首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 93 毫秒
1.
建立了以石墨烯为固相萃取填料,结合高效液相色谱-电喷雾离子阱质谱联用技术测定黑鱼中磺胺类兽药残留的检测方法。采用甲醇作为提取溶剂,经石墨烯固相萃取柱净化富集,质谱采用电喷雾正离子源,多反应监测模式。方法的线性良好,相关系数大于0.998,检出限范围0.0480.288μg/kg,定量限为0.1600.960μg/kg,线性范围内的加标回收率为70.6%93.8%。本方法灵敏、可靠、稳定,满足复杂水产品基质中磺胺类药残检测的需要。   相似文献   

2.
刘雪  余晟  韦彩云  王玲玲 《食品科学》2013,34(2):204-208
以石墨烯为吸附剂制备固相萃取柱,建立固相萃取-高效液相色谱法检测6种磺胺类药物的方法。采用紫外检测器进行定性和定量分析,检测波长为270nm。对包括吸附剂的种类、洗脱剂的种类和用量、样品溶液的pH值和样品体积等参数进行详细优化。在优化条件下,6种磺胺类药物在0.1~100μg/L范围内与峰面积呈良好的线性关系,相关系数为0.990~0.997。检出限(RSN=3)为6.3~21.1ng/L。方法的精密度为2.12%~4.75%。将该方法用于蔬菜样品分析,回收率为79.3%~104.2%。  相似文献   

3.
目的 建立新型固相萃取技术结合超高效液相色谱串联质谱测定猪肉中17种β-受体阻断剂的测定方法。方法 猪肉样品经酶解,乙腈沉淀蛋白并萃取后,经Oasis PRiME HLB固相萃取柱通过式净化。以甲醇和0.1%甲酸水为流动相梯度洗脱,采用迪马Endeavorsil C18色谱柱分离,ESI源正离子模式进行多反应监测(MRM),内标法定量。结果 17种β-受体阻断剂的线性范围在0.2~20 μg/L,相关系数(r)>0.999,检出限(LOD)为0.05~0.07 μg/kg,定量限(LOQ)为0.15~0.2 μg/kg。3个加标水平下(0.2、0.4、2 μg/kg)的回收率为84.97%~123.40%,RSD为0.41%~13.94%。结论 本方法灵敏、快速、准确,可用于猪肉中β-受体阻断剂的定性、定量检测。  相似文献   

4.
目的建立同时测定水产品中磺胺嘧啶(sulfadiazine, SDZ)、磺胺甲恶唑(sulfamethoxazole, SMZ)、磺胺二甲嘧啶(sulfadimidine, SDM)、磺胺间甲氧嘧啶(sulfamonomethoxine, SMM)4种磺胺类药物残留的固相萃取-超高效液相色谱-串联质谱的检测方法。方法样品采用乙腈-0.2%甲酸溶液均质振荡提取,用CaptivaEMR-Lipid固相萃取柱净化,外标法定量。结果 4种磺胺类药物的检出限为0.08~0.12μg/kg,定量限为0.25~0.50μg/kg,回收率均为70.2%~103.4%之间。结论该方法具有基质干扰小、准确,易操作等优点,适用于水产品中4种磺胺类残留药物的检测。  相似文献   

5.
建立固相萃取-高效液相色谱法(solid phase extraction-high performance liquid chromatography, SPE-HPLC)同时检测水产品中15种磺胺类药物(sulfonamides,SAs)残留。样品用乙酸乙酯提取,正己烷脱脂,PCX(polymer cation exchange)固相萃取柱净化,采用高效液相色谱法检测,色谱条件为:Waters C18(4.6 mm×250 mm,5.0μm)色谱柱分离,以甲醇和含体积分数1.1%乙酸的PBS缓冲液(0.01 mol/L)为流动相进行梯度洗脱,检测波长为270 nm。15种SAs在65 min内达到完全分离,在0.5~10.0μg/m L时线性关系良好,相关系数均大于0.990 0;方法检出限为10~20μg/kg,定量限为20~60μg/kg;对空白鱼肉样品进行了3个质量分数水平(500、1 000、 2 000μg/kg)的加标实验,测定其空白加标回收率为73.1%~109.6%,相对标准偏差(relative standard deviations,RSD...  相似文献   

6.
建立同位素内标超高效液相色谱串联质谱法同时测定黄酒中2-甲基咪唑和4-甲基咪唑的定量分析方法。样品加入同位素内标后,以质量分数1%的三氯乙酸提取,经MCX固相萃取柱净化,超高效液相色谱串联质谱分离并检测,内标法定量。在优化条件下,2-甲基咪唑和4-甲基咪唑的检出限分别为0.5μg/kg和0.05μg/kg,在0.1 ng/mL~1 000 ng/mL和1 ng/mL~1 000 ng/mL浓度范围内线性关系良好,相关系数大于0.999。  相似文献   

7.
目的 采用分散固相萃取结合液相色谱-串联质谱仪,建立淡水鱼中9种磺胺和3种喹诺酮类药物的分析方法。方法 淡水鱼肉样品用1%甲酸乙腈提取,提取液经盐析后取乙腈层,用分散固相萃取净化包净化,目标物用C18色谱柱(2.1×50 mm,1.7 μm)分离,采用0.1%甲酸乙腈作为流动相进行梯度洗脱,利用电喷雾离子源正离子多反应监测模式进行测定,内标法定量。结果 9种磺胺和3种喹诺酮类药物在 1.0~50.0 ng/mL 浓度范围内线性关系良好, 相关系数均大于 0.999。检出限和定量限分别为 0.1~1.0 μg/kg、1.0~5.0 μg/kg,在3个不同浓度添加水平下的平均回收率为84.4%~114.0%,相对标准偏差(relative standard deviation, RSD)为 1.2%~7.8%(n=6)。结论 该方法操作简单、快速,灵敏度高,适用于淡水鱼中磺胺和喹诺酮类兽药残留测定。  相似文献   

8.
建立了氧化石墨烯分散固相萃取—液相色谱串联质谱法(LC-MS/MS)检测花生油中涕灭威及其代谢物涕灭威砜和涕灭威亚砜3种农药残留的方法。样品经乙腈提取,以氧化石墨烯分散固相萃取净化后,注入LC-MS/MS检测。色谱柱采用Poroshell 120 EC-C18(3.0×100 mm,2.7μm),在多反应监测模式下检测,外标法定量。结果表明:上述3种农药在浓度5~150μg/L范围内线性关系良好,相关系数r=0.991~0.999,方法检测限为0.6~1.8μg/kg,在不同添加水平下,平均回收率为62%~103%。该方法简便、快速、成本低,能够满足花生油中涕灭威及其代谢物的检测要求。  相似文献   

9.
为提高鱼肉中磺胺类抗生素(sulfonamides,SAs)残留的富集效果,建立了基于氮掺杂三维石墨烯泡沫功能化整体柱(monolith@nitrogen-doped three-dimensional graphene foam,M@NGF)的电增强固相微萃取(electroenhanced solid phase microextraction,EE-SPME)方法,结合高效液相色谱技术,快速、灵敏地测定鱼肉中SAs残留。本研究采用原位聚合法,以离子液体为功能单体,NGF为导电增强剂,在不锈钢丝表面制备多孔M@NGF,建立EE-SPME方法,从鱼肉中萃取磺胺噻唑(sulfathiazole,ST)、磺胺二甲基嘧啶(sulfamethazine,SM2)和磺胺二甲氧嘧啶(sulfadimethoxypyrimidine,SMM)。对吸附时间、搅拌速度、吸附电压、离子强度、样品溶液p H值、解吸时间、解吸电压和解吸液组成进行了优化。结果表明,基于M@NGF的EE-SPME法对ST、SM2和SMM的富集倍数分别为74、58和64,吸附平衡时间缩...  相似文献   

10.
固相萃取-高效液相色谱测定奶粉中磺胺类抗生素残留   总被引:1,自引:0,他引:1  
建立了测定奶粉中磺胺嘧啶和磺胺甲噁唑的固相萃取-高效液相色谱法。奶粉溶于水后经亚铁氰化钾和醋酸锌溶液处理后离心去除脂肪,过C18柱,用水淋洗,甲醇洗脱,洗脱液用于高效液相色谱分析。采用C18柱,流动相为甲醇∶0.08%乙酸=40∶60,检测波长272nm,流速0.8mL/min。结果表明,两种磺胺药物在0.05~1μg/mL的范围内线性良好,回收率为96.8%~97.5%。本方法具有灵敏度高,重复性好等特点。  相似文献   

11.
建立了动物组织中四种苯并咪唑类药物(氟苯哒唑、芬苯哒唑、阿苯哒唑和甲苯哒唑)多残留检测的高效液相色谱串联质谱法.用乙酸乙酯提取样品中的药物,提取液浓缩后加入乙腈和正己烷分配脱脂,采用中性氧化铝小柱净化.以乙腈-水作为流动相,液质联用仪(LC-MS/MS)检测,外标法定量.方法的回收率为60%~85%,平均变异系数<15%,定量限为1 μg/kg.  相似文献   

12.
A novel analytical method employing solid-phase extraction (SPE) coupled with ultra-high-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed for the simultaneous determination of 30 hormones in anti-ageing functional foods (capsules, powders and tablets). The analytes were extracted with acetic acid–acetonitrile (1–99 v/v), methanol and acetone, respectively. The extract was purified using a combined column, followed by analyte detection with electrospray ionisation in positive- or negative-ion modes. The results indicated that the 30 compounds had good linear correlations in the range of 1–1000 μg kg–1, and the correlation coefficients were above 0.99. The limits of detection (LOD) and limits of quantification (LOQ) were 0.03–2 and 0.1–5 μg kg–1, respectively. The average recovery of 30 compounds at the three spiked levels varied from 74.7% to 124.1%, and the relative standard deviation (RSD) was 2.4–15.0%. This method was applied to the analysis of hormones in 14 real samples of which seven hormones (such as estrone, dienestrol) were detected in four samples, but the remainder of the hormones were not detected. The developed method is sensitive, efficient, reliable and applicable to real samples.  相似文献   

13.
Cyromazine and dicyclanil are both used as insect growth regulators. This paper describes an easy and innovative simultaneous extraction method for residues of cyromazine and dicyclanil in food of animal origin, and a confirmation procedure using UHPLC-MS/MS. The sample was extracted, deproteinised by 1% trichloracetic acid in water-acetonitrile, followed by selective defatting using hexane based on the degree of matrix complexity; cleaned-up on an mixed-mode cation exchange (MCX) cartridge; and quantified by using matrix-matched calibration. The mean recoveries were all between 62.0% and 99.2%, and the RSDs were all below 9.94%. The present method was rapid, sensitive and reliable, which was applied to the quantitative analysis of these residues in animal tissues.  相似文献   

14.
比较了超高效液相色谱-串联质谱(UPLC-MS/MS)与高效液相色谱(HPLC)法测定茶叶中10种氨基甲酸酯类农药残留的分析方法。样品经乙腈提取,氨基固相萃取柱净化,HPLC和UPLC-MS/MS测定。结果表明,在相同的前处理条件下,两种方法均具有较好的准确度和精密度,UPLC-MS/MS法在0.01~0.1mg/kg添加水平下回收率为75.2%~115.6%,相对标准偏差(RSD)为4.4%~16.7%。HPLC法在0.05~1.0mg/kg添加水平下回收率为82.7%~120.7%,相对标准偏差(RSD)为0.8%~12.9%。UPLC-MS/MS法相对于HPLC法有更高的灵敏度,10种氨基甲酸酯类农药在UPLC-MS/MS上检出限为0.02~0.3μg/kg,HPLC法检出限为3~7.5μg/kg;其高灵敏度和选择性,使其更适于多农药残留同时检测和微量残留检测。  相似文献   

15.
比较了超高效液相色谱-串联质谱(UPLC-MS/MS)与高效液相色谱(HPLC)法测定茶叶中10种氨基甲酸酯类农药残留的分析方法。样品经乙腈提取,氨基固相萃取柱净化,HPLC和UPLC-MS/MS测定。结果表明,在相同的前处理条件下,两种方法均具有较好的准确度和精密度,UPLC-MS/MS法在0.010.1mg/kg添加水平下回收率为75.2%115.6%,相对标准偏差(RSD)为4.4%16.7%。HPLC法在0.051.0mg/kg添加水平下回收率为82.7%120.7%,相对标准偏差(RSD)为0.8%12.9%。UPLC-MS/MS法相对于HPLC法有更高的灵敏度,10种氨基甲酸酯类农药在UPLC-MS/MS上检出限为0.020.3μg/kg,HPLC法检出限为37.5μg/kg;其高灵敏度和选择性,使其更适于多农药残留同时检测和微量残留检测。   相似文献   

16.
该实验建立了超高效液相色谱-串联质谱法(UPLC-MS/MS)同时测定婴幼儿配方乳粉中氯酸盐和高氯酸盐残留量的方法。样品经甲酸水提取,乙腈沉淀蛋白,乙腈饱和正己烷除去脂肪,采用Anionic Polar Pesticide色谱柱(2.1 mm×150 mm,5 μm)分离,以0.9%甲酸+50 mmol/L甲酸铵水溶液和乙腈为流动相梯度洗脱,在电喷雾离子源负离子(ESI-)多反应监测模式条件下,对氯酸盐和高氯酸盐进行定性和定量分析。结果表明,高氯酸盐和氯酸盐分别在0.5~50.0 μg/L和1.0~100.0 μg/L范围内线性关系良好,高氯酸盐和氯酸盐的定量限(LOQ)分别为7.5 μg/kg和15.0 μg/kg。高氯酸盐和氯酸盐的加标回收率为82.5%~98.5%,精密度试验结果的相对标准偏差(RSD)为2.0%~8.7%;该方法稳定、准确、灵敏度高,可用于婴幼儿配方乳粉中氯酸盐和高氯酸盐残留量检测。  相似文献   

17.
UPLC-MS/MS法检测肉制品中克伦特罗残留量的不确定度评定   总被引:1,自引:0,他引:1  
建立了UPLC-MS/MS法检测肉制品中克伦特罗残留量的不确定度评定方法,分析了肉制品中克伦特罗残留量的测定过程中供试品重复性测量、标准曲线拟合残差、标准品溶液的配制、供试品溶液的配制、分析仪器等因素对测定的不确定度的影响。结果表明,按照JJF1059-1999《测量不确定度评定与表示》对各不确定度分量合成和扩展,当置信概率为95%,包含因子k=2,其扩展相对不确定度为16.08%。通过对不确定度的分析,发现标准曲线拟合残差是不确定度的主要来源,并由此提出了质量控制改进方法。该研究对于肉制品中克伦特罗残留量测量的不确定度标准制定具有一定的示范意义。   相似文献   

18.
为建立一种白酒香型鉴别方法,以DB-WAX为色谱柱,样品加标后直接采用气相色谱(GC)法进样分析。结果表明,香气成分线性相关系数R2>0.999,检测限<5.11 mg/L,精密度试验结果的相对标准偏差(RSD)<4.11%;平均回收率为80.20%~97.93%。采用偏最小二乘法(PLS)对不同香型白酒数据进行建模和预测,不同香型白酒样品在PLS得分图中能分开,利用训练集和验证集数据对模型进行验证,结果表明预测准确率较高,校正均方差(RMSEE)和预测均方差(RMSEP)值也说明PLS模型对不同白酒香型具有较强的预测性。该方法在判别白酒香型分析中具有较高的准确性。  相似文献   

19.
利用加速溶剂萃取结合超高效液相色谱-串联质谱(UPLC-MS∕MS)技术,建立了一种能在6min内快速分离和测定涤纶中禁用偶氮染色剂可分解出的22种致癌芳香胺的方法。样品经丙酮加速溶剂萃取、浓缩,再经氧化-还原裂解反应,用乙酸乙酯萃取反应液中的芳香胺,再将萃取液用N2吹至近干,用甲醇-水溶液(1∶9,v∶v)溶解定容,采用Acquity UPLC BEH C18柱(100 mm × 2.1 mm,1.7 μm)分离,以甲醇-0.05%甲酸溶液为流动相,梯度洗脱,电喷雾正离子模式多反应监测,外标法定量。该方法在0.01~0.2 μg/mL范围内线性关系良好(γ>0.99),在添加浓度为15 ~ 30 mg/kg水平内,平均回收率范围为33.28 ± 1.83~ 107.14 ± 1.10 %,相对标准偏差(RSD)为0.38 ~ 10.9%,方法检出限(LOD)为0.96 ~ 17 μg/kg,方法定量限(LOQ)为3.2 ~ 56.1 μg/kg。本方法样品前处理自动化程度高,操作过程简便快速,重复性好,能满足涤纶中的可分解出致癌芳香胺的禁用偶氮染色剂的快速筛选与测定。  相似文献   