首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The authors studied the intraocular pressure (IOP) changes after phacoemulsification with two different kinds of foldable silicone lens implantation using Healon GV as viscoelastic substance. One hundred patients undergoing cataract surgery were enrolled in this study. Inclusion criteria were: absence of ocular hypertension or glaucoma. Patients were randomly assigned to plate haptic (Silens PH, Domilens Chiron Vision, Lyon, France) or three-piece (CeeOntrade mark& ;920, Pharmacia spa, Milano, Italia) silicone intraocular lens (IOL) implantation. Following phacoemulsification and cortical aspiration, the capsular bag was reinflated with Healon GV. After foldable silicone IOL insertion residual Healon GV was removed from the anterior chamber. IOP was measured preoperatively and at 6, 24 h and 1 week postoperatively. Six hours postoperatively IOP was higher in the Silens PH group than in the CeeOn group (20. 85+/-5.42 vs. 18.88+/-2.95 mm Hg, p= 0.026). The difference was confirmed after 24 h (21.02+/-5.18 vs. 17.34+/-3.18 mm Hg, p < 0.01). Despite the medical treatment (acetazolamide 250 mg orally every 6 h), at the 24-hour control 2 eyes with plate haptic silicone lens showed IOP values higher than 30 mm Hg. Slitlamp examination showed in both eyes a shallowing of the anterior chamber together with the evidence of capsular bag hyperdistension and capsular block resulting from the occlusion of the circular anterior capsule opening by the plate haptic IOL. Residual Healon GV removal from the anterior chamber was performed. At 1-week control both eyes showed normalization of IOP. The use of a plate haptic silicone lens may be associated with a more consistent retention of Healon GV in the eye with trapping in the capsular bag. Retained viscoelastic may cause either trabecular meshwork blockage by viscoelastic substance or postoperative capsular bag hyperdistension, anteroplacement of the IOL optic and capsular block from occlusion of the circular anterior opening by the IOL optic.  相似文献   

2.
Repeated topical administration of 2.5% trifluormethazolamide, a halogenated derivative of methazolamide, resulted in a unilateral decrease in intraocular pressure in rabbits. Mean (+/- S.E.M.) baseline intraocular pressure (19.8 +/- 2.1 mm Hg) was significantly (P less than .05) decreased 30 minutes (16.1 +/- 2.2 mm Hg) and 60 minutes (15.8 +/- 2.7 mm Hg) after drug administration. Trifluormethazolamide did not alter outflow facility. Aqueous humor flow calculated from the tonographic data was reduced 44% and flow measured by fluorophotometry was reduced 29%. Topical delivery of trifluormethazolamide decreased the level of carbon dioxide in the aqueous humor in the treated eye in a manner similar to that observed after systemic administration of carbonic anhydrase inhibitors. Topical administration of 10% acetazolamide did not decrease intraocular pressure. However, topical administration of either trifluormethazolamide or acetazolamide before oral administration of water resulted in a blunting of the water-induced ocular hypertensive response.  相似文献   

3.
Aqueous humor flow was calculated during day-time in 148 healthy volunteers and 75 older patients using the Fluorotron Master II anterior chamber protocol (Coherent, Palo Alto, USA). Healthy volunteers as well as patients had no history of ocular pathology, surgery or laser treatment. Slitlamp examination revealed no ocular pathology. Hypertension, diabetes, local and systemic drug therapy, neoplasia, kidney or liver disease, contact lens and ocular trauma were excluded. Mean age of volunteers was 26.5 +/- 3.8 years; age of patients: 65.5 +/- 10.5 years. Aqueous humor flow during day-time in healthy volunteers in the OD: (mean +/- s.d.) 2.26 +/- 1.0 microliters/min, in the OS: 2.17 +/- 1.0 microliters/min, OS: 1.86 +/- 1.1 Ml/min. Correlation coefficient: r = 0.8. The mean aqueous humor flow in the older patients during day-time: OD: 1.91 +/- 1.1 microliters/min. Correlation coefficient: r = 0.54. The Mann-Whitney-U-test revealed a significant difference when comparing the right eyes of healthy volunteers with the right eyes of patients (p < 0.01). When comparing all left eyes the difference is also significant (p = 0.01). The results of the study underline, that the mean aqueous humor secretion does significantly decrease with age. However, the data show that there is only a slight decrease of flow of approximately 2.5% per decade. From the clinical point of view it should be concluded, that although the aqueous humor secretion does decrease with age, this is not of clinical importance, even in cases of glaucoma surgery.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

4.
Oxygen tension and potential difference were measured in the gastric mucosa of anesthetized dogs with an ultramicroelectrode technqiue while total blood flow and arteriovenous oxygen content difference were measured. In the control period, measurements were: gastric blood flow, 102.4 +/- 3.0 ml per min per 100 g of tissue; calculated oxygen consumption, 2.4 +/- 0.1 ml per min per 100 g of tissue; intracellular oxygen tension, 15.0 +/- 0.6 mm Hg; and intracellular potential difference, -50.8 +/- 1.5 mv. When gastric blood flow was reduced 50% by tourniquet ischemia, oxygen tension decreased 20% (P less than 0.05) but electrical potential and oxygen consumption did not change. When blood flow was reduced 75%, oxygen tension and potential difference decreased significantly, 60% and 35%, respectively, but oxygen consumption was unchanged. Zero blood flow reduced oxygen tension, electrical potential, and total oxygen consumption to zero; release of the arterial tourniquet allowed them to return to control levels. The critical oxygen tension at which the electromotive force generated by the gastric mucosal cells was reduced averaged 9 mm Hg. This suggests that safety factors exist in the gastric circulation which permit a 60% reduction in total gastric blood flow to occur before an insufficiency of intracellular oxygen begins to limit cellular metabolism within the mucosa.  相似文献   

5.
The ocular dimensions and refraction of the eye were measured for accommodation stimulus levels of 0.0, 1.5, 3.5, 5.5, and 8.0 D for 11 subjects aged 18 to 28 years, mean 21.2 +/- 2.62 years using keratometry, autorefraction, A-Scan ultrasonography, and video phakometry techniques. The subjects had refractive errors in the range + 0.50 to -4.25 D, mean -1.88 +/- 1.64 D. With the maximum level of accommodation the anterior chamber depth decreased by 0.23 +/- 0.09 mm, the lens thickness increased by 0.28 +/- 0.09 mm, and no significant differences were recorded in axial length or vitreous chamber depth. The radius of curvature of the anterior surface of the crystalline lens decreased from 11.54 +/- 1.27 to 6.59 +/- 0.97 mm and the posterior surface from -6.67 +/- 0.97 to -5.30 +/- 0.4 mm. We determined the equivalent refractive index to be 1.4277 +/- 0.0011, with no significant differences at different levels of accommodation. When the crystalline lens was modeled as a gradient refractive index (GRIN) structure with elliptical iso-indicial lines, the mean surface refractive index of the lens was 1.3859 +/- 0.0009 for an assumed central refractive index of 1.406. The power of the anterior surface of the lens increased from 4.38 +/- 0.49 to 7.59 +/- 0.34 D, the posterior surface increased from 7.67 +/- 1.28 to 9.32 +/- 0.64 D, and the GRIN power increased from 9.70 +/- 1.31 to 13.74 +/- 0.77 D for the maximum accommodative stimulus of 8.00 D. On the basis of the model used, a substantial part of the increase in power of the crystalline lens with accommodation resulted from the change in refractive index distribution within the lens.  相似文献   

6.
Propofol decreases intraocular pressure (IOP) and the IOP response to laryngoscopy and intubation, but the mechanisms responsible for this effect have not been reported. The present study examined the effect of propofol on IOP, intraocular fluid formation and outflow facility, and intraocular compliance. Twenty-two white New Zealand rabbits were anesthetized with halothane (0.8%-1.0% inspired concentration) in nitrous oxide (2 L/min) and oxygen (1 L/min). Muscle paralysis was established with pancuronium, and the lungs were mechanically ventilated through a tracheal tube. Twelve rabbits examined under these conditions served as controls. In the treatment group (n = 10), 6 mg/kg propofol followed by 18 mg.kg-1 x h-1 propofol intravenously was added to halothane/nitrous oxide/oxygen anesthesia. In both groups, a series of intraocular infusions was made via a 30-gauge needle in the anterior chamber, and IOP, the rate of aqueous humor formation (Fa), and trabecular outflow facility (Ctr) were determined using conventional analysis. These same measures, as well as intraocular compliance, were determined using a new method of analysis adapted from the manometric technique for determining cerebrospinal fluid dynamics. IOP was 11.3 +/- 1.8 mm Hg (mean +/- SD) in halothane-anesthetized controls and decreased to 9.4 +/- 2.2 mm Hg when propofol was added to halothane anesthesia (P < 0.05). By conventional analysis, Fa was 2.82 +/- 0.94 microL/min and Ctr was 0.121 +/- 0.044 microL.min-1 x mm Hg-1 in controls. After addition of propofol, Fa decreased by 24% to 2.15 +/- 0.62 microL/min (P < 0.05) and Ctr decreased by 18% to 0.099 +/- 0.034 microL.min-1 x mm Hg-1 (P < 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

7.
OBJECTIVES: The efficacy of selective synchronized suction and retroinfusion of coronary veins was compared with synchronized coronary venous retroperfusion in preventing ischemic reduction of regional myocardial function and myocardial oxygen tension. BACKGROUND: Because incomplete protection by synchronized coronary venous retroperfusion during ischemia might result from nonselective retroinfusion and only passive drainage of the veins, a suction device was added to a retroinfusion system. METHODS: Regional myocardial function (ultrasonic crystals) and myocardial oxygen tension (polarographic electrodes) were studied in 30 pigs during 10-min occlusion of the left anterior descending coronary artery (ischemia), followed by reperfusion. During ischemia, group A (n = 10) was supported by selective synchronized suction and retroinfusion; group B (n = 10) was supported by synchronized coronary venous retroperfusion, and group C (n = 10) was not supported by retroinfusion. RESULTS: In group A, subendocardial segment shortening decreased from 21 +/- 4% (mean +/- SD) before ischemia to 11 +/- 5% during ischemia. In contrast, systolic dyskinesia was observed in group B (-2 +/- 4%, p < 0.001) and group C (-2 +/- 5%, p < 0.001). During ischemia, the decrease in intramyocardial oxygen tension was less pronounced in group A (41 +/- 15 vs. 27 +/- 12 mm Hg) than in group B (40 +/- 10 vs. 19 +/- 10 mm Hg, p = 0.1) or group C (33 +/- 11 vs. 12 +/- 8 mm Hg, p = 0.002). During ischemia, myocardial surface oxygen tension was preserved > 0 mm Hg only in group A. CONCLUSIONS: Preservation of regional myocardial function and myocardial oxygen tension was substantially higher by selective synchronized suction and retroinfusion of coronary veins than by synchronized coronary venous retroperfusion in pigs.  相似文献   

8.
OBJECTIVE: To compare the short-term and long-term efficacy of using releasable sutures vs conventional interrupted sutures for scleral flap suturing in trabeculectomy. DESIGN: A prospective randomized study. SETTING: A university-affiliated referral eye hospital. PATIENTS: Thirty consecutive patients requiring trabeculectomy for uncontrolled primary glaucoma. INTERVENTION: Fifteen patients underwent trabeculectomy with permanent interrupted sutures; the same number underwent trabeculectomy with releasable sutures. MAIN OUTCOME MEASURES: Incidence of short-term shallowing of anterior chamber or hypotony and related complications, and long-term intraocular pressure control and bleb score. RESULTS: The mean percentage reduction in intraocular pressure on day 1 in the group with releasable sutures was 55.2%, while only a 0.8% reduction in anterior chamber depth was noted. This compared with figures of 59.3% and 10.1%, respectively, in the group without releasable sutures. Hypotony (intraocular pressure < or =6 mm Hg) was noted in 8 (53%) of cases without releasable sutures and 3 (20%) of cases with releasable sutures. Shallow anterior chamber (central anterior chamber depth, < or =1 mm) was noted in 5 (33%) of cases without releasable sutures and 1 (7%) of cases with releasable sutures. The mean +/- SD final bleb score was 5.4 +/- 0.3 in the group with releasable sutures compared with 4.2 +/- 0.6 in the group without releasable sutures (P<.001). The mean +/- SD final intraocular pressure at the end of 12 months was 16.9 +/- 1.2 mm Hg in the group without releasable sutures and 15.0 +/- 0.9 mm Hg in the group with releasable sutures (P<.001). Final intraocular pressure was controlled (intraocular pressure < or =21 mm Hg) in all patients in the group with releasable sutures, giving a success rate of 100%, and in 12 patients in the group without releasable sutures, giving a success rate of 80%. CONCLUSIONS: Use of releasable sutures is an effective way at no extra cost or instrumentation to maximize the long-term bleb score and lower intraocular pressure, and to minimize the short-term complications of trabeculectomy.  相似文献   

9.
PURPOSE: To ascertain whether phacoemulsification with posterior chamber intraocular lens (IOL) implantation causes long-term reduction in intraocular pressure (IOP). SETTING: Private practice, Kempten, Germany. METHODS: Intraocular pressure was measured in both eyes of 120 consecutive patients who were unilaterally phakic after phacoemulsification a mean of 17 months +/- 17 (SD) previously. Mean age of the 36 men and 84 women was 76 +/- 10 years. Data were analyzed using binomial distribution and the Wilcoxon signed-rank test. RESULTS: The median ratio of IOP in the pseudophakic eye to IOP in the phakic eye was 0.83. The IOP was lower in the pseudophakic eye in 96 patients (80%). The median IOP was 12 mm Hg in the pseudophakic eyes and 14 mm Hg in the phakic eyes (P < .001). As measured by the interquartile range, IOP distribution was more centered in the pseudophakic than in the phakic eyes (3 versus 4). The IOP in the pseudophakic eyes remained lower to the last measurement, 5 years postoperatively, and appeared to be independent of patient age. Lower IOP in the pseudophakic eye was consistently present in patients with higher IOP in the phakic eye (16 to 22 mm Hg). CONCLUSION: Phacoemulsification with posterior chamber IOL implantation reduced IOP in most but not all patients with a preoperative IOP of 22 mm Hg or less. This reduction was maintained over several years, with the cause yet to be established. Lower IOP may decrease the risk of subsequent glaucomatous nerve damage in these patients.  相似文献   

10.
OBJECTIVE: To evaluate the effects of 8-iso prostaglandin E2 (8-iso PGE2; prosta-5,13-dien-1-oic acid,11,15-dihydroxy-9-oxo-,[5Z,8beta-11X,13E,15 S]-) on the intraocular pressure (IOP), outflow facility, and aqueous humor flow rates in normal monkeys and monkeys with glaucoma. METHODS: The IOP was measured before and as long as 6 hours after the topical application of 8-iso PGE2 to 1 eye of 6 normal monkeys and to the glaucomatous eye of 8 monkeys with unilateral laser-induced glaucoma. The pupil diameter was measured at the same times as the IOP measurements in the normal monkeys. Tonographic outflow facility and fluorophotometric flow rates of aqueous humor were measured in 6 normal monkeys before and after drug treatment. RESULTS: In normal monkeys, a single dose of 0.1% 8-iso PGE2 reduced (P<.01) the IOP for 4 hours in the treated eyes with a maximum (mean +/- SEM) reduction of 3.2 +/- 0.2 mm Hg, compared with the contralateral control eyes. The pupil size was smaller (P<.01) in the treated eyes by as much as 1.0 +/- 0.2 mm for 4 hours. In 8 glaucomatous monkey eyes, the application of 0.05% and 0.1% 8-iso PGE2 reduced the IOP (P<.01) for as long as 2 and 5 hours, respectively. The maximum reduction in the IOP was 4.6 +/- 0.8 mm Hg (0.05%) and 6.0 +/- 0.8 mm Hg (0.1%) compared with baseline measurements. The magnitude and duration of the ocular hypotensive effect were enhanced with twice-a-day administration for 5 consecutive days. Outflow facility in normal monkey eyes was increased (P<.05) by 48% in the treated eyes, and aqueous humor flow was unchanged (P>.10), compared with vehicle-treated contralateral control eyes. Mild eyelid edema, conjunctival edema, hyperemia, and discharge appeared in some eyes treated with the 0.1% drug concentration. CONCLUSIONS: The use of 8-iso PGE2 reduces the IOP in both normal and glaucomatous monkey eyes. An increase in outflow facility appears to account for most of the IOP reduction in normal monkeys. Clinical Relevance: The application of 8-iso PGE2 may have potential for the treatment of glaucoma as an outflow facility-increasing drug.  相似文献   

11.
PURPOSE: To investigate if part of the progressive reduction of intraocular pressure (IOP), seen when physostigmine is applied on alternate hours, is due to a reduced aqueous flow. METHODS: In a randomized, open study, one drop of physostigmine salicylate, 8 mg/ml, was instilled at 7 AM in one randomly assigned eye in each of twenty healthy volunteers. Instillations were repeated on alternate hours throughout the day. Each subject's untreated eye served as control. Fluorophotometry of the anterior segment was performed hourly between 7 Am and 8 PM and aqueous flow was calculated. Subsequently, the subjects underwent tomography and tonometry. The change in anterior chamber depth and volume induced by physostigmine was assessed separately. RESULTS: The mean aqueous flow during the day was 25-28% higher in the physostigmine-treated eye than in the control eye. The difference was statistically significant from 9 AM (p < 0.05-p < 0.001). Each dose caused a further increase. The mean outflow facility increased by 0.14 microliters/min/mm Hg with 95% confidence interval (CI) 0.09-0.18. Although the increase in outflow facility was small, there was a marked reduction of IOP with a mean difference between treated and untreated eye of 3.2 mm Hg (95% CI: 2.3-4.0). CONCLUSIONS: Repeated administrations of physostigmine increase the aqueous flow and outflow facility. The combined effect is a marked reduction of IOP.  相似文献   

12.
OBJECTIVE: To determine the biometric findings of ocular structures in primary angle-closure glaucoma (PACG). DESIGN: An observational case series with comparisons among three groups (patients with acute/intermittent PACG [A/I-PACG], patients with chronic PACG [C-PACG], and normal subjects [N]). PARTICIPANTS: A total of 54 white patients with PACG (13 male, 41 female) were studied: 10 with acute, 22 with intermittent, and 22 with chronic types of PACG. Forty-two normal white subjects (11 male, 31 female) were studied as control subjects. Only one eye was considered in each patient or subject. TESTING: Ultrasound biomicroscopy (UBM) and standardized A-scan ultrasonography (immersion technique) were performed in each patient during the same session or within 1 to 3 days. MAIN OUTCOME MEASURES: The following A-scan parameters were measured: anterior chamber depth (ACD), lens thickness (LT), axial length (AL), lens/axial length factor (LAF), and relative lens position (RLP). Ten UBM parameters were measured, the most important of which were anterior chamber angle, trabecular-ciliary process distance (TCPD), angle opening distance at 500 microm from the scleral spur (AOD 500), and scleral-ciliary process angle (SCPA). RESULTS: Compared to normal subjects, the patients with PACG presented a shorter AL (A/I-PACG = 22.31 +/- 0.83 mm, C-PACG = 22.27 +/- 0.94 mm, N = 23.38 +/- 1.23 mm), a shallower ACD (A/I-PACG = 2.41 +/- 0.25 mm, C-PACG = 2.77 +/- 0.31 mm, N = 3.33 +/- 0.31 mm), a thicker lens (A/I-PACG = 5.10 +/- 0.33 mm, C-PACG = 4.92 +/- 0.27 mm, N = 4.60 +/- 0.53 mm), and a more anteriorly located lens (RLP values, A/I-PACG = 2.22 +/- 0.12, C-PACG = 2.34 +/- 0.16, N = 2.41 +/- 0.15). The LAF values in A/I-PACG, C-PACG, and N were 2.28 +/- 012, 2.20 +/- 0.11, and 1.97 +/- 0.12, respectively. Anterior chamber angle (A/I-PACG = 11.72 +/- 8.84, C-PACG = 19.87 +/- 9.83, N = 31.29 +/- 9.18 degrees) and SCPA (A/I-PACG = 28.71 +/- 4.02, C-PACG = 30.87 +/- 6.04, N = 53.13 +/- 9.58 degrees) were narrower, TCPD (A/I-PACG = 0.61 +/- 0.12 mm, C-PACG = 0.71 +/- 0.14 mm, N = 1.08 +/- 0.22 mm) and AOD 500 shorter (A/I-PACG = 0.13 +/- 0.09 mm, C-PACG = 0.21 +/- 0.10 mm, N = 0.36 +/- 0.11 mm) in patients with PACG. All the biometric differences proved statistically significant using the one-way analysis-of-variance test. CONCLUSIONS: In patients with PACG, the anterior segment is more crowded because of the presence of a thicker, more anteriorly located lens. The UBM confirms this crowding of the anterior segment, showing the forward rotation of the ciliary processes. A gradual progressive shift in anatomic characteristics is discernible on passing from normal to chronic PACG and then to acute/intermittent PACG eyes.  相似文献   

13.
BACKGROUND: Aqueous humor flow through the anterior chamber of the eye undergoes a circadian cycle. The rate of flow during the day is twice as high as the rate of flow at night. The pineal hormone, melatonin, also undergoes a circadian cycle. Melatonin levels are high at night, whereas aqueous humor flow is low. The authors studied the effect of oral melatonin on aqueous humor flow in humans. METHODS: The effect of melatonin on aqueous humor flow was evaluated in 19 healthy human volunteers in a randomized, masked crossover study with a placebo control. The hormone or placebo was administered orally during the day when endogenous levels of melatonin are low. Aqueous flow was measured by fluorophotometry for 8 hours. RESULTS: The mean rate of flow during melatonin treatment was 2.71 +/- 0.64 microliters/minute (+/- standard deviation). The rate of flow during placebo treatment was 2.80 +/- 0.66 microliters/minute. There is no statistically significant difference between these two rates (P = 0.4). With a sample size of 19, the study has a power of 92% to detect at least a 15% difference in the rate of flow under the two conditions. Measurement of plasma concentration of melatonin in five subjects confirmed that concentrations after oral dosage reached peaks comparable with the normal endogenous nocturnal peaks. CONCLUSIONS: The authors conclude that melatonin concentrations during the day, comparable with plasma concentrations that occur spontaneously during sleep, do not suppress aqueous humor formation. The authors find no support for the idea that plasma melatonin, per se, can suppress aqueous formation or that the circadian rhythm of plasma melatonin is primarily responsible for the circadian rhythm of aqueous humor flow.  相似文献   

14.
OBJECTIVE: Considerable evidence exists to suggest that tumor hypoxia results in radioresistance. Historically, it has been difficult to assess tumor oxygen tension levels reliably. These levels can now be assessed in head and neck malignancies using the Eppendorf pO2 histograph, which uses a fine-needle electrode and a computerized micromanipulator. This technology was used to compare the pretreatment tumor oxygen tension level in lymph node metastases of patients with head and neck cancer to measurements taken during nonsurgical treatment after a partial response had been achieved. STUDY DESIGN: Prospective study. METHODS: Oxygen tension levels were measured in the cervical lymph nodes of 10 patients with biopsy-proven head and neck squamous cell carcinoma and cervical metastases who were being treated with nonsurgical management. These levels were obtained using the Eppendorf pO2 histograph system. Measurements were taken before the start of treatment and were repeated when the size of the cervical metastatic node had decreased by 50%. Normal subcutaneous tissue was measured during the same session. The mean and median pO2 levels, as well as the percentage of measurements with pO2 less than 5 mm Hg were determined. RESULTS: A mean of 72.6 measurements per session was taken from each lymph node. The median tumor pO2 measurement fell from a mean (+/-SD) of 13.9+/-8.0 mm Hg to 7.3+/-9.9 mm Hg. Even more dramatic, however, was the substantial increase in the percentage of values less than 5 mm Hg, a rise from 29% to 52%. CONCLUSIONS: While there is variability both in the pretreatment oxygenation of head and neck cervical metastases and in the change in tumor oxygen tension during treatment, there appears to be a decrease in the overall oxygenation of the tumors. The dramatic increase in very low oxygen measurements may reflect selective survival of radioresistant or chemoresistant hypoxic tumor cells. Cells at the very low level would be expected to be radiobiologically hypoxic (resistant to radiation-induced cell kill).  相似文献   

15.
The pharmacologic effects of prostaglandin E2 (PGE2) on the anterior ocular segment were investigated. PGE2 was administered with a glass cylinder attached to the cornea in concentrations ranging from 0.05 to 500 micrograms/ml. The intraocular inflammatory reaction was assessed according to the changes in the anterior chamber flare, ocular tension, and components of the aqueous humor. We also performed experiments designed to inhibit the reactions induced by PGE2 using anti-inflammatory agents. The PGE2 elicited a single peak reaction in the anterior chamber flare, which recovered after several hours, and a transient elevation in the ocular tension in the early stage after PGE2 administration. Quantitative analysis of these two reactions revealed that both were dependent on the dose of PGE2 administered. The concentrations of ascorbic acid and glutathione, particularly that of the reduced form of the latter, were transiently reduced in the aqueous humor. The anterior chamber flares were suppressed by agents that inhibit arachdonic acid metabolism. These findings suggest that the metabolism of arachdonic acid becomes newly activated as a result of stimulation by PGE2 of extrinsic origin.  相似文献   

16.
BACKGROUND: Consistent clinical results have not been achieved when lung preservation times exceed 6 hours. The aim of this study was to use an alternative normothermic autoperfusion technique for lung preservation and transplantation. METHODS: In six paired dogs, donor lungs were removed, along with the heart, liver, pancreas, duodenum, and both kidneys, and were preserved for 24 to 33 hours in a normothermic autoperfused multiple organ block. Orthotopic left lung transplantation was performed at the end of the preservation period. RESULTS: Lung function was good during the preservation period. With a gas mixture of 50% O2 + 3% CO2 + 47% N2 delivered to the multiorgan block, arterial oxygen tension ranged from 331 +/- 19 to 383 +/- 8 mm Hg; carbon dioxide tension ranged from 18 +/- 5 to 32 +/- 5 mm Hg; and pH ranged from 7.36 +/- 0.02 to 7.45 +/- 0.08. After transplantation, the dogs were kept anesthetized and ventilated for 24 hours with the same gas mixture. The opposite pulmonary artery was occluded 0 to 6 hours after transplantation. Arterial blood pressures were stable after surgery. Arterial oxygen tension was maintained between 205 +/- 39 and 320 +/- 57 mm Hg, and arterial carbon dioxide tension was maintained between 23 +/- 2 and 34 +/- 2 mm Hg. Lung tissue wet/dry weight ratio was 4.94 +/- 0.17 after preservation; this ratio did not differ from that found in normal controls (4.91 +/- 0.10). CONCLUSIONS: This study shows that the lungs were well preserved for more than 24 hours of preservation when the normothermic multiorgan block preparation was used. The transplanted left lung was able to support the anesthetized dog after the opposite pulmonary artery was occluded.  相似文献   

17.
Polymethylmethacrylate (PMMA) contact lenses can alter corneal shape and induce corneal warpage or distortion. The purpose of our study was to determine the effects on the corneal topography after immediate refitting of long-term PMMA contact lens wearers into rigid gas permeable (RGP) materials. Six eyes with contact lens induced corneal warpage from PMMA contact lenses were assessed using the Topographical Mapping System-1. Statistical analysis was performed for the following variables prior to and approximately 6 months after contact lens refitting: best spectacle visual acuity, manifest refraction, surface regularity index, surface asymmetry index, keratometry, and simulated keratometry. Best spectacle visual acuity improved an average of 1.8 +/- 1.0 (mean +/- SD, P < 0.05) lines of Snellen visual acuity, while refraction did not change appreciably. The surface regularity index diminished by 0.51 +/- 0.32 (P = 0.01). The surface asymmetry index improved by 0.32 +/- 0.26 (P < 0.05). There was a good correlation between keratometry and simulated keratometry, and neither changed significantly after refitting with RGP contact lenses. All general topographic patterns remained unchanged throughout the study. Immediate refitting of long-term PMMA contact lens wearers into RGP materials of similar fit allows a slightly more regular and symmetric central corneal shape, which can result in improved spectacle visual acuity. The general corneal topographic patterns of contact lens induced corneal warpage did not change or improve after refitting to RGP material.  相似文献   

18.
The oxygen tension (PO2) in the renal cortex and outer renal medulla in 26 rats was studied by use of oxygen microelectrodes before and after injection of x-ray contrast media (CM). The CM, iopromide, ioxaglate and iotrolan were administrated intravenously in iodine equivalent doses (1,600 mg iodine/kg body wt). Ringer's solution was used as the control. In the outer medulla, all three CM induced a decrease in PO2: iopromide (N = 6) from 30 +/- 3 to 18 +/- 4 mm Hg; ioxaglate (N = 7) from 32 +/- 6 to 15 +/- 4 mm Hg; and iotrolan (N = 6) from 36 +/- 3 to 14 +/- 4 mm Hg. All these decreases were significant. After the injection of Ringer's (N = 7) there was an increase from 34 +/- 3 to 35 +/- 3 mm Hg. In the cortex a slight decrease was noted for injection of CM, but this was significant only after injection of iotrolan. All tested contrast media decrease PO2 in the outer renal medulla, which may partly explain contrast medium-induced acute renal failure.  相似文献   

19.
The gross facility of aqueous humor outflow (C) was estimated in the normal in vivo and in vitro dog eye, using tonography and constant pressure perfusion. Tonographic C value for 36 normal eyes, with the dog anesthetized with ketamine hydrochloride and acetylpromazine maleate, was 0.21 (+/- 0.14, SD); the mean tonographic value in 35 eyes with the patient anesthetized with sodium pentobarbital was 0.15 (+/- 0.09). Constant pressure perfusion of the in vivo normal dog eyes at 20 mm of Hg intraocular pressure yielded a mean C value of 0.13 (+/- 0.07) and at 30 mm of Hg 0.18 (+/- 0.13). As intraocular pressure increased from 10 to 50 mm of Hg, the rate of outflow, as determined by constant pressure perfusion, increased. The C values from in vitro constant pressure perfusion were greater than those in the in vivo eyes and deceased in most eyes as intraocular pressure was increased as compared with the in vivo preparation.  相似文献   

20.
Ischemic preconditioning enhances donor lung preservation in the rat   总被引:1,自引:0,他引:1  
BACKGROUND: Ischemic preconditioning achieved by brief periods of ischemia and reperfusion before a prolonged period of ischemia can significantly reduce the extent of cardiac damage in many mammalian species and human beings. In this study we used a rat model of single lung transplantation to show that ischemic preconditioning also occurs in the lung. METHODS: Rats randomly selected for ischemic preconditioning had their left main bronchus and pulmonary artery occluded for 5 minutes, followed by 10 minutes of reperfusion and ventilation. Lungs of control rats were ventilated for 15 minutes. The lungs were perfused with University of Wisconsin solution, then heart and lungs were excised en bloc and stored in University of Wisconsin solution at 0 degree C for 6 or 12 hours. After left pneumonectomy, the left lung of the donor was then implanted into the recipient via left thoracotomy. After 1 hour of ventilation and reperfusion, a right pneumonectomy was performed making the animal completely dependent on the transplanted lung. Samples of arterial blood from the left ventricle were then taken for arterial oxygen tension and arterial carbon dioxide tension determination. Water contents of the donor lungs were measured before and after reperfusion. Thiobarbituric acid reactive substances were measured in the right donor lung after storage. RESULTS: Lungs transplanted after 12 hours of storage had profoundly impaired gas exchange (arterial oxygen tension = 34 +/- 5; arterial carbon dioxide tension = 69 +/- 7 mm Hg) compared with the normal levels in the 6-hour storage group (arterial oxygen tension = 308 +/- 22; arterial carbon dioxide tension = 17 +/- 1 mm Hg). Ischemic preconditioning significantly improved gas exchange in the 12-hour storage group (arterial oxygen tension = 83 +/- 11; arterial carbon dioxide tension = 40 +/- 4 mm Hg). Ischemic preconditioning also significantly decreased thiobarbituric acid reactive substances formation at both 6- and 12-hour storage. CONCLUSIONS: These results show that the phenomenon of ischemic preconditioning occurs in the lung and that it may reduce injury to the donor lung during prolonged cold ischemic storage.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号