首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method has been developed for detecting DNA separated by capillary gel electrophoresis (CGE) using single molecule photon burst counting. A confocal fluorescence microscope was used to observe the fluorescence bursts from single molecules of DNA multiply labeled with the thiazole orange derivative T06 as they passed through the approximately 2 micrometer diameter focused laser beam. Amplified photoelectron pulses from the photomultiplier are grouped into bins of 360-450 micros in duration, and the resulting histogram is stored in a computer for analysis. Solutions of M13 DNA were first flowed through the capillary at various concentrations, and the resulting data were used to optimize the parameters for digital filtering using a low-pass Fourier filter, selecting a discriminator level for peak detection, and applying a peak-calling algorithm. Statistical analyses showed that (i) the number of M13 molecules counted versus concentration was linear with slope = 1, (ii) the average burst duration was consistent with the expected transit time of a single molecule through the laser beam, and (iii) the number of detected molecules was consistent with single molecule detection. The optimized single molecule counting method was then applied to an electrophoretic separation of M13 DNA and to a separation of pBR 322 DNA from pRL 277 DNA. Clusters of discreet fluorescence bursts were observed at the expected appearance time of each DNA band. The autocorrelation function of these data indicated transit times that were consistent with the observed electrophoretic velocity. These separations were easily detected when only 50-100 molecules of DNA per band traveled through the detection region. This new detection technology should lead to the routine analysis of DNA in capillary columns with an on-column sensitivity of approximately 100 DNA molecules/band or better.  相似文献   

2.
A method has been developed for highly sensitive detection of specific DNA sequences in a homogeneous assay using labeled oligonucleotide molecules in combination with single-molecule photon burst counting and identification. The fluorescently labeled oligonucleotides are called smart probes because they report the presence of complementary target sequences by a strong increase in fluorescence intensity. The smart probes consist of a fluorescent dye attached at the terminus of a hairpin oligonucleotide. The presented technique takes advantage of the fact that the used oxazine dye JA242 is efficiently quenched by complementary guanosine residues. Upon specific hybridization to the target DNA, the smart probe undergoes a conformational change that forces the fluorescent dye and the guanosine residues apart, thereby increasing the fluorescence intensity about six fold in ensemble measurements. To increase the detection sensitivity below the nanomolar range, a confocal fluorescence microscope was used to observe the fluorescence bursts from individual smart probes in the presence and absence of target DNA as they passed through the focused laser beam. Smart probes were excited by a pulsed diode laser emitting at 635 nm with a repetition rate of 64 MHz. Each fluorescence burst was identified by three independent parameters: (a) the burst size, (b) the burst duration, and (c) the fluorescence lifetime. Through the use of this multiparameter analysis, higher discrimination accuracies between smart probes and hybridized probe-target duplexes were achieved. The presented multiparameter detection technique permits the identification of picomolar target DNA concentrations in a homogeneous assay, i.e., the detection of specific DNA sequences in a 200-fold excess of labeled probe molecules.  相似文献   

3.
We employed a liquid core waveguide to image both DNA electrophoresis separations and isoelectric focusing of proteins. The utility of the system is demonstrated for DNA fragment sizing and protein separations. The system utilizes the liquid-core waveguide as an efficient window for both the excitation of separated samples and the collection of light through total internal reflectance, with an ability to detect target molecules in the zeptomolar range. Scanning the excitation laser along the length of the electrophoresis capillary excites individually separated analyte bands, while the fluorescence is collected end-on by an optical fiber coupled to a photomultiplier, thus, creating an image of the separation along the length of the capillary.  相似文献   

4.
This paper reports the demonstration of efficient single molecule detection in flow cytometry by two-photon fluorescence excitation. We have used two-photon excitation (TPE) to detect single DNA fragments as small as 383 base pairs (bp) labeled with the intercalating dye, POPO-1, at a dye:nucleotide ratio of 1:5. TPE of the dye-DNA complexes was accomplished using a mode-locked, 120 fs pulse width Ti:sapphire laser operating at 810 nm. POPO-1 labeled DNA fragments of 1.1 kilobase pairs (kbp) and larger were sequentially detected in our flow cytometry system with a detection efficiency of nearly 100%. The detection efficiency for the 383 bp DNA fragments was approximately 75%. We also demonstrate the ability to distinguish between different sized DNA fragments in a mixture by their individual fluorescence burst sizes by TPE. These studies indicate that using TPE for single molecule flow cytometry experiments lowers the intensity of the background radiation by approximately an order of magnitude compared to one-photon excitation, due to the large separation between the excitation and emission wavelengths in TPE.  相似文献   

5.
6.
Rapid microchip reversed-phase HPLC of peptides and proteins at pressure gradients of 12 bar/cm (180 psi/cm) has been performed using a microdevice that integrates subnanoliter on-chip injection and separation with a miniaturized fluorescence detector. Proteins and peptides were separated on a C18 side-chain porous polymer monolith defined by contact lithography, and injection was achieved via a pressure-switchable fluoropolymer valve defined using projection lithography. Preliminary separations of peptide standards and protein mixtures were performed in 40-200 s, and switching between samples with no detectible sample carryover has been performed. The injections and separations were reproducible; the relative standard deviation (RSD) for retention time was 0.03%, and peak area RSD was 3.8%. Sample volumes ranging from 220 to 800 pL could be linearly metered by controlling the pressure injection pulse duration with conventional timing and valving. The current prototype system shows the potential for rapid and autonomous HPLC separations with varying modalities and the potential for direct connection to mass spectrometers at nanospray flow rates.  相似文献   

7.
This paper describes the first use of frequency-domain fluorescence lifetime for multiplex detection of DNA restriction fragments in capillary electrophoresis (CE). The fragments were labeled with monomeric intercalating dyes that can be excited by either the 488- or 514-nm line of an argon ion laser and have lifetimes in the range of 0.5-2.5 ns. We were able to achieve multiplex lifetime detection in the CE separation of a restriction fragment digest and a DNA size ladder in the same run, for fragments shorter than 700 bp. Different gel buffer systems, including a modified polyacrylamide gel and several tris-borate-EDTA/hydroxyethylcellulose (TBE/HEC) gels, were investigated for separation and detection of the dye-labeled DNA fragments. Best results for both electrophoretic resolution and lifetime detection were obtained using a gel containing 1% high molecular weight (90,000-105,000) HEC and 0.3% low molecular weight (24,000-27,000) HEC in TBE buffer.  相似文献   

8.
The rate of detection and sizing of individual fluorescently labeled DNA fragments in conventional single-molecule flow cytometry (SMFC) is limited by optical saturation, photon-counting statistics, and fragment overlap to approximately 100 fragments/s. We have increased the detection rate for DNA fragment sizing in SMFC to approximately 2000 fragments/s by parallel imaging of the fluorescence from individual DNA molecules, stained with a fluorescent intercalating dye, as they passed through a planar sheet of excitation laser light, resulting in order of magnitude improvements in the measurement speed and the sample throughput compared to conventional SMFC. Fluorescence bursts were measured from a fM solution of DNA fragments ranging in size from 7 to 154 kilobase pairs. A data acquisition time of only a few seconds was sufficient to determine the DNA fragment size distribution. A linear relationship between the number of detected photons per burst and the DNA fragment size was confirmed. Application of this parallel fluorescence imaging method will lead to improvements in the speed, throughput, and sensitivity of other types of flow-based analyses involving the study of single molecules, chromosomes, cells, etc.  相似文献   

9.
Separations of 15 pM rhodamine 6G and 30 pM rhodamine B performed in a micromachined electrophoresis channel were detected by counting fluorescence bursts from individual molecules. The migration times, peak widths, and analyte concentrations were estimated from the number and the migration time distribution of the detected molecules. Concentration detection limits estimated at >99% confidence were 1.7 pM rhodamine 6G and 8.5 pM rhodamine B. The separations required <35 s and the relative migration time uncertainties were less than 2.0%. These are the lowest detection limits reported for microchip separation devices and the first example of single-chromophore molecular counting for detection of chemical separations.  相似文献   

10.
Single-nucleotide polymorphisms (SNPs) are the most frequent type of human genetic variation. Recent work has shown that it is possible to directly analyze SNPs in unamplified human genomic DNA samples using the surface-invasive cleavage reaction followed by rolling circle amplification (RCA) labeling of the cleavage products. The individual RCA amplicon molecules were counted on the surface using fluorescence microscopy. Two principal limitations of such single-molecule counting are the variability in the amplicon size, which results in a large variation in fluorescence signal intensity from the dye-labeled DNA molecules, and a high level of background fluorescence. It is shown here that an excellent alternative to RCA labeling is tagging with gold nanoparticles followed by imaging with a scanning electron microscope. Gold nanoparticles have a uniform diameter (15 +/- 0.5 nm) and provide excellent contrast against the background of the silicon substrate employed. Individual gold nanoparticles are readily counted using publicly available software. The results demonstrate that the labeling efficiency is improved by as much as approximately 15-fold, and the signal-to-noise ratio is improved by approximately 4-fold. Detection of individual cleaved DNA molecules following surface-invasive cleavage was linear and quantitative over 3 orders of magnitude in amount of target DNA (10(-18)-10(-15) mol).  相似文献   

11.
We demonstrate that electrophoresis on a flat Si substrate is an effective method in separation of DNA with different configurations, e.g., linear, supercoiled, and relaxed or DNA of different length, e.g., supercoiled DNA ladder. The surface separation arises from the different number of contacts due to the conformational differences between adsorbed DNA chains. Imposing a Au nanopattern on the Si surface further improves the separation effect. The simulation of electric field on this patterned surface by the finite element method shows that Au nanodots act as local pinning points for DNA segments due to dielectrophoretic force. The results of molecular dynamics simulation showed that the conformational differences between adsorbed polymer chains were amplified on the patterned surface and enhanced separations were achieved, which are consistent with the experimental results.  相似文献   

12.
Isotachophoretic separations are triggered at the border of a nanochannel-induced ion-depleted zone. This depletion zone acts as a terminating electrolyte and is created by concentration polarization over the nanochannel. We show both continuous and discrete sample injections as well as separation of up to four analytes. Continuous injection of a spacer compound was used for selective analyte elution. Zones were kept focused for over one hour, while shifting less than 700 μm. Moreover, zones could be deliberately positioned in the separation channel and focusing strength could be precisely tuned employing a three-point voltage actuation scheme. This makes depletion zone isotachophoresis (dzITP) a fully controllable single-electrolyte focusing and separation technique. For on-chip electrokinetic methods, dzITP sets a new standard in terms of versatility and operational simplicity.  相似文献   

13.
A new technique combining scanning electrochemical microscopy (SECM) and single-molecule fluorescence spectroscopy was developed to accomplish locally and temporally defined pH adjustments in buffer solutions and on surfaces monitored by fluorescence alteration of pH-sensitive fluorophores in real time. Local pH gradients were created by electrochemical generation of H(+) or OH(-) during redox reactions at ultramicro- or nanoelectrodes with radii from 5 microm to 35 nm. Ratiometric fluorescence measurements were performed with a confocal laser microscope using two detectors for different spectral regions. Time-resolved pH measurements were carried out with freely diffusing SNARF-1-dextran. For pH measurements on surfaces, total internal reflection fluorescence microscopy was used in combination with a CCD camera. The fluorophore SNAFL-succinimidyl ester was bound to amino-terminated octadecylsilane-coated coverslips. Local pH determinations could be accomplished with an accuracy of 0.2 unit. The measured pH profiles showed a strong dependence on the tip diameter, the buffer/mediator concentration ratio, and the tip-surface distance. As an application for bionanotechnology using SECM-induced pH changes on the molecular level, the proton-driven ATP synthesis by single membrane-bound F(0)F(1)-ATP synthases was investigated. ATP synthesis resulted in stepwise subunit rotation within the enzyme that was monitored by single-molecule fluorescence resonance energy transfer.  相似文献   

14.
Microchips for integrated capillary electrophoresis systems were produced by molding a poly(dimethylsiloxane) (PDMS) silicone elastomer against a microfabricated master. The good adhesion of the PDMS devices on clean planar surfaces allows for a simple and inexpensive generation of networks of sealed microchannels, thus removing the constraints of elaborate bonding procedures. The performance of the devices is demonstrated with both fast separations of φX-174/HaeIII DNA restriction fragments labeled with the intercalating dye YOYO-1 and fluorescently labeled peptides. Detection limits in the order of a few zeptomoles (10(-)(21) mol) have been achieved for each injected DNA fragment, corresponding to a mass detection limit of ~2 fg for the 603 base pair fragment. Single λ-DNA molecules intercalated with YOYO-1 at a base pair-to-dye ratio of 10:1 could be detected with an uncomplicated laser-induced fluorescence detection setup. High single-molecule detection efficiency (>50%) was achieved under electrophoretically controlled mass transport conditions in PDMS microchannels.  相似文献   

15.
We describe instrumentation for real-time detection of single-molecule fluorescence in guided streams of 1-mum (nominal) water droplets. In this technique, target molecules were confined to droplets whose volumes were comparable with illumination volumes in diffraction-limited fluorescence microscopy and guided to the waist of a cw probe laser with an electrostatic potential. Concentration detection limits for Rhodamine 6G in water were determined to be ~1 fM, roughly 3 orders of magnitude lower than corresponding limits determined recently with diffraction-limited microscopy techniques for a chemical separation of similar dyes. In addition to its utility as a vehicle for probing single molecules, instrumentation for producing and focusing stable streams of 1-2-mum-diameter droplets may have other important analytical applications as well.  相似文献   

16.
Fu Y  Lakowicz JR 《Analytical chemistry》2006,78(17):6238-6245
Methods that increase the total emission per fluorophore would provide increased sensitivity and a wider dynamic range for chemical analysis, medical diagnostics, and in vivo molecular imaging. The use of fluorophore-metal interactions has the potential to dramatically increase the detectability of single fluorophores for bioanalytical monitoring. The fabrication and single-molecule analysis of fluorophore-labeled DNA molecules tethered to silver island films are described in this article. The single-molecule spectroscopic method reveals some insightful information on the behaviors of single molecules, rather than an ensemble of molecules. Analysis of fluorescence images, intensity profiles, total emitted photons, and lifetime distributions reveals some of sample heterogeneities. Investigations of time-dependent emission characteristics of single molecules indicate that the total number of emitted photons on the silvered surface is more than 10 times greater than on free labeled DNA molecules on a glass substrate. In addition, time-correlated single-photon counting results reveal the reduced lifetimes of single molecules tethered to silver island films.  相似文献   

17.
Encapsulation of molecules in phospholipid vesicles provides unique opportunities to study chemical reactions in small volumes as well as the behavior of individual proteins, enzymes, and ribozymes in a confined region without requiring a tether to immobilize the molecule to a surface. These experiments generally depend on generating a predictable loading of vesicles with small numbers of target molecules and thus raise a significant measurement challenge, namely, to quantify molecular occupancy of vesicles at the single-molecule level. In this work, we describe an imaging experiment to measure the time-dependent fluorescence from individual dye molecules encapsulated in ~130 nm vesicles that are adhered to a glass surface. For determining a fit of the molecular occupancy data to a Poisson model, it is critical to count empty vesicles in the population since these dominate the sample when the mean occupancy is small, λ ≤ ~1. Counting empty vesicles was accomplished by subsequently labeling all the vesicles with a lipophilic dye and reimaging the sample. By counting both the empty vesicles and those containing fluors, and quantifying the number of fluors present, we demonstrate a self-consistent Poisson distribution of molecular occupancy for well-solvated molecules, as well as anomalies due to aggregation of dye, which can arise even at very low solution concentrations. By observation of many vesicles in parallel in an image, this approach provides quantitative information about the distribution of molecular occupancy in a population of vesicles.  相似文献   

18.
High-efficiency capillary isoelectric focusing of peptides   总被引:6,自引:0,他引:6  
Several approaches are presently being developed for global proteome characterization that are based upon the analysis of polypeptide mixtures resulting from digestion of (often complex) mixtures of proteins. Improved methods for peptide analysis are needed that provide for sample concentration, higher resolution separations, and direct compatibility with mass spectrometry. In this work, methods for the high-efficiency capillary isoelectric focusing (CIEF) separation of peptides have been developed that provide for simultaneous sample concentration and separation according to peptide isoelectric point. Under typical nondenaturing CIEF conditions, peptides are concentrated approximately 500-fold, and peptides present at < 1 ng/ microL were detectable using conventional UV detection. CIEF separations of peptides provided much faster measurements of isoelectric points compared with conventional isoelectric focusing in gels. Very small differences in peptide isoelectric points (deltapI approximately 0.01) could be resolved, High-efficiency CIEF separations for complex peptide mixtures from tryptic digestion of yeast cytosol fractions were obtained and showed significant improvement over those obtained using capillary zone electrophoresis and packed capillary reversed-phase liquid chromatography.  相似文献   

19.
Miniaturized electrophoresis was successfully coupled with native fluorescence detection for direct analysis of proteins in one- and two-dimensional separations. The detection setup was based on direct observation of the UV-induced fluorescence of proteins using a CCD camera and a Hg (Xe) lamp for sample excitation. Protein mixtures were readily separated by size on a 1-cm segment of the one-dimensional gel in 8 min, and a detection limit of 0.04 ng per band was achieved. The dynamic range of the system was larger than 2 orders of magnitude. Miniaturized slab gel electrophoresis was performed on a special holder designed to couple isoelectric focusing with SDS-PAGE. Two-dimensional separation, including rehydration of IEF strip and fluorescence detection was completed in 2.5 h. Approximately 200 protein spots from Escherichia coli were detected on a 1 cm(2) area. A detection limit of 0.1 microg of total protein was achieved. The operation should be amenable to total automation.  相似文献   

20.
A microfabricated glass chip containing fluidic channels filled with polymer monolith has been developed for reversed-phase electrochromatography. Acrylate-based porous polymer monoliths were cast in the channels by photopolymerization to serve as a robust and uniform stationary phase. UV light-initiated polymerization allows for patterning of polymer stationary phase in the microchip, analogous to photolithography, using a mask and a UV lamp for optimal design of injection, separation, and detection manifolds. The monoliths are cast in situ in less than 10 min, are very reproducible with respect to separation characteristics, and allow easy manipulation of separation parameters such as charge, hydrophobicity, and pore size. Moreover, the solvent used to cast the polymer enables electroosmotic flow, allowing the separation channel to be conditioned without need for high-pressure pumps. The microchip was used for separation of bioactive peptides and amino acids labeled with a fluorogenic dye (naphthalene-2,3-dicarboxaldehyde) followed by laser-induced fluorescence detection using a Kr+ ion laser. The microchip-based separations were fast (six peptides in 45 s), efficient (up to 600,000 plates/m), and outperformed the capillary-based separations in both speed and efficiency. We have also developed a method for complete removal of polymer from the channels by thermal incineration to regenerate the glass chips.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号