首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In the wake of rising cost of oil and fears of its exhaustion coupled with increased pollution, the governments world-wide are deliberating and making huge strides to promote renewable energy sources such as solar–photovoltaic (solar–PV) and wind energy. Integration of diesel systems with hybrid wind–PV systems is pursued widely to reduce dependence on fossil-fuel produced energy and to reduce the release of carbon gases that cause global climate change. Literature indicates that commercial/residential buildings in the Kingdom of Saudi Arabia (KSA) consume an estimated 10–40% of the total electric energy generated. The study reviews research work carried out world-wide on wind farms and solar parks. The work also analyzes wind speed and solar radiation data of East-Coast (Dhahran), KSA, to assess the technical and economic potential of wind farm and solar PV park (hybrid wind–PV–diesel power systems) to meet the load requirements of a typical commercial building (with annual electrical energy demand of 620,000 kWh). The monthly average wind speeds range from 3.3 to 5.6 m/s. The monthly average daily solar global radiation ranges from 3.61 to 7.96 kWh/m2. The hybrid systems simulated consist of different combinations of 100 kW wind machines, PV panels, supplemented by diesel generators. NREL (and HOMER Energy's) HOMER software has been used to perform the techno-economic study. The simulation results indicate that for a hybrid system comprising of 100 kW wind capacity (37 m hub-height) and 40 kW of PV capacity together with 175 kW diesel system, the renewable energy fraction (with 0% annual capacity shortage) is 36% (24% wind + 12% PV). The cost of generating energy (COE, $/kWh) from this hybrid wind–PV–diesel system has been found to be 0.154 $/kWh (assuming diesel fuel price of 0.1$/L). The study exhibits that for a given hybrid configuration, the number of operational hours of diesel generators decreases with increase in wind farm and PV capacity. Attention has also been focused on wind/PV penetration, un-met load, excess electricity generation, percentage fuel savings and reduction in carbon emissions (relative to diesel-only situation) of different hybrid systems, cost break-down of wind–PV–diesel systems, COE of different hybrid systems, etc.  相似文献   

2.
Shafiqur Rehman  Luai M. Al-Hadhrami   《Energy》2010,35(12):4986-4995
This study presents a PV–diesel hybrid power system with battery backup for a village being fed with diesel generated electricity to displace part of the diesel by solar. The hourly solar radiation data measured at the site along with PV modules mounted on fixed foundations, four generators of different rated powers, diesel prices of 0.2–1.2US$/l, different sizes of batteries and converters were used to find an optimal power system for the village. It was found that a PV array of 2000 kW and four generators of 1250, 750, 2250 and 250 kW; operating at a load factor of 70% required to run for 3317 h/yr, 4242 h/yr, 2820 h/yr and 3150 h/yr, respectively; to produce a mix of 17,640 MWh of electricity annually and 48.33 MWh per day. The cost of energy (COE) of diesel only and PV/diesel/battery power system with 21% solar penetration was found to be 0.190$/kWh and 0.219$/kWh respectively for a diesel price of 0.2$/l. The sensitivity analysis showed that at a diesel price of 0.6$/l the COE from hybrid system become almost the same as that of the diesel only system and above it, the hybrid system become more economical than the diesel only system.  相似文献   

3.
《Applied Energy》2009,86(2):163-169
Solar energy and wind energy are the two most viable renewable energy resources in the world. Good compensation characters are usually found between solar energy and wind energy. This paper recommend an optimal design model for designing hybrid solar–wind systems employing battery banks for calculating the system optimum configurations and ensuring that the annualized cost of the systems is minimized while satisfying the custom required loss of power supply probability (LPSP). The five decision variables included in the optimization process are the PV module number, PV module slope angle, wind turbine number, wind turbine installation height and battery capacity. The proposed method has been applied to design a hybrid system to supply power for a telecommunication relay station along south-east coast of China. The research and project monitoring results of the hybrid project were reported, good complementary characteristics between the solar and wind energy were found, and the hybrid system turned out to be able to perform very well as expected throughout the year with the battery over-discharge situations seldom occurred.  相似文献   

4.
The objective of this study is to evaluate the technical and economic feasibility of stand-alone hybrid photovoltaic (PV)/battery and PV/battery/fuel cell (FC) power systems for a community center comprising 100 households in Kunming by using the Hybrid Optimization Model for Electric Renewable (HOMER) software. HOMER is used to define the optimum sizing and techno-economic feasibility of the system equipment based on the geographical and meteorological data of the study region. In this study, different hybrid power systems are analyzed to select the optimum energy system while considering total net present cost (NPC) and levelized cost of energy (COE). The results showed that the optimal hybrid PV/battery system comprised 500 kW PV modules, 1200 7.6-kWh battery units, and 500 kW power converters. The proposed system has an initial cost of $6,670,000, an annual operating cost of $82,763/yr, a total NPC of $7,727,992, and a levelized COE of $1.536/kWh. While the PV/battery/FC power system is possible, the cost increases were due to the investment cost of the FC system. The optimal PV/battery/FC system has an initial cost of $6,763,000, an annual operating cost of $82,312/yr, a total NPC of $7,815,223, and a levelized COE of $1.553/kWh.  相似文献   

5.
The burning of depleting fossil fuels for power generation has detrimental impact on human life and climate. In view of this, renewable solar energy sources are being increasingly exploited to meet the energy needs. Moreover, solar photovoltaic (PV)–diesel hybrid system technology promises lot of opportunities in remote areas which are far from utility grid and are driven by diesel generators. Integration of PV systems with the diesel plants is being disseminated worldwide to reduce diesel fuel consumption and to minimize atmospheric pollution. The Kingdom of Saudi Arabia (K.S.A.) being endowed with high intensity of solar radiation, is a prospective candidate for deployment of PV systems. Also, K.S.A. has large number of remote scattered villages. The aim of this study is to analyze solar radiation data of Rafha, K.S.A., to assess the techno-economic feasibility of hybrid PV–diesel–battery power systems to meet the load requirements of a typical remote village Rawdhat Bin Habbas (RBH) with annual electrical energy demand of 15,943 MWh. Rafha is located near RBH. The monthly average daily global solar radiation ranges from 3.04 to 7.3 kWh/m2. NREL's HOMER software has been used to perform the techno-economic evaluation. The simulation results indicate that for a hybrid system composed of 2.5 MWp capacity PV system together with 4.5 MW diesel system (three 1.5 MW units) and a battery storage of 1 h of autonomy (equivalent to 1 h of average load), the PV penetration is 27%. The cost of generating energy (COE, US$/kWh) from the above hybrid system has been found to be 0.170$/kWh (assuming diesel fuel price of 0.1$/l). The study exhibits that the operational hours of diesel generators decrease with increase in PV capacity. The investigation also examines the effect of PV/battery penetration on COE, operational hours of diesel gensets. Concurrently, emphasis has been placed on: un-met load, excess electricity generation, percentage fuel savings and reduction in carbon emissions (for different scenarios such as: PV–diesel without storage, PV–diesel with storage, as compared to diesel-only situation), COE of different hybrid systems, etc. The decrease in carbon emissions by using the above hybrid system is about 24% as compared to the diesel-only scenario.  相似文献   

6.
Solar photovoltaic (PV) hybrid system technology is a hot topic for R&D since it promises lot of challenges and opportunities for developed and developing countries. The Kingdom of Saudi Arabia (KSA) being endowed with fairly high degree of solar radiation is a potential candidate for deployment of PV systems for power generation. Literature indicates that commercial/residential buildings in KSA consume an estimated 10–45% of the total electric energy generated. In the present study, solar radiation data of Dhahran (East-Coast, KSA) have been analyzed to assess the techno-economic viability of utilizing hybrid PV–diesel–battery power systems to meet the load requirements of a typical commercial building (with annual electrical energy demand of 620,000 kW h). The monthly average daily solar global radiation ranges from 3.61 to 7.96 kW h/m2. NREL's HOMER software has been used to carry out the techno-economic viability. The simulation results indicate that for a hybrid system comprising of 80 kWp PV system together with 175 kW diesel system and a battery storage of 3 h of autonomy (equivalent to 3 h of average load), the PV penetration is 26%. The cost of generating energy (COE, US$/kW h) from the above hybrid system has been found to be 0.149 $/kW h (assuming diesel fuel price of 0.1 $/L). The study exhibits that for a given hybrid configuration, the operational hours of diesel generators decrease with increase in PV capacity. The investigation also examines the effect of PV/battery penetration on COE, operational hours of diesel gensets for a given hybrid system. Emphasis has also been placed on unmet load, excess electricity generation, percentage fuel savings and reduction in carbon emissions (for different scenarios such as PV–diesel without storage, PV–diesel with storage, as compared to diesel-only situation), cost of PV–diesel–battery systems, COE of different hybrid systems, etc.  相似文献   

7.
The aim of this research is to analyze the techno‐economic performance of hybrid renewable energy system (HRES) using batteries, pumped hydro‐based, and hydrogen‐based storage units at Sharurah, Saudi Arabia. The simulations and optimization process are carried out for nine HRES scenarios to determine the optimum sizes of components for each scenario. The optimal sizing of components for each HRES scenario is determined based on the net present cost (NPC) optimization criterion. All of the nine optimized HRES scenarios are then evaluated based on NPC, levelized cost of energy, payback period, CO2 emissions, excess electricity, and renewable energy fraction. The simulation results show that the photovoltaic (PV)‐diesel‐battery scenario is economically the most viable system with the NPC of US$2.70 million and levelized cost of energy of US$0.178/kWh. Conversely, PV‐diesel‐fuel cell system is proved to be economically the least feasible system. Moreover, the wind‐diesel‐fuel cell is the most economical scenario in the hydrogen‐based storage category. PV‐wind‐diesel‐pumped hydro scenario has the highest renewable energy fraction of 89.8%. PV‐wind‐diesel‐pumped hydro scenario is the most environment‐friendly system, with an 89% reduction in CO2 emissions compared with the base‐case diesel only scenario. Overall, the systems with battery and pumped hydro storage options have shown better techno‐economic performance compared with the systems with hydrogen‐based storage.  相似文献   

8.
Pico-hydro (pH) and photovoltaic (PV) hybrid systems incorporating a biogas generator have been simulated for remote villages in Cameroon using a load of 73 kWh/day and 8.3 kWp. Renewable energy systems were simulated using HOMER, the load profile of a hostel in Cameroon, the solar insolation of Garoua and the flow of river Mungo. For a 40% increase in the cost of imported power system components, the cost of energy was found to be either 0.352 €/kWh for a 5 kW pico-hydro generator with 72 kWh storage or 0.396 €/kWh for a 3 kWp photovoltaic generator with 36 kWh storage. These energy costs were obtained with a biomass resource cost of 25 €/tonne. The pH and PV hybrid systems both required the parallel operation of a 3.3 kW battery inverter with a 10 kW biogas generator. The pH/biogas/battery systems simulated for villages located in the south of Cameroon with a flow rate of at least 92 l/s produced lower energy costs than PV/biogas/battery systems simulated for villages in the north of Cameroon with an insolation level of at least 5.55 kWh/m2/day. For a single-wire grid extension cost of 5000 €/km, operation and maintenance costs of 125 €/yr/km and a grid power price of 0.1 €/kWh, the breakeven grid extension distances were found to be 12.9 km for pH/biogas/battery systems and 15.2 km for PV/biogas/battery systems respectively. Investments in biogas based renewable energy systems could thus be considered in the National Energy Action Plan of Cameroon for the supply of energy to key sectors involved in poverty alleviation.  相似文献   

9.
This study is to search for possibilities of supplying the load demand of Kavakli campus of Kirklareli University with solar energy and the fuel cell power generating system (electrolyzer/hydrogen tank/fuel cell) by using the HOMER software due to the fact that hybrid power systems with renewables can significantly reduce emissions which are caused by utilization of non-renewable power sources. In this study, various hybrid systems will be examined and compared among themselves considering cost of energy (COE), renewable fraction, total net present cost (NPC) and hydrogen production. Additionally, this study will seek whether a fuel cell can be integrated into the hybrid systems. According to the study results, the grid connected systems appear cost-effective as expected. Although the grid-connected photovoltaic (PV) hybrid system has the lowest COE and NPC, the grid-connected PV/fuel cell hybrid system with COE, 0.294$/kWh has a slightly higher cost than the optimum one. It is strongly believed that this system may be chosen because it is a cleaner system and its emissions are fairly low.  相似文献   

10.
This paper presents a methodology to optimise a hybrid solar Photovoltaic—wind turbine generator for the villages situated in the remote areas, especially coastal regions of India. Owing to good insolation and wind density, the hybrid system composed of 6 photovoltaic (PV) modules, one wind turbine and 3 batteries are sufficient to fulfil all the necessary power demand without interruption for an Indian village. The analytical analysis shows that the system having lifespan of 30 years has return on capital, cost of power produced and cost of the hybrid solar-wind generators as 4.08%, € 0.155/kWh and € 4723.5/kWh respectively. The energy payback time is 2.47 years and will lead to earn € 28.52 every year of carbon credits.  相似文献   

11.
Diesel engine power plants are still widely used on many remote islands in South Korea, despite their disadvantages. Aiming to solve economic and environmental pollution problems, a remote island case study was conducted on Ui Island, aiming to offer a zero-emissions solution by using renewable energy sources in an off-grid application. Power was generated from solar, wind, and hydrogen sources. Li-ion batteries and hydrogen were used as energy storage systems. In addition, PV/battery, wind/battery, PV/wind/battery, PV/battery/PEMFC, wind/battery/PEMFC, and PV/wind/battery/PEMFC systems were simulated using the HOMER software to determine the optimal sizes and techno-economic feasibility. The results show that the PV/wind/battery/PEMFC system is the best system. The configuration of the system consists of 990-kW PV panels, 700-kW wind turbines, a 1088-kWh Li-ion battery bank, 534-kW converter, 300-kW PEMWE system, 300-kg hydrogen tank, and 100-kW PEMFC system. The total NPC of the system is $5,276,069, and the LCOE is 0.366 $/kWh.  相似文献   

12.
Off-grid generation options have been simulated for remote villages in Cameroon using a load of 110 kWh/day and 12 kWp. The energy costs of proposed options were simulated using HOMER, a typical village load profile, the solar resource of Garoua and the flow of river Mungo. For a 40% increase in the cost of imported power system components, the cost of energy was found to be 0.296 €/kWh for a micro-hydro hybrid system comprising a 14 kW micro-hydro generator, a 15 kW LPG generator and 36 kWh of battery storage. The cost of energy for photovoltaic (PV) hybrid systems made up of an 18 kWp PV generator, a 15 kW LPG generator and 72 kWh of battery storage was also found to be 0.576 €/kWh for remote petrol price of 1 €/l and LPG price of 0.70 €/m3. The micro-hydro hybrid system proved to be the cheapest option for villages located in the southern parts of Cameroon with a flow rate of at least 200l/s, while the PV hybrid system was the cheapest option for villages in the northern parts of Cameroon with an insolation level of at least 5.55 kWh/m2/day. For a single-wire grid extension cost of 5000 €/km, operation and maintenance costs of 125 €/yr/km and a local grid power price of 0.1 €/kWh, the breakeven grid extension distances were found to be 15.4 km for micro-hydro/LPG generator systems and 37.4 km for PV/LPG generator systems respectively. These results could be used in Cameroon's National Energy Action Plan for the provision of energy services in the key sectors involved in the fight against poverty.  相似文献   

13.
This paper proposes the generation scheduling approach for a microgrid comprised of conventional generators, wind energy generators, solar photovoltaic (PV) systems, battery storage, and electric vehicles. The electrical vehicles (EVs) play two different roles: as load demands during charging, and as storage units to supply energy to remaining load demands in the MG when they are plugged into the microgrid (MG). Wind and solar PV powers are intermittent in nature; hence by including the battery storage and EVs, the MG becomes more stable. Here, the total cost objective is minimized considering the cost of conventional generators, wind generators, solar PV systems and EVs. The proposed optimal scheduling problem is solved using the hybrid differential evolution and harmony search (hybrid DE-HS) algorithm including the wind energy generators and solar PV system along with the battery storage and EVs. Moreover, it requires the least investment.  相似文献   

14.
This paper aims to show the use of the response surface methodology (RSM) in size optimization of an autonomous PV/wind integrated hybrid energy system with battery storage. RSM is a collection of statistical and mathematical methods which relies on optimization of response surface with design parameters. In this study, the response surface, output performance measure, is the hybrid system cost, and the design parameters are the PV size, wind turbine rotor swept area and the battery capacity. The case study is realized in ARENA 10.0, a commercial simulation software, for satisfaction of electricity consumption of the global system for mobile communications (GSM) base station at Izmir Institute of Technology Campus Area, Urla, Turkey. As a result, the optimum PV area, wind turbine rotor swept area, and battery capacity are obtained to be 3.95 m2, 29.4 m2, 31.92 kWh, respectively. These results led to $37,033.9 hybrid energy system cost, including auxiliary energy cost. The optimum result obtained by RSM is confirmed using loss of load probability (LLP) and autonomy analysis.  相似文献   

15.
This paper presents an optimum sizing methodology to optimize the hybrid energy system (HES) configuration based on genetic algorithm. The proposed optimization model has been applied to evaluate the techno‐economic prospective of the HES to meet the load demand of a remote village in the northern part of Saudi Arabia. The optimum configuration is not achieved only by selecting the combination with the lowest cost but also by finding a suitable renewable energy fraction that satisfies load demand requirements with zero rejected loads. Moreover, the economic, technical and environmental characteristics of nine different HES configurations were investigated and weighed against their performance. The simulation results indicated that the optimum wind turbine (WT) selection is not affected only by the WT speed parameters or by the WT rated power but also by the desired renewable energy fraction. It was found that the rated speed of the WT has a significant effect on optimum WT selection, whereas the WT rated power has no consistent effect on optimal WT selection. Moreover, the results clearly indicated that the HES consisting of photovoltaics (PV), WT, battery bank (Batt) and diesel generator (DG) has superiority over all the nine systems studied here in terms of economical and environmental performance. The PV/Batt/DG hybrid system is only feasible when wind resource is very limited and solar energy density is high. On the other hand, the WT/Batt/DG hybrid system is only feasible at high wind speed and low solar energy density. It was also found that the inclusion of batteries reduced the required DG and hence reduced fuel consumption and operating and maintenance cost. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

16.
Integration of wind machines and battery storage with the diesel plants is pursued widely to reduce dependence on fossil fuels. The aim of this study is to assess the impact of battery storage on the economics of hybrid wind‐diesel power systems in commercial applications by analyzing wind‐speed data of Dhahran, East‐Coast, Kingdom of Saudi Arabia (K.S.A.). The annual load of a typical commercial building is 620,000 kWh. The monthly average wind speeds range from 3.3 to 5.6 m/s. The hybrid systems simulated consist of different combinations of 100‐kW commercial wind machines (CWMs) supplemented with battery storage and diesel generators. National Renewable Energy Laboratory's (NREL's) (HOMER Energy's) Hybrid Optimization Model for Electric Renewables (HOMER) software has been employed to perform the economic analysis. The simulation results indicate that for a hybrid system comprising of 100‐kW wind capacity together with 175‐kW diesel system and a battery storage of 4 h of autonomy (i.e. 4 h of average load), the wind penetration (at 37‐m hub height, with 0% annual capacity shortage) is 25%. The cost of generating energy (COE, $/kWh) from this hybrid wind–battery–diesel system has been found to be 0.139 $/kWh (assuming diesel fuel price of 0.1$/L). The investigation examines the effect of wind/battery penetration on: COE, operational hours of diesel gensets. Emphasis has also been placed on un‐met load, excess electricity, fuel savings and reduction in carbon emissions (for wind–diesel without battery storage, wind–diesel with storage, as compared to diesel‐only situation), cost of wind–battery–diesel systems, COE of different hybrid systems, etc. The study addresses benefits of incorporation of short‐term battery storage (in wind–diesel systems) in terms of fuel savings, diesel operation time, carbon emissions, and excess energy. The percentage fuel savings by using above hybrid system is 27% as compared to diesel‐only situation Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

17.
A technico-economic analysis based on integrated modeling, simulation, and optimization approach is used in this study to design an off grid hybrid solar PV/Fuel Cell power system. The main objective is to optimize the design and develop dispatch control strategies of the standalone hybrid renewable power system to meet the desired electric load of a residential community located in a desert region. The effects of temperature and dust accumulation on the solar PV panels on the design and performance of the hybrid power system in a desert region is investigated. The goal of the proposed off-grid hybrid renewable energy system is to increase the penetration of renewable energy in the energy mix, reduce the greenhouse gas emissions from fossil fuel combustion, and lower the cost of energy from the power systems. Simulation, modeling, optimization and dispatch control strategies were used in this study to determine the performance and the cost of the proposed hybrid renewable power system. The simulation results show that the distributed power generation using solar PV and Fuel Cell energy systems integrated with an electrolyzer for hydrogen production and using cycle charging dispatch control strategy (the fuel cell will operate to meet the AC primary load and the surplus of electrical power is used to run the electrolyzer) offers the best performance. The hybrid power system was designed to meet the energy demand of 4500 kWh/day of the residential community (150 houses). The total power production from the distributed hybrid energy system was 52% from the solar PV, and 48% from the fuel cell. From the total electricity generated from the photovoltaic hydrogen fuel cell hybrid system, 80.70% is used to meet all the AC load of the residential community with negligible unmet AC primary load (0.08%), 14.08% is the input DC power for the electrolyzer for hydrogen production, 3.30% are the losses in the DC/AC inverter, and 1.84% is the excess power (dumped energy). The proposed off-grid hybrid renewable power system has 40.2% renewable fraction, is economically viable with a levelized cost of energy of 145 $/MWh and is environmentally friendly (zero carbon dioxide emissions during the electricity generation from the solar PV and Fuel Cell hybrid power system).  相似文献   

18.
In this study, a hybrid system consisted of 10 kW wind and 1 kWp PV array is built to meet the load demand of a raise chucker partridge raising facility by renewable energy sources. The facility has an average energy consumption of about 20.33 kWh/day, with a peak demand of 2.4 kW. The solar radiation data and wind data of the region are analyzed for sizing of the renewable energy system. The performance of each alternative system is examined in terms of energy efficiency, and H2 production capacity of the hybrid system from due to excessive electrical energy is studied. A Matlab-Simulink Software is used for analyzing the system performance. The average range of state of charge varies between 56.6% and 88.3% monthly from April to July. The amount of hydrogen production by excess electricity is 14.4 kg in the month of July, due to the high wind speed and solar radiation. Energy efficiency of the electrolyser is found to be varying between 64% and 70% percent. Energy efficiency of each hybrid system is calculated. The overall energy efficiency of wind-electrolyser system varies between 5% and 14% while the energy efficiency of PV-electrolyser system changes within a narrower range, as between 7.9% to and 8.5%, respectively.  相似文献   

19.
There is a constant growth in energy consumption and consequently energy generation around the world. During the recent decades, renewable energy sources took heed of scientists and policy makers as a remedy for substituting traditional sources. Wind and photovoltaic (PV) are the least reliable sources because of their dependence on wind speed and irradiance and therefore their intermittent nature. Energy storage systems are usually coupled with these sources to increase the reliability of the hybrid system. Environmental effects are one of the biggest concerns associated with the renewable energy sources. This study summarizes the last and most important environmental and economic analysis of a grid‐connected hybrid network consisting of wind turbine, PV panels, and energy storage systems. Focusing on environmental aspects, this paper reviews land efficiency, shaded analysis of wind turbines and PV panels, greenhouse gas emission, wastes of wind turbine and PV panels' components, fossil fuel consumption, wildlife, sensitive ecosystems, health benefits, and so on. A cost analysis of the energy generated by a hybrid system has been discussed. Furthermore, this study reviews the latest technologies for materials that have been used for solar PV manufacturing. This paper can help to make a right decision considering all aspects of installing a hybrid system. Copyright © 2017 John Wiley & Sons, Ltd.  相似文献   

20.
Wind–PV–diesel hybrid power generation system technology is a promising energy option since it provides opportunities for developed and developing countries to harness naturally available, inexhaustible and pollution-less resources. The aim of this study is to assess the techno-economic feasibility of utilizing a hybrid wind–PV–diesel power system to meet the load of Al Hallaniyat Island. Hybrid Optimization Model for Electric Renewables software has been employed to carry out the present study. The simulation results indicate that the cost of generating energy (COE) is $0.222 kWh?1 for a hybrid system composed of a 70 kW PV system, 60 kW wind turbine and batteries together with a 324.8 kW diesel system. Moreover, using the same system but without batteries will increase the COE to $0.225 kWh?1, the fuel consumption, the excess energy and the total operating hours for the diesel generators. The PV–wind hybrid option is techno-economically viable for rural electrification.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号