitating agent showed potential to enhance TP removal in constructed wetlands treated with swine wastewater. 相似文献
16.
Hijosa-Valsero M Matamoros V Sidrach-Cardona R Pedescoll A Martín-Villacorta J García J Bayona JM Bécares E 《Water science and technology》2011,63(11):2527-2534
The ability of several mesocosm-scale and full-scale constructed wetlands (CWs) to remove pharmaceuticals and personal care products (PPCPs) from urban wastewater was assessed. The results of three previous works were considered as a whole to find common patterns in PPCP removal. The experiment took place outdoors under winter and summer conditions. The mesocosm-scale CWs differed in some design parameters, namely the presence of plants, the vegetal species chosen (Typha angustifolia versus Phragmites australis), the flow configuration (surface flow versus subsurface flow), the primary treatment (sedimentation tank versus HUSB), the feeding regime (batch flow versus continuous saturation) and the presence of gravel bed. The full-scale CWs consisted of a combination of various subsystems (ponds, surface flow CWs and subsurface flow CWs). The studied PPCPs were ketoprofen, naproxen, ibuprofen, diclofenac, salicylic acid, carbamazepine, caffeine, methyl dihydrojasmonate, galaxolide and tonalide. The performance of the evaluated treatment systems was compound dependent and varied as a function of the CW-configuration. In addition, PPCP removal efficiencies were lower during winter. The presence of plants favoured naproxen, ibuprofen, diclofenac, salicylic acid, caffeine, methyl dihydrojasmonate, galaxolide and tonalide removal. Significant positive correlations were observed between the removal of most PPCPs and temperature or redox potential. Accordingly, microbiological pathways appear to be the most likely degradation route for the target PPCPs in the CWs studied. 相似文献
17.
A Ghermandi D Bixio P Traverso I Cersosimo C Thoeye 《Water science and technology》2007,56(3):207-216
Microbiological quality represents the biggest concern to the reuse of treated wastewater. This paper reports and discusses the results of an international survey on the removal of indicators of microbiological contamination in surface-flow constructed wetlands. Constructed wetlands consistently provide a reduction of 90-99% (1-2 log-removal) in the concentration of indicators such as coliform bacteria and faecal streptococci. This removal is found in wetlands treating water from different types of pretreatment (primary sedimentation, activated sludge, trickling filter, maturation ponds). On the other hand, when the influent is of high microbiological quality, wetlands act as sources of pathogenic contamination. The final water quality, however, is still compatible with medium to no-contact recreational activities and other final water uses. High variability in the effluent quality and seasonality might limit the opportunities for reuse. The role of constructed wetlands in different treatment schemes and the remaining open questions concerning removal mechanisms and reference pathogens are discussed. 相似文献
18.
A primary maturation pond (M1) was spiked with labelled ammonium chloride (15NH4Cl) to track ammonium transformations associated with algal uptake and subsequent sedimentation. Conventional sampling based on grab samples collected from M1 influent, water column and effluent, and processed for unfiltered and filtered TKN, ammonium, nitrite and nitrate, found low total nitrogen removal (8%) and high ammonium nitrogen removal (90%). Stable isotope analysis of 15N from suspended organic and ammonium nitrogen fractions in M1 effluent revealed that labelled ammonium was mainly found in the organic fraction (69% of the 15N recovered), rather than the inorganic fraction (5%). Algal uptake was the predominant pathway for ammonia removal, even though conditions were favourable for ammonia volatilization (8.9 < pH <10.1 units, 15.2 < temperature <18.8 degrees C). Total nitrogen was removed by ammonia volatilization at 15 g N/ha d (3%), organic nitrogen sedimentation at 105 g N/ha d (20%), and in-pond accumulation due to algal uptake at 377 g N/ha d (71%). Algal uptake of ammonium and subsequent sedimentation and retention in the benthic sludge, after partial ammonification of the algal organic nitrogen, is thus likely to be the dominant mechanism for permanent nitrogen removal in maturation ponds during warm summer months in England. 相似文献
19.
ANAMMOX and partial denitritation in anaerobic nitrogen removal from piggery waste. 总被引:14,自引:0,他引:14
The anaerobic ammonium removal from a piggery waste with high strength (56 g COD/L and 5 g T-N/L) was investigated using a lab-scale upflow anaerobic sludge bed reactor at a mesophilic condition. Based on the nitrogen and carbon balance in the process, the contribution of autotrophic and heterotrophic organisms was also evaluated in terms of the influent NO2-N/NH4-N ratio (1:0.8 and 1:1.2 for Phase 1 and Phase 2, respectively). The result of this research demonstrates that the anaerobic ammonium removal from the piggery waste, using the UASB reactor, can be performed successfully. Furthermore, it appears that by using granular sludge as the seed biomass, the ANAMMOX reaction can start more quickly. Average nitrogen conversion was 0.59 kg T-N/m3 reactor-day (0.06 kg T-N/kg VSS/day) and 0.66 kg T-N/m3 reactor-day (0.08 kg T-N/kg VSS/day) for Phase 1 and Phase 2. The NO2-N/NH4-N removal ratio by the ANAMMOX was 1.48 and 1.79 for Phase 1 and Phase 2. The higher nitrite contents (about 50%) in the substrate resulted in higher nitrite nitrogen removal by the partial denitritation, as well as the ANAMMOX reaction, implying higher potential of partial denitritation. However, the result reveals that the ANAMMOX reaction was influenced less by the degree of partial denitritation, and the ANAMMOX bacteria did not compete with denitritation bacteria. The colour of the biomass at the bottom of the reactor changed from dark gray to dark red, which was accompanied by an increase in cytochrome content. At the end of the experiment, red-coloured granular sludge with diameter of 1-2 mm at the lower part of the reactor was also observed. 相似文献